891 resultados para Bernard, of Clairvaux, Saint, 1090 or 1091-1153.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Euro-Collins solution was developed for the preservation of organs for transplantation, whose characteristics have raised interest for its use as a storage medium for avulsed teeth before replantation. This study evaluated histologically and morphometrically the healing process of dog teeth replanted after storage in Euro-Collins solution or bovine milk.Materials and Methods: Eighty roots of 4 young adult mongrel clogs were randomly assigned to 4 groups (n = 20) and the root canals were instrumented and obturated with gutta-percha and a calcium hydroxide-based sealer. After 2 weeks, the teeth were extracted and subjected to the following protocols: GI (negative control), replantation immediately after extraction; GII (positive control), bench-drying for 2 hours before replantation; GIII and GIV, immersion in 10 mL of whole bovine milk and Euro-Collins solution at 4 C, respectively, for 8 hours before replantation. The animals were sacrificed 90 days postoperatively. The pieces containing the replanted teeth were subjected to routine processing for histologic and histometric analyses under light microscopy and polarized light microscopy.Results: Root resorption was observed in all groups. GII exhibited the greatest loss of dental structure (P < .01), and inflammatory resorption was predominant in this group. Storage in milk showed poorer results than immediate replantation and storage in Euro-Collins solution (P < .01). The teeth stored in Euro-Collins solution presented similar extension of root resorption and periodontal ligament reorganization to those of immediately replanted teeth.Conclusions: The findings of this study suggest that the Euro-Collins solution is an adequate storage medium for keeping avulsed teeth for up to 8 hours before replantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to histologically analyze the influence of bioactive glass and/or acellular dermal matrix on bone healing in surgically created defects in the tibiae of 64 rats (Rattus norvegicus, albinus, Wistar). Materials and Methods: A 4-mm X 3-mm unicortical defect was created on the anterolateral surface of the tibia. Animals were divided into 4 groups: C, control; BG, the defect was filled with bioactive glass; ADM, the defect was covered with acellular dermal matrix; and BG/ADM, the defect was filled with bioactive glass and covered with acellular dermal matrix. Animals were sacrificed at 10 or 30 days postoperatively, and the specimens were removed for histologic processing. The formation of new bone in the cortical area of the defect was evaluated histomorphometrically. Results: At 10 and 30 days postoperatively, groups C (39.65% +/- 5.63% / 63.34% +/- 5.22%) and ADM (38.12% +/- 5.53 / 58.96% +/- 7.05%) presented a larger amount of bone formation compared to the other groups (P<.05). In the same periods, groups BG (13.10% +/- 6.29% / 29.5% +/- 5.56%) and BG/ADM (20.72% +/- 8.31% / 24.19% +/- 6.69%) exhibited statistically similar new bone formation. However, unlike the other groups, group BG/ADM did not present a significant increase in bone formation between the 2 time points. Conclusion: Based on these results, it can be concluded that all of the materials used in this study delayed bone healing in non-critical-size defects. INT J ORAL MAXILLOFAC IMPLANTS 2008;23:811-817

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as alterações morfológicas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados, sob ventilação com tubo traqueal (TT) ou máscara laríngea (ML). MÉTODOS: Doze cães adultos foram divididos aleatoriamente em dois grupos: grupo TT (n-6) e grupo ML (n-6), submetidos à anestesia venosa e ventilação mecânica, em sistema sem reabsorção de CO2. Foram registrados parâmetros hemodinâmicos e ventilatórios, temperatura timpânica, temperatura, umidade relativa e absoluta do ar ambiente e dos gases inalados durante 3 horas. Ao término do experimento, os animais foram submetidos a eutanásia e realizadas biópsias ao longo do segmento traqueal para estudo morfológico. Três cães saudáveis foram utilizados para controle morfológico. RESULTADOS: A temperatura dos gases inalados manteve-se entre 24ºC e 26ºC, a umidade relativa entre 10% e 12%, e umidade absoluta entre 2 -3 mg H2O.L-1 sem diferença significativa entre os grupos. em ambos os grupos a análise histológica evidenciou processo inflamatório epitelial e congestão no córion, e a microscopia eletrônica de varredura mostrou agrupamento e desorganização ciliar. A microscopia eletrônica de transmissão detectou maiores alterações no grupo TT do que no ML, como alargamento das junções intercelulares, desorientação ciliar, vacuolização citoplasmática, alterações nucleares como pcinose e condensação da cromatina. CONCLUSÃO: A máscara laríngea determinou alterações menos pronunciadas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experiments were conducted to study effects of macromolecules on stallion sperm capacitation and fertilization as determined by penetration of bovine zona-free and equine partially zona-removed oocytes. Stallion sperm were capacitated in TYH medium (modified Krebs-Ringer bicarbonate) supplemented with either 1 mg/mL of polyvinylalcohol (PVA) or 4 mg/ mL of BSA. Capacitation was induced with 8 bromoadenosine cyclic monophosphate (8BrcAMP; 0.5 mM) alone or in combination with 0.1 μM of ionomycin. Intraspecies gametes were co-incubated in TYH/PVA or TYH/ BSA for 18 to 20 h. For zona-free bovine oocytes, penetration rate (35%) with the combination of 8BrcAMP and ionomycin in PVA-containing medium was higher (P < 0.05) than any treatment in BSA-containing medium (5 to 6%). A similar study was conducted using equine oocytes with partially removed zonae. Sperm capacitated and used for in vitro fertilization (IVF) in PVA-containing medium had higher penetration rates (P < 0.01) than sperm in BSA-containing medium (54 vs. 