322 resultados para thinner


Relevância:

20.00% 20.00%

Publicador:

Resumo:

25th International Cryogenic Engineering Conference and the International Cryogenic Materials Conference in 2014, ICEC 25–ICMC 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract:The objective of this work was to evaluate the effect of abscisic acid, applied at different rates and different fruit developmental stages, on the thinning of 'Chiripá' peach. Abscisic acid (ABA) at 500 mg L-1 was applied at three stages of fruit development based on lignin deposition: stage 1, at 24 days after full bloom (DAFB); stage 2, at 40 DAFB; and stage 3, at 52 DAFB. Only ABA application at stage 2 - 40 DAFB - reduced fruit set and the number of fruit per plant. Three ABA concentrations (350, 500, and 750 mg L-1) were then applied at 40 DAFB. All rates increased fruit ethylene production and fruit abscission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El thinner es uno de los productos de mayor utilización en la industria de las pinturas, lubricantes y pegamentos. Su composición es variable de acuerdo con su uso y calidad. Sin embargo, la exposición crónica es una preocupación debido a que puede afectar órganos principales tales como pulmones, hígado, riñón y glándulas suprarrenales. En este estudio fue caracterizada la composición de varias muestras de thinner, disponibles comercialmente en la ciudad de Cartagena, que fueron recolectadas en diferentes almacenes y analizadas por cromatografía de gases acoplada a espectrometría de masas (GC/MS). Los resultados mostraron que no solo la composición, sino también la distribución relativa de los componentes presentes en las muestras son variables. Treinta y dos compuestos fueron detectados, entre los que se encuentran: tolueno, o-xileno, pxileno y etilbenceno, con frecuencias de aparición de 91,7, 66,7, 75,0 y 66,7 %, respectivamente. El desconocimiento del riesgo de intoxicación, generado al manipular este tipo de mezclas, puede ser la causa de muchos de los problemas de salud en personas expuestas al thinner, tanto en actividades laborales como domésticas. Una minería de datos mostró la asociación potencial entre los componentes del thinner y manifestaciones clínicas, las cuales incluyen daño renal y hepático, pérdida de cabello, alteraciones hematológicas, dermatitis, ansiedad y problemas de equilibrio, entre otras. En conclusión, el thinner posee gran variabilidad tanto en sus componentes como en la proporción relativa de los mismos. Los efectos perjudiciales en la salud por exposición directa o indirecta a estos componentes han sido ampliamente descritos en la literatura

