981 resultados para 320301 Clinical Chemistry


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Pregnancy toxaemia (PT) is a disease that affects pregnant goats during their last month of gestation and is characterized by a high case fatality rate. This study involved 32 does maintained on a commercial dairy goat farm that were diagnosed with PT. A physical examination was performed on and haematology parameters obtained from each doe, at the time of diagnosis. The data from the 24 PT goats that died was compared with the corresponding data from the 8 PT goats that survived. Results Polypnea, swollen limbs, anorexia with absence of ruminal motility, recumbency, nervous signs and drooping ears were the most frequently observed clinical manifestations. Nineteen out of 21 recumbent goats died. Sixteen out of 17 goats with anorexia and absence of ruminal motility died. Mean beta-hydroxybutyric acid (BHBA) values in the goats that died were not significantly different from those in goats that survived. The blood values for pH and pCO2 (p < 0.005) as well as for HCO3 −, BE and K+ (p < 0.001) were significantly lower in the goats that died than in those that survived. Conclusions The clinical signs most indicative of a poor prognosis are anorexia with absence of ruminal motility and recumbency. Among the blood parameters to be considered, hypokalaemia and metabolic acidosis are the most relevant. Goats with PT have a high mortality and their condition can deteriorate very fast. Based on the authors’s experience, a good strategy to minimize the economic losses caused by PT is to focus on the offspring survival rate since an early decision (induction of kidding or caesarian surgery) can increase the number of alive kids.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design. A sheep study designed to compare the accuracy of static radiographs, dynamic radiographs, and computed tomographic (CT) scans for the assessment of thoracolumbar facet joint fusion as determined by micro-CT scanning. Objective. To determine the accuracy and reliability of conventional imaging techniques in identifying the status of thoracolumbar (T13-L1) facet joint fusion in a sheep model. Summary of Background Data. Plain radiographs are commonly used to determine the integrity of surgical arthrodesis of the thoracolumbar spine. Many previous studies of fusion success have relied solely on postoperative assessment of plain radiographs, a technique lacking sensitivity for pseudarthrosis. CT may be a more reliable technique, but is less well characterized. Methods. Eleven adult sheep were randomized to either attempted arthrodesis using autogenous bone graft and internal fixation (n = 3) or intentional pseudarthrosis (IP) using oxidized cellulose and internal fixation (n = 8). After 6 months, facet joint fusion was assessed by independent observers, using (1) plain static radiography alone, (2) additional dynamic radiographs, and (3) additional reconstructed spiral CT imaging. These assessments were correlated with high-resolution micro-CT imaging to predict the utility of the conventional imaging techniques in the estimation of fusion success. Results. The capacity of plain radiography alone to correctly predict fusion or pseudarthrosis was 43% and was not improved using plain radiography and dynamic radiography with also a 43% accuracy. Adding assessment by reformatted CT imaging to the plain radiography techniques increased the capacity to predict fusion outcome to 86% correctly. The sensitivity, specificity, and accuracy of static radiography were 0.33, 0.55, and 0.43, respectively, those of dynamic radiography were 0.46, 0.40, and 0.43, respectively, and those of radiography plus CT were 0.88, 0.85, and 0.86, respectively. Conclusion. CT-based evaluation correlated most closely with high-resolution micro-CT imaging. Neither plain static nor dynamic radiographs were able to predict fusion outcome accurately. © 2012 Lippincott Williams & Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Screening tests of basic cognitive status or ‘mental state’ have been shown to predict mortality and functional outcomes in adults. This study examined the relationship between mental state and outcomes in children with type 1 diabetes. Objective We aimed to determine whether mental state at diagnosis predicts longer term cognitive function of children with a new diagnosis of type 1 diabetes. Methods Mental state of 87 patients presenting with newly diagnosed type 1 diabetes was assessed using the School-Years Screening Test for the Evaluation of Mental Status. Cognitive abilities were assessed 1 wk and 6 months postdiagnosis using standardized tests of attention, memory, and intelligence. Results Thirty-seven children (42.5%) had reduced mental state at diagnosis. Children with impaired mental state had poorer attention and memory in the week following diagnosis, and, after controlling for possible confounding factors, significantly lower IQ at 6 months compared to those with unimpaired mental state (p < 0.05). Conclusions Cognition is impaired acutely in a significant number of children presenting with newly diagnosed type 1 diabetes. Mental state screening is an effective method of identifying children at risk of ongoing cognitive difficulties in the days and months following diagnosis. Clinicians may consider mental state screening for all newly diagnosed diabetic children to identify those at risk of cognitive sequelae.