961 resultados para CENTERBAND-ONLY DETECTION


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Kinematic functional evaluation with body-worn sensors provides discriminative and responsive scores after shoulder surgery, but the optimal movements' combination has not yet been scientifically investigated. The aim of this study was the development of a simplified shoulder function kinematic score including only essential movements. The P Score, a seven-movement kinematic score developed on 31 healthy participants and 35 patients before surgery and at 3, 6 and 12 months after shoulder surgery, served as a reference.Principal component analysis and multiple regression were used to create simplified scoring models. The candidate models were compared to the reference score. ROC curve for shoulder pathology detection and correlations with clinical questionnaires were calculated.The B-B Score (hand to the Back and hand upwards as to change a Bulb) showed no difference to the P Score in time*score interaction (P > .05) and its relation with the reference score was highly linear (R(2) > .97). Absolute value of correlations with clinical questionnaires ranged from 0.51 to 0.77. Sensitivity was 97% and specificity 94%.The B-B and reference scores are equivalent for the measurement of group responses. The validated simplified scoring model presents practical advantages that facilitate the objective evaluation of shoulder function in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate an automated seizure detection (ASD) algorithm in EEGs with periodic and other challenging patterns. METHODS: Selected EEGs recorded in patients over 1year old were classified into four groups: A. Periodic lateralized epileptiform discharges (PLEDs) with intermixed electrical seizures. B. PLEDs without seizures. C. Electrical seizures and no PLEDs. D. No PLEDs or seizures. Recordings were analyzed by the Persyst P12 software, and compared to the raw EEG, interpreted by two experienced neurophysiologists; Positive percent agreement (PPA) and false-positive rates/hour (FPR) were calculated. RESULTS: We assessed 98 recordings (Group A=21 patients; B=29, C=17, D=31). Total duration was 82.7h (median: 1h); containing 268 seizures. The software detected 204 (=76.1%) seizures; all ictal events were captured in 29/38 (76.3%) patients; in only in 3 (7.7%) no seizures were detected. Median PPA was 100% (range 0-100; interquartile range 50-100), and the median FPR 0/h (range 0-75.8; interquartile range 0-4.5); however, lower performances were seen in the groups containing periodic discharges. CONCLUSION: This analysis provides data regarding the yield of the ASD in a particularly difficult subset of EEG recordings, showing that periodic discharges may bias the results. SIGNIFICANCE: Ongoing refinements in this technique might enhance its utility and lead to a more extensive application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study was performed to evaluate the prevalence of prenatal ultrasound diagnoses for renal anomalies in 20 registries of 12 European countries, and to compare the different prenatal scanning policies. Standardized data were acquired from 709,030 livebirths, stillbirths, and induced abortions during the study period of 2.5 years and transmitted for central analysis. At least one renal malformation was diagnosed in 1130 infants and fetuses. Prenatal diagnosis (PD) was given in 81.8% of all cases, 29% of these pregnancies were terminated. The highest detection rate was reported for unilateral multicystic dysplastic kidneys with 97% (102/105). An early diagnosis was documented for exstrophy of bladder at a mean gestational age of 18.5 weeks. Dilatations of the upper urinary tract were seen late in pregnancy at 28.3 weeks. Terminations of pregnancies (TOP) were performed in 67% (58/86) of the detected bilateral renal agenesis/dysgenesis, but only 4% of the unilateral multicystic dysplastic renal malformations (4/102). In about 1/3 of the cases, renal malformations are within the category of associated malformations, which include multiple non-syndromal malformations, chromosomal aberrations, and non-chromosomal syndromes. Renal malformations were detected in 2/3 of the associated category by the first prenatal ultrasound scan. Detection rates vary in the different countries of the European community due to diverse policies, ethical, and religious background. Countries with no routine ultrasound show the lowest rates in detection, and termination of pregnancy. Prenatally detected renal malformations should result in a careful examination for further anomalies. Prenatal ultrasound fulfills the needs of screening examinations and is a good tool in detecting lethal and severe renal malformations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The CREB-binding protein (CBP) is a large nuclear protein that regulates many signal transduction pathways and is involved