885 resultados para 3D acquisitions registration
Resumo:
Background: Surgical repair of pectus excavatum (PE) has become more popular due to improvements in the minimally invasive Nuss procedure. The pre-surgical assessment of PE patients requires Computerized Tomography (CT), as the malformation characteristics vary from patient to patient. Objective: This work aims to characterize soft tissue thickness (STT) external to the ribs among PE patients. It also presents a comparative analysis between the anterior chest wall surface before and after surgical correction. Methods: Through surrounding tissue segmentation in CT data, STT values were calculated at different lines along the thoracic wall, with a reference point in the intersection of coronal and median planes. The comparative analysis between the two 3D anterior chest surfaces sets a surgical correction influence area (SCIA) and a volume of interest (VOI) based on image processing algorithms, 3D surface algorithms, and registration methods. Results: There are always variations between left and right side STTs (2.54±2.05 mm and 2.95±2.97 mm for female and male patients, respectively). STTs are dependent on age, sex, and body mass index of each patient. On female patients, breast tissue induces additional errors in bar manual
Resumo:
Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor.
Resumo:
This paper presents Palco, a prototype system specifically designed for the production of 3D cartoon animations. The system addresses the specific problems of producing cartoon animations, where the main obj ective is not to reproduce realistic movements, but rather animate cartoon characters with predefined and characteristic body movements and facial expressions. The techniques employed in Palco are simple and easy to use, not requiring any invasive or complicated motion capture system, as both body motion and facial expression of actors are captured simultaneously, using an infrared motion detection sensor, a regular camera and a pair of electronically instrumented gloves. The animation process is completely actor-driven, with the actor controlling the character movements, gestures, facial expression and voice, all in realtime. The actor controlled cartoonification of the captured facial and body motion is a key functionality of Palco, and one that makes it specifically suited for the production of cartoon animations.
Resumo:
The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.
Resumo:
One of the current frontiers in the clinical management of Pectus Excavatum (PE) patients is the prediction of the surgical outcome prior to the intervention. This can be done through computerized simulation of the Nuss procedure, which requires an anatomically correct representation of the costal cartilage. To this end, we take advantage of the costal cartilage tubular structure to detect it through multi-scale vesselness filtering. This information is then used in an interactive 2D initialization procedure which uses anatomical maximum intensity projections of 3D vesselness feature images to efficiently initialize the 3D segmentation process. We identify the cartilage tissue centerlines in these projected 2D images using a livewire approach. We finally refine the 3D cartilage surface through region-based sparse field level-sets. We have tested the proposed algorithm in 6 noncontrast CT datasets from PE patients. A good segmentation performance was found against reference manual contouring, with an average Dice coefficient of 0.75±0.04 and an average mean surface distance of 1.69±0.30mm. The proposed method requires roughly 1 minute for the interactive initialization step, which can positively contribute to an extended use of this tool in clinical practice, since current manual delineation of the costal cartilage can take up to an hour.
Resumo:
Introduction and Objectives. Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons’ performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Materials and Methods. Each participant performed 3 laparoscopic tasks—Peg transfer, Wire chaser, Knot—in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Results. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). Conclusion. The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures.
Resumo:
We investigate shareholder value creation of Spanish listed firms in response to announcements of acquisitions of unlisted companies and compare this experience to the purchase of listed firms over the period 1991–2006. Similar to foreign markets, acquirers of listed targets earn insignificant average abnormal returns, whereas acquirers of unlisted targets gain significant positive average abnormal returns. When we relate these results to company and transaction characteristics our findings diverge from those reported in the literature for other foreign markets, as our evidence suggests that the listing status effect is mainly associated with the fact that unlisted firms tend to be smaller and lesser–known firms, and thus suffer from a lack of competition in the market for corporate control. Consequently, the payment of lower premiums and the possibility of diversifying shareholders’ portfolios lead to unlisted firm acquisitions being viewed as value–orientated transactions.
Resumo:
Introduction: The present paper deals with the issue of the increasing usage of corporation mergers and acquisitions strategies within pharmaceutical industry environment. The aim is to identify the triggers of such business phenomenon and the immediate impact on the financial outcome of two powerful biopharmaceutical corporations: Pfizer and GlaxoSmithKline, which have been sampled due to their successful approach of the tactics in question. Materials and Methods: In order to create an overview of the development steps through mergers and acquisitions, the historical data of the two corporations has been consulted, from their official websites. The most relevant events were then associated with adequate information from the financial reports and statements of the two corporations indulged by web-based financial data providers. Results and Discussions: In the past few decades Pfizer and GlaxoSmithKline have purchased or merged with various companies in order to monopolize new markets, diversify products and services portfolios, survive and surpass competitors. The consequences proved to be positive although this approach implies certain capital availability. Conclusions: Results reveal the fact that, as far as the two sampled companies are concerned, acquisitions and mergers are reactions at the pressure of the highly competitive environment. Moreover, the continuous diversification of the market’s needs is also a consistent motive. However, the prevalence and the eminence of mergers and acquisition strategies are conditioned by the tender offer, the announcer’s caliber, research and development status and further other factors determined by the internal and external actors of the market.
Resumo:
Mestrado em Medicina Nuclear - Área de especialização: Tomografia por Emissão de Positrões.
Resumo:
Mestrado em Engenharia Informática. Sistemas Gráficos e Multimédia.
