899 resultados para Building Performance
Resumo:
Purpose – The paper aims to present the findings of a “situation review” of the Energy Performance of Buildings Directive (EPBD), focusing on energy performance certificates (EPCs) to highlight areas of specific importance for the UK property investment community. The paper is based on research commissioned by the Investment Property Forum (IPF) and funded through the IPF Research Programme (2006-2009). Design/methodology/approach – Interviews were undertaken with experts from the fields of property investment and building engineering. The interviews were undertaken with to identify: the current knowledge of EPCs in the property investment sector; key issues with practical implementation of the legislation; and perceptions of the potential impacts of legislation, particularly in relation to value stakeholder and behaviour. Findings – The paper finds that, although the regulations have been published, there is still a need for clarification in the marketplace with regard to some of the detail of regulations and the certification process. The following areas are of most concern to property investors: costs of surveys; potential difficulties with the process; and a shortage of assessors. With respect to these impacts it is becoming clear that investors who have not yet started considering the EPBD and its requirements within their strategy are likely to face difficulties in the short term. The most significant value-related impacts of EPBD are expected to be value differentiation of properties and “price chipping” against the rental or capital value of the property, where an occupier or potential purchaser will use the recommendations contained within an EPC to force a reduction in value. The latter is expected to emerge in the short term, whereas the former is expected to be realised over the medium to long term. Both these impacts have potentially significant implications for property investment holdings and also future investment behaviour.
Resumo:
Unlike corporate and business levels, there is little research examining corporate responsibility (CR) at the functional level of the firm including supply chain strategy. The results of a firm-level survey show that CR internal awareness, and monitoring CR performance are positively related to the supply chain partnership approach, however sharing CR best practices is negatively associated. Furthermore, the impact of CR on firm performance is mediated by the functional behaviour of supply chain partnership formation. Our study provides support for including CR awareness building and monitoring in the development of partnerships but cautions against imposing CR best practices on suppliers.
Resumo:
There is growing pressure on the construction industry to deliver energy efficient, sustainable buildings but there is evidence to suggest that, in practice, designs regularly fail to achieve the anticipated levels of in-use energy consumption. One of the key factors behind this discrepancy is the behavior of the building occupants. This paper explores how insights from experimental psychology could potentially be used to reduce the gap between the predicted and actual energy performance of buildings. It demonstrates why traditional methods to engage with the occupants are not always successful and proposes a model for a more holistic approach to this issue. The paper concludes that achieving energy efficiency in buildings is not solely a technological issue and that the construction industry needs to adopt a more user-centred approach.
Resumo:
This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.
Resumo:
This article reports on a detailed empirical study of the way narrative task design influences the oral performance of second-language (L2) learners. Building on previous research findings, two dimensions of narrative design were chosen for investigation: narrative complexity and inherent narrative structure. Narrative complexity refers to the presence of simultaneous storylines; in this case, we compared single-story narratives with dual-story narratives. Inherent narrative structure refers to the order of events in a narrative; we compared narratives where this was fixed to others where the events could be reordered without loss of coherence. Additionally, we explored the influence of learning context on performance by gathering data from two comparable groups of participants: 60 learners in a foreign language context in Teheran and 40 in an L2 context in London. All participants recounted two of four narratives from cartoon pictures prompts, giving a between-subjects design for narrative complexity and a within-subjects design for inherent narrative structure. The results show clearly that for both groups, L2 performance was affected by the design of the task: Syntactic complexity was supported by narrative storyline complexity and grammatical accuracy was supported by an inherently fixed narrative structure. We reason that the task of recounting simultaneous events leads learners into attempting more hypotactic language, such as subordinate clauses that follow, for example, while, although, at the same time as, etc. We reason also that a tight narrative structure allows learners to achieve greater accuracy in the L2 (within minutes of performing less accurately on a loosely structured narrative) because the tight ordering of events releases attentional resources that would otherwise be spent on finding connections between the pictures. The learning context was shown to have no effect on either accuracy or fluency but an unexpectedly clear effect on syntactic complexity and lexical diversity. The learners in London seem to have benefited from being in the target language environment by developing not more accurate grammar but a more diverse resource of English words and syntactic choices. In a companion article (Foster & Tavakoli, 2009) we compared their performance with native-speaker baseline data and see that, in terms of nativelike selection of vocabulary and phrasing, the learners in London are closing in on native-speaker norms. The study provides empirical evidence that L2 performance is affected by task design in predictable ways. It also shows that living within the target language environment, and presumably using the L2 in a host of everyday tasks outside the classroom, confers a distinct lexical advantage, not a grammatical one.
