877 resultados para Analysis and digital image processing
Resumo:
Grinding process is usually the last finishing process of a precision component in the manufacturing industries. This process is utilized for manufacturing parts of different materials, so it demands results such as low roughness, dimensional and shape error control, optimum tool-life, with minimum cost and time. Damages on the parts are very expensive since the previous processes and the grinding itself are useless when the part is damaged in this stage. This work aims to investigate the efficiency of digital signal processing tools of acoustic emission signals in order to detect thermal damages in grinding process. To accomplish such a goal, an experimental work was carried out for 15 runs in a surface grinding machine operating with an aluminum oxide grinding wheel and ABNT 1045 e VC131 steels. The acoustic emission signals were acquired from a fixed sensor placed on the workpiece holder. A high sampling rate acquisition system at 2.5 MHz was used to collect the raw acoustic emission instead of root mean square value usually employed. In each test AE data was analyzed off-line, with results compared to inspection of each workpiece for burn and other metallurgical anomaly. A number of statistical signal processing tools have been evaluated.
Resumo:
Purpose: Spontaneous eye blink activity in the primary eye position and its relationship to age and gender were assessed using digital image processing techniques to quantify blink opening and closing time. Methods: One hundred-and-eighty healthy volunteers (90 males and 90 females), divided into the age groups 0-3, 4-12, 13-20, 21-40, 41-60 and ≥60 years old, were evaluated prospectively. They were videotaped digitally in a standard setting and the images were transferred to a personal computer (Macintosh 400) and processed with the iMovie software. Blink opening and closing time were measured at 30 frames/second. The data were then subjected to statistical analysis. Results: The closing time was significantly longer than the opening time for all ages and both genders. Elderly individuals (≥41 years old) and women had significantly longer closing times. Conclusion: Image processing techniques made possible the observation of differences in spontaneous eye blink opening and closing time in relation to age and gender. Copyright © 2005 Taylor & Francis LLC.
Resumo:
In this work an image pre-processing module has been developed to extract quantitative information from plantation images with various degrees of infestation. Four filters comprise this module: the first one acts on smoothness of the image, the second one removes image background enhancing plants leaves, the third filter removes isolated dots not removed by the previous filter, and the fourth one is used to highlight leaves' edges. At first the filters were tested with MATLAB, for a quick visual feedback of the filters' behavior. Then the filters were implemented in the C programming language. At last, the module as been coded in VHDL for the implementation on a Stratix II family FPGA. Tests were run and the results are shown in this paper. © 2008 Springer-Verlag Berlin Heidelberg.
Resumo:
The digital image processing has been applied in several areas, especially where it is necessary use tools for feature extraction and to get patterns of the studied images. In an initial stage, the segmentation is used to separate the image in parts that represents a interest object, that may be used in a specific study. There are several methods that intends to perform such task, but is difficult to find a method that can easily adapt to different type of images, that often are very complex or specific. To resolve this problem, this project aims to presents a adaptable segmentation method, that can be applied to different type of images, providing an better segmentation. The proposed method is based in a model of automatic multilevel thresholding and considers techniques of group histogram quantization, analysis of the histogram slope percentage and calculation of maximum entropy to define the threshold. The technique was applied to segment the cell core and potential rejection of tissue in myocardial images of biopsies from cardiac transplant. The results are significant in comparison with those provided by one of the best known segmentation methods available in the literature. © 2010 IEEE.
Resumo:
Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC95%:6.04-6.54) and 6.79 mm (IC95%:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm (IC95%:6.40-6.89) and 6.79mm(IC95%:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss. copy; 2012 by Korean Academy of Oral and Maxillofacial Radiology.
Resumo:
Surface defects are extremely important in mechanical characterization of several different materials. Therefore, the analysis of surface finishing is essential for a further simulation of surface mechanical properties in a customized project in materials science and technology. One of the methods commonly employed for such purpose is the statistical mapping of different sample surface regions using the depth from focus technique. The analysis is usually performed directly from the elevation maps which are obtained from the digital image processing. In this paper, the possibility of quantifying the surface heterogeneity of Silicon Carbide porous ceramics by elevation map histograms is presented. The advantage of this technique is that it allows the qualitative or quantitative verification of all surface image fields that cannot be done by using the Surface Plot plugin of image J™ platform commonly used in digital image processing. © 2012 Springer Science+Business Media, LLC.
