945 resultados para ANGLE-RESOLVED ELLIPSOMETRY
Resumo:
In this study we propose an evaluation of the angular effects altering the spectral response of the land-cover over multi-angle remote sensing image acquisitions. The shift in the statistical distribution of the pixels observed in an in-track sequence of WorldView-2 images is analyzed by means of a kernel-based measure of distance between probability distributions. Afterwards, the portability of supervised classifiers across the sequence is investigated by looking at the evolution of the classification accuracy with respect to the changing observation angle. In this context, the efficiency of various physically and statistically based preprocessing methods in obtaining angle-invariant data spaces is compared and possible synergies are discussed.
Resumo:
Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.
Resumo:
Abstract
Resumo:
PURPOSE: At high magnetic field strengths (B0 ≥ 3 T), the shorter radiofrequency wavelength produces an inhomogeneous distribution of the transmit magnetic field. This can lead to variable contrast across the brain which is particularly pronounced in T2 -weighted imaging that requires multiple radiofrequency pulses. To obtain T2 -weighted images with uniform contrast throughout the whole brain at 7 T, short (2-3 ms) 3D tailored radiofrequency pulses (kT -points) were integrated into a 3D variable flip angle turbo spin echo sequence. METHODS: The excitation and refocusing "hard" pulses of a variable flip angle turbo spin echo sequence were replaced with kT -point pulses. Spatially resolved extended phase graph simulations and in vivo acquisitions at 7 T, utilizing both single channel and parallel-transmit systems, were used to test different kT -point configurations. RESULTS: Simulations indicated that an extended optimized k-space trajectory ensured a more homogeneous signal throughout images. In vivo experiments showed that high quality T2 -weighted brain images with uniform signal and contrast were obtained at 7 T by using the proposed methodology. CONCLUSION: This work demonstrates that T2 -weighted images devoid of artifacts resulting from B1 (+) inhomogeneity can be obtained at high field through the optimization of extended kT -point pulses. Magn Reson Med 71:1478-1488, 2014. © 2013 Wiley Periodicals, Inc.
Resumo:
Time-resolved measurements of tissue autofluorescence (AF) excited at 405 nm were carried out with an optical-fiber-based spectrometer in the bronchi of 11 patients. The objectives consisted of assessing the lifetime as a new tumor/normal (T/N) tissue contrast parameter and trying to explain the origin of the contrasts observed when using AF-based cancer detection imaging systems. No significant change in the AF lifetimes was found. AF bronchoscopy performed in parallel with an imaging device revealed both intensity and spectral contrasts. Our results suggest that the spectral contrast might be due to an enhanced blood concentration just below the epithelial layers of the lesion. The intensity contrast probably results from the thickening of the epithelium in the lesions. The absence of T/N lifetime contrast indicates that the quenching is not at the origin of the fluorescence intensity and spectral contrasts. These lifetimes (6.9 ns, 2.0 ns, and 0.2 ns) were consistent for all the examined sites. The fact that these lifetimes are the same for different emission domains ranging between 430 and 680 nm indicates that there is probably only one dominant fluorophore involved. The measured lifetimes suggest that this fluorophore is elastin.
Resumo:
In cases of transjugular liver biopsies, the venous angle formed between the chosen hepatic vein and the vena cava main axis in a frontal plane can be large, leading to technical difficulties. In a prospective study including 139 consecutive patients who underwent transjugular liver biopsy using the Quick-Core biopsy set, the mean venous angle was equal to 49.6 degrees. For 21.1% of the patients, two attempts at hepatic venous catheterization failed because the venous angle was too large, with a mean of 69.7 degrees. In all of these patients, manual reshaping of the distal curvature of the stiffening metallic cannula, by forming a new mean angle equal to 48 degrees , allowed successful completion of the procedure in less than 10 min.
