960 resultados para Arch of hollow cathode


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Through the comparative analysis of primary freshwater fishes in Chinese continent and the Taiwan Island, we summarize the three distinctions of distribution of freshwater fishes in these areas: (i) there exists a high similarity of freshwater fish fauna between Taiwan and the southeastern shore of the continent; (ii) some species of freshwater fish are found both in the Taiwan Island and East Himalayans; (iii) different freshwater fishes have different distributions in island arch of western Pacific where Taiwan is located, but the distribution pattern shows a similarity to that of adjacent continent. The characteristic distributions of the fishes are closely related to the change in paleogeography and geology in the area. The parsimony analysis of endemicity (PAE analysis) indicates that the three distribution patterns can be explained by the vicariance theory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adoption of a sintered stainless steel fiber felt was evaluated as gas diffusion backing in air-breathing direct methanol fuel cell (DMFC). By using a sintered stainless steel fiber felt as an anodic gas diffusion backing, the peak power density of an air-breathing DMFC is 24 mW cm(-2), which is better than that of common carbon paper. A 30-h-life test indicates that the degraded performance of the air-breathing DMFC is primarily due to the water flooding of the cathode. Twelve unit cells with each has 6 cm(2) of active area are connected in series to supply the power to a mobile phone assisted by a constant voltage diode. The maximum power density of 26 mW cm(-2) was achieved in the stack, which is higher than that in single cell. The results show that the sintered stainless steel felt is a promising solution to gas diffusion backing in the air-breathing DMFC, especially in the anodic side because of its high electronical conductivity and hydrophilicity. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hollow deoxyribonucleic acid (DNA)/poly-L-lysine (PLL) capsules were successfully fabricated through a layer-by-layer (LbL) self-assembly of DNA and PLL on porous CaCO3 microparticles, followed by removal of templates with ethylenediamine tetraacetic acid disodium salt (EDTA). The enzymatic degradation of the capsules in the presence of alpha-chymotrypsin was explored. The higher the enzyme concentration, the higher is the degradation rate of hollow capsules. in addition, glutaric dialdehyde (GA) cross-linking was found to be another way to manipulate degradation rate of hollow capsules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of template phase on the structures of as-synthesized silica nanoparticles with fragile DDAB vesicles as templates is reported. It is found that the template phase plays a critical role in the growth process of silica: the unstable DDAB vesicles in liquid-crystalline phase often lead to the formation of mesostructured solid spheres, and the rather stable DDAB vesicles in gel phase lead to the formation of hollow spheres with less mesostructures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Well-faceted hexagonal ZnO microprisms with regular interior space have been successfully prepared by a template-free hydrothermal synthetic route. The morphologies of the products depend on the experimental conditions such as the solvent, the concentration of ammonia aqueous solution, and the reaction temperature. Through manipulation of the aging time, the as-prepared ZnO can be controlled as a monodispersed hexagonal twinning solid or as hollow microprisms. Moreover, the evolution process of the hollow ZnO nanoarchitecture after reaction for 2, 6, 12, and 24 h has been investigated by field emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM). A possible growth mechanism has also been proposed and discussed. Furthermore, the photoluminescence (PL) measurement exhibits the unique emitting characteristic of hollow ZnO nanostructures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A numerical analysis of galvanic corrosion of hot-dip galvanized steel immersed in seawater was presented. The analysis was based on the boundary element methods (BEMs) coupled with Newton-Raphson iterative technique to treat the nonlinear boundary conditions, which were determined by the experimental polarization curves. Results showed that galvanic current density concentrates on the boundary of steel substrate and zinc coating, and the sacrificial protection of zinc coating to steel substrate results in overprotection of steel cathode. Not only oxygen reduction but also hydrogen reduction could occur as cathode reactions, which probably led up to the adsorption and absorption of hydrogen atoms. Flat galvanized steel tensile sample shows a brittle behavior similar to hydrogen embrittlement according to the SSRT (show strain rate test) in seawater.