190 resultados para CCT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We assessed chromatic discrimination in multiple sclerosis (MS) patients both with (ON) and without (no ON) a history of optic neuritis using the Cambridge color test (CCT). Our goal was to determine the magnitude and chromatic axes of any color vision losses in both patient groups, and to evaluate age-related changes in chromatic discrimination in both patient groups compared to normals. Using the CCT, we measured chromatic discrimination along the protan, deutan and tritan axes in 35 patients with MS (17 ON eyes) and 74 age matched controls. Color thresholds for both patient groups were significantly higher than controls` along the protan and tritan axes (P < 0.001). In addition, the ON and no-ON groups differed significantly along all three-color axes (p < 0.001). MS patients presented a progressive color discrimination impairment with age (along the deutan and tritan axes) that was almost two times faster than controls, even in the absence of ON. These findings suggest that demyelinating diseases reduce sensitivity to color vision in both red-green and blue-yellow axes, implying impairment in both parvocellular and koniocellular visual pathways. The CCT is a useful tool to help characterize vision losses in MS and the relationship between these losses and degree of optic nerve involvement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the visual outcome of chronic occupational exposure to a mixture of organic solvents by measuring color discrimination, achromatic contrast sensitivity and visual fields in a group of gas station workers. We tested 25 workers (20 males) and 25 controls with no history of chronic exposure to solvents (10 males). All participants had normal ophthalmologic exams. Subjects had worked in gas stations on an average of 9.6 +/- 6.2 years. Color vision was evaluated with the Lanthony D15d and Cambridge Colour Test (CCT). Visual field assessment consisted of white-on-white 24-2 automatic perimetry (Humphrey II-750i). Contrast sensitivity was measured for sinusoidal gratings of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 and 20.0 cycles per degree (cpd). Results from both groups were compared using the Mann-Whitney U test. The number of errors in the D15d was higher for workers relative to controls (p<0.01). Their CCT color discrimination thresholds were elevated compared to the control group along the protan, deutan and tritan confusion axes (p<0.01), and their ellipse area and ellipticity were higher (p<0.01). Genetic analysis of subjects with very elevated color discrimination thresholds excluded congenital causes for the visual losses. Automated perimetry thresholds showed elevation in the 9 degrees, 15 degrees and 21 degrees of eccentricity (p<0.01) and in MD and PSD indexes (p<0.01). Contrast sensitivity losses were found for all spatial frequencies measured (p<0.01) except for 0.5 cpd. Significant correlation was found between previous working years and deutan axis thresholds (rho = 0.59; p<0.05), indexes of the Lanthony D15d (rho = 0.52; p<0.05), perimetry results in the fovea (rho = -0.51; p<0.05) and at 3, 9 and 15 degrees of eccentricity (rho = -0.46; p<0.05). Extensive and diffuse visual changes were found, suggesting that specific occupational limits should be created.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ten yeast strains were evaluated concerning their capabilities to assimilate biodiesel-derived glycerol in batch cultivation. The influence of glycerol concentration, temperature, pH and yeast extract concentration on biomass production was studied for the yeast selected. Further, the effect of agitation on glycerol utilization by the yeast Hansenula anomala was also studied. The yeast H. anomala CCT 2648 showed the highest biomass yield (0.30 g g(-1)) and productivity (0.19 g L-1 h(-1)). Citric acid, succinic acid, acetic acid and ethanol were found as the main metabolites produced. The increase of yeast extract concentration from 1 to 3 g L-1 resulted in high biomass production. The highest biomass concentration (21 g L-1), yield (0.45 g g(-1)) and productivity (0.31 g L-1 h(-1)), as well as ribonucleotide production (13.13 mg g(-1)), were observed at 700 rpm and 0.5 vvm. These results demonstrated that glycerol from biodiesel production process showed to be a feasible substrate for producing biomass and ribonucleotides by yeast species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'indagine ha riguardato il profilo del vento nei primi 30 metri dello strato limite atmosferico stabile nell'ambito della teoria di similarità locale. Ad oggi, diversi esperimenti hanno confermato la validità della teoria per