988 resultados para retention characteristics
Resumo:
The technical feasibility of utilization of fly ash as a low-cost adsorbent for the removal of metals from water has been studied. For two types of fly ashes, the retention capacities of copper, lead, and zinc metal ions have been studied. Contact time, initial concentration, and pH have been varied and their effect on retention mechanism has been studied. The dominant mechanisms responsible for retention are found to be precipitation due to the presence of calcium hydroxide, and adsorption due to the presence of silica and alumina oxide surfaces in the fly ash. First-order kinetic plots have revealed that the rate constant increases with increase in the initial concentration and pH. Langmuir adsorption isotherms have been plotted to study the maximum adsorption capacities for metal ions considered under different conditions. X-ray diffraction studies revealed the formation of new peaks corresponding to respective metal ions precipitates under alkaline conditions.
Resumo:
Soil moisture plays a cardinal role in sustaining eclological balance and agricultural development – virtually the very existence of life on earth. Because of the growing shortage of water resources, we have to use the available water most efficiently by proper management. Better utilization of rainfall or irrigation management depends largely on the water retention characteristics of the soil.Soil water retention is essential to life and it provides an ongoing supply of water to plants between periods of irrigation so as to allow their continued growth and survival.It is essential to maintain readily available water in the soil if crops are to sustain satisfactory growth. The plant growth may be retarded if the soil moisture is either deficient or excessive. The optimum moisture content is that moisture which leads to optimum growth of plant. When watering is done, the amount of water supplied should be such that the water content is equal to the field capacity that is the water remained in the saturated soil after gravitational drainage. Water will gradually be utilized consumptively by plants after the water application, and the soil moisture will start falling. When the water content in the soil reaches the value known as permanent wilting point (when the plant starts wilting) fresh dose of irrigation may be done so that water content is again raised to the field capacity of soil.Soil differ themselves in some or all the properties depending on the difference in the geotechnical and environmental factors. Soils serve as a reservoir of the nutrients and water required for crops.Study of soil and its water holding capacity is essential for the efficient utilization of irrigation water. Hence the identification of the geotechnical parameters which influence the water retention capacity, chemical properties which influence the nutrients and the method to improve these properties have vital importance in irrigation / agricultural engineering. An attempt in this direction has been made in this study by conducting the required tests on different types of soil samples collected from various locations in Trivandrum district Kerala, with and without admixtures like coir pith, coir pith compost and vermi compost. Evaluation of the results are presented and a design procedure has been proposed for a better irrigation scheduling and management.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Ferroelectric Bi3.25La0.75Ti3O12 (BLT) thin films were deposited on Pt/Ti/SiO2/Si substrates by the polymeric precursor method. The films present c-axis preferred orientation after annealing at 700 degrees C for 2 h in conventional furnace. All the capacitors showed good polarization fatigue characteristics at least up to 1x10(10) bipolar pulse cycles and excellent retention properties up to 1x10(4) s. We found that the polarization loss is insignificant with five write/read voltages at a waiting time of 10 000 S. Independently of the applied electric field the retained switchable polarization approached a nearly steady-state value after a retention time of 10 s. (C) 2005 American Institute of Physics.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Ferroelectric CaBi4Ti4O15 (CBTi144) thin films were deposited on Pt/Ti/SiO2/Si substrates by the polymeric precursor method. The films present a single phase of layered-structured perovskite with polar axis orientation after annealing at 700 degrees C for 2 h in static air and oxygen atmosphere. The a/b-axis orientation of the ferroelectric film is considered to be associated with the preferred orientation of the Pt bottom electrode. It is noted that the films annealed in static air showed good polarization fatigue characteristics at least up to 10(10) bipolar pulse cycles and excellent retention properties up to 10(4) s. on the other hand, oxygen atmosphere seems to be crucial in the decrease of both, fatigue and retention characteristics of the capacitors. Independently of the applied electric field, the retained switchable polarization approached a nearly steady-state value after a retention time of 10 s. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
This research shows that gross pollutant traps (GPTs) continue to play an important role in preventing visible street waste—gross pollutants—from contaminating the environment. The demand for these GPTs calls for stringent quality control and this research provides a foundation to rigorously examine the devices. A novel and comprehensive testing approach to examine a dry sump GPT was developed. The GPT is designed with internal screens to capture gross pollutants—organic matter and anthropogenic litter. This device has not been previously investigated. Apart from the review of GPTs and gross pollutant data, the testing approach includes four additional aspects to this research, which are: field work and an historical overview of street waste/stormwater pollution, calibration of equipment, hydrodynamic studies and gross pollutant capture/retention investigations. This work is the first comprehensive investigation of its kind and provides valuable practical information for the current research and any future work pertaining to the operations of GPTs and management of street waste in the urban environment. Gross pollutant traps—including patented and registered designs developed by industry—have specific internal configurations and hydrodynamic separation characteristics which demand individual testing and performance assessments. Stormwater devices are usually evaluated by environmental protection agencies (EPAs), professional bodies and water research centres. In the USA, the