in chromatin-mediated transcription. The translocation t(8;16)(p11;p13.3) consistently disrupts two genes: the CBP gene on chromosome band 16p13.3 and the MOZ gene on chromosome band 8p11. Although a fusion of these two genes as a result of the translocation is expected, attempts at detecting the fusion transcript by reverse transcriptase polymerase chain reaction (RT-PCR) have proven difficult; to date, only one in-frame CBP/MOZ fusion transcript has been reported. We therefore sought other reliable means of detecting CBP rearrangements. We applied fluorescence in situ hybridization (FISH) and Southern blot analyses to a series of AML patients with a t(8;16) and detected DNA rearrangements of both the CBP and the MOZ loci in all cases tested. All six cases examined for CBP rearrangements have breakpoints within a 13 kb breakpoint cluster region at the 5' end of the CBP gene. Additionally, we used a MOZ cDNA probe to construct a surrounding cosmid contig and detect DNA rearrangements in three t(8;16) cases, all of which display rearrangements within a 6 kb genomic fragment of the MOZ gene. We have thus developed a series of cosmid probes that consistently detect the disruption of the CBP gene in t(8;16) patients. These clones could potentially be used to screen other cancer-associated or congenital translocations involving chromosome band 16p13.3 as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Plasma adiponectin is strongly associated with various components of metabolic syndrome, type 2 diabetes and cardiovascular outcomes. Concentrations are highly heritable and differ between men and women. We therefore aimed to investigate the genetics of plasma adiponectin in men and women. METHODS: We combined genome-wide association scans of three population-based studies including 4659 persons. For the replication stage in 13795 subjects, we selected the 20 top signals of the combined analysis, as well as the 10 top signals with p-values less than 1.0 x 10(-4) for each the men- and the women-specific analyses. We further selected 73 SNPs that were consistently associated with metabolic syndrome parameters in previous genome-wide association studies to check for their association with plasma adiponectin. RESULTS: The ADIPOQ locus showed genome-wide significant p-values in the combined (p=4.3 x 10(-24)) as well as in both women- and men-specific analyses (p=8.7 x 10(-17) and p=2.5 x 10(-11), respectively). None of the other 39 top signal SNPs showed evidence for association in the replication analysis. None of 73 SNPs from metabolic syndrome loci exhibited association with plasma adiponectin (p>0.01). CONCLUSIONS: We demonstrated the ADIPOQ gene as the only major gene for plasma adiponectin, which explains 6.7% of the phenotypic variance. We further found that neither this gene nor any of the metabolic syndrome loci explained the sex differences observed for plasma adiponectin. Larger studies are needed to identify more moderate genetic determinants of plasma adiponectin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Studies on hexaminolevulinate (HAL) cystoscopy report improved detection of bladder tumours. However, recent meta-analyses report conflicting effects on recurrence. OBJECTIVE: To assess available clinical data for blue light (BL) HAL cystoscopy on the detection of Ta/T1 and carcinoma in situ (CIS) tumours, and on tumour recurrence. DESIGN, SETTING, AND PARTICIPANTS: This meta-analysis reviewed raw data from prospective studies on 1345 patients with known or suspected non-muscle-invasive bladder cancer (NMIBC). INTERVENTION: A single application of HAL cystoscopy was used as an adjunct to white light (WL) cystoscopy. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: We studied the detection of NMIBC (intention to treat [ITT]: n=831; six studies) and recurrence (per protocol: n=634; three studies) up to 1 yr. DerSimonian and Laird's random-effects model was used to obtain pooled relative risks (RRs) and associated 95% confidence intervals (CIs) for outcomes for detection. RESULTS AND LIMITATIONS: BL cystoscopy detected significantly more Ta tumours (14.7%; p<0.001; odds ratio [OR]: 4.898; 95% CI, 1.937-12.390) and CIS lesions (40.8%; p<0.001; OR: 12.372; 95% CI, 6.343-24.133) than WL. There were 24.9% patients with at least one additional Ta/T1 tumour seen with BL (p<0.001), significant also in patients with primary (20.7%; p<0.001) and recurrent cancer (27.7%; p<0.001), and in patients at high risk (27.0%; p<0.001) and intermediate risk (35.7%; p=0.004). In 26.7% of patients, CIS was detected only by BL (p<0.001) and was also significant in patients with primary (28.0%; p<0.001) and recurrent cancer (25.0%; p<0.001). Recurrence rates up to 12 mo were significantly lower overall with BL, 34.5% versus 45.4% (p=0.006; RR: 0.761 [0.627-0.924]), and lower in patients with T1 or CIS (p=0.052; RR: 0.696 [0.482-1.003]), Ta (p=0.040; RR: 