Resumo:
Web tornou-se uma ferramenta indispensável para a sociedade moderna. A capacidade de aceder a enormes quantidades de informação, disponível em praticamente todo o mundo, é uma grande vantagem para as nossas vidas. No entanto, a quantidade avassaladora de informação disponível torna-se um problema, que é o de encontrar a informação que precisamos no meio de muita informação irrelevante. Para nos ajudar nesta tarefa, foram criados poderosos motores de pesquisa online, que esquadrinham a Web à procura dos melhores resultados, segundo os seus critérios, para os dados que precisamos. Actualmente, os motores de pesquisa em voga, usam um formato de apresentação de resultados simples, que consiste apenas numa caixa de texto para o utilizador inserir as palavras-chave sobre o tema que quer pesquisar e os resultados são dispostos sobre uma lista de hiperligações ordenada pela relevância que o motor atribui a cada resultado. Porém, existem outras formas de apresentar resultados. Uma das alternativas é apresentar os resultados sobre interfaces em 3 dimensões. É nestes tipos de sistemas que este trabalho vai incidir, os motores de pesquisa com interfaces em 3 dimensões. O problema é que as páginas Web não estão preparadas para serem consumidas por este tipo de motores de pesquisa. Para resolver este problema foi construído um modelo generalista para páginas Web, que consegue alimentar os requisitos das diversas variantes destes motores de pesquisa. Foi também desenvolvido um protótipo de instanciação automático, que recolhe as informações necessárias das páginas Web e preenche o modelo.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
Ainda antes da invenção da escrita, o desenho foi utilizado para descrever a realidade, tendo evoluído ao longo dos tempos, ganhando mais qualidade e pormenor e recorrendo a suportes cada vez mais evoluídos que permitissem a perpetuação dessa imagem: dessa informação. Desde as pinturas rupestres, nas paredes de grutas paleolíticas, passando pelos hieróglifos, nos templos egípcios, nas gravuras das escrituras antigas e nos quadros sobre tela, a intenção sempre foi a de transmitir a informação da forma mais directa e perceptível por qualquer indivíduo. Nos dias de hoje as novas tecnologias permitem aceder à informação com uma facilidade nunca antes vista ou imaginada, estando certamente ainda por descobrir outras formas de registar e perpetuar a informação para as gerações vindouras. A fotografia está na origem das grandes evoluções da imagem, permitindo capturar o momento, tornando-o “eterno”. Hoje em dia, na era da imagem digital, além de se mostrar a realidade, é possível incorporar na imagem informação adicional, de modo a enriquecer a experiência de visualização e a maximizar a aquisição do conhecimento. As possibilidades da visualização em três dimensões (3D) vieram dar o realismo que faltava ao formato de fotografia original. O 3D permite a imersão do espectador no ambiente que, a própria imagem retrata, à qual se pode ainda adicionar informação escrita ou até sensorial como, por exemplo, o som. Esta imersão num ambiente tridimensional permite ao utilizador interagir com a própria imagem através da navegação e exploração de detalhes, usando ferramentas como o zoom ou ligações incorporados na imagem. A internet é o local onde, hoje em dia, já se disponibilizam estes ambientes imersivos, tornando esta experiência muita mais acessível a qualquer pessoa. Há poucos anos ainda, esta prática só era possível mediante o recurso a dispositivos especificamente construídos para o efeito e que, por isso, apenas estavam disponíveis a grupos restritos de utilizadores. Esta dissertação visa identificar as características de um ambiente 3D imersivo e as técnicas existentes e possíveis de serem usadas para maximizar a experiência de visualização. Apresentar-se-ão algumas aplicações destes ambientes e sua utilidade no nosso dia-a-dia, antevendo as tendências futuras de evolução nesta área. Serão apresentados exemplos de ferramentas para a composição e produção destes ambientes e serão construídos alguns modelos ilustrativos destas técnicas, como forma de avaliar o esforço de desenvolvimento e o resultado obtido, comparativamente com formas mais convencionais de transmitir e armazenar a informação. Para uma avaliação mais objectiva, submeteram-se os modelos produzidos à apreciação de diversos utilizadores, a partir da qual foram elaboradas as conclusões finais deste trabalho relativamente às potencialidades de utilização de ambientes 3D imersivos e suas mais diversas aplicações.
Resumo:
Introdução – A análise da forma ou morfometria de estruturas anatómicas, como o trato vocal, pode ser efetuada a partir de imagens bidimensionais (2D) como de aquisições volumétricas (3D) de ressonância magnética (RM). Esta técnica de imagem tem vindo a ter uma utilização crescente no estudo da produção da fala. Objetivos – Demonstrar como pode ser efetuada a morfometria do trato vocal a partir da imagem por ressonância magnética e ainda apresentar padrões anatómicos normais durante a produção das vogais [i a u] e dois padrões articulatórios patológicos em contexto simulado. Métodos – As imagens consideradas foram recolhidas a partir de aquisições 2D (Turbo Spin-eco) e 3D (Flash Gradiente-Eco) de RM em quatro sujeitos durante a produção das vogais em estudo; adicionalmente procedeu-se à avaliação de duas perturbações articulatórias usando o mesmo protocolo de RM. A morfometria do trato vocal foi extraída com recurso a técnicas manuais (para extração de cinco medidas articulatórias) e automáticas (para determinação de volumes) de processamento e análise de imagem. Resultados – Foi possível analisar todo o trato vocal, incluindo a posição e a forma dos articuladores, tendo por base cinco medidas descritivas do posicionamento destes órgãos durante a produção das vogais. A determinação destas medições permitiu identificar quais as estratégias mais comummente adotadas na produção de cada som, nomeadamente a postura articulatória e a variação de cada medida para cada um dos sujeitos em estudo. No contexto de voz falada intersujeitos, foi notória a variabilidade nos volumes estimados do trato vocal para cada som e, em especial, o aumento do volume do trato vocal na perturbação articulatória de sigmatismo. Conclusão – A imagem por RM é, sem dúvida, uma técnica promissora no estudo da fala, inócua, não-invasiva e que fornece informação fiável da morfometria do trato vocal.