979 resultados para CARDIAC OUTPUT


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Heart failure has been divided into several different forms depending on etiology, clinical course and pathophysiology of left ventricular (LV) dysfunction. Systolic and diastolic dysfunction are characterized by a reduced cardiac output with normal (= diastolic dysfunction) or depressed (= systolic dysfunction) LV pump function. New diagnostic techniques such as magnetic resonance imaging (MRI) allow to determine noninvasively LV 3D motion by labelling specific myocardial regions (= myocardial "tagging") with a rectangular or radial grid. From the deformation of this grid rotational and translational motion of the heart can be derived. A "wringing" motion of the left ventricle has been described during systole which includes a clockwise rotation at the base and a counterclockwise rotation at the apex. During diastole, an "untwisting" motion has been demonstrated. In the normal heart, diastolic "untwisting" occurs primarily during isovolumic relaxation, analogous to the systolic "wringing" which takes place mainly during isovolumic contraction. A prolongation of the "untwisting" motion was found in the hypertrophied (aortic stenosis) and hibernating myocardium. Thus, heart failure is associated with profound alterations in the mechanical function of the heart which are manifested by changes in systolic "wringing" and diastolic "untwisting" motion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the cardiovascular effects of sodium bicarbonate in neonates with metabolic acidosis. DESIGN: Prospective, open, non-randomized, before-after intervention study with hemodynamic measurements performed before and 1, 5, 10, 20, and 30 min after bicarbonate administration. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 16 paralysed and mechanically ventilated newborn infants with a metabolic acidosis (pH < 7.25 in premature and < 7.30 in term infants, base deficit > -8). INTERVENTION: An 8.4% sodium bicarbonate solution diluted 1:1 with water (final osmolality of 1000 mOsm/l) was administered in two equal portions at a rate of 0.5 mmol/min. The dose in mmol was calculated using the formula "base deficit x body weight (kg) x 1/3 x 1/2". MEASUREMENTS AND RESULTS: Sodium bicarbonate induced a significant but transient rise in pulsed Doppler cardiac output (CO) (+27.7%), aortic blood flow velocity (+15.3%), systolic blood pressure (BP) (+9.3%), (+14.6%), transcutaneous carbon dioxide pressure (PtcCO2) (+11.8%), and transcutaneous oxygen pressure (PtcO2) (+8%). In spite of the PaCO2 elevation, pH significantly improved (from a mean of 7.24 to 7.30), and the base deficit decreased (-39.3%). Calculated systemic vascular resistance (SVR) (-10.7%) and diastolic BP (-11.7%) decreased significantly, while PaO2 and heart rate (HR) did not change. Central venous pressure (CVP) (+6.5%) increased only slightly. By 30 min after bicarbonate administration all hemodynamic parameters, with the exception of the diastolic BP, had returned to baseline. CONCLUSION: Sodium bicarbonate in neonates with metabolic acidosis induces an increase in contractility and a reduction in afterload.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Marrow radioiron uptake and marrow blood flow were measured in order to evaluate iron supply for erythropoiesis. Normal, phenylhydrazine-treated and bled animals were studied. The plasma iron turnover of seven normal rabbits was 1.49 +/- 0.22 mg/dl whole blood per d, of 11 rabbits treated 4 d before with phenylhydrazine was 5.16 +/- 1.81, and of four bled animals the plasma iron turnover was 3.75 +/- 1.61. The cardiac output and the percentage of blood flow to the marrow was increased in phenylhydrazine-treated and bled animals. Marrow iron flow in phenylhydrazine-treated animals was 38.3 +/- 32.6 micrograms/min per kg as compared with control values of 7.0 +/- 1.3 (P less than 0.01). This was due to an increase in marrow flow, an increase in plasma iron, and an increase in plasmatocrit. In bled animals, in spite of an increased marrow blood flow, marrow iron flow of 7.3 +/- 2.2 was similar to that of control animals due to a lower plasma iron concentration. The calculated marrow iron extraction of 3.7 +/- 2.4% in phenylhydrazine-treated animals was not different from that of control animals of 4.3 +/- 1.1, whereas extraction was increased in bled animals to 7.9 +/- 1.3 (P less than 0.01). In additional studies of transfused animals, acutely induced anemia was associated with an increased cardiac output, but also with a relative decrease in marrow flow, which left marrow iron supply unaffected. It would appear from these studies that an important mechanism for meeting the increased iron requirement of the hyperplastic erythroid marrow is an increase in marrow blood flow.