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This PhD thesis investigates the application of hollow core photonic crystal fibre for use as an optical fibre nano litre liquid sensor. The use of hollow core photonic crystal fibre for optical fibre sensing is influenced by the vast wealth of knowledge, and years of research that has been conducted for optical waveguides. Hollow core photonic crystal fibres have the potential for use as a simple, rapid and continuous sensor for a wide range of applications. In this thesis, the velocity of a liquid flowing through the core of the fibre (driven by capillary forces) is used for the determination of the viscosity of a liquid. The structure of the hollow core photonic crystal fibre is harnessed to collect Raman scatter from the sample liquid. These two methods are integrated to investigate the range of applications the hollow core photonic crystal fibre can be utilised for as an optical liquid sensor. Understanding the guidance properties of hollow core photonic crystal fibre is forefront in dynamically monitoring the liquid filling. When liquid is inserted fully or selectively to the capillaries, the propagation properties change from photonic bandgap guidance when empty, to index guidance when the core only is filled and finally to a shifted photonic bandgap effect, when the capillaries are fully filled. The alterations to the guidance are exploited for all viscosity and Raman scattering measurements. The concept of the optical fibre viscosity sensor was tested for a wide range of samples, from aqueous solutions of propan-1-ol to solutions of mono-saccharides in phosphate buffer saline. The samples chosen to test the concept were selected after careful consideration of the importance of the liquid in medical and industrial applications. The Raman scattering of a wide range of biological important fluids, such as creatinine, glucose and lactate were investigated, some for the first time with hollow core photonic crystal fibre.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Galvanic replacement is a versatile synthetic strategy for the synthesis of alloy and hollow nanostructures. The structural evolution of single crystalline and multiply twinned nanoparticles <20 nm in diameter and capped with oleylamine is systematically studied. Changes in chemical composition are dependent on the size and crystallinity of the parent nanoparticle. The effects of reaction temperature and rate of precursor addition are also investigated. Galvanic replacement of single crystal spherical and truncated cubic nanoparticles follows the same mechanism to form hollow octahedral nanoparticles, a mechanism which is not observed for galvanic replacement of Ag templates in aqueous systems. Multiply twinned nanoparticles can form nanorings or solid alloys by manipulating the reaction conditions. Oleylamine-capped Ag nanoparticles are highly adaptable templates to synthesize a range of hollow and alloy nanostructures with tuneable localised surface plasmon resonance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new type of direct current, high-density, and low electron temperature reflex plasma source, obtained as a hybrid between a modified hollow-cathode discharge and a Penning ionization gauge discharge is presented. The plasma source was tested in argon, nitrogen, and oxygen over a range pressure of 1.0-10(-3) mbar, discharge currents 20-200 mA, and magnetic field 0-120 Gauss. Both external parameters, such as breakdown potential and the discharge voltage-current characteristic, and its internal parameters, like the electron energy distribution function, electron and ion densities, and electron temperature, were measured. Due to the enhanced hollow-cathode effect by the magnetic trapping of electrons, the density of the bulk plasma is as high as 10(18) m(-3), and the electron temperature is as low as a few tenths of electron volts. The plasma density scales with the dissipated power. Another important feature of this reflex plasma source is its high degree of uniformity, while the discharge bulk region is free of an electric field. (C) 2004 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of high-impedance surfaces (HISs) to increase the frequency-scanning sensitivity of hollow leaky-wave antennas (LWAs) is presented. The LWA consists of a hollow rectangular waveguide with one of its narrow walls replaced by a partially reflective surface, and it is loaded with a metallodielectric HIS to increase its beam-scanning response. Theoretical results based on a simple transverse equivalent network illustrate the physical mechanism responsible for the improvement, and they are verified by experiments on a prototype working in the 11-16 GHz band.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study aimed to compare the cost effectiveness of conventional treatment using partial dentures with functionally-orientated treatment based on the shortened dental arch concept to replace missing teeth for partially dentate elders.
Methods: 44 partially dentate patients aged 65 years and older were recruited following routine dental assessment at a university dental hospital. Patients consented to and were randomly assigned to the two treatment arms. The conventional treatment group received a removable partial denture to replace all missing natural teeth. The functionally-orientated group were restored to a shortened dental arch of 10 occluding contacts using resin bonded bridgework. The costs associated with each treatment were recorded including laboratory charges, treatment time and opportunity costs. The impact on quality of life (OHRQoL) was measured using the 14-item Oral Health Impact Profile.
Results: Both groups reported improvements in OHRQoL after completion of treatment. For the conventional group, the mean OHIP-14 score decreased from 12.4 pre-operatively to 3.3 post-operatively (p<0.001). In the functionally-orientated group the OHIP-14 score decreased from 11.4 to 1.8 following treatment (p<0.001). On average the conventional treatment group required 8.3 clinic visits as compared to 4.4 visits for the functionally-orientated group. The mean total treatment time was 183 minutes 19 seconds for the conventional group versus 124 minutes 8 seconds for the functionally-orientated group. The conventional treatment group had an average of 6.33 teeth replaced at a laboratory cost of 337.31 Euros. The functionally-orientated group had an average of 2.64 teeth replaced at a laboratory cost of 244.05 Euros.