strati-limite su terreni livellati e superfici omogenee. Tali condizioni ideali sono però infrequenti nella realtà ed è perciò importante capire quali siano i limiti della similarità locale per strati-limite su terreni complessi e superfici disomogenee. Entrambe le condizioni sono presenti a Ny-Alesund (Svalbard, Norvegia) dove il Consiglio Nazionale delle Ricerche (CNR), nel 2009, ha installato una torre di 30 m, la Amudsen-Nobile Climate Change Tower (CCT), per lo studio dello strato-limite artico. Il lavoro di tesi ha riguardato misure di vento e turbolenza acquisite sulla CCT da maggio 2012 a maggio 2014. Il confronto tra le velocità del vento misurate dagli anemometri installati sulla CCT, ha rivelato criticità nel dato sonico manifestatesi con sovrastime sistematiche e maggiore erraticità rispetto alle misure provenienti dagli anemometri a elica. Un test condotto fra diversi metodi per il calcolo dei gradienti verticali della velocità del vento ha rivelato scarsa sensibilità dei risultati ottenuti al particolare metodo utilizzato. Lo studio ha riguardato i gradienti verticali adimensionali della velocità del vento nei primi 30-m dello strato limite stabile. Deviazioni significative tra i tra le osservazioni e i valori predetti dalla similarità locale sono state osservate in particolare per i livelli più distanti dal suolo e per valori crescenti del parametro di stabilità z/L (L, lunghezza di Obukhov locale). In particolare, si sono osservati gradienti adimensionali inferiori a quelli predetti dalle più usate relazioni di flusso-gradiente. Tali deviazioni, presenti perlopiù per z/L>0.1, sono state associate ad un effetto di accentuazione della turbolenza da parte delle irregolarità del terreno. Per condizioni meno stabili, z/L<0.1, scarti positivi tra i gradienti osservati e quelli attesi sono stati attribuiti alla formazione di strati limite interni in condizioni di vento dal mare verso la costa. Sono stati proposti diversi metodi per la stima dell'effetto della self-correlazione nella derivazione delle relazioni di flusso-gradiente, dovuta alla condivisione della variabile u*. La formula per il coefficiente lineare di self correlazione e le sue distribuzioni di probabilità empiriche sono state derivate e hanno permesso di stimare il livello di self-correlazione presente nel dataset considerato.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cranial CT (CCT) is the gold standard to rule out traumatic brain injury. The serum level of the protein S-100B has recently been proposed as promising marker of traumatic brain injury. We prospectively investigated whether it might be a reliable tool for CCT triage in mild brain injury at a peripheral trauma centre with limited CT resources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has been shown that the pressure-to-cornea index (PCI), which estimates the relative effects of intraocular pressure (IOP) and central corneal thickness (CCT), may differentiate between glaucoma and non-glaucoma states. The authors investigated the utility of the pressure-cornea-vascular index (PCVI) in predicting field-progression in patients with normal tension glaucoma (NTG).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To determine the practicability and accuracy of central corneal thickness (CCT) measurements in living chicks utilizing a noncontact, high-speed optical low-coherence reflectometer (OLCR) mounted on a slit lamp. ANIMALS STUDIED Twelve male chicks (Gallus gallus domesticus). Procedures  Measurements of CCT were obtained in triplicate in 24 eyes of twelve 1-day-old anaesthetized chicks using OLCR. Every single measurement taken by OLCR consisted of the average result of 20 scans obtained within seconds. Additionally, corneal thickness was determined histologically after immersion fixation in Karnovsky's solution alone (20 eyes) or with a previous injection of the fixative into the anterior chamber before enucleation (4 eyes). RESULTS Central corneal thickness measurements using OLCR in 1-day-old living chicks provide a rapid and feasible examination technique. Mean CCT measured with OLCR (189.7 ± 3.34 μm) was significantly lower than histological measurements (242.1 ± 47.27 μm) in eyes with fixation in Karnovsky's solution (P = 0.0005). In eyes with additional injection of Karnovsky's fixative into the anterior chamber, mean histologically determined CCT was 195.2 ± 8.25 μm vs. 191.9 ± 8.90 μm with OLCR. A trend for a lower variance was found compared to the eyes that had only been immersion fixed. CONCLUSION Optical low-coherence reflectometry is an accurate examination technique to measure in vivo CCT in the eye of newborn chicks. The knowledge of the thickness of the chick cornea and the