0.804 [0.653-0.991]), and in high-risk (p=0.050) and low-risk (p=0.029) subgroups. Some subgroups had too few patients to allow statistically meaningful analysis. Heterogeneity was minimised by the statistical analysis method used. CONCLUSIONS: This meta-analysis confirms that HAL BL cystoscopy significantly improves the detection of bladder tumours leading to a reduction of recurrence at 9-12 mo. The benefit is independent of the level of risk and is evident in patients with Ta, T1, CIS, primary, and recurrent cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The authors examined the relationship of cognitive impairment at hospital admission to 6-month outcome (hospital readmission, nursing home admission, and death) in a cohort of elderly medical inpatients. METHODS: A group of 401 medical inpatients age 75 and older underwent a comprehensive geriatric assessment at hospital admission and were followed up for 6 months. Cognitive impairment was defined as a score <24 on the Mini-Mental State Exam. Detection was assessed through blinded review of discharge summary. Follow-up data were gathered from the centralized billing system (hospital and nursing home admissions) and from proxies (death). RESULTS: Cognitive impairment was present in 129 patients (32.3%). Only 48 (37.2%) were detected; these had more severe impairment than undetected cases. During follow-up, cognitive impairment, whether detected or not, was associated with death and nursing home admission. After adjustment for health, functional, and socioeconomic status, an independent association remained only for nursing home admission in subjects with detected impairment. Those with undetected impairment appeared to be at intermediate risk, but this relationship was not statistically significant. CONCLUSION: In these elderly medical inpatients, cognitive impairment was frequent, rarely detected, and associated with nursing home admission during follow-up. Although this association was stronger in those with detected impairment, these results support the view that acute hospitalization presents an opportunity to better detect cognitive impairment in elderly patients and target further interventions to prevent adverse outcomes such as nursing home admission.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We hypothesized that combining clinical risk factors (CRF) with the heel stiffness index (SI) measured via quantitative ultrasound (QUS) would improve the detection of women both at low and high risk for hip fracture. Categorizing women by risk score improved the specificity of detection to 42.4%, versus 33.8% using CRF alone and 38.4% using the SI alone. This combined CRF-SI score could be used wherever and whenever DXA is not readily accessible. INTRODUCTION AND HYPOTHESIS: Several strategies have been proposed to identify women at high risk for osteoporosis-related fractures; we wanted to investigate whether combining clinical risk factors (CRF) and heel QUS parameters could provide a more accurate tool to identify women at both low and high risk for hip fracture than either CRF or QUS alone. METHODS: We pooled two Caucasian cohorts, EPIDOS and SEMOF, into a large database named "EPISEM", in which 12,064 women, 70 to 100 years old, were analyzed. Amongst all the CRF available in EPISEM, we used only the ones which were statistically significant in a Cox multivariate model. Then, we constructed a risk score, by combining the QUS-derived heel stiffness index (SI) and the following seven CRF: patient age, body mass index (BMI), fracture history, fall history, diabetes history, chair-test results, and past estrogen treatment. RESULTS: Using the composite SI-CRF score, 42% of the women who did not report a hip fracture were found to be at low risk at baseline, and 57% of those who subsequently sustained a fracture were at high risk. Using the SI alone, corresponding percentages were 38% and 52%; using CRF alone, 34% and 53%. The number of subjects in the intermediate group was reduced from 5,400 (including 112 hip fractures) and 5,032 (including 111 hip fractures) to 4,549 (including 100 including fractures) for the CRF and QUS alone versus the combination score. CONCLUSIONS: Combining clinical risk factors to heel bone ultrasound appears to correctly identify more women at low risk for hip fracture than either the stiffness index or the CRF alone; it improves the detection of women both at low and high risk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare the diagnostic value of post-mortem computed tomography angiography (PMCTA) to conventional, ante-mortem computed tomography (CT)-scan, CT-angiography (CTA) and digital subtraction angiography (DSA) in the detection and localization of the source of bleeding in cases of acute hemorrhage with fatal outcomes. The medical records and imaging scans of nine individuals who underwent a conventional, ante-mortem CT-scan, CTA or DSA and