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: This paper describes the development of a risk adjustment (RA) model predictive of individual lesion treatment failure in percutaneous coronary interventions (PCI) for use in a quality monitoring and improvement program. Methods and results: Prospectively collected data for 3972 consecutive revascularisation procedures (5601 lesions) performed between January 2003 and September 2011 were studied. Data on procedures to September 2009 (n = 3100) were used to identify factors predictive of lesion treatment failure. Factors identified included lesion risk class (p < 0.001), occlusion type (p < 0.001), patient age (p = 0.001), vessel system (p < 0.04), vessel diameter (p < 0.001), unstable angina (p = 0.003) and presence of major cardiac risk factors (p = 0.01). A Bayesian RA model was built using these factors with predictive performance of the model tested on the remaining procedures (area under the receiver operating curve: 0.765, Hosmer–Lemeshow p value: 0.11). Cumulative sum, exponentially weighted moving average and funnel plots were constructed using the RA model and subjectively evaluated. Conclusion: A RA model was developed and applied to SPC monitoring for lesion failure in a PCI database. If linked to appropriate quality improvement governance response protocols, SPC using this RA tool might improve quality control and risk management by identifying variation in performance based on a comparison of observed and expected outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Achieving soft tissue balance is an operative goal in total knee arthroplasty. This randomised, prospective study compared computer navigation to conventional techniques in achieving soft tissue balance. Methods: Forty one consecutive knee arthroplasties were randomised to either a non-navigated or navigated group. In the non-navigated group, balancing was carried out using surgeon judgement. In the navigated group, balancing was carried out using navigation software. In both groups, the navigation software was used as a measuring tool. Results: Balancing of the mediolateral extension gap was superior in the navigation group (p=0.001). No significant difference was found between the two groups in balancing the mediolateral flexion gap or in achieving equal flexion and extension gaps. Conclusions: Computer navigation offered little advantage over experienced surgeon judgement in achieving soft tissue balance in knee replacement. However, the method employed in the navigated group did provide a reproducible and objective assessment of flexion and extension gaps and may therefore benefit surgeons in training.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: Zhi Zhu Wan (ZZW) is a classical Chinese medical formulation used for the treatment of functional dyspepsia that attributed to Spleen-deficiency Syndrome. ZZW contains Atractylodes Rhizome and Fructus Citrus Immaturus, the later originates from both Citrus aurantium L. (BZZW) and Citrus sinensis Osbeck (RZZW). The present study is designed to elucidate disparities in the clinical efficacy of two ZZW varieties based on the pharmacokinetics of naringenin and hesperetin. MEHTOD: After oral administration of ZZWs, blood sample was collected from healthy volunteers at designed time points. Naringenin and hesperetin were detected in plasma by RP-HPLC, pharmacokinetic parameters were processed using mode-independent methods with WINNONLIN. RESULTS: After oral administration of BZZW, both naringenin and hesperetin were detected in plasma, and demonstrated similar pharmacokinetic parameters. Ka was 0.384+/-0.165 and 0.401+/-0.159, T(1/2(ke))(h) was 5.491+/-3.926 and 5.824+/-3.067, the AUC (mg/Lh) was 34.886+/-22.199 and 39.407+/-19.535 for naringenin and hesperetin, respectively. However, in the case of RZZW, only hesperetin was found in plasma, but the pharmacokinetic properties for hesperetin in RZZW was different from that in BZZW. T(max) for hesperetin in RZZW is about 8.515h, and its C(max) is much larger than that of BZZW. Moreover, it was eliminated slowly as it possessed a much larger AUC value. CONCLUSION: The distinct therapeutic orientations of the Chinese medical formula ZZWs with different Fructus Citrus Immaturus could be elucidated based on the pharmacokinetic parameters of constituents after oral administration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Impaction bone grafting for reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. We used this technique, in combination with a cemented acetabular component, in the acetabula of 304 hips in 292 patients revised for aseptic loosening between 1995 and 2001. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of 10 years following the index operation. Mean follow-up was 12.4 years (SD 1.5; range 10.0-16.0). Kaplan-Meier survivorship with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8%) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared loose radiographically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was a measure forward in cultivating the scientific basis for an approach to examine clinical procedure in Flapless dental implant surgery. The thesis is based on: the systematic review, retrospective study of flapless implants, and in vivo study on the osseo-integration in osteoporotic rats. Dr Doan investigated "clinical procedures used in dental implant treatment in posterior maxilla using flapless technique". The work has yielded significant contributions to the area of implant flapless surgery and its effects on osteoporotic patients having implants in the posterior maxilla.