117 resultados para ulna
Resumo:
Mesenchymal stem cells (MSCs) were demonstrated to exist within peripheral blood (PB) of several mammalian species including human, guinea pig, mice, rat, and rabbit. Whether or not the PB derived MSCs (PBMSCs) could enhance the regeneration of large bone defects have not been reported. In this study, rabbit MSCs were obtained from mononuclear cells (MNCs) cultures of both the PB and bone marrow (BM) origin. The number of PBMSCs was relatively lower, with the colony forming efficiency (CFE) ranging from 1.2-13 per million MNCs. Under specific inductive conditions, PBMSCs differentiated into osteoblasts, chondrocytes, and adipocytes, showing multi- differentiation ability similar to BMMSCs. Bilateral 20 mm critical-sized bone defects were created in the ulnae of twelve 6-month old New Zealand white rabbits. The defects were treated with allogenic PBMSCs/Skelite (porous calcium phosphate resorbable substitute), BMMSCs/Skelite, PBMNCs/Skelite, Skelite alone and left empty for 12 weeks. Bone regeneration was evaluated by serial radiography, peripheral quantitative computed tomography (pQCT), and histological examinations. The x-ray scores and the pQCT total bone mineral density in the PBMSCs/Skelite and BMMSCs/Skelite treated groups were significantly greater than those of the PBMNCs/Skelite and Skelite alone groups (p
Resumo:
O objetivo do presente trabalho foi o de estudar a resistência à corrosão em placas de aço inoxidável 316L, com diferentes tipos de acabamento e tratamento superficial, e a possível interferência dessa reação corrosiva na consolidação óssea. Utilizaram-se placas semi-acabadas, polidas, tratadas com jatos de microesferas de vidro e passivadas, as quais foram aplicadas na epífise distal do rádio de cães. Foram utilizados 12 animais, divididos em dois grupos, nos quais, após osteotomia bilateral do rádio e ulna, foram realizadas osteossínteses do rádio, totalizando 24 procedimentos. Avaliou-se a evolução clínica e radiográfica das regiões que receberam os implantes aos 30, 60, 90, 180, 240 e 360 dias. Os animais do grupo 1 (GI) foram sacrificados aos 180 dias e os do GII aos 360 dias para estudo histológico e de microscopia eletrônica de varredura do local da osteotomia sob a região dos implantes metálicos e para estudo da resistência à corrosão no organismo, pelos implantes metálicos, por meio de análises química e metalográfica (microscopia óptica e eletrônica de varredura e espectroscopia de espalhamento de energia por raios X). Os animais recuperaram a função dos membros operados 24 horas após a cirurgia. Radiograficamente, verificou-se a consolidação óssea em todos os animais. Macro e microscopicamente não foram observados sinais de corrosão nos implantes metálicos, exceto em uma placa passivada, aplicada no rádio esquerdo de um animal, na qual a corrosão foi detectada pela microscopia óptica e eletrônica de varredura. Este estudo permite concluir que as placas de aço inoxidável 316L, independente do acabamento superficial a que foram submetidas, não sofreram corrosão ou reações adversas e foram efetivas no tratamento das fraturas experimentais do rádio e ulna de cães.
Resumo:
O objetivo do estudo foi analisar histologicamente a qualidade, tipo e orientação dos tecidos formados na área de regeneração óssea produzida durante alongamento simultâneo do rádio e da ulna, com fixador externo de Ilizarov, a partir de osteotomia subperiosteal diafisária distal, com dois incrementos diários de 0,5 mm. A montagem foi composta de dois anéis e quatro hastes telescópicas, sendo a distração óssea iniciada no sexto dia de pós-operatório. Utilizaram-se 15 cães, sem raça definida, adultos, com peso corpóreo entre 17 e 30 kg, divididos por sorteio em subgrupos (A, B, C, D e E) compostos por três animais, que foram submetidos a eutanásia após os seguintes procedimentos: A- oito dias de alongamento, B- 15 dias de alongamento, C- 22 dias de alongamento, D- 28 dias de alongamento e oito dias de fase neutra com o fixador, E- 28 dias de alongamento, 60 dias de fase neutra com fixador e 45 dias sem fixador. Os resultados obtidos mostram que o tipo e localização da osteotomia, bem como o ritmo de distração utilizado, não interferiram sobremaneira na regeneração óssea. A reparação óssea foi eficiente, notadamente intramembranosa, contudo nos subgrupos B e C foi observada a presença de cartilagem.