Conclusions: Restoration to a shortened dental arch using functionally-orientated treatment resulted in a similar improvement in OHRQoL with fewer clinic visits, less operative time and at a lower laboratory cost compared with conventional treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to verify the possibility to use a polarized graphite electrode as an electron donor for the reductive dechlorination of 1,2-dichloroethane, an ubiquitous groundwater contaminant. The rate of 1,2-DCA dechlorination almost linearly increased by decreasing the set cathode potential over a broad range of set cathode potentials (i.e., from −300 mV to −900 mV vs. the standard hydrogen electrode). This process was primarily dependent on electrolytic H2 generation. On the other hand, reductive dechlorination proceeded (although quite slowly) with a very high Coulombic efficiency (near 70%) at a set cathode potential of −300 mV, where no H2 production occurred. Under this condition, reductive dechlorination was likely driven by direct electron uptake from the surface of the polarized electrode. Taken as a whole, this study further extends the range of chlorinated contaminants which can be treated with bioelectrochemical systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The distally based anterolateral thigh (ALT) flap is an interesting reconstructive solution for complex soft tissue defects of the knee. In spite of a low donor site morbidity and wide covering surface as well as arch of rotation, it has never gained popularity among reconstructive surgeons. Venous congestion and difficult flap dissection in the presence of a variable anatomy of the vascular pedicle are the possible reasons.Methods An anatomical study of 15 cadaver legs was performed to further clarify the blood supply of the distally based ALT. Our early experience with the use of preoperative angiography and a safe flap design modification that avoids distal intramuscular skeletonization of the vascular pedicle and includes a subcutaneous strip ranging from the distal end of the flap to the pivot point is presented.Results The distally based ALT presents a constant and reliable retrograde vascular contribution from the superior genicular artery. Preoperative angiography reliably identified and avoided critical Shieh Type II pedicled flaps. The preservation of a subcutaneous strip ranging from the distal flap end to the upper knee was associated with the absence of venous congestion in a short case series.Conclusions Preoperative angiography and a flap design modification are proposed to allow the safe transfer of the distally based ALT to reconstruct soft tissue defects of the knee.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the study was to investigate the relative contribution of skate blade properties to on-ice skating speed. Thirty-two male ice hockey players (mean age = 19±2.65 yrs.) representing the Ontario Minor Hockey Association (OMHA; Midget AAA and Junior), Canadian Inter University Sport (CIS: Varsity), Ontario hockey league (OHL) and East Coast Hockey League (ECHL), and the playing positions of forwards (n=18) and defense (n=14) were recruited to participate. Skate related equipment worn by the players for the purpose of the research was documented and revealed that 80% of the players wore Bauer skates, Tuuk blade holders and LS2 skate blades. Subjects completed a battery of eight on-ice skating drills used to measure and compare two aspects of skating speed; acceleration [T1(s)] and total time to complete each drill [TT(s)] while skating on three skate blade conditions. The drills represented skills used in the game of hockey, both in isolation (e.g., forward skating, backward skating, stops and starts, and cornering) and in sequence to simulate the combination of skills used in a shift of game play. The three blade conditions consisted of (i) baseline, represented by the blades worn by the player throughout their current season of play; (ii) experimental blades (EB), represented by brand name experimental blades with manufacturers radius of contour and a standardized radius of hollow; and (iii) customized experimental blades (CEB), represented by the same brand name experimental blades sharpened to the players’ preference as identified in the baseline condition. No significant differences were found in acceleration time [T1(s)] or total time to complete [TT(s)] the isolated drills across blade conditions; however significant differences were revealed in both T1(s) and TT(s) measured during the execution of the sequenced drill across blade conditions. A iii Bonferroni post hoc test revealed that players skated significantly faster when skating on the CEB condition compared to the baseline condition (p≤.05). A questionnaire assessing subjects perceived comfort, confidence and effort expended while skating on the experimental blades revealed that players were significantly more comfortable when skating on the CEB versus the EB condition (p≤.05). Outcomes of the study provide evidence to suggest that the experimental skate blades customized with the players preferred blade sharpening characteristics results in faster skating speed in a combination drill representing skills performed in gameplay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The radiation characteristics of a new type of hollow dielectric H-plane sectoral horn antenna are presented. Metallic strips of optimum length are loaded on the H-walls of the sectoral horns. The effects of strip loading for producing square patterns in the H plane are discussed.