998 resultados para BIO-OSS(R)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the transmission-line modeling (TLM) applied to bio-thermal problems was improved by incorporating several novel computational techniques, which include application of graded meshes which resulted in 9 times faster in computational time and uses only a fraction (16%) of the computational resources used by regular meshes in analyzing heat flow through heterogeneous media. Graded meshes, unlike regular meshes, allow heat sources to be modeled in all segments of the mesh. A new boundary condition that considers thermal properties and thus resulting in a more realistic modeling of complex problems is introduced. Also, a new way of calculating an error parameter is introduced. The calculated temperatures between nodes were compared against the results obtained from the literature and agreed within less than 1% difference. It is reasonable, therefore, to conclude that the improved TLM model described herein has great potential in heat transfer of biological systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The variation in the proportion of reproductive branches, fruit, and seed production of Ipomoea pes-caprae (L.) R. Br. (Convolvulaceae) were evaluated at ten beaches on Santa Catarina Island, state of Santa Catarina, Brazil. Three patches per beach of Ipomoea pes-caprae were monitored, involving two reproductive cycles. Ipomoea pes-caprae presented initially an average length of patches of 14 m, with 9.6 branches/m² and 39% of reproductive branches. The proportion of reproductive branches varied between the cycles, but there was not noticed an alternation of reproductive effort between the subsequent cycles. There was a reduction in the percentage of reproductive branches at six localities. In four beaches where Ipomoea pes-caprae populations declined, occurred reduction in the reproductive vigor, and in the seed production, being these declines associated to strong sea erosion. In another hand, in one beach with population increase, there were little reproductive branches due to the occurrence of young stolons. Four patches never maturated fruits, being three of these located at small beaches. The fruit and seed productions in the patches showed values up to 40 fruits/m² and up to 140 seeds/m², respectively. Populations with great seed production were localized in areas adjacent to great coastal plains, which may represent potential seed sources for areas with small seed production in the island.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uma análise da distribuição geográfica de Schefflera no Brasil extra-amazônico foi realizada com base em mapas atualizados plotando as ocorrências conhecidas das 26 espécies do gênero encontradas nessa grande área: S. angustissima (Marchal) Frodin, S. aurata Fiaschi, S. botumirimensis Fiaschi & Pirani, S. burchellii (Seem.) Frodin & Fiaschi, S. calva (Cham.) Frodin & Fiaschi, S. capixaba Fiaschi, S. cephalantha (Harms) Frodin, S. cordata (Taub.) Frodin & Fiaschi, S. distractiflora (Harms) Frodin, S. fruticosa Fiaschi & Pirani, S. gardneri (Seem.) Frodin & Fiaschi, S. glaziovii (Taub.) Frodin & Fiaschi, S. grandigemma Fiaschi, S. kollmannii Fiaschi, S. longipetiolata (Pohl ex DC.) Frodin & Fiaschi, S. lucumoides (Decne. & Planch. ex Marchal) Frodin & Fiaschi, S. macrocarpa (Cham. & Schltdl.) Frodin, S. malmei (Harms) Frodin, S. morototoni (Aubl.) Maguire, Steyermark & Frodin, S. racemifera Fiaschi & Frodin, S. ruschiana Fiaschi & Pirani, S. selloi (Marchal) Frodin & Fiaschi, S. succinea Frodin & Fiaschi, S. villosissima Fiaschi & Pirani, S. vinosa (Cham. & Schltdl.) Frodin & Fiaschi e S. aff. varisiana Frodin. Dois centros de endemismo associados com áreas de altitude elevada foram reconhecidos: Cadeia do Espinhaço em Minas Gerais e florestas montanas do Estado do Espírito Santo. Os padrões de distribuição geográfica ilustrados são discutidos com base em dados obtidos para outros grupos de angiospermas e em estudos fitogeográficos das principais fitocórias do Brasil extra-amazônico. São apresentadas também hipóteses acerca de prováveis relações filogenéticas entre alguns táxons, visando à busca de possíveis correlações entre estas e a biogeografia do grupo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os síntipos de Corydoras meridionalis Rodolpho von Ihering, 1911, tidos como desaparecidos da coleção de peixes do Museu de Zoologia da USP, foram encontrados; os exemplares tinham sido identificados como C. ehrhardti Steindachner, 1910, espécie atualmente considerada sinônimo sênior da primeira. O exame desses sintipos permite confirmar a sinonímia proposta. Dados sobre os síntipos são apresentados e comparados com os dados das descrições originais de C. ehrhardti e C. meridionalis, sendo comentadas as poucas diferenças encontradas entre eles. É designado o lectótipo de C. meridionalis e uma fotografia deste é apresentada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical trials using dendritic cells (DCs) to treat cancer patients have generated promising results in recent years. However, even simple aspects of this therapy are still not well understood, including the storage and distribution of manufactured vaccines. These processes are essential and must be elucidated in order to reduce costs. We evaluated the effects of