171 resultados para Astigmatism


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the accuracy of three wavefront analyzers versus a validated binocular open-view autorefractor in determining refractive error in non-cycloplegic eyes. METHODS: Eighty eyes were examined using the SRW-5000 open-view infrared autorefractor and, in randomized sequence, three wavefront analyzers: 1) OPD-Scan (NIDEK, Gamagori, Japan), 2) WASCA (Zeiss/Meditec, Jena, Germany), and 3) Allegretto (WaveLight Laser Technologies AG, Erlangen, Germany). Subjects were healthy adults (19 men and 21 women; mean age: 20.8 +/- 2.5 years). Refractive errors ranged from +1.5 to -9.75 diopters (D) (mean: +1.83 +/- 2.74 D) with up to 1.75 D cylinder (mean: 0.58 +/- 0.53 D). Three readings were collected per instrument by one examiner without anticholinergic agents. Refraction values were decomposed into vector components for analysis, resulting in mean spherical equivalent refraction (M) and J0 and J45 being vectors of cylindrical power at 0 degrees and 45 degrees, respectively. RESULTS: Positive correlation was observed between wavefront analyzers and the SRW-5000 for spherical equivalent refraction (OPD-Scan, r=0.959, P<.001; WASCA, r=0.981, P<.001; Allegretto, r=0.942, P<.001). Mean differences and limits of agreement showed more negative spherical equivalent refraction with wavefront analyzers (OPD-Scan, 0.406 +/- 0.768 D [range: 0.235 to 0.580 D] [P<.001]; WASCA, 0.511 +/- 0.550 D [range: 0.390 to 0.634 D] [P<.001]; and Allegretto, 0.434 +/- 0.904 D [range: 0.233 to 0.635 D] [P<.001]). A second analysis eliminating outliers showed the same trend but lower differences: OPD-Scan (n=75), 0.24 +/- 0.41 D (range: 0.15 to 0.34 D) (P<.001); WASCA (n=78), 0.46 +/- 0.47 D (range: 0.36 to 0.57 D) (P<.001); and Allegretto (n=77), 0.30 +/- 0.62 D (range: 0.16 to 0.44 D) (P<.001). No statistically significant differences were noted for J0 and J45. CONCLUSIONS: Wavefront analyzer refraction resulted in 0.30 D more myopia compared to SRW-5000 refraction in eyes without cycloplegia. This is the result of the accommodation excess attributable to instrument myopia. For the relatively low degrees of astigmatism in this study (<2.0 D), good agreement was noted between wavefront analyzers and the SRW-5000. Copyright (C) 2006 SLACK Incorporated

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE:To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS:Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS:Pupil size decreased by 0.62+/-0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS:Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Optometrists are becoming more integrally involved in the diagnosis of and care for glaucoma patients in the UK. The correlation of apparent change in non contact tonometry (NCT) IOP measurement and change in other ocular parameters such as refractive error, corneal curvature, corneal thickness and treatment zone size (data available to optometrists after LASIK) would facilitate care of these patients. Setting: A UK Laser Eye Clinic. Methods: This is a retrospective study study of 200 sequential eyes with myopia with or without astigmatism which underwent LASIK using a Hansatome and an Alcon LADARvision 4000 excimer laser. Refraction keratometry, pachymetry and NCT IOP mesurements were taken before treatmebnt and agian 3 months after treatment. The relationship between these variables anfd teh treatment zones were studied using stepwise multiple regression analysis. Results: There was a mean difference of 5.54mmHg comnparing pre and postoperative NCT IOP. IOP change correlates with refractive error change (P < 0.001), preoperative corneal thickness (P < 0.001) and treatment zone size (P = 0.047). Preoperative corneal thickness correlates with preoperative IOP (P < 0.001) and postoperative IOP (P < 0.001). Using these correlations, the measured difference in NCT IIOP can be predicted preoperatively or postoperatively using derived equations.Conclusion: There is a significant reduction in measured NCT IOP after LASIK. The amount of reduction can be calculated using data acquired by optometrists. This is helpful for opthalmologists and optometrists who co-manage glaucoma patients who have had LASIK or with glaucoma pateints who are consideraing having LASIK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. Methods The Northern Ireland Childhood Errors of Refraction (NICER) study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. Results Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. Conclusions Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study investigated the central and peripheral corneal characteristics of groups of subjects from 20 to 90 years of age to assist the understanding of ageing changes in the cornea, and to see whether relationships between ocular parameters were revealed. After age 45 the corneal horizontal radius of curvature gradually decreased with age. This trend was shown by the Aston University subjects (group B). The effect was very significant for the hospital