998 resultados para Beryllium 10, standard deviation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Knowledge of the uncertainty of measurement of testing results is important when results have to be compared with limits and specifications. In the measurement of sound insulation following standards UNE EN ISO 140-4 the uncertainty of the final magnitude is mainly associated to the average sound pressure levels L1 and L2 measured. A parameter that allows us to quantify the spatial variation of the sound pressure level is the standard deviation of the pressure levels measured at different points of the room. In this work, for a wide number of measurements following standards UNE EN ISO 140-4 we analyzed qualitatively the behaviour of the standard deviation for L1 and L2. The study of sound fields in enclosed spaces is very difficult. There are a wide variety of rooms with different sound fields depending on factors as volume, geometry and materials. In general, we observe that the L1 and L2 standard deviations contain peaks and dips independent on characteristics of the rooms at single frequencies that could correspond to critical frequencies of walls, floors and windows or even to temporal alterations of the sound field. Also, in most measurements according to UNE EN ISO 140-4 a large similitude between L1 and L2 standard deviation is found. We believe that such result points to a coupled system between source and receiving rooms, mainly at low frequencies the shape of the L1 and L2 standard deviations is comparable to the velocity level standard deviation on a wall

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 10Be/9Be-based chronostratigraphy has been determined for ODP 181, Site 1121 sediment core, recovered from the foot of the Campbell Plateau, Southwest Pacific Ocean. This core was drilled through the Campbell 'skin drift' in ca. 4500 m water depth on the mid-western margin of the extensive Campbell Nodule Field, beneath the flow of the major cold-water Deep Western Boundary Current (DWBC). In the absence of detailed biostratigraphy, beryllium isotopes have provided essential time information to allow palaeo-environmental interpretation to be undertaken on the upper 7 m of the core. Measured 10Be/9Be ratios of sediment, and of ferromanganese nodules entrapped in the sediment, decrease systematically with depth in the core, in accordance with radioactive decay. However, the 10Be/9Be data diverge from ca. 3 m below the seafloor (mbsf) to the top of the core, giving rise to several possible geochronological models. The preferred model assumes that the measured 10Be/9Be ratios of the nodule rims reflect initial 10Be/9Be ratios equivalent to contemporary seawater, and that these can be used to derive the true age of the sediment where the nodules occur. The nodule rim ages can be then used to interpret the sediment 10Be/9Be data, which indicate an overall age to ca. 7 mbsf of ca. 17.5 Ma. The derived chronology is consistent with diatom biostratigraphy, which indicates an age of 2.2-3.6 Ma at 1 mbsf. Calculated sedimentation rates range from 8 to 95 cm m.y.**-1, with an overall rate to 7 mbsf of ca. 39 cm m.y.**-1. The lowest rates generally coincide with the occurrence of entrapped nodules, and reflect periods of increased bottom current flow causing net sediment loss. Growth rates of individual nodules decrease towards the top of the sediment core, similar to the observed decrease in growth rate from core to rim of seafloor nodules from the Campbell Nodule Field. This may be related to an overall increase in the vigour of the DWBC from ca. 10 Ma to the present.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To prospectively assess the potential of noninvasive diffusion-weighted magnetic resonance (MR) imaging to depict changes in microperfusion and diffusion in patients with acute unilateral ureteral obstruction. MATERIALS AND METHODS: The local ethics committee approved the study protocol. Informed consent was obtained. Diffusion-weighted MR imaging was performed in 21 patients (two women, 19 men; mean age, 43 years +/- 10 [standard deviation]) with acute unilateral ureteral obstruction due to a calculus diagnosed at unenhanced computed tomography. A control group (one woman, 15 men; mean age, 44 years +/- 12) underwent the same MR protocol. Standard processing yielded an apparent diffusion coefficient (ADC) ADCT; the separation of microperfusion and diffusion contributions yielded the perfusion fraction FP and the pure diffusion coefficient ADCD. ADCT, ADCD, and FP were compared between obstructed and contralateral unobstructed kidneys and with control values. For statistical analysis, nonparametric rank tests were used. A P value of less than .05 was considered significant. RESULTS: No significant differences were observed between the ADCT of the medulla or cortex of the obstructed and unobstructed kidneys. Compared with control kidneys, only medullary ADCT was slightly increased in the obstructed kidney (P < .04). However, the ADCD in the medulla of the obstructed and unobstructed kidneys was significantly higher than that in control subjects (201 x 10(-5) mm2/sec +/- 16 and 199 x 10(-5) mm2/sec +/- 20 vs 189 x 10(-5) mm2/sec +/- 12; P < .008 and P < .03, respectively). FP of the cortex of the obstructed