772 resultados para CONVENTIONAL HYBRID
Resumo:
In situ and ex situ studies concerning the new hybrid material vanadium pentoxide xerogel in the presence of the cationic surfactant cetyl pyridinium chloride (V(2)O(5)/CPC) are presented. The in situ characterization studies revealed the presence of a lamellar structure for the V(2)O(5)/CPC hybrid material. The intercalation reaction was evidenced on the basis of the increase in the d-spacing as well as the displacement of the infrared bands toward lower energy levels. Electrochemical studies comprising the cyclic voltammetry and the electrochemical impedance spectroscopy techniques showed that the behavior of the hybrid material is considerably influenced by the electrolyte composition. The ion insertion/de-insertion into the V(2)O(5) xerogel structure accompanying the charge transfer process is influenced by the solid-state diffusion process modeled by using the finite-space Warburg element.
Resumo:
Vanadyl phosphate and its hybrid compounds have proven to undergo electrochemical intercalation and de-intercalation of lithium ions, which enables its use as cathode material for Li ion rechargeable batteries. In this context, vanadyl phosphate di-hydrate/polyaniline derivatives hybrid films were synthesized via the exfoliation and reconstruction approach in order to evaluate their potential use as cathode in ion lithium batteries. X-ray diffraction patterns indicate that the lamellar structure of the inorganic matrix is maintained, consistent with the topotactic process. In the scanning electron micrographs, hybrid films exhibit rough surface consisting of warped and cracked crystallites, quite different from vanadyl phosphate di-hydrate square platelets crystallites. Electrochemical evaluation using cyclic voltammetry and charge-discharge galvanostatic techniques shows small differences between the charge and the discharge curves, indicating an irreversibility of the hybrid systems. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
High removal rate (up to 16.6 mm(3)/s per mm) grinding of alumina and alumina-titania was investigated with respect to material removal and basic grinding parameters using a resin-bond 160 mu m grit diamond wheel at the speeds of 40 and 160 m/s, respectively. The results show that the material removal for the single-phase polycrystalline alumina and the two-phase alumina-titania composite revealed identical mechanisms of microfracture and grain dislodgement under the grinding conditioned selected. There were no distinct differences in surface roughness and morphology for both materials ground at either conventional or high speed. An increase in material removal rate did not necessarily worsen the surface toughness for the two materials at both speeds. Also the grinding forces for the two ceramics demonstrated similar characteristics at any grinding speeds and specific removal rates. Both normal and tangential grinding forces and their force ratios at the high speed were lower than those at the conventional speed, regardless of removal rates. An increase in specific removal rate caused more rapid increases in normal and tangential forces obtained at the conventional grinding speed than those at the high speed. Furthermore, it is found that the high speed grinding at all the removal rates exerted a great amount of coolant-induced normal forces in grinding zone, which were 4-6 times higher than the pure normal grinding forces. (c) 2004 Elsevier Ltd. All rights reserved.