ability to obtain noninvasive, noncontact measurements of CCT in the living animal may be of interest for research and development of eye diseases in chick models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. To guide the administration of blood products, coagulation screening of trauma patients should be fast and accurate. The purpose of this study was to identify the correlation between CCT and TEG in trauma, to determine which CCT or TEG parameter is most sensitive in predicting transfusion in trauma, and to define TEG cut-off points for trauma care. Methods. A six-month, prospective observational study of 76 adult patients with suspected multiple injuries was conducted at a Level 1 trauma centre of a university hospital. Physicians blinded to TEG results made the decision to transfuse based on clinical evaluation. Results. The study results showed that conventional coagulation tests correlate moderately with Rapid TEG parameters (R: 0.44–0.61). Kaolin and Rapid TEG were more sensitive than CCTs, and the Rapid TEG α-Angle was identified as the single parameter with the greatest sensitivity (84%) and validity (77%) at a cut-off of 74.7 degrees. When the Rapid TEG α-Angle was combined with heart rate >75 bpm, or haematocrit < 41%, sensitivity (84%, 88%) and specificity (75%, 73%) were improved. Conclusion. Cutoff points for transfusion can be determined with the Rapid TEG α-Angle and can provide better sensitivity than CCTs, but a larger study population is needed to reproduce this finding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Globalisation in coronary stent research calls for harmonization of clinical endpoint definitions and event adjudication. Little has been published about the various processes used for event adjudication or their impact on outcome reporting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND/AIMS: Rebound tonometry (RT) is performed without anaesthesia with a hand held device. The primary aim was to compare RT with Goldmann applanation tonometry (GAT) and to correlate with central corneal thickness (CCT). The secondary aim was to prove tolerability and practicability of RT under "study conditions" and "routine practice conditions." METHODS: In group 1 (52 eyes/28 patients), all measurements were taken by the same physician, in the same room and order: non-contact optical pachymetry, RT, slit lamp inspection, GAT. Patients were questioned about discomfort or pain. In group 2 (49 eyes/27 patients), tonometry was performed by three other physicians during routine examinations. RESULTS: RT was well tolerated and safe. Intraocular pressure (IOP) ranged between 6 mm Hg and 48 mm Hg. No different trends were found between the groups. RT tended to give slightly higher readings: n = 101, mean difference 1.0 (SD 2.17) mm Hg; 84.1% of RT readings within plus or minus 3 mm Hg of GAT; 95% confidence interval in the Bland-Altman analysis -3.2 mm Hg to +5.2 mm Hg. Both RT and GAT showed a weak positive correlation with CCT (r2 0.028 and 0.025, respectively). CONCLUSIONS: RT can be considered a reliable alternative for clinical screening and in cases where positioning of the head at the slit lamp is impossible or topical preparations are to be avoided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: There is an increasing demand for comprehensive forms of palliative cancer care, meeting physical as well as emotional, cognitive, spiritual and social needs. Therapy programs of anthroposophic hospitals are aimed at improving health and quality of life (QoL) at these levels. However, data on the influence of these programs on QoL of patients with advanced cancer are scarce. PATIENTS AND METHODS: 144 in-patients with advanced epithelial cancers were treated at the anthroposophic Lukas Klinik, Arlesheim, Switzerland. QoL was assessed upon admission, discharge and after 4 months, using 20 functional scales from the questionnaires EORTC QLQ-C30, HADS and SELT-M. Statistical testing was performed with the Wilcoxon signed rank test. At month 4, subjectively perceived benefits from anthroposophic medicine (AM) and conventional cancer therapy (CCT) were assessed by telephone. OBJECTIVE: The aim was to provide an account of global, physical, emotional, cognitive-spiritual and social QoL developments in advanced cancer patients, during and after in-patient AM treatment, and to investigate subjective benefits from AM and CCT. RESULTS: QoL improvements were observed in all 20 dimensions (12 significant). Compared to related studies, improvements were fairly high. At month 4, QoL scores had decreased but were still above baseline in all 20 dimensions. Both AM and CCT were perceived as beneficial. CONCLUSION: Our data provide evidence that in-patient therapy at an anthroposophic hospital can lead to significant QoL improvements, especially in emotional, but also global, physical, cognitive-spiritual and social aspects. Benefits of AM were experienced on the physical, emotional, cognitive- spiritual and social level. Benefits of CCT were tumor-focused.