882 resultados para Arc measures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate monitoring of prevalence and trends in population levels of physical activity (PA) is a fundamental public health need. Test-retest reliability (repeatability) was assessed in population samples for four self-report PA measures: the Active Australia survey (AA, N=356), the short International Physical Activity Questionnaire (IPAQ, N=104), the physical activity items in the Behavioral Risk Factor Surveillance System (BRFSS, N=127) and in the Australian National Health Survey (NHS, N=122). Percent agreement and Kappa statistics were used to assess reliability of classification of activity status as 'active', 'insufficiently active' or 'sedentary'. Intraclass correlations (ICCs) were used to assess agreement on minutes of activity reported for each item of each survey and for total minutes. Percent agreement scores for activity status were very good on all four instruments, ranging from 60% for the NHS to 79% for the IPAQ. Corresponding Kappa statistics ranged from 0.40 (NHS) to 0.52 (AA). For individual items, ICCs were highest for walking (0.45 to 0.78) and vigorous activity (0.22 to 0.64) and lowest for the moderate questions (0.16 to 0.44). All four measures provide acceptable levels of test-retest reliability for assessing both activity status and sedentariness, and moderate reliability for assessing total minutes of activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With measurement of physical activity becoming more common in clinical practice, it is imperative that healthcare professionals become more knowledgeable about the different methods available to objectively measure physical activity behaviour. Objective measures do not rely on information provided by the patient, but instead measure and record the biomechanical or physiological consequences of performing physical activity, often in real time. As such, objective measures are not subject to the reporting bias or recall problems associated with self-report methods. The purpose of this article was to provide an overview of the different methods used to objectively measure physical activity in clinical practice. The review was delimited to heart rate monitoring, accelerometers and pedometers since their small size, low participant burden and relatively low cost make these objective measures appropriate for use in clinical practice settings. For each measure, strengths and weakness were discussed; and whenever possible, literature-based examples of implementation were provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was undertaken to investigate any relationship between sensory features and neck pain in female office workers using quantitative sensory measures to better understand neck pain in this group. Office workers who used a visual display monitor for more than four hours per day with varying levels of neck pain and disability were eligible for inclusion. There were 85 participants categorized according to their scores on the neck disability index (NDI): 33 with no pain (NDI < 8); 38 with mild levels of pain and disability (NDI 9–29); 14 with moderate levels of pain (NDI ⩾ 30). A fourth group of women without neck pain (n = 22) who did not work formed the control group. Measures included: thermal pain thresholds over the posterior cervical spine; pressure pain thresholds over the posterior neck, trapezius, levator scapulae and tibialis anterior muscles, and the median nerve trunk; sensitivity to vibrotactile stimulus over areas of the hand innervated by the median, ulnar and radial nerves; sympathetic vasoconstrictor response. All tests were conducted bilaterally. ANCOVA models were used to determine group differences between the means for each sensory measure. Office workers with greater self-reported neck pain demonstrated hyperalgesia to thermal stimuli over the neck, hyperalgesia to pressure stimulation over several sites tested; hypoaesthesia to vibration stimulation but no changes in the sympathetic vasoconstrictor response. There is evidence of multiple peripheral nerve dysfunction with widespread sensitivity most likely due to altered central nociceptive processing initiated and sustained by nociceptive input from the periphery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Accelerometers have become one of the most common methods of measuring physical activity (PA). Thus, validity of accelerometer data reduction approaches remains an important research area. Yet, few studies directly compare data reduction approaches and other PA measures in free-living samples. Objective To compare PA estimates provided by 3 accelerometer data reduction approaches, steps, and 2 self-reported estimates: Crouter's 2-regression model, Crouter's refined 2-regression model, the weighted cut-point method adopted in the National Health and Nutrition Examination Survey (NHANES; 2003-2004 and 2005-2006 cycles), steps, IPAQ, and 7-day PA recall. Methods A worksite sample (N = 87) completed online-surveys and wore ActiGraph GT1M accelerometers and pedometers (SW-200) during waking hours for 7 consecutive days. Daily time spent in sedentary, light, moderate, and vigorous intensity activity and percentage of participants meeting PA recommendations were calculated and compared. Results Crouter's 2-regression (161.8 +/- 52.3 minutes/day) and refined 2-regression (137.6 +/- 40.3 minutes/day) models provided significantly higher estimates of moderate and vigorous PA and proportions of those meeting PA recommendations (91% and 92%, respectively) as compared with the NHANES weighted cut-point method (39.5 +/- 20.2 minutes/day, 18%). Differences between other measures were also significant. Conclusions When comparing 3 accelerometer cut-point methods, steps, and self-report measures, estimates of PA participation vary substantially.