Resumo:
A female, adult, 27 kg Giant Anteater (Myrmecophaga tridactyla) was directed to the veterinary hospital by the Center ofSelection of Wild Animals (Cetas) of the Brazilian Institute for the Environment and Renewable Natural Resources (Ibama), afterit was found on a highway. After clinical and radiologic examination, radius and ulna fractures of the left thoracic memberwere observed. Taking in consideration to the physical status of the animal, its size, the type of fracture and resources availablein the hospital veterinary, internal fixation with Intramedullary Pinning (on the Radius and Ulna) was the treatment methodchosen. About 35 days after the surgery the animal was walking without difficulties and by x-ray it was possible to observeformation of callus. The presence of decurrent bony deformities due to the type of fixation was not found. As the animal presentedno more difficulties in walking, we opted for its reintroduction to its original environment. The aim of the present casestudy is sharing the results of the Intramedullary Pinning implantation technique, widely used in dogs and cats, now used in a Giant Anteater (Myrmecophaga tridactyla).
Resumo:
O objetivo do estudo foi avaliar a eficácia do fixador esquelético pino-resina, configuração tipo II, coadjuvado pelo enxerto ósseo esponjoso autólogo, no tratamento das complicações secundárias à imobilização inadequada de fraturas do rádio e ulna em 10 cães, com peso entre 1,8 e 33,6 kg. Detectou-se não-união (n=4), osteomielite (n=1), má-união (n=1), falência ou quebra de implante (n=4), sendo 60% das lesões referente ao uso prévio de pino intramedular no rádio. A montagem do fixador foi realizada com transfixação de pinos lisos em sua maioria angulados, cujas extremidades excedentes foram dobradas e estabilizadas com resina acrílica. em todos os casos, utilizou-se enxerto esponjoso autólogo fresco, após debridamento do foco de fratura. O tempo de permanência do aparelho variou entre 45 dias e 5 meses e a maior complicação foi o afrouxamento dos pinos transfixantes. A consolidação das fraturas ocorreu por formação de calo periosteal de mínimo a moderado, indicando boa rigidez da montagem.
Resumo:
A 3-year-old, male crossbred dog with osteomyelitis of the radius and ulna was treated using Ilizarov's method. Two centimeters of infected bone was resected, then acute bone shortening and subsequent lengthening of a healthy bone site were performed. The infection was eradicated, but a residual leg-length discrepancy was present.
Resumo:
An 8-year-old male Boxer with a severely contaminated open fracture of the left radius and ulna fracture, produced by a helicopter propeller, was treated using bone transport by the Ilizarov method. Extensive diaphyseal bone loss and soft-tissue vascular damage were present. The radius and ulna were stabilised with an Ilizarov ring external fixator. The bone defect was partially shortened and restored by gradual transport of a bone segment created from proximal segments of the radius and ulna. The external fixator was removed 4fi months after the beginning of the latency period, due to instability caused by osteolysis around the wires. A cast was placed for 3 weeks. Although the bone transport had resulted in formation of approximately 4 cm of bone, the antebrachium showed approximately 50% shortening when compared to the contralateral limb. The infection was eradicated, and the dog was able to bear weight on the operated limb when walking.
Resumo:
Com o objetivo de avaliar a funcionalidade de uma montagem do aparelho de Ilizarov para o alongamento simultâneo do rádio e da ulna, foram utilizados 15 cães, sem raça definida, adultos, com peso entre 17 e 27kg. Aplicado um fixador composto de dois anéis e quatro hastes telescópicas, realizaram-se osteotomia subperiosteal diafisária distal do rádio e ulna e distração óssea, iniciada no sexto dia de pós-operatório. Os animais foram divididos em cinco grupos formados cada um por três cães, submetidos às seguintes condutas: A- oito dias de alongamento, B- 15 dias de alongamento, C- 22 dias de alongamento, D- 28 dias de alongamento e oito dias de fase neutra com o fixador e E- 28 dias de alongamento, 60 dias de fase neutra com fixador e 45 dias sem fixador. No período de distração os animais desenvolveram gradual e progressiva contratura em flexão da articulação antebraquiocárpica, que persistiu no grupo E após a remoção do fixador. Conclui-se que no alongamento do antebraço há tendência para o desenvolvimento de contratura, recomendando-se medidas preventivas e fisioterapia.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A giant anteater (Myrmecophaga tridactyla) was found with closed comminuted fractures on the fight radius and ulna and left humerus he duration of which was unknown. The animal was unable to use either of he thoracic limbs. The fractures were stabilized with 3.5-mm titanium plates and a commercially available mixture of micro lyophilized bovine cortical osseous and bovine BMP (Gen-tech(R), Baumer, Brazil) was implanted into the fractures sites. Postoperative radiographic evaluations were performed every 30 days and after four months. Bone healing was observed in all of he fractures. The animal was able to be reintroduced into its natural habitat. From his case we conclude that despite he low metabolic fate of the giant anteater, which is an inherent characteristic of this species, he treatment of radius, ulna and humerus fractures by means of plates and screws, associated with BMP on the Myrmecophaga tridactyla, was a success.
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