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to use lipidomics to determine if the lipid composition of apolipoprotein-B-containing lipoproteins is modified by dyslipidaemia in type 2 diabetes and if any of the identified changes potentially have biological relevance in the pathophysiology of type 2 diabetes. VLDL and LDL from normolipidaemic and dyslipidaemic type 2 diabetic women and controls were isolated and quantified with HPLC and mass spectrometry. A detailed molecular characterisation of VLDL triacylglycerols (TAG) was also performed using the novel ozone-induced dissociation method, which allowed us to distinguish vaccenic acid (C18:1 n-7) from oleic acid (C18:1 n-9) in specific TAG species. Lipid class composition was very similar in VLDL and LDL from normolipidaemic type 2 diabetic and control participants. By contrast, dyslipidaemia was associated with significant changes in both lipid classes (e.g. increased diacylglycerols) and lipid species (e.g. increased C16:1 and C20:3 in phosphatidylcholine and cholesteryl ester and increased C16:0 [palmitic acid] and vaccenic acid in TAG). Levels of palmitic acid in VLDL and LDL TAG correlated with insulin resistance, and VLDL TAG enriched in palmitic acid promoted increased secretion of proinflammatory mediators from human smooth muscle cells. We showed that dyslipidaemia is associated with major changes in both lipid class and lipid species composition in VLDL and LDL from women with type 2 diabetes. In addition, we identified specific molecular lipid species that both correlate with clinical variables and are proinflammatory. Our study thus shows the potential of advanced lipidomic methods to further understand the pathophysiology of type 2 diabetes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cancers of the brain and central nervous system account for 1.6% of new cancers and 1.8% of cancer deaths globally. The highest rates of all developed nations are observed in Australia and New Zealand. There are known complexities associated with dose measurement of very small radiation fields. Here, 3D dosimetric verification of treatments for small intracranial tumours using gel dosimetry was investigated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There have been substantial advances in small field dosimetry techniques and technologies, over the last decade, which have dramatically improved the achievable accuracy of small field dose measurements. This educational note aims to help radiation oncology medical physicists to apply some of these advances in clinical practice. The evaluation of a set of small field output factors (total scatter factors) is used to exemplify a detailed measurement and simulation procedure and as a basis for discussing the possible effects of simplifying that procedure. Field output factors were measured with an unshielded diode and a micro-ionisation chamber, at the centre of a set of square fields defined by a micro-multileaf collimator. Nominal field sizes investigated ranged from 6×6 to 98×98 mm2. Diode measurements in fields smaller than 30 mm across were corrected using response factors calculated using Monte Carlo simulations of the full diode geometry and daisy-chained to match micro-chamber measurements at intermediate field sizes. Diode measurements in fields smaller than 15 mm across were repeated twelve times over three separate measurement sessions, to evaluate the to evaluate the reproducibility of the radiation field size and its correspondence with the nominal field size. The five readings that contributed to each measurement on each day varied by up to 0.26%, for the “very small” fields smaller than 15 mm, and 0.18% for the fields larger than 15 mm. The diode response factors calculated for the unshielded diode agreed with previously published results, within 1.6%. The measured dimensions of the very small fields differed by up to 0.3 mm, across the different measurement sessions, contributing an uncertainty of up to 1.2% to the very small field output factors. The overall uncertainties in the field output factors were 1.8% for the very small fields and 1.1% for the fields larger than 15 mm across. Recommended steps for acquiring small field output factor measurements for use in radiotherapy treatment planning system beam configuration data are provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is a large amount of research conducted each year examining every aspect of the mechanics of the human body and its interaction with medical devices and the environment; from the cellular level through to the whole body. While, as researchers, we obtain great pleasure from conducting studies and creating new knowledge we need to keep in mind that while this is a good thing it is even better if this new knowledge can lead to improvement in the quality of life for individuals suffering from biomechanical disorders. Such that while commercialisation is a good aim, not all research leads to marketable outcomes. However, it can lead to improvements in surgical techniques and clinical practice. It is important for us to identify and promote how the outcomes of research lead to improvements in quality of care, as this is perhaps the most important outcome for individual patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyondd max and to find ways to mitigate this dependence for measurements in phantoms. Methods Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam (“edge on,” 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. Results For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al2O3) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusions The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinicalin vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to progress beyond currently available medical devices and implants, the concept of tissue engineering has moved into the centre of biomedical research worldwide. The aim of this approach is not to replace damaged tissue with an implant or device but rather to prompt the patient's own tissue to enact a regenerative response by using a tissue-engineered construct to assemble new functional and healthy tissue. More recently, it has been suggested that the combination of Synthetic Biology and translational tissue-engineering techniques could enhance the field of personalized medicine, not only from a regenerative medicine perspective, but also to provide frontier technologies for building and transforming the research landscape in the field of in vitro and in vivo disease models.