patients undergoing biometry before cataract extraction operation (group D). Vertical radius of curvature showed a slight decrease with age after age 45, but similar to corneal eccentricity, this showed no significant age effect. Corneal astigmatism progressed from with the rule towards against the rule, particularly after age 60. The shift seemed mainly due to the decreasing horizontal corneal curvature. In biometry no significant age relation was found for axial length, but a significant relation was found between curvature and axial length in the larger group D. Lens thickness showed a very significant relation to age and to axial length, but no significant relation to corneal curvature. Anterior chamber depth showed a very significant relation to age, lens thickness and axial length, but no significant relation to corneal curvature. A significant age effect was found for corneal thickness decreasing with age for the central, nasal and temporal regions of the right eye. Analysis of the biometry results indicated the influence of two major factors. Firstly, the natural growth of the eye in youth, leading to greater values of axial length, radius of corneal curvature, lens thickness and anterior chamber depth. Secondly, the typical ageing changes where the increasing lens thickness caused a reduction in anterior chamber depth. The decrease in corneal thickness with age shown in some corneal regions may be a sign of ageing changes in the tissue proteins and hydration balance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous research has indicated that schematic eyes incorporating aspheric surfaces but lacking gradient index are unable to model ocular spherical aberration and peripheral astigmatism simultaneously. This limits their use as wide-angle schematic eyes. This thesis challenges this assumption by investigating the flexibility of schematic eyes comprising aspheric optical surfaces and homogeneous optical media. The full variation of ocular component dimensions found in human eyes was established from the literature. Schematic eye parameter variants were limited to these dimensions. The levels of spherical aberration and peripheral astigmatism modelled by these schematic eyes were compared to the range of measured levels. These were also established from the literature. To simplify comparison of modelled and measured data, single value parameters were introduced; the spherical aberration function (SAF), and peripheral astigmatism function (PAF). Some ocular components variations produced a wide range of aberrations without exceeding the limits of human ocular components. The effect of ocular component variations on coma was also investigated, but no comparison could be made as no empirical data exists. It was demonstrated that by combined manipulation of a number of parameters in the schematic eyes it was possible to model all levels of ocular spherical aberration and peripheral astigmatism. However, the unique parameters of a human eye could not be obtained in this way, as a number of models could be used to produce the same spherical aberration and peripheral astigmatism, while giving very different coma levels. It was concluded that these schematic eyes are flexible enough to model the monochromatic aberrations tested, the absence of gradient index being compensated for by altering the asphericity of one or more surfaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extent to which the surface parameters of Progressive Addition Lenses (PALs) affect successful patient tolerance was investigated. Several optico-physical evaluation techniques were employed, including a newly constructed surface reflection device which was shown to be of value for assessing semi-finished PAL blanks. Detailed physical analysis was undertaken using a computer-controlled focimeter and from these data, iso-cylindrical and mean spherical plots were produced for each PAL studied. Base curve power was shown to have little impact upon the distribution of PAL astigmatism. A power increase in reading addition primarily caused a lengthening and narrowing of the lens progression channel. Empirical measurements also indicated a marginal steepening of the progression power gradient with an increase in reading addition power. A sample of the PAL wearing population were studied using patient records and questionnaire analysis (90% were returned). This subjective analysis revealed the reading portion to be the most troublesome lens zone and showed that patients with high astigmatism (> 2.00D) adapt more readily to PALs than those with spherical or low cylindrical (2.00D) corrections. The psychophysical features of PALs were then investigated. Both grafting visual acuity (VA) and contrast sensitivity (CS) were shown to be reduced with an increase in eccentricity from the central umbilical line. Two sample populations (N= 20) of successful and unsuccessful PAL wearers were assessed for differences in their visual performance and their adaptation to optically induced distortion. The possibility of dispensing