901 resultados para 131I-iodide


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

F(ab')2-fragments of the anti-melanoma monoclonal antibody MeI-14 were labelled with 123I for external scanning and with 125I for tissue measurement of radioactivity and injected intravenously into patients scheduled for surgical resection of a glioma. The paired-label study was performed by injecting simultaneously 131I-labelled control (F(ab')2-fragments. The patients were scanned by computerised tomoscintigraphy. After surgery, the activities of 125I and 131I were counted in tumour and normal tissues. The results indicate that there was a low but definite uptake of the antibody in the tumour due to its specificity. The external detection was difficult because of accumulation of antibody fragments in the skull.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of tumor necrosis factor alpha (TNFalpha) in cancer therapy is limited by its short circulatory half-life and its severe systemic side effects. To overcome these limitations, we evaluated the capability of a bispecific antibody (BAb) directed against carcinoembryonic antigen (CEA) and human TNFalpha to target this cytokine in tumors. A BAb was constructed by coupling the Fab' fragments from an anti-CEA monoclonal antibody (MAb) to the Fab' fragments from an anti-TNFalpha MAb via a stable thioether linkage. The double specificity of the BAb for CEA and TNFalpha was demonstrated using a BIAcoreTM two-step analysis. The affinity constants of the BAb for CEA immobilized on a sensor chip and for soluble TNFalpha added to the CEA-BAb complex were as high as those of the parental MAbs (1.7 x 10(9) M-1 and 6.6 x 10(8) M-1, respectively). The radiolabeled 125I-labeled BAb retained high immunoreactivity with both CEA and TNFalpha immobilized on a solid phase. In nude mice xenografted with the human colorectal carcinoma T380, the 125I-labeled BAb showed a tumor localization and biodistribution comparable to that of 131I-labeled anti-CEA parental F(ab')2 with 25-30% of the injected dose (ID)/g tumor at 24 h and 20% ID/g tumor at 48 h. To target TNFalpha to the tumor, a two-step i.v. injection protocol was used first, in which a variable dose of 125I-labeled BAb was injected, followed 24 or 48 h later by a constant dose of 131I-labeled TNFalpha (1 microg). Mice pretreated with 3 microg of BAb and sacrificed 2, 4, 6, or 8 h after the injection of TNFalpha showed a 1.5- to 2-fold increased concentration of 131I-labeled TNFalpha in the tumor as compared to control mice, which received TNFalpha alone. With a higher dose of BAb (25 microg), mice showed a better targeting of TNFalpha with a 3.2-fold increased concentration of 131I-labeled TNFalpha in the tumor: 9.3% versus 2.9% ID/g in control mice 6 h after TNFa injection. In a one-step injection protocol using a premixed BAb-TNFalpha preparation, similar results were obtained 6 h postinjection (3.5-fold increased TNFalpha tumor concentration). A longer retention time of TNFalpha was observed leading to an 8.1-fold increased concentration of TNFalpha in the tumor 14 h postinjection (4.4 versus 0.5% ID/g tumor for BAb-treated and control mice, respectively). These results show that our BAb is able, first, to localize in a human colon carcinoma and, there, to immunoabsorb the i.v.-injected TNFalpha, leading to its increased concentration at the tumor site.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: In the radiopharmaceutical therapy approach to the fight against cancer, in particular when it comes to translating laboratory results to the clinical setting, modeling has served as an invaluable tool for guidance and for understanding the processes operating at the cellular level and how these relate to macroscopic observables. Tumor control probability (TCP) is the dosimetric end point quantity of choice which relates to experimental and clinical data: it requires knowledge of individual cellular absorbed doses since it depends on the assessment of the treatment's ability to kill each and every cell. Macroscopic tumors, seen in both clinical and experimental studies, contain too many cells to be modeled individually in Monte Carlo simulation; yet, in particular for low ratios of decays to cells, a cell-based model that does not smooth away statistical considerations associated with low activity is a necessity. The authors present here an adaptation of the simple sphere-based model from which cellular level dosimetry for macroscopic tumors and their end point quantities, such as TCP, may be extrapolated more reliably. METHODS: Ten homogenous spheres representing tumors of different sizes were constructed in GEANT4. The radionuclide 131I was randomly allowed to decay for each model size and for seven different ratios of number of decays to number of cells, N(r): 1000, 500, 200, 100, 50, 20, and 10 decays per cell. The deposited energy was collected in radial bins and divided by the bin mass to obtain the average bin absorbed dose. To simulate a cellular model, the number of cells present in each bin was calculated and an absorbed dose attributed to each cell equal to the bin average absorbed dose with a randomly determined adjustment based on a Gaussian probability distribution with a width equal to the statistical uncertainty consistent with the ratio of decays to