Resumo:
BACKGROUND: Selective laser trabeculoplasty (SLT) is a relatively new treatment strategy for the treatment of glaucoma. Its principle is similar to that of argon laser trabeculoplasty (ALT), but may lead to less damage to the trabecular meshwork. METHODS: We assessed the 2-year efficacy of SLT in a noncomparative consecutive case series. Any adult patient either suspected of having glaucoma or with open-angle glaucoma, whose treatment was judged insufficient to reach target intraocular pressure (IOP), could be recruited. IOP and number of glaucoma treatments were recorded over 2 years after the procedure. RESULTS: Our sample consisted of 44 consecutive eyes of 26 patients, aged 69+/-8 years. Eyes were treated initially on the lower 180 degrees . Three of them were retreated after 15 days on the upper 180. Fourteen eyes had ocular hypertension, 17 primary open-angle/normal-tension glaucoma, 11 pseudoexfoliation (PEX) glaucoma, and two pigmentary glaucoma. Thirty-six eyes had previously been treated and continued to be treated with topical anti-glaucoma medication, ten had had prior ALT, nine iridotomy, and 12 filtering surgery. The 2-year-follow up could not be completed for eight eyes because they needed filtering surgery. In the remaining 36 eyes, IOP decreased by a mean of 17.2%, 3.3 mmHg, (19.2+/-4.7 to 15+/-3.6 mmHg) after 2 years (p<0.001). As a secondary outcome, the number of glaucoma treatments decreased from 1.44 to 1.36 drops/patient. Other results according to subgroups of patients are analyzed: the greatest IOP decrease occurred in eyes that had never been treated with anti-glaucoma medication or with PEX glaucoma. SLT was probably valuable in a few eyes after filtering surgery; however, the statistical power of the study was not strong enough to draw a firm conclusion. When expressed in survival curves after 2 years, however, only 48% and 41% of eyes experienced a decrease of more than 3 mmHg or more than 20% of preoperative intraocular pressure, respectively. CONCLUSION: SLT decreases IOP somewhat for at least 2 years without an increase in topical glaucoma treatment. However, it cannot totally replace topical glaucoma treatment. In the future, patient selection should be improved to decrease the cost/effectiveness ratio.
Resumo:
The two independent components of the gyration tensor of quartz, g11 and g33, have been spectroscopically measured using a transmission two-modulator generalized ellipsometer. The method is used to determine the optical activity in crystals in directions other than the optic axis, where the linear birefringence is much larger than the optical activity.
Resumo:
The eccentric contraction mode was proposed to be the primary stimulus for optimum angle (angle at which peak torque occurs) shift. However, the training range of motion (or muscle excursion range) could be a stimulus as important. The aim of this study was to assess the influence of the training range of motion stimulus on the hamstring optimum length. It was hypothesised that performing a single set of concentric contractions beyond optimal length (seated at 80° of hip flexion) would lead to an immediate shift of the optimum angle to longer muscle length while performing it below (supine at 0° of hip flexion) would not provide any shift. Eleven male participants were assessed on an isokinetic dynamometer. In both positions, the test consisted of 30 consecutive knee flexions at 4.19 rad · s⁻¹. The optimum angle was significantly shifted by ∼15° in the direction of longer muscle length after the contractions at 80° of hip flexion, while a non-significant shift of 3° was found at 0°. The hamstring fatigability was not influenced by the hip position. It was concluded that the training range of motion seems to be a relevant stimulus for shifting the optimum angle to longer muscle length. Moreover, fatigue appears as a mechanism partly responsible for the observed shift.
Resumo:
Nous avons analysé l'angle naso-labial et les différents facteurs qui l'influencent, chez des patients de 9 ans ± 1,4. Nous avons obten u une valeur moyenne de 115,30 ± 10,8. L'inclinaison et la position de l'incisive supérieure et l'angle ANB constituent les facteurs osseux et dentaires qui ont la plus grande répercussion sur l'angle naso-labial. Le sexe et l'age n'ont pas eu d'influences statistiquement significatives sur les résultats. L'incompétence labiale s'est avérée etre la cause d'un angle plus aigu
Resumo:
Nous avons analysé l'angle naso-labial et les différents facteurs qui l'influencent, chez des patients de 9 ans ± 1,4. Nous avons obten u une valeur moyenne de 115,30 ± 10,8. L'inclinaison et la position de l'incisive supérieure et l'angle ANB constituent les facteurs osseux et dentaires qui ont la plus grande répercussion sur l'angle naso-labial. Le sexe et l'age n'ont pas eu d'influences statistiquement significatives sur les résultats. L'incompétence labiale s'est avérée etre la cause d'un angle plus aigu