errors being the cause of poor patient tolerance amongst the unsuccessful wearer group was investigated and discounted. The contrast sensitivity of the successful group was significantly greater than that of the unsuccessful group. No differences in adaptation to or detection of curvature distortion were evinced between these presbyopic groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Distortion or deprivation of vision during an early `critical' period of visual development can result in permanent visual impairment which indicates the need to identify and treat visually at-risk individuals early. A significant difficulty in this respect is that conventional, subjective methods of visual acuity determination are ineffective before approximately three years of age. In laboratory studies, infant visual function has been quantified precisely, using objective methods based on visual evoked potentials (VEP), preferential looking (PL) and optokinetic nystagmus (OKN) but clinical assessment of infant vision has presented a particular difficulty. An initial aim of this study was to evaluate the relative clinical merits of the three techniques. Clinical derivatives were devised, the OKN method proved unsuitable but the PL and VEP methods were evaluated in a pilot study. Most infants participating in the study had known ocular and/or neurological abnormalities but a few normals were included for comparison. The study suggested that the PL method was more clinically appropriate for the objective assessment of infant acuity. A study of normal visual development from birth to one year was subsequently conducted. Observations included cycloplegic refraction, ophthalmoscopy and preferential looking visual acuity assessment using horizontally and vertically oriented square wave gratings. The aims of the work were to investigate the efficiency and sensitivity of the technique and to study possible correlates of visual development. The success rate of the PL method varied with age; 87% of newborns and 98% of infants attending follow-up successfully completed at least one acuity test. Below two months monocular acuities were difficult to secure; infants were most testable around six months. The results produced were similar to published data using the acuity card procedure and slightly lower than, but comparable with acuity data derived using extended PL methods. Acuity development was not impaired in infants found to have retinal haemorrhages as newborns. A significant relationship was found between newborn binocular acuity and anisometropia but not with other refractive findings. No strong or consistent correlations between grating acuity and refraction were found for three, six or twelve months olds. Improvements in acuity and decreases in levels of hyperopia over the first week of life were suggestive of recovery from minor birth trauma. The refractive data was analysed separately to investigate the natural history of refraction in normal infants. Most newborns (80%) were hyperopic, significant astigmatism was found in 86% and significant anisometropia in 22%. No significant alteration in spherical equivalent refraction was noted between birth and three months, a significant reduction in hyperopia was evident by six months and this trend continued until one year. Observations on the astigmatic component of the refractive error revealed a rather erratic series of changes which would be worthy of further investigation since a repeat refraction study suggested difficulties in obtaining stable measurements in newborns. Astigmatism tended to decrease between birth and three months, increased significantly from three to six months and decreased significantly from six to twelve months. A constant decrease in the degree of anisometropia was evident throughout the first year. These findings have implications for the correction of infantile refractive error.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work utilising a new material for contact lenses has fallen into three parts: Physioloeical considerations: Since the cornea is devoid of blood vessels, its oxygen is derived from the atmosphere. Early hydrophilic gel contact lenses interrupted the flow of oxygen and corneal insult resulted. Three techniques of fenestration were tried to overcome this problem. High speed drilling with 0.1 mm diameter twist drills. was found to be mechanically successful, but under clinical conditions mucous blockage of the fenestrations occurred. An investigation was made into the amount of oxygen arriving at the corneal interface; related to gel lens thickness. The results indicated an improvement in corneal oxygen as lens thickness was reduced. The mechanism is thought to be a form of mechanical pump. A series of clinical studies con:firmed the experimental work; the use of thin lenses removing the symptoms of corneal hypoxia. Design: The parameters of lens back curvature. lens thickness and lens diameter have been isolated and related to three criteria of vision (a) Visual acuity. (b) Visual stability and (c) Induced