cells, i.e., equal to Nr-1/2. From dose volume histograms the surviving fraction of cells, equivalent uniform dose (EUD), and TCP for the different scenarios were calculated. Comparably sized spherical models containing individual spherical cells (15 microm diameter) in hexagonal lattices were constructed, and Monte Carlo simulations were executed for all the same previous scenarios. The dosimetric quantities were calculated and compared to the adjusted simple sphere model results. The model was then applied to the Bortezomib-induced enzyme-targeted radiotherapy (BETR) strategy of targeting Epstein-Barr virus (EBV)-expressing cancers. RESULTS: The TCP values were comparable to within 2% between the adjusted simple sphere and full cellular models. Additionally, models were generated for a nonuniform distribution of activity, and results were compared between the adjusted spherical and cellular models with similar comparability. The TCP values from the experimental macroscopic tumor results were consistent with the experimental observations for BETR-treated 1 g EBV-expressing lymphoma tumors in mice. CONCLUSIONS: The adjusted spherical model presented here provides more accurate TCP values than simple spheres, on par with full cellular Monte Carlo simulations while maintaining the simplicity of the simple sphere model. This model provides a basis for complementing and understanding laboratory and clinical results pertaining to radiopharmaceutical therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While it is now well accepted that radiolabeled antibodies can be useful for tumour detection by immunoscintigraphy, the use of larger doses of more aggressive radioisotopes coupled to antibodies for radioimmunotherapy is still in its infancy. At the experimental level, our group has shown that the intravenous injection of large doses of 131I labeled F(ab')2 fragments from monoclonal anti-carcinoembryonic antigen (CEA) antibodies can eradicate well established human colon carcinoma xenografts in nude mice. At the clinical level, in a dosimetry study performed at the Institut Gustave Roussy, the same anti-CEA monoclonal antibodies and fragments, labeled with subtherapeutic doses of 131I, were injected in patients with liver metastases from colorectal carcinomas. Direct measurement of radioactivity in surgically resected liver metastases and normal liver confirmed the specificity of tumour localization of the antibodies, but also showed that the calculated radiation doses which could be delivered by injections of 200 to 300 mCi of 131I labeled antibodies or fragments, remained fairly low, in the range of 1,500 to 3,000 rads. This is obviously insufficient for a single modality treatment. An alternative approach is to inject radiolabeled antibodies intra peritoneally to treat peritoneal carcinomatosis. Several clinical studies using this strategy are presently under evaluation and suggest that positive results can be obtained when the tumour diameters are very small. In systemic radioimmunotherapy, positive results have been obtained in more radiosensitive types of malignancies such as B cell lymphomas by intravenous injection of antibodies directed against B cell differentiation markers or against idiotypic antigens from each lymphoma, and labeled with 131I or 90Y. The major directions of research for improvement of radioimmunotherapy include the design of genetically engineered new forms of humanized antibodies, the synthesis of original chelates for coupling new radioisotopes to antibodies and the development of two step strategies for immunolocalization of radioisotopes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El rastreo corporal total (RCT) luego de la primera radioablación con 131I en pacientes diagnosticados de carcinoma diferenciado de tiroides (CDT) permite una re-estadificación de la enfermedad. Sin embargo, su información anatómica es escasa y la elevada actividad de los restos tiroideos puede interferir con la detección de adenopatías cervicales. En este estudio se determinó el valor diagnóstico de la SPECT-TC respecto al RCT, concluyendo que la misma aporta información relevante para determinar el compromiso ganglionar, resolviendo los patrones indeterminados observados en los estudios planares y permitiendo una mejor estadificación de los pacientes al final de su periodo de tratamiento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A bispecific MAb was derived from the fusion of a hybridoma producing MAb CD3 with a hybridoma producing MAb L-DI (which is directed against a 41-kDa glycoprotein expressed in most gastro-intestinal and pancreatic carcinomas). Bispecific antibody molecules were isolated from parental antibody molecules by the use of hydroxylapatite-HPLC and shown to target human cytolytic T lymphocytes, irrespective of their original specificity, to specifically lyse human colon carcinoma cells. Localization studies in vivo using nude mice bearing human colon carcinoma xenografts showed significant accumulation of the HPLC-purified 125I-labelled bispecific antibodies into the tumor compared to 131I-labelled control CD3 antibody.