later died in the hospital as a result of an acute hemorrhage were reviewed. Post-mortem computed tomography angiography, using multi-phase post-mortem CTA, as well as medico-legal autopsies were performed. Localization accuracy of the bleeding was assessed by comparing the diagnostic findings of the different techniques. The results revealed that data from ante-mortem and post-mortem radiological examinations were similar, though the PMCTA showed a higher sensitivity for detecting the hemorrhage source than did ante-mortem radiological investigations. By comparing the results of PMCTA and conventional autopsy, much higher sensitivity was noted in PMCTA in identifying the source of the bleeding. In fact, the vessels involved were identified in eight out of nine cases using PMCTA and only in three cases through conventional autopsy. Our study showed that PMCTA, similar to clinical radiological investigations, is able to precisely identify lesions of arterial and/or venous vessels and thus determine the source of bleeding in cases of acute hemorrhages with fatal outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Active screening by mobile teams is considered the best method for detecting human African trypanosomiasis (HAT) caused by Trypanosoma brucei gambiense but the current funding context in many post-conflict countries limits this approach. As an alternative, non-specialist health care workers (HCWs) in peripheral health facilities could be trained to identify potential cases who need testing based on their symptoms. We explored the predictive value of syndromic referral algorithms to identify symptomatic cases of HAT among a treatment-seeking population in Nimule, South Sudan. METHODOLOGY/PRINCIPAL FINDINGS: Symptom data from 462 patients (27 cases) presenting for a HAT test via passive screening over a 7 month period were collected to construct and evaluate over 14,000 four item syndromic algorithms considered simple enough to be used by peripheral HCWs. For comparison, algorithms developed in other settings were also tested on our data, and a panel of expert HAT clinicians were asked to make referral decisions based on the symptom dataset. The best performing algorithms consisted of three core symptoms (sleep problems, neurological problems and weight loss), with or without a history of oedema, cervical adenopathy or proximity to livestock. They had a sensitivity of 88.9-92.6%, a negative predictive value of up to 98.8% and a positive predictive value in this context of 8.4-8.7%. In terms of sensitivity, these out-performed more complex algorithms identified in other studies, as well as the expert panel. The best-performing algorithm is predicted to identify about 9/10 treatment-seeking HAT cases, though only 1/10 patients referred would test positive. CONCLUSIONS/SIGNIFICANCE: In the absence of regular active screening, improving referrals of HAT patients through other means is essential. Systematic use of syndromic algorithms by peripheral HCWs has the potential to increase case detection and would increase their participation in HAT programmes. The algorithms proposed here, though promising, should be validated elsewhere.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This project utilized information from ground penetrating radar (GPR) and visual inspection via the pavement profile scanner (PPS) in proof-of-concept trials. GPR tests were carried out on a variety of portland cement concrete pavements and laboratory concrete specimens. Results indicated that the higher frequency GPR antennas were capable of detecting subsurface distress in two of the three pavement sites investigated. However, the GPR systems failed to detect distress in one pavement site that exhibited extensive cracking. Laboratory experiments indicated that moisture conditions in the cracked pavement probably explain the failure. Accurate surveys need to account for moisture in the pavement slab. Importantly, however, once the pavement site exhibits severe surface cracking, there is little need for GPR, which is primarily used to detect distress that is not observed visually. Two visual inspections were also conducted for this study by personnel from Mandli Communications, Inc., and the Iowa Department of Transportation (DOT). The surveys were conducted using an Iowa DOT video log van that Mandli had fitted with additional equipment. The first survey was an extended demonstration of the PPS system. The second survey utilized the PPS with a downward imaging system that provided high-resolution pavement images. Experimental difficulties occurred during both studies; however, enough information was extracted to consider both surveys successful in identifying pavement surface distress. The results obtained from both GPR testing and visual inspections were helpful in identifying sites that exhibited materials-related distress, and both were considered to have passed the