American Society of Civil Engineers (ASCE) and the Environmental Water Resource Institute (EWRI) are examples of professional and research organisations actively involved in these evaluation/verification programs. These programs largely rely on field evaluations alone that are limited in scope, mainly for cost and logistical reasons. In Australia, evaluation/verification programs of new devices in the stormwater industry are not well established. The current limitations in the evaluation methodologies of GPTs have been addressed in this research by establishing a new testing approach. This approach uses a combination of physical and theoretical models to examine in detail the hydrodynamic and capture/retention characteristics of the GPT. The physical model consisted of a 50% scale model GPT rig with screen blockages varying from 0 to 100%. This rig was placed in a 20 m flume and various inlet and outflow operating conditions were modelled on observations made during the field monitoring of GPTs. Due to infrequent cleaning, the retaining screens inside the GPTs were often observed to be blocked with organic matter. Blocked screens can radically change the hydrodynamic and gross pollutant capture/retention characteristics of a GPT as shown from this research. This research involved the use of equipment, such as acoustic Doppler velocimeters (ADVs) and dye concentration (Komori) probes, which were deployed for the first time in a dry sump GPT. Hence, it was necessary to rigorously evaluate the capability and performance of these devices, particularly in the case of the custom made Komori probes, about which little was known. The evaluation revealed that the Komori probes have a frequency response of up to 100 Hz —which is dependent upon fluid velocities—and this was adequate to measure the relevant fluctuations of dye introduced into the GPT flow domain. The outcome of this evaluation resulted in establishing methodologies for the hydrodynamic measurements and gross pollutant capture/retention experiments. The hydrodynamic measurements consisted of point-based acoustic Doppler velocimeter (ADV) measurements, flow field particle image velocimetry (PIV) capture, head loss experiments and computational fluid dynamics (CFD) simulation. The gross pollutant capture/retention experiments included the use of anthropogenic litter components, tracer dye and custom modified artificial gross pollutants. Anthropogenic litter was limited to tin cans, bottle caps and plastic bags, while the artificial pollutants consisted of 40 mm spheres with a range of four buoyancies. The hydrodynamic results led to the definition of global and local flow features. The gross pollutant capture/retention results showed that when the internal retaining screens are fully blocked, the capture/retention performance of the GPT rapidly deteriorates. The overall results showed that the GPT will operate efficiently until at least 70% of the screens are blocked, particularly at high flow rates. This important finding indicates that cleaning operations could be more effectively planned when the GPT capture/retention performance deteriorates. At lower flow rates, the capture/retention performance trends were reversed. There is little difference in the poor capture/retention performance between a fully blocked GPT and a partially filled or empty GPT with 100% screen blockages. The results also revealed that the GPT is designed with an efficient high flow bypass system to avoid upstream blockages. The capture/retention performance of the GPT at medium to high inlet flow rates is close to maximum efficiency (100%). With regard to the design appraisal of the GPT, a raised inlet offers a better capture/retention performance, particularly at lower flow rates. Further design appraisals of the GPT are recommended.
Resumo:
A novel and comprehensive testing approach to examine the performance of gross pollutant traps (GPTs) was developed. A proprietary GPT with internal screens for capturing gross pollutants—organic matter and anthropogenic litter—was used as a case study. This work is the first investigation of its kind and provides valuable practical information for the design, selection and operation of GPTs and also the management of street waste in an urban environment. It used a combination of physical and theoretical models to examine in detail the hydrodynamic and capture/retention characteristics of the GPT. The results showed that the GPT operated efficiently until at least 68% of the screens were blocked, particularly at high flow rates. At lower flow rates, the high capture/retention performance trend was reversed. It was also found that a raised inlet GPT offered a better capture/retention performance. This finding indicates that cleaning operations could be more effectively planned in conjunction with the deterioration in GPT’s capture/retention performance.
Resumo:
The majority of studies pertaining to lead retention by clays and soils have examined the mechanisms, kinetics, and adsorption isotherms using the batch experiment technique that employs solid: water extracts of 1:10 and 1:20. Field soil deposits generally have much lower gravimetric water content ranging between 9 and 45%. Given the wide disparity in the solids: water ratio employed in the batch experiment technique and that prevailing in field deposits, this paper examines the lead retention characteristics of soils at field moisture contents (6%, 13%, and 25%) using artificially lead-contaminated soil specimens. A residually derived (i.e., formed by in-situ weathering of parent rock) red soil was used to prepare the artificially contaminated soil specimens. The impact of variations in clay content on lead retention was examined by diluting the residual soil with various amounts (0 to 60%) of river sand. Soil specimens remolded at 6 and 13% moisture contents produced very stiff to hard soils on compaction, while specimens remolded at 25% moisture content existed in the slurry state. The soil specimens were contaminated with low (30mg/kg) to high (2500mg/kg) concentrations of lead ions by remolding them with 160ppm to 10,000ppm ionic lead solutions. Lead retention by soils at field moisture contents was determined by extracting the lead from the soil using a water leach test. Experimental results showed that the bulk (71 to 99%) of the added lead was retained by the soil in insoluble form at the field moisture content. Correlations between the amount of lead retained and soil/solution parameters indicated that the amounts of Pb retained at field moisture content is a function of the initial Pb addition, total sand content, effective clay porosity, and soil pH.