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antisocial and violent behaviour have been associated with both structural and functional brain abnormalities in the frontal and the temporal lobes. The aim of the present study was to assess cortical thickness in offenders undergoing forensic psychiatric assessments, one group with psychopathy (PSY, n=7) and one group with autism spectrum disorder (ASD, n=7) compared to each other as well as to a reference group consisting of healthy non-criminal subjects (RG, n=12). A second aim was to assess correlation between scores on a psychopathy checklist (PCL-SV) and cortical thickness. Magnetic resonance imaging (MRI) and surface-based cortical segmentation were used to calculate cortical thickness. Analyses used both regions of interest and statistical maps. When the two groups of offenders were compared, there were no differences in cortical thickness, but the PSY group had thinner cortex in the temporal lobes and in the whole right hemisphere compared to RG. There were no differences in cortical thickness between the ASD group and RG. Across subjects there was a negative correlation between PCL-SV scores and cortical thickness in the temporal lobes and the whole right hemisphere. The findings indicate that thinner cortex in the temporal lobes is present in psychopathic offenders and that these regions are important for the expression of psychopathy. However, whether thinner temporal cortex is a cause or a consequence of the antisocial behaviour is still unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To identify individual retinal layer thickness changes associated with visual acuity gain in diabetic macular edema treated with ranibizumab using layer segmentation on high-resolution optical coherence tomography scans. METHODS Retrospective observational case series. Thirty-three treatment-naive eyes with diabetic macular edema were imaged by spectral domain optical coherence tomography at monthly visits while receiving intravitreal ranibizumab treatment as needed, guided by visual acuity. Thickness changes of individual layers after 1 year were quantitatively analyzed and correlated with visual acuity gain. RESULTS The mean best-corrected visual acuity improvement at 1 year was 6.2 (SEM ± 1.5) Early Treatment Diabetic Retinopathy Study letters, and central retinal thickness decreased by 66 ± 18 μm. In the central subfield, there was a significant decrease of thickness for all layers (P < 0.05) except the outer nuclear layer. Multiple linear regression analysis revealed that thickness decrease of the inner retina was associated with better visual acuity, whereas for the outer retina the opposite was true. The best estimate of final visual acuity (R = 0.817, P < 0.001) was obtained, by including baseline visual acuity and thickness change of the inner and outer plexiform layers in the model. CONCLUSION Whereas thickness decrease of the inner retina was positively associated with visual acuity gain, the opposite was found for the outer retina. This might be indirect evidence for recovery of the outer retina during ranibizumab treatment.This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0 (CC BY-NC-ND), which permits downloading and sharing the work provided it is properly cited. The work cannot be changed in any way or used commercially.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cases of tendinopathy and tendon ruptures have been reported as side effects associated with statin therapy. This work assessed possible changes in the structural and biomechanical properties of the tendons after chronic treatment with statins. Wistar rats were divided into the following groups: treated with atorvastatin (A-20 and A-80), simvastatin (S-20 and S-80) and the group that received no treatment (C). The doses of statins were calculated using allometric scaling, based on the doses of 80 mg/day and 20 mg/day recommended for humans. The morphological aspect of the tendons in A-20, S-20 and S-80 presented signals consistent with degeneration. Both the groups A-80 and S-80 showed a less pronounced metachromasia in the compression region of the tendons. Measurements of birefringence showed that A-20, A-80 and S-80 groups had a lower degree of organization of the collagen fibers. In all of the groups treated with statins, the thickness of the epitenon was thinner when compared to the C group. In the biomechanical tests the tendons of the groups A-20, A-80 and S-20 were less resistant to rupture. Therefore, statins affected the organization of the collagen fibers and decreased the biomechanical strength of the tendons, making them more predisposed to ruptures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