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction Exposure to hypoxia leads to several reactions of the organism, which try to compensate the reduced oxygen level in the blood. Acute response is characterized by an increase in pulmonary ventilation (Hypoxia Ventilatory Response, HVR) and in cardiac output (cardiac response to hypoxia). Heart rate (HR) at rest and during exercise is higher at high altitude than at sea level, whereas HRmax is lower. These cardiac adaptations are partially explained by an increased sympathetic stimulation associated with a reduced parasympathetic tone (12). The precise mechanisms of HRmax decline in acute hypoxia are however still to be identified, although several hypothesis have been suggested, such as a direct effect of hypoxia on the electrophysiological properties, an influence of skeletal maximal VO2 or a modulation of the autonomic nervous system (8). Some authors have reported that endurance trained athletes present an increased sensitivity to hypoxia shown by a large reduction in VO2max and an important decrease in arterial saturation. (9,11, 13) A hypoxia test can assess the sensibility of chemoreceptors to the reduction of oxygen by calculating hypoxic ventilatory and cardiac responses, knowing that low sensibility is correlated with poor acclimatization. Two parameters results from the differences in ventilation (and heart rate) divided by the difference in the arterial oxygen saturation between normoxia and hypoxia (18). Objective The hypothesis tested by this study is that parasympathetic reactivation after moderate effort in hypoxic condition can be used as a marker of individual sensibility to hypoxia. Parasympathetic reactivation is a marker of vagal tone that predict endurance capacity and aerobic fitness (2,7). Methods Subjects This study uses data obtained from two groups of athletes participating into two larger studies about adaptation to hypoxia. One group is composed of elite athletes (Swiss ski mountaineering team), the other one of mid-level athletes (ski mountaineering amateurs). The particularity of this target population is that they often train at high altitude, and therefore could show a better response to hypoxia than athleltes of other disciplines. Protocol The athletes performed a submaximal exercise (6min run at 9 km/h, flat) followed by 10 min of seated rest either in an hypoxic chamber (simulated altitude of 3000m) or in normoxic conditions. During the resting phase parasympathetic reactivation was assessed by beat-to-beat HR measurements.A test of tolerance to altitude was also performed. Analysis Parasympathetic reactivation, assessed by the calculation of the root mean square of successive differences in the R-R intervals (RMSSD)(4), is compared to individual responses at altitude, in order to appreciate the correlation between the two phenomena.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sixteen patients with refractory hypertension were submitted to vigorous sodium depletion while cardiovascular homeostasis was monitored with measurements of hormonal and hemodynamic parameters and repeat saralasin tests. This regimen resulted in a negative sodium balance by an average of 300 mEq. The loss of sodium closely correlated to the decrease of body weight (r = 0.70, p less than 0.005). Blood pressure (BP) decreased from 176/166 +/- 8/3 to 155/109 +/-6/3 mm Hg. There was a significant correlation between percent increments in plasma renin activity (PRA) and the rise in plasma norepinephrine (r = 0.68, p less than 0.05) and a close negative correlation between percent increase in PRA and the ratio of fall in mean blood pressure (MAP) per unit of weight loss (r = -0.73, p less than 0.005). Thus, patients with the least percent increase in PRA demonstrated the greatest fall in BP per unit of weight loss, indicating that relative rather than absolute elevation of renin may be the factor limiting antihypertensive efficacy of sodium depletion. Sodium depletion induced increase in peripheral resistance and decrease in cardiac output, both mostly attributable to relative hyperreninemia. Indeed, the adverse hemodynamic changes were reversed by angiotensin inhibition, during which BP normalized. It is concluded that vigorous sodium depletion complemented by angiotensin blockade or suppression with sympatholytic agents improves management of otherwise refractory hypertension.