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of this study was to establish the minimal number of days of monitoring required for accelerometers to assess usual physical activity in children. Methods A total of 381 students (189 M, 192 F) wore a CSA 7164 uniaxial accelerometer for seven consecutive days. To examine age-related trends students were grouped as follows: Group I: grades 1-3 (N = 92); Group II: grades 4-6 (N = 98); Group III: grades 7-9 (N = 97); Group IV: grades 10-12 (N = 94). Average daily time spent in moderate-to-vigorous physical activity (MVPA) was calculated from minute-by-minute activity counts using the regression equation developed by Freedson et al. (1997). Results Compared with adolescents in grades 7 to 12, children in grades 1 to 6 exhibited less day-to-day variability in MVPA behavior. Spearman-Brown analysts indicated that between 4 and 5 d of monitoring would be necessary to a achieve a reliability of 0.80 in children, and between 8 and 9 d of monitoring would be necessary to achieve a reliability of 0.80 in adolescents. Within all grade levels, the 7-d monitoring protocol produced acceptable estimates of daily participation in MVPA (R = 0.76 (0.71-0.81) to 0.87 (0.84-0.90)). Compared with weekdays, children exhibited significantly higher levels of MVPA on weekends, whereas adolescents exhibited significantly lower levels of MVPA on weekends. Principal components analysis revealed two distinct time components for MVPA during the day for children (early morning, rest of the day), and three distinct time components for MVPA during the day for adolescents (morning, afternoon, early evening). Conclusions These results indicate that a 7-d monitoring protocol provides reliable estimates of usual physical activity behavior in children and adolescents and accounts for potentially important differences in weekend versus weekday activity behavior as well as differences in activity patterns within a given day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Accurate monitoring of prevalence and trends in population levels of physical activity is fundamental to the planning of health promotion and disease-prevention strategies. Test-retest reliability (repeatability) was assessed for four self-report measures of physical activity commonly used in population surveys: the Active Australia survey (AA, N=356), the short form of the International Physical Activity Questionnaire (IPAQ-S, N=104), the physical activity items in the Behavioral Risk Factor Surveillance System (BRFSS, N=127) and the physical activity items in the Australian National Health Survey (NHS, N=122). METHODS Percent agreement and Kappa statistics were used to assess the reliability of classification of activity status (where ‘active’= 150 minutes of activity per week) and sedentariness (where ‘sedentary’ = reporting no physical activity). Intraclass correlations (ICCs) were used to assess agreement on minutes of activity reported for each item of each survey and on total minutes reported in each survey. RESULTS Percent agreement scores for both activity status and sedentariness were very good on all four instruments. Overall the percent agreement between repeated surveys was between 73% (NHS) and 87% (IPAQ) for the criterion measure of achieving 150 minutes per week, and between 77% (NHS) and 89% (IPAQ) for the criterion of being sedentary. Corresponding Kappa statistics ranged from 0.46 (NHS) to 0.61 (AA) for activity status and from 0.20 (BRFSS) to 0.52 (AA) for sedentariness. For the individual items ICCs were highest for walking (0.45 to 0.56) and vigorous activity (0.22 to 0.64) and lowest for the moderate questions (0.16 to 0.44). CONCLUSION All four measures provide acceptable levels of test-retest reliability for assessing both activity status and sedentariness, and moderate reliability for assessing total minutes of activity. Supported by the Australian Commonwealth Department of Health and Ageing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To better understand how freshwater ecosystems respond to changes in catchment land-use, it is important to develop measures of ecological health that include aspects of both ecosystem structure and function. This study investigated measures of nutrient processes as potential indicators of stream ecosystem health across a land-use gradient from relatively undisturbed to highly modified. A total of seven indicators (potential denitrification; an index of denitrification potential relative to sediment organic matter; benthic algal growth on artificial substrates amended with (a) N only, (b) P only, and (c) N and P; and δ15N of aquatic plants and benthic sediment) were measured at 53 streams in southeast Queensland, Australia. The indicators were evaluated by their response to a defined gradient of agricultural land-use disturbance as well as practical aspects of using the indicators as part of a monitoring program. Regression models based on descriptors of the disturbance gradient explained a large proportion of the variation in six of the seven indicators. Denitrification index, algal growth in N amended substrate, and δ15N of aquatic plants demonstrated the best regression. However, the δ15N value of benthic sediment was found to be the best indicator overall for incorporation into a monitoring program, as samples were relatively easy to collect and process, and were successfully collected at more than 90% of the study sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Graphene and carbon nanotubes are the most promising nanomaterials for application in various modern nanodevices. The successful production of the nanotubes and graphene in a single process was achieved by using a magnetically enhanced arc discharge in helium atmosphere between carbon and metal electrodes. A 3-D fluid model has been used to investigate the discharge parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arc discharge ablation