Resumo:
A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objectives This study was designed to evaluate whether the absence of coronary calcium could rule out >= 50% coronary stenosis or the need for revascularization. Background The latest American Heart Association guidelines suggest that a calcium score (CS) of zero might exclude the need for coronary angiography among symptomatic patients. Methods A substudy was made of the CORE64 (Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors) multicenter trial comparing the diagnostic performance of 64-detector computed tomography to conventional angiography. Patients clinically referred for conventional angiography were asked to undergo a CS scan up to 30 days before. Results In all, 291 patients were included, of whom 214 (73%) were male, and the mean age was 59.3 +/- 10.0 years. A total of 14 (5%) patients had low, 218 (75%) had intermediate, and 59 (20%) had high pre-test probability of obstructive coronary artery disease. The overall prevalence of >= 50% stenosis was 56%. A total of 72 patients had CS = 0, among whom 14 (19%) had at least 1 >= 50% stenosis. The overall sensitivity for CS = 0 to predict the absence of >= 50% stenosis was 45%, specificity was 91%, negative predictive value was 68%, and positive predictive value was 81%. Additionally, revascularization was performed in 9 (12.5%) CS = 0 patients within 30 days of the CS. From a total of 383 vessels without any coronary calcification, 47 (12%) presented with >= 50% stenosis; and from a total of 64 totally occluded vessels, 13 (20%) had no calcium. Conclusions The absence of coronary calcification does not exclude obstructive stenosis or the need for revascularization among patients with high enough suspicion of coronary artery disease to be referred for coronary angiography, in contrast with the published recommendations. Total coronary occlusion frequently occurs in the absence of any detectable calcification. (Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors [CORE-64]; NCT00738218) (J Am Coll Cardiol 2010;55:627-34) (C) 2010 by the American College of Cardiology Foundation
Resumo:
Purpose: To evaluate the risk of geographic miss associated with the classic four-field ""box"" irradiation technique and to define the variables that predict this risk. Materials and Methods: The study population consisted of 80 patients with uterine cervix cancer seen between 2001 and 2006. Median age was 55 years (23-82 years), and 72 (90%) presented with squamous cell carcinoma. Most patients (68.7%) presented with locally advanced disease (IIb or more). Magnetic resonance imaging findings from before treatment were compared with findings from simulation of the conventional four-field ""box"" technique done with rectal contrast. Study variables included tumor volume; involvement of vagina, parametrium, bladder, or rectum; posterior displacement of the anterior rectal wall; and tumor anteroposterior diameter (APD). Margins were considered adequate when the target volume (primary tumor extension, whole uterine body, and parametrium) was included within the field limits and were at least 1 cm in width. Results: Field limits were inadequate in 45 (56%) patients: 29 (36%) patients at the anterior and 28 (35%) at the posterior border of the lateral fields. Of these, 12 patients had both anterior and posterior miss, and this risk was observed in all stages of the disease (p = 0.076). Posterior displacement of the anterior rectal wall beyond S2-S3 was significantly correlated with the risk of geographic miss (p = 0.043). Larger tumors (APD 6 cm or above and volume above 50 cm(3)) were also significantly correlated with this risk (p = 0.004 and p = 0.046, respectively). Conclusions: Posterior displacement of the anterior rectal wall, tumor APD, and volume can be used as guidance in evaluating the risk of geographic miss. (C) 2009 Elsevier Inc.
Resumo:
Background/Aims: Cytokines have a significant role in the response to injury following liver transplantation, but the origin and course of such molecules are not completely known. The aim of this study was to evaluate the production and liver metabolism of the inflammatory cytokines interleukin (IL)-1 beta, IL-6, IL-8, interferon (IFN)-Y and tumor necrosis factor (TNF)-alpha in orthotopic liver transplantation (OLT), comparing the conventional and the piggyback methods. Methodology: We performed a study of 30 patients who underwent elective OLT and were randomized for the conventional or piggyback techniques at the beginning of the operation. The amount of cytokines and their hepatic metabolism were calculated based on plasma concentrations and vascular blood flow at 2, 5, 10, 15, 30, 60, 90, and 120 minutes after revascularization. Results: The amount of IL-1 beta in portal blood was higher in patients who underwent surgery using the conventional technique (estimate interest = 63,783.9 +/- 16,586.1 pg/min, versus 11,979.6 +/- 16,585.7 pg/min in the piggyback group, p=0.035). There were no significant differences between the two operative`s methods for IL-6, IL-8, IFN-Y and TNF-alpha production. The hepatic metabolism of cytokines was not different between groups. Although all the curves showed higher amounts of cytokines with the conventional technique, these were not statistically significant. Conclusion: The study shows the similarity between the two techniques concerning the stimuli for the production of inflammatory molecules.