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The expected therapeutic gain of a combined radioimmunotherapy (RIT) with conventional radiotherapy (RT) would be a synergy of tumor irradiation, provided that toxic, dose-limiting side effects concern different organs. We have shown in a model of subcutaneous human colon cancer transplants in nude mice that RIT with 131I-labeled anti-CEA antibody fragments combined with fractionated RT give an additive therapeutic effect without increase of side effects. A second study of different timing schedules of RIT and RT has shown that close association of both therapies without delay is more efficient than a therapy with a treatment-free interval of two weeks. In a new model of human colon cancer liver metastases in nude mice, early treatment with RIT and with RT has been curative, whereas therapies initiated later were less efficient, suggesting that the combined therapy is likely to be more efficient in an adjuvant situation after surgery. At the clinical level, six patients with limited liver metastatic disease from colorectal cancer were treated with RIT using 200 mCi 131I-labeled anti-CEA MAb F(ab')2 fragments combined with fractionated external beam RT of 20 Gy to the entire liver. As expected, spontaneously reversible bone marrow toxicity grade 3 to 4 and reversible liver toxicity grade 1 to 3 have been observed. By computerized tomography, three patients showed stable disease and one patient partial remission, whereas two patients had progressive disease. In conclusion, animal experiments have shown a clear advantage of combined RT and RIT, and the clinical study shows the feasibility of such a therapy in patients with colorectal cancer liver metastases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monoclonal antibodies (Mab) directed against distinct epitopes of the human 240 kD melanoma-associated antigen have been evaluated for their capacity to localize in human melanoma grafted into nude mice. A favorable tumor to normal tissue ratio of 13 was obtained with intact 131I-labeled MAb Me1-14. This ratio was further increased to 43 and 23 by the use of F(ab')2 and Fab fragments, respectively. The specificity of tumor localization was demonstrated by the simultaneous injection of F(ab')2 fragments from MAb Me1-14 and anti-CEA MAb 35, each labeled with a different iodine isotope, into nude mice grafted with a melanoma and colon carcinoma. The fragments from both MAb localized with perfect selectivity in their relevant tumor as shown by differential whole body scanning and by direct measurement of the two isotopes in tumors and normal tissues. These in vivo experimental results suggest that the F(ab')2 fragment from MAb Me1-14 is suitable for melanoma detection by immunoscintigraphy in patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine whether multiwalled carbon nanotubes (MWNCT) are taken up by and are toxic to human intestinal enterocytes using the Caco-2 cell model. Caco-2 cells were exposed to 50 ?g/ml MWCNT (oxidized or pristine) for 24 h, and experiments were repeated in the presence of 2.5 mg/L natural organic matter. Cells displayed many of the properties that characterize enterocytes, such as apical microvilli, basolateral basement membrane, and glycogen. The cell monolayers also displayed tight junctions and electrical resistance. Exposure to pristine and oxidized MWCNT, with or without natural organic matter, did not markedly affect viability, which was assessed by measuring activity of released lactate dehydrogenase (LDH) and staining with propidium iodide. Ultrastructural analysis revealed some damage to microvilli colocalized with the MWCNT; however, neither type of MWCNT was taken up by Caco-2 cells. In contrast, pristine and oxidized MWCNT were taken up by the macrophage RAW 264.7 line. Our study suggests that intestinal enterocytes cells do not take up MWCNT. [Authors]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During one week, beginning 18 days after transplantation, nude mice bearing human colon carcinoma ranging from 115 to 943 mm3 (mean 335 mm3) were treated by repeated intravenous injections of either iodine-131-(131I) labeled intact antibodies or 131I-labeled corresponding F(ab')2 fragments of a pool of four monoclonal antibodies (MAbs) directed against distinct epitopes of carcinoembryonic antigen (CEA). Complete tumor remission was observed in 8 of 10 mice after therapy with F(ab')2 and 6 of the animals survived 10 mo in good health. In contrast, after treatment with intact MAbs, tumors relapsed in 7 of 8 mice after remission periods of 1 to 3.5 mo despite the fact that body weight loss and depression of peripheral white blood cells, symptoms of radiation toxicity, and the calculated radiation doses for liver, spleen, bone, and blood were increased or equal in these animals as compared to mice treated with F(ab')2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A highly efficient synthesis of the biologically important fluorescent probe dansyl α-GalCer is presented. Key in our strategy is the incorporation of the fluorescent dansyl group at an early stage in the synthesis to facilitate in the monitoring and purification of intermediates via TLC and flash column chromatography, respectively, and the use of a high yielding α-selective glycosylation reaction between the phytosphingosine lipid and a galactosyl iodide donor. The ability of dansyl α-GalCer to activate iNKT cells and to serve as a fluorescent marker for the uptake of glycolipid by dendritic cells is