cDNA arrays are a powerful tool for discovering gene expression patterns. Nylon arrays have the advantage that they can be re-used several times. A key issue in high throughput gene expression analysis is sensitivity. In the case of nylon arrays, signal detection can be affected by the plastic bags used to keep membranes humid. In this study, we evaluated the effect of five types of plastics on the radioactive transmittance, number of genes with a signal above the background, and data variability. A polyethylene plastic bag 69 μm thick had a strong shielding effect that blocked 68.7% of the radioactive signal. The shielding effect on transmittance decreased the number of detected genes and increased the data variability. Other plastics which were thinner gave better results. Although plastics made from polyvinylidene chloride, polyvinyl chloride (both 13 μm thick) and polyethylene (29 and 7 μm thick) showed different levels of transmittance, they all gave similarly good performances. Polyvinylidene chloride and polyethylene 29 mm thick were the plastics of choice because of their easy handling. For other types of plastics, it is advisable to run a simple check on their performance in order to obtain the maximum information from nylon cDNA arrays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: a tomografia computadorizada (TC) permite a visualização do osso alveolar que recobre os dentes por vestibular e lingual. OBJETIVO: o propósito deste estudo foi expor e discutir as implicações da morfologia do osso alveolar, visualizado por meio da TC, sobre o diagnóstico e plano de tratamento ortodôntico. MÉTODOS: foram descritas as evidências sobre a inter-relação entre características dentofaciais e a morfologia das tábuas ósseas vestibular e lingual, assim como evidências sobre a repercussão da movimentação ortodôntica sobre o nível e espessura dessas estruturas periodontais. RESULTADOS: pacientes adultos podem apresentar deiscências ósseas previamente ao tratamento ortodôntico, principalmente na região dos incisivos inferiores. Os pacientes com padrão de crescimento vertical parecem apresentar menor espessura das tábuas ósseas vestibular e lingual no nível do ápice dos dentes permanentes, comparados a pacientes com padrão de crescimento horizontal. O movimento dentário vestibulolingual descentraliza os dentes do rebordo alveolar e ocasiona deiscências ósseas. CONCLUSÃO: a morfologia do rebordo alveolar constitui um fator limitante para a movimentação dentária e deve ser considerada, de forma individual, na realização do plano de tratamento ortodôntico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epidemiological studies have suggested that cola beverage consumption may affect bone metabolism and increase bone fracture risk. Experimental evidence linking cola beverage consumption to deleterious effects on bone is lacking. Herein, we investigated whether cola beverage consumption from weaning to early puberty delays the rate of reparative bone formation inside the socket of an extracted tooth in rats. Twenty male Wistar rats received cola beverage (cola group) or tap water (control group) ad libitum from the age of 23 days until tooth extraction at 42 days and euthanasia 2 and 3 weeks later. The neoformed bone volume inside the alveolar socket was estimated in semi-serial longitudinal sections using a quantitative differential point-counting method. Histological examination suggested a decrease in the osteogenic process within the tooth sockets of rats from both cola groups, which had thinner and sparser new bone trabeculae. Histometric data confirmed that alveolar bone healing was significantly delayed in cola-fed rats at three weeks after tooth extraction (ANOVA, p = 0.0006, followed by Tukey's test, p < 0.01). Although the results of studies in rats cannot be extrapolated directly to human clinical dentistry, the present study provides evidence that cola beverage consumption negatively affect maxillary bone formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports on the crystallization of amorphous silicon (a-Si) films doped with 1 at. % of nickel. The films, with thicknesses ranging from 10 to 3000 nm, were deposited using the cosputtering method onto crystalline quartz substrates. In order to investigate the crystallization mechanism in detail, a series of undoped a-Si films prepared under the same deposition conditions were also studied. After deposition, all a-Si films were submitted to isochronal thermal annealing treatments up to 1000 degrees C and analyzed by Raman scattering spectroscopy. Based on the present experimental results, it is possible to state that (a) when compared to the undoped a-Si films, those containing 1 at. % of Ni crystallize at temperatures similar to 100 degrees C lower, and that (b) the film thickness influences the temperature of crystallization that, in principle, tends to be lower in films thinner than 1000 nm. The possible reasons associated to these experimental observations are presented and discussed in view of some experimental and thermodynamic aspects involved in the formation of ordered Si-Si bonds and in the development of Ni-silicide phases. (c) 2008 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A duplex surface treatment consisting of High Temperature Gas Nitriding (HTGN) followed by Low Temperature Plasma Nitriding (LTPN) was carried out in an UNS S31803 duplex stainless steel. The HTGN treatment was intended to produce a relatively thick and hard fully austenitic layer giving mechanical support to the thinner and much harder expanded austenite layer. HTGN was performed at 1200 degrees C for 3 h, in a 0.1 MPa N(2) atmosphere while LTPN, was carried out in a 75% N(2) + 25% H(2) atmosphere, at 400 degrees C for 12 h, under a 250 Pa pressure, and 450 V. An expanded austenite gamma(N) layer, 2.3 mu m thick, 1500 HVO.025 hard, was formed on top of a 100 mu m thick, 330 HV 0.1 hard, fully austenitic layer, containing 0.9 wt% N. For comparison purposes LTPN was carried out with UNS S30403 stainless steel specimens obtaining a 4.0 mu m thick, 1500 HV 0.025 hard, expanded austenite layer formed on top of a fully austenitic matrix having 190 HV 0.1. The nitrided specimens were tested in a 20 kHz vibratory cavitation-erosion testing equipment. Comparison between the duplex treated UNS S31803 steel and the low temperature plasma nitrided UNS S30403 steel, resulted in incubation times almost 9 times greater. The maximum cavitation wear rate of the LTPN UNS S30403 was 5.5 g/m(2)h, 180 times greater than the one measured for the duplex treated UNS S31803 steel. The greater cavitation wear resistance of the duplex treated UNS S31803 steel, compared to the LTPN treated UNS S30403 steel was explained by the greater mechanical support the fully austenitic, 330 HV 0.1 hard, 100 mu m layer gives to the expanded austenite layer formed on top of the specimen after LTPN. A strong crystallographic textured surface, inherited from the fully austenitic layer formed during HTGN, with the expanded austenite layer showing {101} crystallographic planes//surface contributed also to improve the cavitation resistance of the duplex treated steel. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The impact of the titanium nitride (TIN) gate electrode thickness has been investigated in n and p channel SOI multiple gate field effect transistors (MuGFETs) through low frequency noise charge pumping and static measurements as well as capacitance-voltage curves The results suggest that a thicker TIN metal gate electrode gives rise to a higher EOT a lower mobility and a higher interface trap density The devices have also been studied for different back gate biases where the GIFBE onset occurs at lower front-gate voltage for thinner TIN metal gate thickness and at higher V(GF) In addition it is demonstrated that post deposition nitridation of the MOCVD HfSiO gate dielectric exhibits an unexpected trend with TIN gate electrode thickness where a continuous variation of EOT and an increase on the degradation of the interface quality are observed (C) 2010 Elsevier Ltd All rights reserved

