227 resultados para BOMBAS CENTRÍFUGAS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermoelectric Refrigerators (TEC Thermoelectric Cooling) are solid-state heat pumps used in applications where stabilization of temperature cycles or cooling below the room temperature are required. TEC are based on thermoelectric devices, and these in turn, are based on the Peltier effect, which is the production of a difference in temperature when an electric current is applied to a junction formed by two non-similar materials. This is one of the three thermoelectric effects and is a typical semiconductor junction phenomenon. The thermoelectric efficiency, known as Z thermoelectric or merit figure is a parameter that measures the quality of a thermoelectric device. It depends directly on electrical conductivity and inversely on the thermal conductivity. Therefore, good thermoelectric devices have typically high values of electrical conductivity and low values of thermal conductivity. One of the most common materials in the composition of thermoelectric devices is the semiconductor bismuth telluride (Bi2Te3) and its alloys. Peltier plates made up by crystals of semiconductor P-type and N-type are commercially available for various applications in thermoelectric systems. In this work, we characterize the electrical properties of bismuth telluride through conductivity/resistivity of the material, and X-rays power diffraction and magnetoresistance measurements. The results were compared with values taken from specific literature. Moreover, two techniques of material preparation, and applications in refrigerators, are discussed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is nowadays a growing demand for located cooling and stabilization in optical and electronic devices, haul of portable systems of cooling that they allow a larger independence in several activities. The modules of thermoelectrical cooling are bombs of heat that use efect Peltier, that consists of the production of a temperature gradient when an electric current is applied to a thermoelectrical pair formed by two diferent drivers. That efect is part of a class of thermoelectrical efcts that it is typical of junctions among electric drivers. The modules are manufactured with semiconductors. The used is the bismuth telluride Bi2Te3, arranged in a periodic sequence. In this sense the idea appeared of doing an analysis of a system that obeys the sequence of Fibonacci. The sequence of Fibonacci has connections with the golden proportion, could be found in the reproductive study of the bees, in the behavior of the light and of the atoms, as well as in the growth of plants and in the study of galaxies, among many other applications. An apparatus unidimensional was set up with the objective of investigating the thermal behavior of a module that obeys it a rule of growth of the type Fibonacci. The results demonstrate that the modules that possess periodic arrangement are more eficient

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oral and facial bone defects can undertake appearance, psychosocial well-being and stomathognatic function of its patients. Over the yerars several strategies for bone defect regeneration have arised to treat these pathologies, among them the use of frozen and irradiated bone allograft. Manipulation of bone grafts it s not determined yet, and several osteotomy alternatives can be observed. The present work evaluated with a microscope the bone fragments obtained from different osteotomy methods and irrigation on rings and blocks allografts irradiated and frozen at 80° negative in a rabbit model. The study is experimental in vitro and it sample was an adult male New Zealand rabbit. The animal was sacrificed to obtain long bones, that were submitted to freezing at 80º negative and irradiated with Cobalt- 60. Then the long bones were sectioned into 24 bone pieces, divided into 4 groups: G1 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thickness with high-speed handpiece with manual irrigation; G2 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thick with surgical motor with a manual irrigation rotation 1500 rpm; GA (n=06), osteotomy with trephine using manual irrigation with saline; and GB (n=06), osteotomy with trephine using saline from peristaltic pumps of surgical motor. Five bone pieces of each group were prepared for analysis on light microscopy (LM) and one on electronic scan electronic microscopy (SEM). On the SEM analysis edges surface, presence of microcracks and Smear Layer were evaluated. Analyzing osteotomy technics on SEM was observed: increased presence of microcracks cutting with high speed; increased