Resumo:
Background: Worsening in clinical and cardiac status has been noted after chronic right ventricular pacing, but it is uncertain whether atriobiventricular (BiVP) is preferable to atrio-right ventricular pacing (RVP). Conventional versus Multisite Pacing for BradyArrhythmia Therapy study (COMBAT) sought to compare BiVP versus RVP in patients with symptomatic heart failure (HF) and atrioventricular (AV) block. Methods and Results: COMBAT is a prospective multicenter randomized double blind crossover study. Patients with New York Heart Association functional class (FC) II-IV, left ventricular ejection fraction (LVEF) <40%, and AV block as an indication for pacing were enrolled. All patients underwent biventricular system implantation and then were randomized to receive successively (group A) RVP-BiVP-RVP, or (group B) BiVP-RVP-BiVP. At the end of each 3-month crossover period, patients were evaluated according to Quality of Life (QoL), FC, echocardiographic parameters, 6-Minute Walk Test (6MWT), and peak oxygen consumption (VO(2max)). Sixty patients were enrolled, and the mean follow-up period was 17.5 +/- 10.7 months. There were significant improvements in QoL, FC, LVEF, and left ventricular end-systolic volume with BiVP compared with RVP. The effects of pacing mode on 6MWT and VO(2max) were not significantly different. Death occurred more frequently with RVP. Conclusion: In patients with systolic HF and AV block requiring permanent ventricular pacing, BiVP is superior to RVP and should be considered the preferred pacing mode. (J Cardiac Fail 2010;16:293-300)
Resumo:
Purpose: To compare the sparing potential of cerebral hemispheres with intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for whole-ventricular irradiation (WVI) and conventional whole-brain irradiation (WBI) in the management of localized central nervous system germ cell tumors (CNSGCTs). Methods and Materials: Ten cases of patients with localized CNSGCTs and submitted to WVI by use of IMRT with or without a ""boost"" to the primary lesion were selected. For comparison purposes, similar treatment plans were produced by use of 3D-CRT (WVI with or without boost) and WBI (opposed lateral fields with or without boost), and cerebral hemisphere sparing was evaluated at dose levels ranging from 2 Gy to 40 Gy. Results: The median prescription dose for WVI was 30.6 Gy (range, 25.2-37.5 Gy), and that for the boost was 16.5 Gy (range, 0-23.4 Gy). Mean irradiated cerebral hemisphere volumes were lower for WVI with IMRT than for 3D-CRT and were lower for WVI with 3D-CRT than for WBI. Intensity-modulated radiotherapy was associated with the lowest irradiated volumes, with reductions of 7.5%, 12.2%, and 9.0% at dose levels., compared with 3D-CRT. Intensity-modulated radiotherapy provided of 20, 30, and 40 Gy, respectively statistically significant reductions of median irradiated volumes at all dose levels (p = 0.002 or less). However, estimated radiation doses to peripheral areas of the body were 1.9 times higher with IMRT than with 3D-CRT. Conclusions: Although IMRT is associated with increased radiation doses to peripheral areas of the body, its use can spare a significant amount of normal central nervous system tissue compared with 3D-CRT or WBI in the setting of CNSGCT treatment. (C) 2010 Elsevier Inc.
Resumo:
1. Evidence for a 'putative beta(4)-adrenoceptor' originated over 20 years ago when cardiostimulant effects were observed to nonconventional partial agonists, These agonists were originally described as beta(1)- and beta(2)-adrenoceptor antagonists; however, they cause cardiostimulant effects at much higher concentrations than those required to block beta(1)- and beta(2)-adrenoceptors. Cardiostimulant effects of non-conventional partial agonists have been observed in mouse, rat, guinea-pig, cat, ferret and human heart tissues, 2. The receptor is expressed in several heart regions, including the sinoatrial node, atrium and ventricle, 3. The receptor is resistant to blockade by most antagonists that possess high affinity for beta(1)- and beta(2)- adrenoceptors, but is blocked with moderate affinity by (-)-bupranolol and CGP 20712A. 4. The receptor is pharmacologically distinct from the beta(3)-adrenoceptor. Micromolar concentrations of beta(3)-adrenoceptor agonists have no agonist or blocking activity, The receptor is also resistant to blockade by a beta(3)-adrenoceptor-selective antagonist. 5. The receptor mediates increases in cAMP levels and cAMP-dependent protein kinase (PK) A activity in cardiac tissues. Phosphodiesterase inhibition potentiates the positive chronotropic and inotropic effects of non-conventional partial agonists. 6. The receptor mediates hastening of atrial and ventricular relaxation, which is consistent with involvement of a cAMP-dependent pathway. 7. The non-conventional partial agonist (-)-[H-3]-CGP 12177A labels the cardiac putative beta(4)-adrenoceptor, Non-conventional partial agonists compete for binding with affinities that are closely similar to their agonist potencies, Catecholamines compete for binding in a stereoselective manner with a rank order of affinity of (-)-R0363 > (-)-isoprenaline > (-)-noradrenaline greater than or equal to (-)-adrenaline much greater than (-)-isoprenaline, suggesting that catecholamines can interact with the receptor. 8. The putative beta(4)-adrenoceptor appears to be coupled to the G(s)-adenylyl cyclase system, which could serve as a guide to its future cloning, Activation of the receptor may plausibly improve diastolic function but could also mediate arrhythmias.