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The trapezium is often a better approximation for the FinFET cross-section shape, rather than the design-intended rectangle. The frequent width variations along the vertical direction, caused by the etching process that is used for fin definition, may imply in inclined sidewalls and the inclination angles can vary in a significant range. These geometric variations may cause some important changes in the device electrical characteristics. This work analyzes the influence of the FinFET sidewall inclination angle on some relevant parameters for analog design, such as threshold voltage, output conductance, transconductance, intrinsic voltage gain (A V), gate capacitance and unit-gain frequency, through 3D numeric simulation. The intrinsic gain is affected by alterations in transconductance and output conductance. The results show that both parameters depend on the shape, but in different ways. Transconductance depends mainly on the sidewall inclination angle and the fixed average fin width, whereas the output conductance depends mainly on the average fin width and is weakly dependent on the sidewall inclination angle. The simulation results also show that higher voltage gains are obtained for smaller average fin widths with inclination angles that correspond to inverted trapeziums, i.e. for shapes where the channel width is larger at the top than at the transistor base because of the higher attained transconductance. When the channel top is thinner than the base, the transconductance degradation affects the intrinsic voltage gain. The total gate capacitances also present behavior dependent on the sidewall angle, with higher values for inverted trapezium shapes and, as a consequence, lower unit-gain frequencies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work characterizes the analog performance of SOI n-MuGFETs with HfSiO gate dielectric and TiN metal gate with respect to the influence of the high-k post-nitridation. TiN thickness and device rotation. A thinner TiN metal gate is found favorable for improved analog characteristics showing an increase in intrinsic voltage gain. The devices where the high-k material is subjected to a nitridation step indicated a degradation of the Early voltage (V(EA)) values which resulted in a lower voltage gain. The 45 degrees rotated devices have a smaller V(EA) than the standard ones when a HfSiO dielectric is used. However, the higher transconductance of these devices, due to the increased mobility in the (1 0 0) sidewall orientation, compensates this V(EA) degradation of the voltage gain, keeping it nearly equal to the voltage gain values of the standard devices. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Congenital anomalies of the inferior vena cava (IVC) call represent a difficult for abdominal surgeries, and the radiologist must be aware even of the less common of these anatomical variations. Preaortic iliac venous confluence, also known as marsupial vena cava, is a rare congenital anomaly of the development of the IVC in which the IVC or the left common iliac vein is located anterior to the aortic bifurcation or the right common iliac artery. We report 4 cases of marsupial vena cava detected on multidetector computed tomography examinations in asymptomatic patients and discuss that this congenital anomaly can be recognized more frequently with the use of this new technique based on thinner images.