astigmatism. From the results achieved a revised and basically successful design of lens has been developed. Comparative study: The developed form of lens was compared with traditional lenses in a controlled survey. Twelve factors were assessed over a twenty week period of wear using a total of eighty four patients. The results of this study indicate that whilst the expected changes were noted with the traditional lens wearers, gel lens wearers showed no discernible change in any of the factors measured. ldth the exception of' one parameter. In addition to a description of' the completed l'iork. further investigations are ·sug~ested l'lhich. it is hoped. l'iould further improve the optical performance of gel lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the stability of the Akreos AO intraocular lens (IOL) platform with a simulated toric design using objective image analysis. Setting: Six hospital eye clinics across Europe. Methods: After implantation in 1 eye of patients, IOLs with orientation marks were imaged at 1 to 2 days, 7 to 14 days, 30 to 60 days, and 120 to 180 days. The axis of rotation and IOL centration were objectively assessed using validated image analysis. Results: The study enrolled 107 patients with a mean age of 69.9 years ± 7.7 (SD). The image quality was sufficient for IOL rotation analysis in 91% of eyes. The mean rotation between the first day postoperatively and 120 to 180 days was 1.93 ± 2.33 degrees, with 96% of IOLs rotating fewer than 5 degrees and 99% rotating fewer than 10 degrees. There was no significant rotation between visits and no clear bias in the direction of rotation. In 71% of eyes, the dilation and image quality was sufficient for image analysis of centration. The mean change in centration between 1 day and 120 to 180 days was 0.21 ± 0.11 mm, with all IOLs decentering less than 0.5 mm. There was no significant decentration between visits and no clear bias in the direction of the decentration. Conclusion: Objective analysis of digital retroillumination images taken at different postoperative periods shows the aspheric IOL platform was stable in the eye and is therefore suitable for the application of a toric surface to correct corneal astigmatism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To compare axial length growth between white children with myopia wearing orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) over a 2-year period. METHODS. Subjects 6 to 12 years of age with myopia -0.75 to -4.00 diopters of sphere (DS) and astigmatism ≤1.00 diopters of cylinder (DC) were prospectively allocated OK or SV correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals. RESULTS. Thirty-one children were fitted with OK and 30 with SV. Following 24 months, axial length increased significantly over time for both the OK group (0.47 mm) and SV group (0.69 mm; P < 0.001), with a significant interaction between time and group (P = 0.05) reflecting a greater increase in the SV group. Significant differences in refraction were found over time, between groups and for the interaction between time and group for spherical (all P < 0.001) but not cylindrical components of refraction (all P > 0.05). Significantly greater corneal flattening was evident in the OK group for the flatter and steeper corneal powers and for corneal shape factor (all P ≤0.05). CONCLUSIONS. Orthokeratology contact lens wear reduces axial elongation in comparison to distance single-vision spectacles in children. © 2012 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the clinical outcomes after implantation of a new hydrophobic acrylic toric intraocular lens (IOL) to correct preexisting corneal astigmatism in patients having routine cataract surgery. SETTING: Four hospital eye clinics throughout Europe. DESIGN: Cohort study. METHODS: This study included eyes with at least 0.75 diopter (D) of preexisting corneal astigmatism having routine cataract surgery. Phacoemulsification was performed followed by insertion and alignment of a Tecnis toric IOL. Patients were examined 4 to 8 weeks postoperatively; uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction, and keratometry were measured. Individual patient satisfaction with uncorrected vision and the surgeon’s assessment of ease of handling and performance of the IOL were also documented. The cylinder axis of the toric IOL was determined by dilated slitlamp examination. RESULTS: The study enrolled 67 eyes of 60 patients. Four to 8 weeks postoperatively, the mean UDVA was 0.15 logMAR G 0.17 (SD) and the UDVA was 20/40 or better in 88% of eyes. The mean refractive cylinder decreased significantly postoperatively, from -1.91 +/- 1.07 D to -0.67 +/- 0.54 D. No significant change in keratometric cylinder was observed. The mean absolute IOL misalignment from the intended axis was 3.4 degrees (range 0 to 12 degrees). The good UDVA resulted in high levels of patient satisfaction. CONCLUSION: Implantation of the new toric IOL was an effective, safe, and predictable method to manage corneal astigmatism in patients having routine