Resumo:
We compared the aldosterone-producing potency of the angiotensin II-sensitive wild-type aldosterone synthase genes and the ACTH-sensitive hybrid 11 beta-hydroxylase/aldosterone synthase gene by examining aldosterone, PRA, and cortisol day-curves (2-hourly levels over 24 h) in patients with familial hyperaldosteronism type I, before and during long-term (0.8-13.5 yr) glucocorticoid treatment. In 8 untreated patients, PRA levels were usually suppressed, and aldosterone correlated strongly with cortisol (r = 0.69-0.99). Fourteen studies were performed on 10 patients receiving glucocorticoid treatment that corrected hypertension, hypokalemia, and PRA suppression in all. ACTH was markedly and continuously suppressed in 6 studies, 3 of which demonstrated strong correlations between aldosterone and PRA (r = 0.77-0.92), ACTH was only partially suppressed in the remaining 8 studies; aldosterone correlated strongly: 1) with cortisol alone in 5 (r = 0.71-0.98); 2) with cortisol (r = 0.90) and PRA (r = 0.74) in one; 3) with PRA only in one (r = 0.80); and 4) with neither PRA nor cortisol in one. Unless ACTH is markedly and continuously suppressed, aldosterone is more responsive to ACTH than to renin/angiotensin II, despite the latter being unsuppressed. This is consistent with the hybrid gene being more powerfully expressed than the wild-type aldosterone synthase genes in familial hyperaldosteronism type I.
Resumo:
BACKGROUND & AIMS: There is controversy over whether coagulation status predicts bleeding caused by ulceration after esophageal varices band ligation (EVL). METHODS: EVL was performed for primary (n = 45) or secondary (n = 105) prophylaxis in 150 patients with cirrhosis (Child A, n = 74, 49%; Child B, n = 42, 28%; Child C, n = 34, 23%). International normalized ratio (INR) and platelet counts were assessed in all. In 92 patients, levels of factor V, fibrinogen, D-dimer, protein C and protein S, von Willebrand factor, and thromboelastography (TEG) were assessed. Platelet count < 50 x 10(3)/mm(3) and INR > 1.5 were considered high-risk cutoff for bleeding. Conversely, platelet count >= 50 x 10(3)/mm(3) with INR <= 1.5 were safe cutoffs. RESULTS: Overall, 11 patients (7.3%) had post-EVL ulcer bleeding. Bleeding occurred in S patients with Child A/B (4.3%) and 6 patients with Child C (17%) (P = .0174 for Child A/B versus Child C). Eight patients with bleeding were among the 110 below the cutoff for INR and platelet count, whereas only 3 of the patients with bleeding were among the 40 patients with purported high-risk values (P = 1.0). Among the 92 patients with expanded coagulation tests, bleeding occurred in S. There was no difference in any of the coagulation parameters, including overall TEG patterns, between patients who did and did nor bleed. CONCLUSIONS: Post-EVL ulcer bleeding was associated with Child C status but not with conventional or expanded coagulation indices in cirrhotic patients without renal failure or infection undergoing elective EVL. These results call into question the common use of prophylactic procoagulants in the elective setting.
Hip fracture prognosis: could bioimpedance be an alternative to conventional nutritional assessment?