also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the regulation of connexin expression by fluid pressure, we have studied the effects of elevated transmural urine pressure on Connexin43 (Cx43) and Cx26. We chose to focus on these two proteins out of the five connexins (Cx26, 43, 40, 37, and 45) which we found by RT-PCR to be expressed in the rat bladder, since in situ hybridization and immunofluorescence showed that Cx43 is the predominant connexin expressed by smooth muscle cells (SMC), whereas Cx26 is abundantly expressed only in the latter cell type. To evaluate whether these connexins are affected by changes in transmural urine pressure, we used a rat model of bladder outlet obstruction, in which a ligature is placed around the urethra. Under conditions of increased fluid pressure due to urine retention, we observed that the expression of both Cx43 and Cx26 increased at both transcript and protein levels, reaching a maximum 7-9 h after the ligature. Further analysis revealed that these changes were accounted for by a fourfold increase in Cx43 mRNA of SMC but not urothelial cell and by a fivefold increase in Cx26 mRNA of urothelium. Scrape-loading of propidium iodide showed that the latter change was paralleled by a twofold increase in coupling between urothelial cells. The data show that Cx43 and Cx26 are differentially regulated during bladder outlet obstruction and contribute to the response of the bladder wall to increased voiding pressure, possibly to control its elasticity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biodistribution and tumor uptake of a chimeric human-mouse monoclonal antibody (MAb) and the original mouse MAb have been comparatively studied. METHODS: Eighteen patients with suspected colorectal cancer scheduled for surgery underwent immunoscintigraphy with 123I-labeled chimeric anti-CEA MAb. Iodine-125 and 131I trace-labeled chimeric and original mouse MAb were simultaneously injected for biodistribution studies. RESULTS: Similar serum kinetics and a low immunogenicity were observed for both antibodies. Mean binding capacity to CEA measured in PBS after radiolabeling was identical for both MAbs and it was slightly decreased when measured in serum 1-4 hr after injection. Radiochromatograms of patients sera showed immune complex formation related to the amount of circulating CEA. Postoperative ex vivo radioactivity counting in tissue samples revealed similar antibody distributions with notably similar antibody uptakes in tumors. High tumor uptakes (between 0.02 to 0.06% injected dose per g) were observed in 3 of 13 patients operated for primary or metastatic colorectal cancer. CONCLUSION: In this dual-label technique, the radioiodinated anti-CEA IgG4 chimeric MAb and the original mouse IgG1 MAb were shown to have very similar behavior in colorectal cancer patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four monoclonal antibodies against carcinoembryonic antigen (CEA) have been selected from 32 hybrids that produce antibodies against this antigen, by the criteria of high affinity for CEA and low cross-reactivity with granulocyte glycoprotein(s). The specificity of tumor localization in vivo of the four MAb, and their F(ab')2 and Fab fragments was compared in nude mice bearing grafts of a serially transplanted, CEA-producing, human colon carcinoma. The distribution of radiolabeled MAb and their fragments after intravenous injection was analyzed by direct measurement of radioactivity in tumor and normal organs, as well as by whole-body scanning and by autoradiography of tumor sections. Paired labeling experiments, in which 131I-labeled antibody or fragments and 125I-labeled control IgG are injected simultaneously, were undertaken to determine the relative tumor uptakes of each labeled protein. The tumor antibody uptake divided by that of control IgG defines the specificity index of localization. Tumor antibody uptakes (as compared with the whole mouse), ranging between 7 and 15, and specificity indices ranging between 3.4 and 6.8, were obtained with the four intact MAb at day 4-5 after injection. With F(ab')2 fragments of the four MAb, at day 3, the tumor antibody uptakes ranged between 12 and 24 and the specificity indices between 5.3 and 8.2. With the Fab fragments prepared from the two most promising MAb, the antibody uptakes reached values of 34 and 82 at day 2-3 and the specificity indices were as high as 12 and 19. The scanning results paralleled those obtained by direct measurement of radioactivity. With intact MAb, tumor grafts of 0.5-1 g gave very contrasted positive scans 3 d after injection. Using MAb fragments, tumors of smaller size were detectable earlier. The best results were obtained with Fab fragments of MAb 35, which gave clear detections of tumors weighing only 0.1 g as early as 48 h after injection. Autoradiographs of tumor sections from mice injected with 125I-labeled MAb demonstrated that the radioactivity was localized in the tumor tissues and not in the stromal connective tissue of mouse origin. The highest radioactivity concentration was localized in areas known to contain CEA such as the pseudolumen of glands and the apical side of carcinoma cells. The penetration of radioactivity in the central part of tumor nodules and the pseudolumen appeared to be increased with the use of MAb fragments.