996 resultados para 316420090905-moor


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pressures for land use change have led to an increasing isolation of habitat remnants throughout the world. The goal of this study was to estimate the population size and density of some endemic and threatened species in a nature reserve in the Cerrado biome. One hundred and thirty four point transects were undertaken at the Estacao Ecologica de Itirapina (EEI), one of the last natural grassland savannah remnants in Sao Paulo state, in the south-east of Brazil between September and December 2006 and densities estimated for seven species (four endemic to the Cerrado, one near-endemic and two grassland specialists). Neither species reached the minimum viable population size of 500-5000 individuals. Four species, White-banded Tanager, White-rumped Tanager, Black-throated Saltator and Sharp-tailed Tyrant have populations ranging from 112 to 248 individuals, while the other species have a low population (< 60 individuals). The mean densities of Sharp-tailed Tyrant and Cock-tailed Tyrant in the EEI grassland showed similar values to those observed in larger areas of the Cerrado, which may indicate that the EEL grassland area is well conserved. In spite of the restricted size of the EEI, small areas can maintain some endemic and threatened bird populations, thus contributing to local biodiversity and the ecological processes in the region. The capacity of fragments of Cerrado (similar to 2,000 ha) to maintain populations of endemic and threatened bird species is unlikely to be effective in the long term.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the technical feasibility of harvesting a vascularized bone graft from the acromion pedicled on the acromial branch.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clinicopathological and molecular factors determine the prognosis of breast cancer. PRO_10 is a prognostic score based on quantitative RT-PCR of 10 proliferation-associated genes obtained from formalin-fixed, paraffin-embedded breast cancer tissues. We revalidated PRO_10 in patients treated in a non-trial setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anatomical variability within the autonomic nervous system has long been accepted. This study evaluated the anatomical variability of the cervicothoracic ganglion (CTG) according to its form and, in addition, provided precise measurements between the CTG and the anterior tubercle of the transverse process of the sixth cervical vertebra (C6TP), the first costovertebral articulation, and the vertebral artery. Forty-two adult cadavers were dissected, 22 male and 20 females. Five main forms of CTG were documented; spindle (31.9%), dumbbell (23.2%), truncated (21.7%), perforated (14.5%), and inverted-L (8.7%). The means for length, width, and thickness of the CTG were 18.5 mm, 8.2 mm, and 4.5 mm, respectively. The dimensions were found to be slightly larger in the males than females and on the left sides as compared to the right. The mean shortest distance between the CTGs and the vertebral artery was found to be 2.8 mm, whilst the mean shortest distances to C6TP was 25.7 mm and to the first costovertebral articulation was 1.7 mm. There is great variability in the morphology of the CTG with five common forms consistently seen. The relation to the vertebral artery may influence the form of the ganglion. Two previously undocumented forms are recorded; the truncated which describes the important juxtaposition of the CTG and the vertebral artery and the perforated which describes the piercing of the ganglion itself by the artery. The findings are considered to be of clinical importance to anesthetists, surgeons, neurosurgeons, and anatomists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hemodynamic effects related to changes in serum ionized calcium (iCa) are difficult to determine during conventional hemodialysis (HD) using a fixed dialysate concentration of calcium. Regional citrate anticoagulation (RCA) allows the study of the effects of predefined iCa changes on arterial stiffness and blood pressure (BP) during a single dialysis session. In a crossover study, 15 patients with end-stage renal disease underwent two HD sessions with RCA. Each session was divided into two study phases in which iCa was titrated either to 0.8-1.0 mm or to 1.1-1.4 mm. The sequence of phases was randomly chosen and alternated for the second session. After reaching a stable iCa level, pulse wave velocity (PWV), arterial BP, and heart rate were measured. iCa levels were modified during sequence 1 (iCa low-high) from a predialysis baseline value of 1.15 ± 0.09 mm, first to 0.92 ± 0.05 mm (time point 1; P < 0.001 vs. baseline) and then to 1.18 ± 0.05 (time point 2; ns). During sequence 2 (iCa high-low), iCa levels were modified from 1.15 ± 0.12 mm first to 1.20 ± 0.05 mm (time point 1; ns vs. baseline) and then to 0.93 ± 0.03 (time point 2; P < 0.001). Assuming a basic linear repeated measures model, PWV was positively related to iCa levels (P < 0.03) independent of systolic or diastolic BP, heart rate, or ultrafiltration rate. PWV is closely related to acute changes in serum iCa levels in HD patients using RCA. RCA provides an interesting opportunity to study the effects of acute iCa changes during one dialysis procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE The critical shoulder angle (CSA) is an indicator of degenerative shoulder pathologies. CSAs above 35° are associated with degenerative rotator cuff disease, whereas values below 30° are common in osteoarthritis of the glenohumeral joint. Measurements are usually performed on radiographs; however, no data have been reported regarding the reliability of CT scan measurements between different readers or the reproducibility of measurements from radiographs to CT scans. The purpose of our study was to clarify whether CSA measurements on radiographs and CT scans of the same patients show similar values. MATERIALS AND METHODS CSA measurements of 60 shoulders (59 patients) were performed on radiographs and multiplanar reconstructions