different storage conditions on vaccine functionality using mixed lymphocyte reaction (MLR). Vaccine storage at 4 degrees C for up to 72 h had no significant effect on vaccine activity. Shipping to distant places is possible, if vaccines are kept at 4 degrees C and used up to 3 days after manufacture date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of Triesence (R) (TRI), a new preservative-free triamcinolone approved by the U. S. Food and Drug Administration (FDA) for intraocular use, on human retina pigment epithelial (ARPE-19) and rat neurosensory (R28) cells in culture. Methods: ARPE-19 and R28 cell cultures were treated 24 h with 1,000, 500, 200, or 100 mu g/mL of crystalline (cTRI) or 1,000, 500, or 200 mu g/mL of solubilized (sTRI). TRI was solubilized by centrifuging the drug, discarding the supernatant containing the vehicle and then resuspending the drug pellet in an equivalent amount of Dimethyl sulfoxide to achieve the same concentration as the commercial preparation. Percentage of cell viability (CV) was evaluated by a trypan blue dye-exclusion assay. The mitochondrial membrane potential (Delta Psi m) was analyzed with the JC-1 assay. The caspase-3/7 activity was measured by a fluorochrome assay. Results: In the ARPE-19 cultures, the cTRI caused a decrease in CV at 1,000 mg/mL (13.03 +/- 6.51; P < 0.001), 500 mu g/mL (28.87 +/- 9.3; P < 0.001), 200 mu g/mL (54.93 +/- 5.61; P < 0.001), and 100 mu g/mL (82.53 +/- 0.65; P < 0.005) compared with the untreated controls (96.98 +/- 0.16). In R28 cultures, the cTRI treatment also reduced CV values significantly (P < 0.001) for the 1,000 mu g/mL (22.73 +/- 2.44), 500 mu g/mL (34.63 +/- 1.91), 200 mu g/mL (58.70 +/- 1.39), and 100 mu g/m (75.33 +/- 2.47) compared with the untreated controls (86.08 +/- 3.54). Once the TRI was solubilized (sTRI), the CV and Delta Psi m remained similar to the untreated controls for both ARPE-19 and R28 cells. The sTRI treatment with 1,000, 500, and 200 mu g/mL increased in caspase-3/7 activity in ARPE-19 cells (P < 0.01) and in R28 cells (P < 0.05) compared with dimethyl sulfoxide equivalent controls. Conclusion: The crystalline form of TRI (cTRI) can cause a significant decrease in CV to cultured retinal cells. Once the TRI is solubilized (sTRI), at the same concentrations, the cells remain viable with no decrease in CV or Delta Psi m. The sTRI can, however, increase caspase-3/7 activity, thus suggesting some degree of apoptosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Surgical staple line dehiscence usually leads to severe complications. Several techniques and materials have been used to reinforce this stapling and thus reduce the related complications. The objective was to compare safety of two types of anastomotic reinforcement in open gastric bypass. Methods: A prospective, randomized study comparing an extraluminal suture, fibrin glue, and a nonpermanent buttressing material, Seamguard (R), for staple line reinforcement. Fibrin glue was excluded from the study and analysis after two leaks, requiring surgical reintervention, antibiotic therapy, and prolonged patient hospitalization. Results: Twenty patients were assigned to the suture and Seamguard reinforcement groups. The groups were similar in terms of preoperative characteristics. No staple line dehiscence occurred in the two groups, whereas two cases of dehiscence occurred in the fibrin glue group. No mortality occurred and surgical time was statistically similar for both techniques. Seamguard made the surgery more expensive. Conclusion: In our service, staple line reinforcement in open bariatric surgery with oversewing or Seamguard was considered to be safe. Seamguard application was considered to be easier than oversewing, but more expensive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacy of photodynamic therapy (PDT) depends on a variety of parameters: concentration of the photosensitizer at the time of treatment, light wavelength, fluence, fluence rate, availability of oxygen within the illuminated volume, and light distribution in the tissue. Dosimetry in PDT requires the congregation of adequate amounts of light, drug, and tissue oxygen. The adequate dosimetry should be able to predict the extension of the tissue damage. Photosensitizer photobleaching rate depends on the availability of molecular oxygen in the tissue. Based on photosensitizers photobleaching models, high photobleaching has to be associated with high production of singlet oxygen and therefore with higher photodynamic action, resulting in a greater depth of necrosis. The purpose of this work is to show a possible correlation between depth of necrosis and the in vivo photosensitizer (in this case, Photogem (R)) photodegradation during PDT. Such correlation allows possibilities for the development of a real time evaluation of the photodynamic action during PDT application. Experiments were performed in a range of fluence (0-450 J/cm(2)) at a constant fluence rate of 250 mW/cm(2) and applying different illumination times (0-1800 s) to achieve the desired fluence. A quantity was defined (psi) as the product of fluorescence ratio (related to the photosensitizer degradation at the surface) and the observed depth of necrosis. The correlation between depth of necrosis and surface fluorescence signal is expressed in psi and could allow, in