with a catalyst-filled carbon anode in a helium background was used for the synthesis of graphene and carbon nanotubes. In this paper, we present the results of the numerical simulation of the distribution of various plasma parameters in discharge, as well as the distribution of carbon flux on the nanotube surface, for the typical discharge with an arc current of 60 A and a background gas pressure of 68 kPa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is demonstrated that a magnetic field has a profound effect on the length of a single-wall carbon nanotube (SWCNT) synthesized in the arc discharge. The average length of SWCNT increases by a factor of 2 in discharge with magnetic field as compared with the discharge without magnetic field, and the yield of long nanotubes with lengths above 5 μm also increases. A model of SWCNT growth on metal catalyst in arc plasma was developed. Monte-Carlo simulations confirm that the increase of the plasma density in the magnetic field leads to an increase in the nanotube growth rate and thus leads to longer nanotubes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach to large-scale production of high-quality graphene flakes in magnetically-enhanced arc discharges between carbon electrodes is reported. A non-uniform magnetic field is used to control the growth and deposition zones, where the Y-Ni catalyst experiences a transition to the ferromagnetic state, which in turn leads to the graphene deposition in a collection area. The quality of the produced material is characterized by the SEM, TEM, AFM, and Raman techniques. The proposed growth mechanism is supported by the nucleation and growth model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present results of computational simulations of tungsten-inert-gas and metal-inert-gas welding. The arc plasma and the electrodes (including the molten weld pool when necessary) are included self-consistently in the computational domain. It is shown, using three examples, that it would be impossible to accurately estimate the boundary conditions on the weld-pool surface without including the arc plasma in the computational domain. First, we show that the shielding gas composition strongly affects the properties of the arc that influence the weld pool: heat flux density, current density, shear stress and arc pressure at the weld-pool surface. Demixing is found to be important in some cases. Second, the vaporization of the weld-pool metal and the diffusion of the metal vapour into the arc plasma are found to decrease the heat flux density and current density to the weld pool. Finally, we show that the shape of the wire electrode in metal-inert-gas welding has a strong influence on flow velocities in the arc and the pressure and shear stress at the weld-pool surface. In each case, we present evidence that the geometry and depth of the weld pool depend strongly on the properties of the arc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unique properties of graphene and carbon nanotubes made them the most promising nanomaterials attracting enormous attention, due to the prospects for applications in various nanodevices, from nanoelectronics to sensors and energy conversion devices. Here we report on a novel deterministic, single-step approach to simultaneous production and magnetic separation of graphene flakes and carbon nanotubes in an arc discharge by splitting the high-temperature growth and low-temperature separation zones using a non-uniform magnetic field and tailor-designed catalyst alloy, and depositing nanotubes and graphene in different areas. Our results are very relevant to the development of commercially-viable, single-step production of bulk amounts of high-quality graphene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to control the properties of single-wall nanotubes (SWNTs) produced in the arc discharge is important for many practical applications. Our experiments suggest that the length of SWNTs significantly increases (up to 4000 nm), along with the purity of the carbon deposit, when the magnetic field is applied to arc discharge. Scanning electron microscopy and transmission electron microscopy analyses have demonstrated that the carbon deposit produced in the magnetic-field-enhanced arc mainly consists of the isolated and bunched SWNTs. A model of a carbon nanotube interaction and growth in the thermal plasma was developed, which considers several important effects such as anode ablation that supplies the carbon plasma in an anodic arc discharge technique, and the momentum, charge, and energy transfer processes between nanotube and plasma. It is shown that the nanotube charge with respect to the plasma as well as nanotube length depend on plasma density and electric field in the interelectrode gap. For instance, nanotube charge changes from negative to positive value with an electron density decrease. The numerical simulations based on the Monte Carlo technique were performed, which explain an increase in the nanotubes produced in the magnetic-field-enhanced arc discharge. © 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ability to control the properties of single-wall nanotubes produced in the arc discharge is important for many practical applications. Our experiments suggest that the length and purity of single-wall nanotubes significantly increase when the magnetic field is applied to the arc discharge. A model of a single wall carbon nanotube interaction and growth in the thermal plasma was developed which considers several important effects such as anode ablation that supplies the carbon plasma in an anodic arc discharge technique, and the momentum, charge and energy transfer processes between nanotube and plasma. The numerical simulations based on Monte-Carlo technique were performed, which explain an increase of the nanotubes produced in the magnetic field - enhanced arc discharge.