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Compartmental and physiologically based toxicokinetic modeling coupled with Monte Carlo simulation were used to quantify the impact of biological variability (physiological, biochemical, and anatomic parameters) on the values of a series of bio-indicators of metal and organic industrial chemical exposures. A variability extent index and the main parameters affecting biological indicators were identified. Results show a large diversity in interindividual variability for the different categories of biological indicators examined. Measurement of the unchanged substance in blood, alveolar air, or urine is much less variable than the measurement of metabolites, both in blood and urine. In most cases, the alveolar flow and cardiac output were identified as the prime parameters determining biological variability, thus suggesting the importance of workload intensity on absorbed dose for inhaled chemicals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Home hospital is advocated in many western countries in spite of limited evidence of its economic advantage over usual hospital care. Heart failure and community-acquired pneumonia are two medical conditions which are frequently targeted by home hospital programs. While recent trials were devoted to comparisons of safety and costs, the acceptance of home hospital for patients with these conditions remains poorly described. OBJECTIVE: To document the medical eligibility and final transfer decision to home hospital for patients hospitalized with a primary diagnosis of heart failure or community-acquired pneumonia. DESIGN: Longitudinal study of patients admitted to the medical ward of acute care hospitals, up to the final decision concerning their transfer. SETTING: Medical departments of one university hospital and two regional teaching Swiss hospitals. PATIENTS: All patients admitted over a 9 month period to the three settings with a primary diagnosis of heart failure (n= 301) or pneumonia (n=441). MEASUREMENTS: Presence of permanent exclusion criteria on admission; final decision of (in)eligibility based on medical criteria; final decision regarding the transfer, taking into account the opinions of the family physician, the patient and informal caregivers. RESULTS: While 27.9% of heart failure and 37.6% of pneumonia patients were considered to be eligible from a medical point of view, the program acceptance by family physicians, patients and informal caregivers was low and a transfer to home hospital was ultimately chosen for just 3.8% of heart failure and 9.6% of pneumonia patients. There were no major differences between the three settings. CONCLUSIONS: In the case of these two conditions, the potential economic advantage of home hospital over usual inpatient care is compromised by the low proportion of patients ultimately transferred.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effects of the sympathetic activation elicited by a mental stress on insulin sensitivity and energy expenditure (VO(2)) were studied in 11 lean and 8 obese women during a hyperinsulinemic-euglycemic clamp. Six lean women were restudied under nonselective beta-adrenergic blockade with propranolol to determine the role of beta-adrenoceptors in the metabolic response to mental stress. In lean women, mental stress increased VO(2) by 20%, whole body glucose utilization ([6,6-(2)H(2)]glucose) by 34%, and cardiac index (thoracic bioimpedance) by 25%, whereas systemic vascular resistance decreased by 24%. In obese women, mental stress increased energy expenditure as in lean subjects, but it neither stimulated glucose uptake nor decreased systemic vascular resistance. In the six lean women who were restudied under propranolol, the rise in VO(2), glucose uptake, and cardiac output and the decrease in systemic vascular resistance during mental stress were all abolished. It is concluded that 1) in lean subjects, mental stress stimulates glucose uptake and energy expenditure and produces vasodilation; activation of beta-adrenoceptors is involved in these responses; and 2) in obese patients, the effects of mental stress on glucose uptake and systemic vascular resistance, but not on energy expenditure, are blunted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to assess whether metabolic syndrome (MetSyn) predicts a higher risk for cardiovascular events in older adults. BACKGROUND: The importance of MetSyn as a risk factor has not previously focused on older adults and deserves further study. METHODS: We studied the impact of MetSyn (38% prevalence) on outcomes in 3,035 participants in the Health, Aging, and Body Composition (Health ABC) study (51% women, 42% black, ages 70 to 79 years). RESULTS: During a 6-year follow-up, there were 