Resumo:
Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems account for more than 60% of the energy consumption of buildings in the UK. However, the effect of the variety of HVAC&R systems on building energy performance has not yet been taken into account within the existing building energy benchmarks. In addition, the existing building energy benchmarks are not able to assist decision-makers with HVAC&R system selection. This study attempts to overcome these two deficiencies through the performance characterisation of 36 HVAC&R systems based on the simultaneous dynamic simulation of a building and a variety of HVAC&R systems using TRNSYS software. To characterise the performance of HVAC&R systems, four criteria are considered; energy consumption, CO2 emissions, thermal comfort and indoor air quality. The results of the simulations show that, all the studied systems are able to provide an acceptable level of indoor air quality and thermal comfort. However, the energy consumption and amount of CO2 emissions vary. One of the significant outcomes of this study reveals that combined heating, cooling and power systems (CCHP) have the highest energy consumption with the lowest energy related CO2 emissions among the studied HVAC&R systems.
Resumo:
It is generally accepted that the physical workplace environment affects employees’ satisfaction and, consequently, their perceived productivity and well-being. This study investigated whether employee “satisfaction” variables can predict perceived productivity, well-being and enjoyment at work, and if so, to what extent. The study also explored whether limiting employees’ control over their environment could save energy without compromising employees’ satisfaction and perceived productivity. Preoccupancy and post-occupancy evaluation studies were conducted, in terms of both energy consumption and employee perceptions, to make comparisons between a company’s old and current headquarters buildings, both located in the same area of London. The results showed that employees were more satisfied with their work environment at their new HQ, in general, than with that of their previous office. Also, employees’ self-reported productivity, well-being and enjoyment at work improved after the move. It was revealed that the combination of employees’ level of satisfaction with “interior use of space” and “physical conditions” was the best predictor of their perceived productivity, while satisfaction with “indoor facilities” was not a good predictor. In terms of energy performance, although the new HQ’s energy consumption per m2 was significantly less than that of the previous building, there was still a gap between the refurbishment design target and the actual performance of the building. The findings suggest that this gap could be due to a number of factors, including an ineffective use of interior space, and occupants’ behaviour.
Resumo:
Firms typically present a mixed picture of corporate social performance (CSP), with positive and negative indicators exhibited by the same firm. Thus, stakeholders’ judgements of corporate social responsibility (CSR) typically evaluate positives in the context of negatives, and vice versa. Building on social judgement theory, we present two alternative accounts of how stakeholders respond to such complexity, which provide differing implications for the financial effects of CSP: reciprocal dampening and rewarding uniformity. Echoing notable findings on strategic consistency, our US panel study finds that firms that exhibit uniformly positive or uniformly negative indicators in particular dimensions of CSP outperform firms that exhibit a mixed picture of positives and negatives, which supports the notion that stakeholders’ judgements of CSR reward uniformity.
Resumo:
The solar and longwave environmental irradiance geometry (SOLWEIG) model simulates spatial variations of 3-D radiation fluxes and mean radiant temperature (T mrt) as well as shadow patterns in complex urban settings. In this paper, a new vegetation scheme is included in SOLWEIG and evaluated. The new shadow casting algorithm for complex vegetation structures makes it possible to obtain continuous images of shadow patterns and sky view factors taking both buildings and vegetation into account. For the calculation of 3-D radiation fluxes and T mrt, SOLWEIG only requires a limited number of inputs, such as global shortwave radiation, air temperature, relative humidity, geographical information (latitude, longitude and elevation) and urban geometry represented by high-resolution ground and building digital elevation models (DEM). Trees and bushes are represented by separate DEMs. The model is evaluated using 5 days of integral radiation measurements at two sites within a square surrounded by low-rise buildings and vegetation in Göteborg, Sweden (57°N). There is good agreement between modelled and observed values of T mrt, with an overall correspondence of R 2 = 0.91 (p < 0.01, RMSE = 3.1 K). A small overestimation of T mrt is found at locations shadowed by vegetation. Given this good performance a number of suggestions for future development are identified for applications which include for human comfort, building design, planning and evaluation of instrument exposure.
