852 resultados para Adesivo tecidual de fibrina


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effect of chlorhexidine (CHX) on the wettability of sound and caries affected dentin by a simplified adhesive system. Material and Methods: Flat coronal dentin surfaces were produced on 60 sound molars, 30 of which were artificially decayed. The teeth were divided randomly into 3 groups (n = 10) with smear layer (SL), without SL impregnated with water and without SL impregnated with chlorhexidine. The SL removal was performed by phosphoric acid etching for 15 s. 20 uL of distilled water or 2% chlorhexidine digluconate were applied on the demineralized dentin for 60 s. Then, a drop of Single Bond 2 was deposited on each surface. Contact angles between dentin surface and adhesive was measured by means of a goniometer and data were submitted to ANOVA and Tukey tests (α = 0.05). Results: Higher contact angles were obtained on sound versus caries affected dentin (p <0.05), regardeless of the surface treatment. For both substrates, contact angles statistically higher were obtained for dentin covered with SL (P <0.05). The SL removal resulted in significant reduction of the angles (P <0.05) and no difference was found among angles produced on demineralized dentin impregnated with water or chlorhexidine (p> 0.05). Conclusion: Caries affected dentin wettability was higher than sound dentin and that characteristic was not influenced by chlorhexidine application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this literature review is to present the state-of-the-art on the application of tissue engineering techniques in sinus lifts procedures, reporting the influence of these techniques in increasing bone height and volume in the maxillary sinus, and the osseointegration of the implants installed in the grafted areas. PubMed and Scopus databases were searched using the keywords “scaffold” OR “engineered tissue” AND “sinus augmention” OR “sinus floor elevation”. In the initial search 463 articles were selected, of which 19 were selected abstracts reading, with nine papers selected by the end, for evaluation of the application of tissue engineering techniques in sinus lift procedures. Despite the positive results of tissue engineering procedures in sinus floor elevation reported in the selected articles, further studies are still needed, for a better standardization of experimental models and materials used, leading to definitive conclusions about the effects of the application of tissue engineering procedures on bone formation in maxillary sinus lifting procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To quantify fibrin degradation products after topical and subconjunctival administration of recombinant tissue plasminogen activator in rabbits. Methods: Fibrin formation was induced in the anterior chamber in 25 rabbits. Subsequently, five rabbits received an injection of r-TPA (positive control) in the anterior chamber, another 10 received a subconjunctival injection of r-TPA, and the remaining 10 received instillations of topical r-TPA. Afterwards, samples of aqueous humor were collected and semi-quantitative analysis of fibrin degradation products (FDP) was performed. Results: No statistical differences were noted between the treatment and control groups at any time point. Fibrin degradation products semi-quantification showed statistical improvement in the control group and the subconjunctival group. Conclusion: Fibrin degradation products were observed in the anterior chamber after subconjunctival administration of r-TPA. However, it was probably not sufficient to cause fibrin degradation. Topical r-TPA did not effectively absorb anterior chamber fibrin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lipids have important biological functions, suchas membrane constituents, hormone precursors, and are efficient energy reserves, due to thers high caloric content. In fish, but not in mammals, lipid storage patterns are quite diverse. The aim of this study was to determine lipid distribution in somatic and reproductive tissues of matrinxã, Brycon cephalus, both male and female, highlighting somatic indices related to lipid dynamics. From Oct 98 to Jan 99, a total of 174 fish (8-12 each month) were sampled. After fish anesthesia, heparinized blood was collected for plasma triacylglycerol determination. Fish were individually weighed and measured, and liver, gonads and visceral fat were collected and weighed for HSI (hepatosomatic index), GSI (gonad somatic index) and MFI (mesenteric fat index) calculation. The highest values of total lipids were found in red muscle (about 18%), liver and gonads (about 16.5%). The white muscle had a lower concentration (2.5%). Analyses of variance of HSI and MFI showed fluctuations along the experimental period with lowest concentrations in the periods of highest temperatures. Matrinxã store lipids in several body tissues, including mesenteric fat, liver, muscles and gonads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The disadvantages generated by the acid etching of the dentin, such as an increase in its permeability, in the surface moisture and in the potential to denature the external dentinal collagen, the formation of a fragility zone and the citotoxicity of the adhesive monomers; which are all aggravated by the depth of the dentin, have stimulated new and different treatment philosophies of the dentin. The purpose of the present study, therefore, was to investigate the effects of three dentin treatments: laser irradiation, acid etching and hypermineralization, in the shear bond strength of the SMP Plus bonding system. Sixty bovine incisors were extracted and randomly selected immediatly alter the animal's death. They were kept frozen (-18°C) for no longer than 14 days. After buccal dentinal surface had been exposed, X-Rays were taken to control the dentin thickness. The specimens were separated into two groups: (1) Control, kept in distilled water at 4ºC; (2) Mineralized, kept in hypermineralized solution at 4°C for 14 days. Each group was divided into three sub-groups according to the type of dentin treatment used: group F - followed the manufacturer instructions (acid-etching + primer + bond), group AL (acid-etching + primer + bond + laser) and group LA (laser + (laser + acid-etching + primer + bond). A composite resin standard cylinder (Z100-3M) was bond to the dentinal surface and the shear bond strength performed on a Universal lnstron machine 4301, with 500 Kg load and at 0,5mm/min. speed. The analysis of variance (ANOVA) determined that the treatments influenced the shear bond strength values (p<0,05) with the following average shearing load at failure: AL (9,96 MPa), F (7,28MPa) e LA (4,87 MPa). The interaction between the two factors analyzed Group (control and mineralized) and treatment (F, AL, LA) also influenced the shear bond strength (p<0,05). The highest values were obtained...