cataract surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Premium intraocular lenses (IOLs) aim to surgically correct astigmatism and presbyopia following cataract extraction, optimising vision and eliminating the need for cataract surgery in later years. It is usual to fully correct astigmatism and to provide visual correction for distance and near when prescribing spectacles and contact lenses, however for correction with the lens implanted during cataract surgery, patients are required to purchase the premium IOLs and pay surgery fees outside the National Health Service in the UK. The benefit of using toric IOLs was thus demonstrated, both in standard visual tests and real-world situations. Orientation of toric IOLs during implantation is critical and the benefit of using conjunctival blood vessels for alignment was shown. The issue of centration of IOLs relative to the pupil was also investigated, showing changes with the amount of dilation and repeat dilation evaluation, which must be considered during surgery to optimize the visual performance of premium IOLs. Presbyopia is a global issue, of growing importance as life expectancy increases, with no real long-term cure. Despite enhanced lifestyles, changes in diet and improved medical care, presbyopia still presents in modern life as a significant visual impairment. The onset of presbyopia was found to vary with risk factors including alcohol consumption, smoking, UV exposure and even weight as well as age. A new technique to make measurement of accommodation more objective and robust was explored, although needs for further design modifications were identified. Due to dysphotopsia and lack of intermediate vision through most multifocal IOL designs, the development of a trifocal IOL was shown to minimize these aspects. The current thesis, therefore, emphasises the challenges of premium IOL surgery and need for refinement for optimum visual outcome in addition to outlining how premium IOLs may provide long-term and successful correction of astigmatism and presbyopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Evaluating the impact of splitting toric power on patient tolerance to misorientation such as with intraocular lens rotation. Setting: University vision clinic. Methods: Healthy, non astigmats had +1.50D astigmatism induced with spectacle lenses at 90°, 135°, 180° and +3.00D at 90°. Two correcting cylindrical lenses of the opposite sign and half the power each were subsequently added to the trial frame misaligned by 0°, 5° or 10° in a random order and misorientated from the initial axis in a clockwise direction by up to 15° in 5° steps. A second group of adapted astigmats with between 1.00 and 3.00DC had their astigmatism corrected with two toric spectacle lenses of half the power separated by 0°, 5° or 10° and misorientated from the initial axis in both directions by up to 15° in 5° steps. Distance, high contrast visual acuity was measured using a computerised test chart at each lens misalignment and misorientation. Results: Misorientation of the split toric lenses caused a statistically significant drop in visual acuity (F= 70.341; p< 0.001). Comparatively better acuities were observed around 180°, as anticipated (F= 3.775; p= 0.035). Misaligning the split toric power produced no benefit in visual acuity retention with axis misorientation when subjects had astigmatism induced with a low (F= 2.190, p= 0.129) or high cylinder (F= 0.491, p= 0.617) or in the adapted astigmats (F= 0.120, p= 0.887). Conclusion: Misalignment of toric lens power split across the front and back lens surfaces had no beneficial effect on distance visual acuity, but also no negative effect. © 2013 British Contact Lens Association.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To assess the relative clinical success of orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) in children in terms of incidences of adverse events and discontinuations over a 2-year period. Methods. Sixty-one subjects 6 to 12 years of age with myopia of - 0.75 to - 4.00DS and astigmatism =1.00DC were prospectively allocated OK or SV correction. Subjects were followed at 6-month intervals and advised to report to the clinic immediately should adverse events occur. Adverse events were categorized into serious, significant, and non-significant. Discontinuation was defined as cessation of lens wear for the remainder of the study. Results. Thirty-one children were corrected with OK and 30 with SV. A higher incidence of adverse events was found with OK compared with SV (p < 0.001). Nine OK subjects experienced 16 adverse events (7 significant and 9 non-significant). No adverse events were found in the SV group. Most adverse events were found between 6 and 12 months of lens wear, with 11 solely attributable to OK wear. Significantly more discontinuations were found with SV in comparison with OK (p < 0.05). Conclusions. The relatively low incidence of adverse events and discontinuations with OK is conducive for the correction of myopia in children with OK contact lenses.