434 deaths overall, 472 coronary events (CE), 213 myocardial infarctions (MI), and 231 heart failure (HF) hospital stays; 59% of the subjects had at least one hospital stay. Coronary events, MI, HF, and overall hospital stays occurred significantly more in subjects with MetSyn (19.9% vs. 12.9% for CE, 9.1% vs. 5.7% for MI, 10.0% vs. 6.1% for HF, and 63.1% vs. 56.1% for overall hospital stay; all p < 0.001). No significant differences in overall mortality was seen; however, there was a trend toward higher cardiovascular mortality (5.1% vs. 3.8%, p = 0.067) and coronary mortality (4.5% vs. 3.2%, p = 0.051) in patients with MetSyn. After adjusting for baseline characteristics, patients with MetSyn were at a significantly higher risk for CE (hazard ratio [HR] 1.56, 95% confidence interval [CI] 1.28 to 1.91), MI (HR 1.51, 95% CI 1.12 to 2.05), and HF hospital stay (HR 1.49, 95% CI 1.10 to 2.00). Women and whites with MetSyn had a higher coronary mortality rate. The CE rate was higher among subjects with diabetes and with MetSyn; those with both had the highest risk. CONCLUSIONS: Overall, subjects over 70 years are at high risk for cardiovascular events; MetSyn in this group is associated with a significantly greater risk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: Levosimendan, a calcium-sensitizing agent has been reported as useful for the management of patients with low cardiac output state. We report here our experience, safety and efficacy of use of levosimendan as rescue therapy after surgery for congenital heart disease. Methods: Retrospective cohort study on patients necessitating levosimendan therapy for post operative low cardiac output or severe post operative systolic and diastolic dysfunction. Twelve patients with a mean age of 2.1 years (range 7 days - 14 years old) received levosimendan. Type of surgery: 3 arterial switch, 3 correction of complete abnormal pulmonary venous return, 3 closure of VSD and correction of aortic coarctation, 3 Tetralogy of Fallot, one correction of truncus arteriosus and one palliation for single ventricle. The mean time of ECC was 203 +/- 81min. Ten patients received levosimendan for low cardiac output not responding to conventional therapy in these cases (milrinone, dopamine and noradrenaline) in the first 6 hours following entry in the ICU and 3 patients received levosimendan 3-4 days after surgery for severe systolic and diastolic dysfunction. Levosimendan was given as a drip for 24-48 hours at the dose of 0.1-0.2 mcg/ kg/min, without loading dose. Results: Significant changes were noted on mean plasmatic lactate (3.3 +/- 1.7mmole/L vs 1.8 +/-0.6mmole/L, p+0.01), mean central venous saturation (55 +/- 11% vs 68 +/- 10%, p+0.01) and mean arterio-venous difference in CO2 (9.6 +/- 4.9mmHg vs 6.7 +/- 2.1mmHg, p+0.05) for values before and at the end of levosimendan administration. There was no significant changes on heart rate, systolic pressure or central venous pressure. No adverse effect was observed. Conclusion: Levosimendan, used as rescue therapy after surgery for congenital heart disease, is safe and improves cardiac output as demonstrated with improvement of parameters commonly used clinically.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of the study was to evaluate the tissue oxygenation and hemodynamic effects of NOS inhibition in clinical severe septic shock. Eight patients with septic shock refractory to volume loading and high level of adrenergic support were prospectively enrolled in the study. Increasing doses of NOS inhibitors [N(G)-nitro-L-arginine-methyl ester (L-NAME) or N(G)-monomethyl-L-arginine (L-NMMA)] were administered as i.v. bolus until a peak effect = 10 mmHg on mean blood pressure was obtained or until side effects occurred. If deemed clinically appropriate, a continuous infusion of L-NAME was instituted and adrenergic support weaning attempted. The bolus administration of NOS inhibitors transiently increased mean blood pressure by 10 mm Hg in all patients. Seven out of eight patients received an L-NAME infusion, associated over 24 h with a progressive decline in cardiac index (P < 0.001) and an increase in systemic vascular resistance (P < 0.01). Partial or total adrenergic support weaning was rapidly possible in 6/8 patients. Oxygen transport decreased (P < 0.001), but oxygen consumption remained unchanged in those patients in whom it could be measured by indirect calorimetry (5/8). Blood lactate and the difference between tonometric gastric and arterial PCO2 remained unchanged. There were 4/8 ICU survivors. We conclude that nitric oxide synthase inhibition in severe septic shock was followed with a progressive correction