11%). The effect of equine preovulatory follicular fluid on bovine oocyte penetration was assessed. Bovine oocytes were matured in tissue culture medium-199 with 0, 20, 50, or 100% equine preovulatory follicular fluid, and 1 IU/mL of equine chorionic gonadotropin. Stallion sperm were treated with 8BrcAMP + ionomycin in PVA- or BSA-containing media. The penetration rates of bovine zona-free oocytes by stallion sperm were again higher with PVA (47%) than BSA (18%; P < 0.01). Penetration rates of oocytes matured in 100% follicular fluid were higher (P < 0.05) than for oocytes matured with 0% follicular fluid. The effects of equine follicular fluid and PVA/BSA during sperm capacitation on standard bovine IVF were examined. Culture of bovine oocytes with equine follicular fluid did not affect oocyte maturation or penetration rates after IVF. Bovine sperm capacitated with heparin in PVA-containing medium yielded lower (P < 0.05) fertilization rates than those capacitated in BSA-containing medium when incubated with both zona-intact and zona-free bovine oocytes. In summary, PVA was superior to BSA for ionophore-induced capacitation of equine sperm for penetration of zona-free bovine oocytes or partially zona-removed equine oocytes, but not for standard bovine IVF with bovine sperm. Zona-free bovine oocytes may be useful for assaying in vitro capacitation and fertilization of stallion sperm. © 2003 American Society of Animal Science. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of our investigation is to compare the intrapulpal temperature changes following blue LED system and halogen lamp irradiation at the enamel surface of permanent teeth. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Several light sources can be used: halogens, arc plasma, lasers, and recently blue LED systems. An important aspect to be observed during such a procedures is the temperature change. In this study, we have used nine human extracted permanent teeth: three central incisors, three lateral incisors, and three canines. Teeth were exposed to two light sources: blue LED system (preliminary commercial model LEC 470-II) and halogen lamp (conventional photo-cure equipment). The surface of teeth was exposed for 20, 40, and 60 sec at the buccal and lingual enamel surface with an angle of 45 degrees. Temperature values measured by a thermistor placed at pulpar chamber were read in time intervals of 1 sec. We obtained plots showing the temperature evolution as a function of time for each experiment. There is a correlation between heating quantity and exposition time of light source: with increasing exposition time, heating increases into the pulpal chamber. The halogen lamp showed higher heating than the LED system, which showed a shorter time of cooling than halogen lamp. The blue LED system seems like the indicated light source for photo-cure of composite resin during the bonding of brackets. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Blue LED equipment did not heat during its use. This could permit a shorter clinical time of operation and better performance. © Mary Ann Liebert, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods: Metallic frameworks (25 mm × 3 mm × 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 μm aluminum oxide at the central area of the frameworks (8 mm × 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: 1 mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 °C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 °C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 °C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey's test (α = 0.05). Results: The mean flexural strength values for the ceramic-gold alloy combination (55 ± 7.2 MPa) were significantly higher than those of the ceramic-Ti cp combination (32 ± 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 ± 6.6 and 53 ± 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 ± 6.8 and 29 ± 6.8 MPa, respectively) compared to the control group (58 ± 7.8 and 39 ± 5.1 MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey's test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance: Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. © 2007 Academy of Dental Materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the greatest challenges faced by buccomaxillofacial prosthetists is to reproduce the patient's exact skin color and provide adequate esthetics. To reach this objective, professionals must use materials with easy characterization and that maintain color over long periods of time. The objective of this study was, thus, to evaluate the color stability of two types of silicones, Silastic 732 and Silastic MDX4-4210. Twenty-four test specimens were made from each type of silicone and were divided into a colorless group and groups intrinsically pigmented with ceramics, cosmetics or iron oxide. The specimens were submitted to an accelerated system of aging for non-metallic materials. Readings were carried out initially and after periods corresponding to 163, 351, 692 and 1,000 hours of aging, using a reflection spectrophotometer analysis, and color alterations were calculated by the CIE L*a*b* system. The data were submitted to variance analysis and Tukey's test at a 5% level of probability. The results demonstrated that, irrespective of the period of time analyzed, all the materials underwent some type of chromatic alteration (ΔE > 0). The test specimens made with Silastic 732 and MDX4-4210, without pigmentation, presented the lowest color alteration values after 1,000 hours of aging. Of the pigments, ceramic presented the lowest color alteration values and cosmetic powder presented the highest values. Thus, it may be concluded that the materials without the incorporation of pigments presented similar color alteration values, and did not differ statistically. The cosmetic powder used in this study was the pigment that most altered the color of the test specimens. © 2009 Sociedade Brasileira de Pesquisa Odontológica.