proof-of-concept trials. However, neither method can currently diagnose materials-related distress. Both techniques only detected the symptoms of materials-related distress; the actual diagnosis still relied on coring and subsequent petrographic examination. Both technologies are currently in rapid development, and the limitations may be overcome as the technologies advance and mature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ophthalmologists typically acquire different image modalities to diagnose eye pathologies. They comprise, e.g., Fundus photography, optical coherence tomography, computed tomography, and magnetic resonance imaging (MRI). Yet, these images are often complementary and do express the same pathologies in a different way. Some pathologies are only visible in a particular modality. Thus, it is beneficial for the ophthalmologist to have these modalities fused into a single patient-specific model. The goal of this paper is a fusion of Fundus photography with segmented MRI volumes. This adds information to MRI that was not visible before like vessels and the macula. This paper contributions include automatic detection of the optic disc, the fovea, the optic axis, and an automatic segmentation of the vitreous humor of the eye.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS: Removal of colorectal polyps is routinely performed during withdrawal of the endoscope. However, polyps detected during insertion of the colonoscope may be missed at withdrawal. We aimed to evaluate whether polypectomy during both insertion and withdrawal increases polyp detection and removal rates compared with polypectomy at withdrawal only, and to assess the duration of both approaches. PATIENTS AND METHODS: Patients were included into the study when the first polyp was detected, and randomized into two groups; in group A, polyps ≤ 10 mm in diameter were removed during insertion and withdrawal of the colonoscope, while in group B, these polyps were removed at withdrawal only. Main outcome measures were duration of colonoscopy, number of polyps detected during insertion but not recovered during withdrawal, technical ease, patient discomfort, and complications. RESULTS: 150 patients were randomized to group A and 151 to group B. Mean (± standard deviation [SD]) duration of colonoscopy did not differ between the groups (30.8 ± 15.6 min [A] vs. 28.5 ± 13.8 min [B], P = 0.176). In group A 387 polyps (mean 2.58 per colonoscopy) were detected and removed compared with 389 polyps detected (mean 2.58 per colonoscopy) in group B of which 376 were removed (13 polyps were missed, mean size [SD] 3.2 [1.3] mm; 7.3 % of patients). Patient tolerance was similar in the two groups. CONCLUSIONS: Removal of polyps ≤ 10 mm during withdrawal only is associated with a considerable polyp miss rate. We therefore recommend that these polyps are removed during both insertion and withdrawal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes an automatic hand detection system that combines the Fourier-Mellin Transform along with other computer vision techniques to achieve hand detection in cluttered scene color images. The proposed system uses the Fourier-Mellin Transform as an invariant feature extractor to perform RST invariant hand detection. In a first stage of the system a simple non-adaptive skin color-based image segmentation and an interest point detector based on corners are used in order to identify regions of interest that contains possible matches. A sliding window algorithm is then used to scan the image at different scales performing the FMT calculations only in the previously detected regions of interest and comparing the extracted FM descriptor of the windows with a hand descriptors database obtained from a train image set. The results of the performed experiments suggest the use of Fourier-Mellin invariant features as a promising approach for automatic hand detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes an automatic hand detection system that combines the Fourier-Mellin Transform along with other computer vision techniques to achieve hand detection in cluttered scene color images. The proposed system uses the Fourier-Mellin Transform as an invariant feature extractor to perform RST invariant hand detection. In a first stage of the system a simple non-adaptive skin color-based image segmentation and an interest point detector based on corners are used in order to identify regions of interest that contains possible matches. A sliding window algorithm is then used to scan the image at different scales performing the FMT calculations only in the previously detected regions of interest and comparing the extracted FM descriptor of the windows with a hand descriptors database obtained from a train image set. The results of the performed experiments suggest the use of Fourier-Mellin invariant features as a promising approach for automatic hand detection.