of the vasoplegic hemodynamic disturbances with finally normalization of cardiac output and systemic vascular resistances without any demonstrable deterioration in tissue oxygenation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to compare O2 consumption (VO2) determination by the gas-exchange (VO2GE) and Fick (VO2F) methods in cardiac surgical patients. A total of 10 mechanically ventilated postoperative patients were studied prospectively. Thermodilution was performed using three randomly applied techniques: room temperature saline injected at end expiration, room temperature saline randomly injected in the respiratory cycle, and iced saline injected at end expiration. The influence of the number of thermodilution determinations was assessed by comparing results from 2 and 10 injections. The variability of VO2F was greater than that of VO2GE. There was no bias between VO2GE and VO2F values using injectate at room temperature. Accuracy and precision were not improved by increasing the number of cardiac output determinations from 2 to 10. A significant bias was observed using ice-cold injectate, VO2F being 18.0 +/- 15.4 ml/min/m2 lower than VO2GE (p = 0.001). Published results when comparing VO2F and VO2GE are discrepant. However, a significant bias was found in all studies using cold injectate, with lower VO2F values. We conclude that iced injectate should not be used to assess VO2 in critically ill patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: Low tidal volume ventilation and permissive hypercapnia are required in patients with sepsis complicated by ARDS. The effects of hypercapnia on tissue oxidative metabolism in this setting are unknown. We therefore determined the effects of moderate hypercapnia on markers of systemic and splanchnic oxidative metabolism in an animal model of endotoxemia. METHODS: Anesthetized rats maintained at a PaCO(2) of 30, 40 or 60 mmHg were challenged with endotoxin. A control group (PaCO(2) 40 mmHg) received isotonic saline. Hemodynamic variables, arterial lactate, pyruvate, and ketone bodies were measured at baseline and after 4 h. Tissue adenosine triphosphate (ATP) and lactate were measured in the small intestine and the liver after 4 h. RESULTS: Endotoxin resulted in low cardiac output, increased lactate/pyruvate ratio and decreased ketone body ratio. These changes were not influenced by hypercapnia, but were more severe with hypocapnia. In the liver, ATP decreased and lactate increased independently from PaCO(2) after endotoxin. In contrast, the drop of ATP and the rise in lactate triggered by endotoxin in the intestine were prevented by hypercapnia. CONCLUSIONS: During endotoxemia in rats, moderate hypercapnia prevents the deterioration of tissue energetics in the intestine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Patients with chronic heart failure who are not eligible for heart transplant and whose life expectancy depends mainly on the heart disease may benefit from mechanical circulatory support. Mechanical circulatory support restores adequate cardiac output and organ perfusion and eventually improves patients' clinical condition, quality of life and life expectancy. This treatment is called destination therapy (DT) and we estimate that in Switzerland more than 120 patients per year could benefit from it. In the last 10 years, design of the devices, implantation techniques and prognoses have changed dramatically. The key to successful therapy with a left ventricular assist device is appropriate patient selection, although we are still working on the definition of reliable inclusion and exclusion criteria and optimal timing for surgical implantation. Devices providing best long-term results are continuous flow, rotary or axial blood pumps implanted using minimally invasive techniques on a beating heart. These new devices (Thoratec HeartMate II and HeartWare HVAD) have only a single moving part, and have improved durability with virtually 10 years freedom from mechanical failure. In selected patients, the overall actuarial survival of DT patients is 75% at 1 year and 62% at 2 years, with a clear improvement in quality of life compared with medical management only. Complications include bleeding and infections; their overall incidence is significantly lower than with previous devices and their management is well defined. DT is evolving into an effective and reasonably cost-effective treatment option for a growing population of patients not eligible for heart transplant, showing encouraging survival rates at 2 years and providing clear improvement in quality of life. The future is bright for people suffering from chronic heart failure.