168 resultados para Abrasão corneana


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The maintenance of Implant-supported Prosthesis is essential to the success of dental implants. Therefore, the aim of the study was to conduct a review the literature addressing maintenance Implant-Supported Prosthesis in order to guide planning for the longevity of oral rehabilitation. We conducted a detailed search strategy for the Pubmed / Medline Dentistry and Oral Science, used as descriptors: “Oral Hygiene“ and “Dental Implant until July, 2013. The results were grouped together in topics (Clinical Exam and Oral Hygiene) and discussed. Conclusion: A regular maintenance program for oral patient implantprosthesis is essential to the longevity of the treatment. Different methods and devices are effective for cleansing. However one orientation (in writing) must be offered to patients, since inadequate cleaning can create regions of abrasion on the surfaces of abutments and dental implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concepts of buccal health promotion and the increase of life expectancy have contributed for the highest maintenance of dental elements. Thus, with the new alimentary and behavioral habits the irreversible loss of dental hard tissue of non-carious origin has increased substantially, being divided in attrition, erosion and abrasion. The dental erosion is a chronic pathology defined as the superficial loss of dental hard tissue as a result of a chemical process not involving bacteria caused by acid that could be intrinsic, extrinsic or unknown etiology, causing irreversible loss of mineral tissue and dentinal hypersensitivity. The aim of this paper is to present a review of literature on the main factors that can cause the injuries of erosion, including the different aspects related to its etiology, classification, diagnosis, prevention and treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Machining is one of the most commonly manufacturing processes used in the modern world, consuming millions of dollars annually. Because of this, it is crucial for the automotive industry to reduce costs on their heat-resistant alloy machining processes, such as compacted graphite iron (CGI), which has shown an increasing trend of its application in diesel engine blocks, brakes disks, among other applications, due to its superior mechanical properties to gray cast iron. Despite this advantage, its use is still limited due to its difficulty of machining, moreover, cutting tools are displayed as the main factor in increasing the machining cost. Seeking an alternative to a better machinability of CGI, this paper aims to study two types of ceramic tools developed in Brazil, and benchmark their performance by dry turning. For this, were used CGI class 450 and two tools: ceramic of silicon nitride (Si3N4) and alumina-based (Al2O3), with a cutting speed (Vc) of 300, 400 and 500 m / min; feed (f) of 0.2 mm / rev and depth of cut (ap) of 0.5 mm, using three replicates and starting with new cutting edges. The results showed that the Al2O3 tool had the best performance in Vc of 500 m / min, while the Si3N4 tool had the best results in Vc of 300 m / min. This can be explained by the tool of Si3N4 based include soft intergranular phase, called amorphous, while alumina has higher abrasion resistance due to its high refractoriness. The results make it clear that the tools have significant potential for machining of compacted graphite iron, being necessary a strict control of the cutting parameters used

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Machining is one of the most commonly manufacturing processes used in the modern world, consuming millions of dollars annually. Because of this, it is crucial for the automotive industry to reduce costs on their heat-resistant alloy machining processes, such as compacted graphite iron (CGI), which has shown an increasing trend of its application in diesel engine blocks, brakes disks, among other applications, due to its superior mechanical properties to gray cast iron. Despite this advantage, its use is still limited due to its difficulty of machining, moreover, cutting tools are displayed as the main factor in increasing the machining cost. Seeking an alternative to a better machinability of CGI, this paper aims to study two types of ceramic tools developed in Brazil, and benchmark their performance by dry turning. For this, were used CGI class 450 and two tools: ceramic of silicon nitride (Si3N4) and alumina-based (Al2O3), with a cutting speed (Vc) of 300, 400 and 500 m / min; feed (f) of 0.2 mm / rev and depth of cut (ap) of 0.5 mm, using three replicates and starting with new cutting edges. The results showed that the Al2O3 tool had the best performance in Vc of 500 m / min, while the Si3N4 tool had the best results in Vc of 300 m / min. This can be explained by the tool of Si3N4 based include soft intergranular phase, called amorphous, while alumina has higher abrasion resistance due to its high refractoriness. The results make it clear that the tools have significant potential for machining of compacted graphite iron, being necessary a strict control of the cutting parameters used

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This in vitro study analysed the effect of different fluoride concentrations in acidic or neutral liquid dentifrices in protecting enamel and dentine from erosive and abrasive wear. Methods: Bovine enamel and dentine specimens (n = 132) were randomly allocated to 11 groups (each n = 12): experimental liquid dentifrices with 550 ppm F, 1100 ppm F, 5000 ppm F or 0 ppm F/placebo (each at pH 4.5 and pH 7.0); and commercial dentifrices with 550 ppm F (Colgate Baby, pH 7.0), 1100 ppm F (Crest, pH 7.0) and 5000 ppm F (Duraphat, pH 7.0). The specimens were subjected to erosion for 90 seconds, 4 times/day, over 7 days. Immediately after the first and last erosion, the specimens were brushed for 15 seconds using one of the dentifrices. Tooth wear was measured profilometrically (lm) and analysed by ANOVA (p < 0.05). Results: All fluoridated liquid dentifrices significantly reduced enamel wear compared to the placebo and commercial dentifrices. Only liquid dentifrices with 1100 and 5000 ppm F significantly reduced dentine wear compared to placebo dentifrice. The pH had no effect, but the consistency had a significant impact on the effect of dentifrices. Conclusions: Liquid dentifrices with high F concentration appear to be a good option to prevent tooth wear