of corresponding CT scans. Inter-reader reliability and inter-method correlation were calculated. RESULTS The mean discrepancy between readers was only 0.2° (SD ±1.0°) on radiographs. CT scan measurements showed a mean discrepancy of 0.3° (SD ±1.2°). The inter-reader reliability was 0.993 for radiographs and 0.989 for CT scans. There was a very strong inter-method correlation between the CSA measured on radiographs and CT scans (Spearman's rho = 0.974). The mean differences between angles on radiographs and CT measurements were -0.05° (SD ±1.2°) and 0.1° (SD ±1.2°), respectively. CONCLUSION Measurements of the CSA on anterior-posterior radiographs and CT scans are highly correlated, and inter-modality differences are negligible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The etiology of rotator cuff disease is age related, as documented by prevalence data. Despite conflicting results, growing evidence suggests that distinct scapular morphologies may accelerate the underlying degenerative process. The purpose of the present study was to evaluate the predictive power of 5 commonly used radiologic parameters of scapular morphology to discriminate between patients with intact rotator cuff tendons and those with torn rotator cuff tendons. METHODS A pre hoc power analysis was performed to determine the sample size. Two independent readers measured the acromion index, lateral acromion angle, and critical shoulder angle on standardized anteroposterior radiographs. In addition, the acromial morphology according to Bigliani and the acromial slope were determined on true outlet views. Measurements were performed in 51 consecutive patients with documented degenerative rotator cuff tears and in an age- and sex-matched control group of 51 patients with intact rotator cuff tendons. Receiver operating characteristic analyses were performed to determine cutoff values and to assess the sensitivity and specificity of each parameter. RESULTS Patients with degenerative rotator cuff tears demonstrated significantly higher acromion indices, smaller lateral acromion angles, and larger critical shoulder angles than patients with intact rotator cuffs. However, no difference was found between the acromial morphology according to Bigliani and the acromial slope. With an area under the receiver operating characteristic curve of 0.855 and an odds ratio of 10.8, the critical shoulder angle represented the strongest predictor for the presence of a rotator cuff tear. CONCLUSION The acromion index, lateral acromion angle, and critical shoulder angle accurately predict the presence of degenerative rotator cuff tears.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The pathogenesis of full-thickness tears of the rotator cuff remains unclear. Apart from age and trauma, distinct scapular morphologies have been found to be associated with rotator cuff disease. The purpose of the present study was to evaluate whether a score formed using these established risk factors was able to predict the presence of a rotator cuff tear reliably. METHODS We retrospectively assessed a consecutive series of patients with a minimal age of 40 years old, who had true antero-posterior (AP) radiographs of their shoulders, as well as a magnetic resonance (MR) gadolinium-arthrography, between January and December 2011. In all of these patients, the critical shoulder angle (CSA) was determined, and MR images were assessed for the presence of rotator cuff tears. Additionally, the patients' charts were reviewed to obtain details of symptom onset. Based on these factors, the so-called rotator cuff tear (RCT) score was calculated. RESULTS Patients with full-thickness RCTs were significantly older and had significantly larger CSAs than patients with intact rotator cuffs. Multiple logistic regression, using trauma, age and CSA as independent variables, revealed areas under the curve (AUCs) for trauma of 0.55, for age of 0.65 and for CSA of 0.86. The combination of all three factors was the most powerful predictor, with an AUC of 0.92. CONCLUSION Age, trauma and the CSA can accurately predict the presence of a posterosuperior RCT. LEVEL OF EVIDENCE Level IV. Case series with no comparison groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To assess patients' outcomes after subacromial or glenohumeral injections based on the degree of lateral extension of the acromion. METHODS 307 patients were prospectively included after therapeutic fluoroscopy-guided subacromial (n = 148) or glenohumeral (n = 159) injections with anaesthetic and long-acting corticosteroids. Pre- and post-injection outcomes at 1 week and 1 month were obtained using the 11-point numerical rating scale (NRS) for pain. Lateral extension of the acromion was quantified and categorized by the critical shoulder angle (CSA) and the acromion index (AI) on anteroposterior conventional radiographs. RESULTS Patients' outcomes at 1 week and 1 month were significantly improved (p < 0.001) compared to baseline for subacromial and glenohumeral injection patients. Patients with a CSA <35° showed significantly higher pain reduction 1 month after subacromial injection compared to patients with a CSA >35° (4.2 ± 2.6 vs. 3.2 ± 3.0, p = 0.04). A significant difference in the 1-month NRS change in pain scores is noted for smaller AIs after subacromial injection (4.3 ± 2.8 vs. 2.6 ± 2.9; p = 0.01). No significant association was noted between clinical outcome and the lateral extension of the acromion after glenohumeral joint injections. CONCLUSIONS A short lateral extension of the acromion was associated with better clinical outcomes in subacromial injection patients but not in glenohumeral injection patients. KEY POINTS • Patients' outcomes at 1 month improved significantly compared to baseline for subacromial injections. • Patients' outcomes at 1 month improved significantly compared to baseline for glenohumeral injections. • Short acromial lateralization was associated with better clinical outcome after subacromial injection. • The acromial lateralization was not associated with clinical outcome after glenohumeral injection.