Resumo:
This study examined the relationships between gross chemical composition and ultrasonographic characteristics of the ram testes. Ten testes from sexually mature Karakul rams were scanned ex situ with an 8-MHz linear-array transducer, in a transverse and longitudinal plane. All ultrasonograms were saved as digital images and subjected to computerized analyses. Crude protein content was determined by the Kjeldahl method, moisture was determined with an oven-drying method, and fat was measured by the Soxhlet extraction of dried samples. Mean pixel values (r = -0.64, P = 0.04), pixel heterogeneity (standard deviation of pixel values; r = -0.64, P = 0.04) and maximum pixel intensity (r = -0.76, P = 0.01) were all negatively correlated with parenchymal protein content. Pixel heterogeneity correlated directly with extractable lipids (r = 0.66, P = 0.02). The quantitative correlations between echotextural and biochemical parameters found in the present experiment confirm the utility of ultrasonographic imaging combined with computer-assisted image analysis for determining changes in testicular histophysiology. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJECTIVES: Despite the recent success regarding the transplantation of tissue-engineered airways, the mechanical properties of these grafts are not well understood. Mechanical assessment of a tissue-engineered airway graft before implantation may be used in the future as a predictor of function. The aim of this preliminary work was to develop a noninvasive image-processing environment for the assessment of airway mechanics.METHOD: Decellularized, recellularized and normal tracheas (groups DECEL, RECEL, and CONTROL, respectively) immersed in Krebs-Henseleit solution were ventilated by a small-animal ventilator connected to a Fleisch pneumotachograph and two pressure transducers (differential and gauge). A camera connected to a stereomicroscope captured images of the pulsation of the trachea before instillation of saline solution and after instillation of Krebs-Henseleit solution, followed by instillation with Krebs-Henseleit with methacholine 0.1 M (protocols A, K and KMCh, respectively). The data were post-processed with computer software and statistical comparisons between groups and protocols were performed.RESULTS: There were statistically significant variations in the image measurements of the medial region of the trachea between the groups (two-way analysis of variance [ANOVA], p<0.01) and of the proximal region between the groups and protocols (two-way ANOVA, p<0.01).CONCLUSIONS: The technique developed in this study is an innovative method for performing a mechanical assessment of engineered tracheal grafts that will enable evaluation of the viscoelastic properties of neo-tracheas prior to transplantation.
Resumo:
It has been demonstrated that, on abrupt withdrawal, patients with chronic exposure can experience a number of symptoms indicative of a dependent state. In clinical patients, the earliest to arise and most persistent signal of withdrawal from chronic benzodiazepine (Bzp) treatment is anxiety. In laboratory animals, anxiety-like effects following abrupt interruption of chronic Bzp treatment can also be reproduced. In fact, signs that oscillate from irritability to extreme fear behaviours and seizures have been described already. As anxiety remains one of the most important symptoms of Bzp withdrawal, in this study we evaluated the anxiety levels of rats withdrawn from diazepam. Also studied were the effects on the motor performance and preattentive sensory gating process of rats under diazepam chronic treatment and upon 48-h withdrawal on three animal models of anxiety, the elevated plus-maze (EPM), ultrasonic vocalizations (USV) and startle + prepulse inhibition tests. Data obtained showed an anxiolytic- and anxiogenic-like profile of the chronic intake of and withdrawal from diazepam regimen in the EPM test, 22-KHz USV and startle reflex. Diazepam chronic effects or its withdrawal were ineffective in promoting any alteration in the prepulse inhibition (PPI). However, an increase of PPI was achieved in both sucrose and diazepam pretreated rats on 48-h withdrawal, suggesting a procedural rather than a specific effect of withdrawal on sensory gating processes. It is also possible that the prepulse can function as a conditioned stimulus to informing the delivery of an aversive event, as the auditory startling-eliciting stimulus. All these findings are indicative of a sensitization of the neural substrates of aversion in diazepam withdrawn animals without concomitant changes on the processing of sensory information
Resumo:
Image segmentation is a process frequently used in several different areas including Cartography. Feature extraction is a very troublesome task, and successful results require more complex techniques and good quality data. The aims of this paper is to study Digital Image Processing techniques, with emphasis in Mathematical Morphology, to use Remote Sensing imagery, making image segmentation, using morphological operators, mainly the multi-scale morphological gradient operator. In the segmentation process, pre-processing operators of Mathematical Morphology were used, and the multi-scales gradient was implemented to create one of the images used as marker image. Orbital image of the Landsat satellite, sensor TM was used. The MATLAB software was used in the implementation of the routines. With the accomplishment of tests, the performance of the implemented operators was verified and carried through the analysis of the results. The extration of linear feature, using mathematical morphology techniques, can contribute in cartographic applications, as cartographic products updating. The comparison to the best result obtained was performed by means of the morphology with conventional techniques of features extraction. © Springer-Verlag 2004.
Resumo:
In this thesis two major topics inherent with medical ultrasound images are addressed: deconvolution and segmentation. In the first case a deconvolution algorithm is described allowing statistically consistent maximum a posteriori estimates of the tissue reflectivity to be restored. These estimates are proven to provide a reliable source of information for achieving an accurate characterization of biological tissues through the ultrasound echo. The second topic involves the definition of a semi automatic algorithm for myocardium segmentation in 2D echocardiographic images. The results show that the proposed method can reduce inter- and intra observer variability in myocardial contours delineation and is feasible and accurate even on clinical data.