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the in vitro changes on the enamel surface after a micro-abrasion treatment promoted by different products. Material and Methods: Fifty (50) fragments of bovine enamel (15 mm × 5 mm) were randomly assigned to five groups (n=10) according to the product utilized: G1 (control)= silicone polisher (TDV), G2= 37% phosphoric acid (3M/ESPE) + pumice stone (SS White), G3= Micropol (DMC Equipment), G4= Opalustre (Ultradent) and G5= Whiteness RM (FGM Dental Products). Roughness and wear were the responsible variables used to analyze these surfaces in four stages: baseline, 60 s and 120 s after the micro-abrasion and after polishing, using a Hommel Tester T1000 device. After the tests, a normal distribution of data was verified, with repeated ANOVA analyses (p?0.05) which were used to compare each product in different stages. One-way ANOVA and Tukey tests were applied for individual comparisons between the products in each stage (p?0.05). Results: Means and standard deviations of roughness and wear (µm) after all the promoted stages were: G1=7.26(1.81)/13.16(2.67), G2=2.02(0.62)/37.44(3.33), G3=1.81(0.91)/34.93(6.92), G4=1.92(0.29)/38.42(0.65) and G5=1.98(0.53)/33.45(2.66). At 60 seconds, all products tended to produce less surface roughness with a variable gradual decrease over time. After polishing, there were no statistically significant differences between the groups, except for G1. Independent of the product utilized, the enamel wear occurred after the micro-abrasion. Conclusions: In this in vitro study, enamel micro-abrasion presented itself as a conservative approach, regardless of the type of the paste compound utilized. These products promoted minor roughness alterations and minimal wear. The use of phosphoric acid and pumice stone showed similar results to commercial products for the micro-abrasion with regard to the surface roughness and wear.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemical abrasion was carried out on zircons grains of the Temora II standard for U-Pb dating prior to analyses using in situ Laser Ablation-MultiCollector Ion Coupled Plasma Mass Spectrometer (LA-ICPMS) followed by the Isotope Dissolution Thermal Ionization Mass Spectrometer (ID-TIMS) method. The proposed methodology was herein applied in order to reduce primarily the effects of secondary Pb loss, the presence of common lead and/or silicate impurities. Nine Temora II zircon grains were analyzed by the laser ablation method yielding an age of 418.3±4.3 Ma. Zircon grains of a same population were separated for chemical abrasion before dissolution and mass spectrometry analyses. Six fractions of them were separated for isotope dissolution using 235U-205Pb mixed spike after we have checked and assured the laboratory conditions of low blank values for total Pb of less than 2 pg/g. The obtained U-Pb zircon age by the ID-TIMS method was 415.7±1.8 Ma (error 0.43 %) based on four successful determinations. The results are consistent with the published ages for the Temora diorite (Temora I â 416.75±1.3 Ma; Temora II â 416.78±0.33 Ma) and established as 416±0.33 Ma. The technique is thus recommended for high precision U-Pb zircon analyses (error < 1 %), mainly for high resolution stratigraphic studies of Phanerozoic sequences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Utilização da metodologia para interpretação da tomografia de córnea e segmento anterior para a detecção e diagnóstico de ectasia corneana. MÉTODOS: Descrição da interpretação clínica dos índices da tomografia de córnea e segmento anterior (Pentacam High Resolution - Oculus, Wetzlar,Germany); relato de 3 casos, demonstrando a importância da propedêutica no exame complementar, através do Pentacam HR®. CONCLUSÃO: Nossa experiência compatibiliza-se com os relatos de literatura na demonstração do incremento de sensibilidade e especificidade para a detecção precoce de susceptibilidade e diagnóstico de ectasia corneana, utilizando a tomografia de córnea e segmento anterior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Placas de granitos são amplamente empregadas no revestimento de pisos na forma de ladrilhos assentados com argamassa industrializada. Recentemente, tem crescido o interesse no uso de sistemas não aderentes (sem argamassa) com placas de rocha. Porém, na literatura muito pouco foi publicado a respeito. O presente trabalho avaliou as propriedades físico-mecânicas de três granitos com grande aceitação comercial, e determinou as espessuras necessárias para estas das placas serem usadas como lajes de 200 cm de largura por 300 cm de comprimento, apoiadas pelas quatro extremidades em vigas de concreto. As propriedades testadas para o projeto estrutural das placas de granito foram: resistência à compressão, resistência à flexão por três pontos, módulo de elasticidade e coeficiente de Poisson. Foram também determinados o coeficiente de atrito e a resistência à abrasão profunda para a avaliação do desempenho do piso, de acordo com o uso e o ambiente de exposição,. Os resultados indicaram que o charnockito Verde Labrador deve ser usado com espessura de 30 mm, restrita a ambientes internos. O sienogranito e o monzogranito podem ser empregados em ambientes internos e externos. As placas do monzogranito Cinza Castelo devem possuir espessura de 20 mm, e as do sienogranito Vermelho Brasília devem possuir 30 mm de espessura.