Resumo:
The water retention curve (WRC) is a hydraulic characteristic of concrete required for advanced modeling of water (and thus solute) transport in variably saturated, heterogeneous concrete. Unfortunately, determination by a direct experimental method (for example, measuring equilibrium moisture levels of large samples stored in constant humidity cells) is a lengthy process, taking over 2 years for large samples. A surrogate approach is presented in which the WRC is conveniently estimated from mercury intrusion porosimetry (MIP) and validated by water sorption isotherms: The well-known Barrett, Joyner and Halenda (BJH) method of estimating the pore size distribution (PSD) from the water sorption isotherm is shown to complement the PSD derived from conventional MIP. This provides a basis for predicting the complete WRC from MIP data alone. The van Genuchten equation is used to model the combined water sorption and MIP results. It is a convenient tool for describing water retention characteristics over the full moisture content range. The van Genuchten parameter estimation based solely on MIP is shown to give a satisfactory approximation to the WRC, with a simple restriction on one. of the parameters.
Resumo:
This paper presents a comprehensive review of scientific and grey literature on gross pollutant traps (GPTs). GPTs are designed with internal screens to capture gross pollutants—organic matter and anthropogenic litter. Their application involves professional societies, research organisations, local city councils, government agencies and the stormwater industry—often in partnership. In view of this, the 113 references include unpublished manuscripts from these bodies along with scientific peer-reviewed conference papers and journal articles. The literature reviewed was organised into a matrix of six main devices and nine research areas (testing methodologies) which include: design appraisal study, field monitoring/testing, experimental flow fields, gross pollutant capture/retention characteristics, residence time calculations, hydraulic head loss, screen blockages, flow visualisations and computational fluid dynamics (CFD). When the fifty-four item matrix was analysed, twenty-eight research gaps were found in the tabulated literature. It was also found that the number of research gaps increased if only the scientific literature was considered. It is hoped, that in addition to informing the research community at QUT, this literature review will also be of use to other researchers in this field.
Resumo:
The pattern of growth and development of seed crops of stylo (Stylosanthes guyanensis) was derived from measurements made on experimental and commercial crops in north Queensland. The three cultivars Cook, Endeavour, and Schofield differed appreciably only in the timetable of their development. Each had distinct successive phases of vegetative and reproductive development culminating in total annual seed production of 700-800 kg ha-1 from a healthy closed canopy, the main recorded cause of reduced production being the disease Botrytis sp. In a healthy crop of Cook, the peak quantity of standing seed represented almost 90 per cent of the total accountable seed, and the rise to and decline from this peak proceeded at rates of the order of 3-4 per cent per day. It is deduced that, although there appears to be little potential for either increase in overall production or improvement in synchronization or retention characteristics beyond that currently attained by a closed canopy of healthy plants, there is scope for an increase in the efficiency of recovery of standing seed. Maximum recovery will be achieved through attention to choice of time of harvest, presentation of a minimum amount of extraneous vegetation to the harvester, and improvement in harvester separation.
Resumo:
The soil moisture characteristic (SMC) forms an important input to mathematical models of water and solute transport in the unsaturated-soil zone. Owing to their simplicity and ease of use, texture-based regression models are commonly used to estimate the SMC from basic soil properties. In this study, the performances of six such regression models were evaluated on three soils. Moisture characteristics generated by the regression models were statistically compared with the characteristics developed independently from laboratory and in-situ retention data of the soil profiles. Results of the statistical performance evaluation, while providing useful information on the errors involved in estimating the SMC, also highlighted the importance of the nature of the data set underlying the regression models. Among the models evaluated, the one possessing an underlying data set of in-situ measurements was found to be the best estimator of the in-situ SMC for all the soils. Considerable errors arose when a textural model based on laboratory data was used to estimate the field retention characteristics of unsaturated soils.
Resumo:
We demonstrate modulations of electrical conductance and hysteresis behavior in ZnO nanowire transistors via electrically polarized switching of ferroelectric liquid crystal (FLC). After coating a nanowire channel in the transistors with FLCs, we observed large increases in channel conductance and hysteresis width, and a strong dependence of hysteresis loops on the polarization states associated with the orientation of electric dipole moments along the direction of the gate electric field. Furthermore, the reversible switching and retention characteristics provide the feasibility of creating a hybrid system with switch and memory functions. © 2013 American Institute of Physics.