kidney was significantly lower than that in the unobstructed kidney (20.2% +/- 4.8 vs 24.0% +/- 5.8; P < .002); FP of the medulla was slightly lower in the obstructed kidney than in the unobstructed kidney (18.3% +/- 5.9 vs 20.7% +/- 6.4; P = .05). CONCLUSION: Diffusion-weighted MR imaging allows noninvasive detection of changes in renal perfusion and diffusion during acute unilateral ureteral obstruction, as exemplified in patients with a ureteral calculus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first series of Soviet standard reference samples of composition of ore materials and ocean pelagic sediments has been created. It includes iron-manganese nodules (SDO-4, SDO-5 and SDO-6), ore crusts (SDO-7) diatomaceous ooze (SDO-8), and deep-sea red clays (SDO-9). The standards are intended to serve as a metrologic basis for physical, physicochemical and chemical analyses of iron-manganese minerals and ocean sediments. The standards are provided with certified analyses of rock-forming components and certain trace elements. Certified characteristics are based on statistical analysis of data obtained from an inter-laboratory experiment involving analysis of the standard reference samples by a variety of methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reliability of paleomagnetic records as proxies of the geomagnetic field intensity is still a matter of controversy since volcanic materials hardly provide continuous records, and marine sediments are suspected to carry a remanence biased by post-depositional realignments and/or by overprints. Such long standing debate emphasizes the need for the development of methods independent from paleomagnetism to decipher geomagnetic intensity variations. High resolution measurements of authigenic 10Be/9Be along with a detailed sedimentary record of directional and relative paleointensity variations evidence, over the 0.6-1.3 Ma time interval, frequent and recurrent excursions or short events in the late Matuyama and the early Brunhes epochs, among which two Brunhes-Matuyama reversal precursors and an intra-Jaramillo excursion. The results of this study confirm the idea of a highly unstable geomagnetic field as suggested by paleomagnetic evidences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PremessaSebbene numerosi studi prospettici, controllati e randomizzati abbiano dimostrato il successo della ventilazione non-invasiva a pressione positiva (NIV) in casi selezionati di insufficienza respiratoria acuta ipercapnica (IRA) in setting con intensità di cura differenti, i dati di pratica clinica relativi all’uso della NIV nel “mondo reale” sono limitati. Scopo Riportare i risultati della nostra esperienza clinica sulla NIV nell’IRA applicata nell’Unità di Terapia Semi-Intensiva Respiratoria (UTSIR) allocata all’interno dell’Unità Operativa di Pneumologia di Arezzo negli anni 1996-2006 in termini di: tollerabilità, effetti sui gas ematici, tasso di successo e fattori predittivi del fallimento.MetodiTrecentocinquanta dei 1484 pazienti (23.6%) consecutivamente ammessi per IRA nella nostra Unità Operativa di Pneumologia durante il periodo di studio hanno ricevuto la NIV in aggiunta alla terapia standard, in seguito al raggiungimento di criteri predefiniti impiegati di routine.RisultatiOtto pazienti (2.3%) non hanno tollerato la NIV per discomfort alla maschera, mentre i rimanenti 342 (M: 240, F: 102; età: mediana (interquartili) 74.0 (68.0-79.3) anni; BPCO: 69.3%) sono stati ventilati per >1 ora. I gas ematici sono significativamente migliorati dopo 2 ore di NIV (media (deviazione standard) pH: 7.33 (0.07) versus 7.28 (7.25-7.31), p<0.0001; PaCO2: 71.4 (15.3) mmHg versus 80.8 (16.6) mmHg, p<0.0001; PaO2/FiO2: 205 (61) versus 183 (150-222), p<0.0001). La NIV ha evitato l’intubazione in 285/342 pazienti (83.3%) con una mortalità ospedaliera del 14.0%. Il fallimento della NIV è risultato essere predetto in modo indipendente dall’Apache III (Acute Physiology and Chronic Health Evaluation III) score, dall’indice di massa corporea e dal fallimento tardivo della NIV (> 48 ore di ventilazione) dopo iniziale risposta positiva.ConclusioniSecondo la nostra esperienza clinica di dieci anni realizzata in una UTSIR, la NIV si conferma essere ben tollerata, efficace nel migliorare i gas ematici e utile nell’evitare l’intubazione in molti episodi di IRA non-responsivi alla terapia standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)(2). The correlation coefficient of the graph plotted from the non-nalized absorbance signals of Bi versus Pb was r=0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve, and analytical curves obtained from Pb additions in red and white wine vinegar obtained from reference solutions prepared in 0.2% (v/v) HNO3, samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analvtical curves without. Analytical curves in the 2.5-15 pg L-1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analvte concentration, and typical linear correlations of r=0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 pg L-1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 mu g L-1 and the relative standard deviation was <= 3.8% and <= 8.3% (n = 12) for a sample containing, 10 mu L-1 Pb with and without internal standard, respectively. (C) 2007 Elsevier B.V. All rights reserved.