Resumo:
The objective of this article is to review the scientific literature on airflow distribution systems and ventilation effectiveness to identify and assess the most suitable room air distribution methods for various spaces. In this study, different ventilation systems are classified according to specific requirements and assessment procedures. This study shows that eight ventilation methods have been employed in the built environment for different purposes and tasks. The investigation shows that numerous studies have been carried out on ventilation effectiveness but few studies have been done regarding other aspects of air distribution. Amongst existing types of ventilation systems, the performance of each ventilation methods varies from one case to another due to different usages of the ventilation system in a room and the different assessment indices used. This review shows that the assessment of ventilation effectiveness or efficiency should be determined according to each task of the ventilation system, such as removal of heat, removal of pollutant, supply fresh air to the breathing zone or protecting the occupant from cross infection. The analysis results form a basic framework regarding the application of airflow distribution for the benefit of designers, architects, engineers, installers and building owners.
Resumo:
This study investigates the possibility of native-like ultimate attainment by analyzing L2 knowledge of aspect as seen in the Preterit/Imperfect contrast of highly successful English L2 learners of Portuguese and Spanish. Building on innovative work by Montrul & Slabakova (2003) and Slabakova & Montrul (2003), we test knowledge of semantic entailments associated with the acquisition of [+/- perfective] features checked in higher AspP. Additionally, we investigate the possibility of a specific pattern of associated target-deviant L2 performance. We hypothesize that L2 performance can be affected by explicit positive evidence (pedagogical rules) despite otherwise demonstrable native-like competence. Indeed, the data reveal a pattern of target-deviant performance noted only in three specific contexts, all of which can be linked to traditional instruction: (a) with particular stative verbs not used in the Preterit (b) when preceded by certain adverbial phrases (e.g.,siempre) and (c) so-called semantic shifting verbs (e.g., sabía vs. supe).
Resumo:
Energy use intensity (EUI) and climate have a well documented correlation, which is generally applied in building energy management. Green buildings have sought to greatly reduce energy consumption and a number of examples are documented in the literature. A sample of high performance buildings constructed in a variety of global locations is analyzed here, and provides evidence that measures to reduce energy consumption have reduced EUI to the point where its correlation with heating degree days is no longer apparent. This result suggests that end-user behaviour is the next major hurdle in lowering the energy consumption of greener buildings.
Resumo:
Different treatments that could be implemented in the home environ-ment are evaluated with the objective of reaching a more rational and efficient use of energy. We consider that a detailed knowledge of energy-consuming behaviour is paramount for the development and implementation of new technologies, services and even policies that could result in more rational energy use. The proposed evaluation methodology is based on the development of economic experiments implemented in an experimental economics laboratory, where the behaviour of individuals when making decisions related to energy use in the domestic environment can be tested.
Resumo:
Roofs are severely hit by solar radiation in summer; hence the use of cool materials on the finishing layer provides a significant reduction in the heat flow entering the building, with sensible attenuation in the building cooling load. In this paper, a case study is presented, based on the dynamic simulation of an existing office building in Catania (southern Italy). Here, a part of the roof has been recently treated with a commercial cool paint, with the aim of improving thermal comfort in summer. Hence, the simulations represent a preliminary study that will allow assessing the expected effectiveness of the intervention. More in detail, the results of the simulations will be discussed in terms of both thermal comfort and energy savings, through the evaluation of parameters such as the roof surface temperature, the operative temperature and the cooling load for both conditions, i.e. with and without the cool paint. The paper also discusses the potential increase in the energy needs for winter heating, and looks at the overall annual balance in terms of primary energy; this is made by considering different climatic conditions and envelope characteristics. These aspects are usually not well highlighted in the current scientific literature.
Resumo:
Thermochromic windows are able to modulate their transmittance in both the visible and the near-infrared field as a function of their temperature. As a consequence, they allow to control the solar gains in summer, thus reducing the energy needs for space cooling. However, they may also yield a reduction in the daylight availability, which results in the energy consumption for indoor artificial lighting being increased. This paper investigates, by means of dynamic simulations, the application of thermochromic windows to an existing office building in terms of energy savings on an annual basis, while also focusing on the effects in terms of daylighting and thermal comfort. In particular, due attention is paid to daylight availability, described through illuminance maps and by the calculation of the daylight factor, which in several countries is subject thresholds. The study considers both a commercially available thermochromic pane and a series of theoretical thermochromic glazing. The expected performance is compared to static clear and reflective insulating glass units. The simulations are repeated in different climatic conditions, showing that the overall energy savings compared to clear glazing can range from around 5% for cold climates to around 20% in warm climates, while not compromising daylight availability. Moreover the role played by the transition temperature of the pane is examined, pointing out an optimal transition temperatures that is irrespective of the climatic conditions.