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Several conversion tables and formulas have been suggested to correct applanation intraocular pressure (IOP) for central corneal thickness (CCT). CCT is also thought to represent an independent glaucoma risk factor. In an attempt to integrate IOP and CCT into a unified risk factor and avoid uncertain correction for tonometric inaccuracy, a new pressure-to-cornea index (PCI) is proposed. METHODS: PCI (IOP/CCT(3)) was defined as the ratio between untreated IOP and CCT(3) in mm (ultrasound pachymetry). PCI distribution in 220 normal controls, 53 patients with normal-tension glaucoma (NTG), 76 with ocular hypertension (OHT), and 89 with primary open-angle glaucoma (POAG) was investigated. PCI's ability to discriminate between glaucoma (NTG+POAG) and non-glaucoma (controls+OHT) was compared with that of three published formulae for correcting IOP for CCT. Receiver operating characteristic (ROC) curves were built. RESULTS: Mean PCI values were: Controls 92.0 (SD 24.8), NTG 129.1 (SD 25.8), OHT 134.0 (SD 26.5), POAG 173.6 (SD 40.9). To minimise IOP bias, eyes within the same 2 mm Hg range between 16 and 29 mm Hg (16-17, 18-19, etc) were separately compared: control and NTG eyes as well as OHT and POAG eyes differed significantly. PCI demonstrated a larger area under the ROC curve (AUC) and significantly higher sensitivity at fixed 80% and 90% specificities compared with each of the correction formulas; optimum PCI cut-off value 133.8. CONCLUSIONS: A PCI range of 120-140 is proposed as the upper limit of "normality", 120 being the cut-off value for eyes with untreated pressures or=22 mm Hg. PCI may reflect individual susceptibility to a given IOP level, and thus represent a glaucoma risk factor. Longitudinal studies are needed to prove its prognostic value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Noninvasive intraocular pressure (IOP) measurement in mice is critically important for understanding the pathophysiology of glaucoma. Rebound tonometry is one of the methods that can be used for obtaining such measurements. We evaluated the ability of the rebound tonometer (RT) to determine IOP differences among various mouse strains and whether differences in corneal thickness may affect IOP measurements in these animals. MATERIALS AND METHODS: Five different commonly used mouse strains (BALB/C, CBA/CAHN, AKR/J, CBA/J, and 129P3/J) were used. IOP was measured in eyes from 12 nonsedated animals (6 male and 6 female) from each strain at 2 to 3 months of age using the RT. IOPs were measured in all animals, on 2 different days between 10 AM and 12 PM. Subsequently, a number of eyes from each strain were cannulated to provide a calibration curve specific for that strain. Tonometer readings for all strains were converted to apparent IOP values using the calibration data obtained from the calibration curve of the respective strain. For comparison purposes, IOP values were also obtained using the C57BL/6 calibration data previously reported. IOP for the 5 strains, male and female animals, and the different occasion of measurement were compared using repeat measures analysis of variance. The central corneal thickness (CCT) of another group of 8 male animals from each of the 5 strains was also measured using an optical low coherence reflectometry (OLCR) pachymeter modified for use with mice. CCT values were correlated to mean IOPs of male animals and to the slopes and intercept of individual strain calibration curves. RESULTS: Noninvasive IOP measurements confirm that the BALB/C strain has lower and the CBA/CAHN has higher relative IOPs than other mouse strains while the AKR/J, the CBA/J, and the 129P3/J strains have intermediate IOPs. There is a very good correlation of apparent IOP values obtained by RT with previously reported true IOPs obtained by cannulation. There was a small but statistically significant difference in IOP between male and female animals in 2 strains (129P3/J and AKR/J) with female mice having higher relative IOPs. No correlation between CCT and IOP was detected. CCT did not correlate with any of the constants describing the calibration curves in the various strains. CONCLUSIONS: Noninvasive IOP measurement in mice using the RT can be used to help elucidate IOP phenotype, after prior calibration of the tonometer. CCT has no effect on mouse IOP measurements using the RT.