presence of areas covered by Smear Layer when cutting with motor implant. The irrigation analysis with SEM was observed: that the presence of microcracks does not depend on the type of irrigation; on manual irrigation, there was greater discrepancy between the cutting lines. The descriptive analysis of the osteotomy and irrigation process on LM showed: histological analysis showing the bony margins with clear tissue changed layer, composed of blackened tissue of charred appearance near to the cortical bone; on the edges of the bony part, bone fragments that were displaced during the bone cut and bone irregularities were observed. After analysis of results we can conclude: that there was greater regularity of the bone cut using high-speed handpiece than using motor implant; the cut with trephine using saline irrigated from peristaltic pumps of surgical motor showed greater homogeneity when compared with manual irrigation; charred tissue was found in all obtained bone samples, whit no significant statistically difference on the proportion of carbonization of the two analysed technics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: O número de artroplastia total de quadril (ATQ) bilateral tem aumentado a cada ano. Analgesia pós-operatória pela infusão contínua perineural com anestésico local tem se mostrado favorável quando comparada com analgesia sistêmica. O uso de bombas elastoméricas tem aumentado a satisfação do paciente quando em comparação com os modelos eletrônicos. O objetivo deste relato foi descrever um caso de analgesia contínua bilateral do plexo lombar via posterior, com infusão contínua através de bomba elastomérica, em paciente submetido à uma artroplastia bilateral de quadril. RELATO do CASO: Paciente feminina, 46 anos, 65 kg, 162 cm, com artrite reumatoide e hipertensão arterial, estado físico ASA II, escalada para ser submetida a ATQ bilateral em um único estágio. Uso de corticosteroide por 13 anos. Hemoglobina = 10,1 g.dL-1, hematócrito = 32,7%. Monitoração de rotina. Raquianestesia com 15 mg de bupivacaína 0,5% isobárica. Anestesia geral com propofol (PFS) e remifentanil e intubação sem bloqueadores neuromusculares. ATQ direita e no final, bloqueio plexo lombar com estimulador e conjunto agulha 150 mm e injeção de 20 mL bupivacaína 0,2% e passagem de cateter. ATQ esquerda e, no final, mesmo procedimento. Estudado dispersão do anestésico e contraste. Instalado bomba elastomérica com bupivacaína 0,1% (400 mL) em velocidade de 14 mL.h-1. Transferida para Unidade de Cuidados Intensivos (UCI). Vinte e quatro horas após, nova bomba com a mesma solução. Nenhum bolus durante 50 horas. Após remoção de cateter, dor controlada por via oral com cetoprofeno e dipirona. CONCLUSÕES: O bloqueio bilateral contínuo periférico com infusão de bupivacaína a 0,1% com bombas elastoméricas é um procedimento seguro e efetivo em adultos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo foi a padronização de modelo experimental de coração isolado parabiótico em coelhos, testando sua estabilidade e durabilidade, para fins de pesquisa cardiovascular. Foram utilizados 66 coelhos raça Norfolk-2000 divididos em grupo doador do coração isolado e animais suporte, totalizando 33 preparações. Mediante auxilio de bombas peristálticas estabeleceu-se suporte circulatório para o coração isolado mantendo-se fluxo constante(16ml/min.). Um balão intraventricular foi inserido no ventrículo esquerdo, sendo ajustado para gerar pressão diastólica de ± 10mmHg. A freqüência foi fixada em 120 batimentos por minuto mediante o uso de marcapasso. Foram avaliadas variáveis hemodinâmicas, laboratoriais e anatomopatológicas. Das 33 preparações, 13 foram excluídas mediante critérios pré-estabelecidos. Das 20 restantes, 10 cumpriram o tempo máximo do protocolo(180 minutos). Com relação ao animal suporte houve deterioração hemodinâmica progressiva c/ queda da pressão arterial média(89,30±6,09mmHg->47,50±6,35mmHg). Com relação ao corações isolado, das 10 preparações que cumpriram os 180 minutos de protocolo, houve estabilidade hemodinâmica. As variáveis laboratoriais mostraram queda progressiva do sódio, potássio e hemoglobina, sendo compatível com hemodiluição. O exame anatomopatológico mostrou espaçamento maior entre fibras, compatível com edema. O presente modelo mostrou estabilidade e atividade de 100% das preparações em 60 minutos, havendo perdas progressivas chegando a 50% das preparações em atividade em 180 minutos. O presente modelo, dentro das limitações estabelecidas é viável para pesquisas cardiovasculares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia e Ciência de Alimentos - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)