Resumo:
Background: Risk-factors for mortality in hip fractures encompass nutritional status, nominally body mass index, but not body composition. Given the difficulty of anthropometric assessment in bedridden patients a prospective study with bioimpedance analysis was designed. Methods: Elderly patients with hip fracture were consecutively recruited. Biochemical tests, primitive bioimpedance measurements (resistance, reactance and phase angle) and follow-up till one year were targeted. Results: Patients (N = 69, 81.2 +/- 8.1 years old, 72.5% females) stayed in the hospital for 15.5 +/- 17.1 days, and 18.8 %(13/69) required further hospitalization during the ensuing months. Mortality was 11.6% within 30 days, coinciding with hospital mortality, and an additional 11.6% till one year, thus reaching 23.2%. Anemia, hypoalbuminemia and low transferrin, along with elevated glucose and urea were frequent, suggesting undernutrition with metabolic derangements. Reactance, urea and creatinine were different in patients suffering both early and late demise. Resistance, white blood cell count and osteoporosis were risk factors for early mortality only, and anemia exclusively for late mortality. Conclusions: Primitive bioimpedance measurements, which had not been hitherto investigated, were prognostically related to early and late mortality. These markers of disease-related malnutrition and especially reactance should be further studied in patients unfit for anthropometric evaluation due to fracture and immobility.
Resumo:
Background: Several studies have already reported the utilization of fibrin glue in microvascular anastomoses to minimize the number of sutures and to decrease the operative time. Despite the good results obtained in most of these experiments, its clinical application has not launched. The aim of this study was to clarify the controversies around the safeness of fibrin glue application in microvascular anastomoses, and also to demonstrate the potential benefits of fibrin glue application in a realistic free flap model. Methods: Twenty-seven rabbits were used in this study The experimental model consisted of a free groin flap transfer to the anterior cervical region. The flap`s circulation was restored by means of an end-to-side anastomosis between the femoral and carotid arteries, and an end-to-end anastomosis between the femoral and external jugular veins. The animals were divided into two groups (n = 10) according to the anastomosis technique: Group I (conventional suture) and group 11 (fibrin glue). Results: The number of sutures required to complete the arterial and venous anastomoses was reduced in 39 and 37% in group 11, respectively. Despite this reduction, the anastomoses maintained adequate patency rates and mechanical strength. Both arterial and venous anastomoses benefited from fibrin glue application, which made them easier and faster to perform. The flaps` ischemic time and the total operative time were also significantly shortened. Conclusions: In this study, the application of fibrin glue in microvascular anastomoses was safe and reliable. The risk-benefit ratio of fibrin glue application in microvascular anastomoses is favorable for its use. (c) 2008 Wiley-Liss, Inc.
Resumo:
Purpose: The objective of this study is to evaluate blood glucose (BG) control efficacy and safety of 3 insulin protocols in medical intensive care unit (MICU) patients. Methods: This was a multicenter randomized controlled trial involving 167 MICU patients with at least one BG measurement +/- 150 mg/dL and one or more of the following: mechanical ventilation, systemic inflammatory response syndrome, trauma, or burns. The interventions were computer-assisted insulin protocol (CAIP), with insulin infusion maintaining BG between 100 and 130 mg/dL; Leuven protocol, with insulin maintaining BG between 80 and 110 mg/dL; or conventional treatment-subcutaneous insulin if glucose > 150 mg/dL. The main efficacy outcome was the mean of patients` median BG, and the safety outcome was the incidence of hypoglycemia (<= 40 mg/dL). Results: The mean of patients` median BG was 125.0, 127.1, and 158.5 mg/dL for CAIP, Leuven, and conventional treatment, respectively (P = .34, CAIP vs Leuven; P < .001, CAIP vs conventional). In CAIP, 12 patients (21.4%) had at least one episode of hypoglycemia vs 24 (41.4%) in Leuven and 2 (3.8%) in conventional treatment (P = .02, CAIP vs Leuven; P = .006, CAIP vs conventional). Conclusions: The CAIP is safer than and as effective as the standard strict protocol for controlling glucose in MICU patients. Hypoglycemia was rare under conventional treatment. However, BG levels were higher than with IV insulin protocols. (C) 2009 Elsevier Inc. All rights reserved.