principle, a noninvasive monitoring of PDT effects during treatment. High degree of correlation is observed and a simple mathematical model to justify the results is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In areas with limited structure in place for microscopy diagnosis, rapid diagnostic tests (RDT) have been demonstrated to be effective. Method: The cost-effectiveness of the Optimal (R) and thick smear microscopy was estimated and compared. Data were collected on remote areas of 12 municipalities in the Brazilian Amazon. Data sources included the National Malaria Control Programme of the Ministry of Health, the National Healthcare System reimbursement table, hospitalization records, primary data collected from the municipalities, and scientific literature. The perspective was that of the Brazilian public health system, the analytical horizon was from the start of fever until the diagnostic results provided to patient and the temporal reference was that of year 2006. The results were expressed in costs per adequately diagnosed cases in 2006 U. S. dollars. Sensitivity analysis was performed considering key model parameters. Results: In the case base scenario, considering 92% and 95% sensitivity for thick smear microscopy to Plasmodium falciparum and Plasmodium vivax, respectively, and 100% specificity for both species, thick smear microscopy is more costly and more effective, with an incremental cost estimated at US$ 549.9 per adequately diagnosed case. In sensitivity analysis, when sensitivity and specificity of microscopy for P. vivax were 0.90 and 0.98, respectively, and when its sensitivity for P. falciparum was 0.83, the RDT was more cost-effective than microscopy. Conclusion: Microscopy is more cost-effective than OptiMal (R) in these remote areas if high accuracy of microscopy is maintained in the field. Decision regarding use of rapid tests for diagnosis of malaria in these areas depends on current microscopy accuracy in the field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate a neutrino mass model in which the neutrino data is accounted for by bilinear R-parity violating supersymmetry with anomaly mediated supersymmetry breaking. We focus on the CERN Large Hadron Collider (LHC) phenomenology, studying the reach of generic supersymmetry search channels with leptons, missing energy and jets. A special feature of this model is the existence of long-lived neutralinos and charginos which decay inside the detector leading to detached vertices. We demonstrate that the largest reach is obtained in the displaced vertices channel and that practically all of the reasonable parameter space will be covered with an integrated luminosity of 10 fb(-1). We also compare the displaced vertex reaches of the LHC and Tevatron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic AFM probes known as MAClevers (R) were employed for sensing picogram amounts of magnetic nanoparticles, based on the cantilever frequency shifts resulting from the magnetically induced adsorption of mass. By using organothiol functionalized magnetic nanoparticles, this analytical strategy was successfully extended to the detection of gold nanoparticles, as confirmed by confocal Raman microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid-core waveguides (LCWs), devices that constrain the emitted radiation minimizing losses during the transport, are an alternative to maximize the amount of detected radiation in luminescence. In this work, the performance of a LCW flow-cell was critically evaluated for chemiluminescence measurements, by using as model the oxidation of luminol by hydrogen peroxide or hypochlorite. An analytical procedure for hypochlorite determination was also developed, with linear response in the range 0.2-3.8 mg/L (2.7-51 mu mol/L), a detection limit estimated as 8 mu g/L (0.64 mu mol/L) at the 99.7% confidence level and luminol consumption of 50 mu g/determination. The coefficients of variation were 3.3% and 1.6% for 0.4 and 1.9 mg/L CIO(-), respectively, with a sampling rate of 164 determinations/h. The procedure was applied to the analysis of Dakin`s solution samples, yielding results in agreement with those obtained by iodometric titration at the 95% confidence level. Copyright (c) 2008 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multi-pumping flow system exploiting prior assay is proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods are implemented in the same manifold that provides facilities for: in-line sample clean-up with a Bio-Rex 70 mini-column with fluidized beads: addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation; analyte precipitation with Ba(2+) or Ag(+); real-time decision on the need for next assay. The sample is initially run for chloride determination, and the analytical signal is compared with a preset value. If higher, the sample is run again, now for sulphate determination. The strategy may lead to all increased sample throughput. The proposed system is computer-controlled and presents enhanced figures of merit. About 10 samples are run per hour (about 60 measurements) and results are reproducible and Unaffected by the presence of potential interfering ions at concentration levels usually found in natural waters. Accuracy was assessed against ion chromatography. (C) 2008 Elsevier B.V. All rights reserved.