743 resultados para removable appliance
Resumo:
A posterior crossbite malocclusion is defined as an abnormal buccolingual relationship. One or more maxillary teeth improperly occludes with one or more mandibular teeth in centric relation. This alteration develops early and is seldom self-correcting. This study is a report of the benefits of treating posterior crossbite malocclusions in mixed dentitions using removable appliances.
Resumo:
OBJECTIVE: The aim of this prospective study was to cephalometrically analyze the stability of dentoalveolar and skeletal changes produced by a removable appliance with palatal crib associated to high-pull chincup in individuals with anterior open bite treated for 12 months, and compare them to individuals with similar malocclusion and age, not submitted to orthodontic treatment, also followed for the same period. METHODS: Nineteen children with a mean age of 9.78 years old treated for 12 months with a removable appliance with palatal crib associated with chincup therapy were evaluated after 15 months (post-treatment period) and compared with a control group of 19 subjects with mean age of 9.10 years with the same malocclusion that was followed-up for the same period. Seventy-six lateral cephalograms were evaluated at T1 (after correction) and T2 (follow-up) and cephalometric variables were analyzed by statistical tests. RESULTS: The results did not show significant skeletal, soft tissue or maxillary dentoalveolar changes. Overall, treatment effects on the experimental group were maintained at T2 evaluation with an increase of 0.56 mm in overbite. Overjet and maxillary incisors/molars position (vertical and sagittal) remained essentially unchanged during the study period. Only mandibular incisors showed significant changes (labial inclination and protrusion) compared to control group. CONCLUSIONS: Thus, it can be concluded that the early open bite treatment with a removable appliance and palatal crib associated with high-pull chincup therapy provided stability of 95%.
Resumo:
The present report describes the management of a radicular cyst in a 5-year-old child. The treatment comprised extraction of the primary teeth involved followed by marsupialization. A removable appliance with a resin extension penetrating into the cystic cavity was used to help decompress the lesion. This treatment allowed rapid healing of the lesion and eruption of the permanent incisors without the need for orthodontic treatment.
Resumo:
Bonded maxillary expansion appliances have been suggested to control increases in the vertical dimension of the face after rapid maxillary expansion (RME). However, there is still no consensus in the literature about its real skeletal effects. The purpose of this prospective study was to evaluate, longitudinally, the vertical and sagittal cephalometric alterations after RME performed with bonded maxillary expansion appliance. The sample consisted of 26 children, with a mean age of 8.7 years (range: 6.9-10.9 years), with posterior skeletal crossbite and indication for RME. After maxillary expansion, the bonded appliance was used as a fixed retention for 3.4 months, being replaced by a removable retention subsequently. The cephalometric study was performed onto lateral radiographs, taken before treatment was started, and again 6.3 months after removing the bonded appliance. Intra-group comparison was made using paired t test. The results showed that there were no significant sagittal skeletal changes at the end of treatment. There was a small vertical skeletal increase in five of the eleven evaluated cephalometric measures. The maxilla displaced downward, but it did not modify the facial growth patterns or the direction of the mandible growth. Under the specific conditions of this research, it may be concluded that RME with acrylic bonded maxillary expansion appliance did promote signifciant vertical or sagittal cephalometric alterations. The vertical changes found with the use of the bonded appliance were small and probably transitory, similar to those occurred with the use of banded expansion appliances.
Resumo:
The purpose of this study was to differentiate the dentoalveolar and skeletal effects to better understand orthodontic treatment. We evaluated the treatment changes associated with the bionator and the removable headgear splint (RHS). Methods: The sample comprised 51 consecutively treated Class II patients from 1 office who had all been successfully treated with either a bionator (n = 17) or an RHS appliance (n = 17). Class II patients waiting to start treatment later served as controls (n = 17). A modified version of the Johnston pitchfork analysis was used to quantify the dentoalveolar and skeletal contributions to the anteroposterior correction at the levels of the molars and the incisors. Results: Both appliances significantly improved anteroposterior molar relationships (2.15 mm for the bionator, 2.27 mm for the RHS), primarily by dentoalveolar modifications (1.49 and 2.36 mm for the bionator and the RHS, respectively), with greater maxillary molar distalization in the RHS group. Overjet relationships also improved significantly compared with the controls (3.11 and 2.12 mm for the bionator and the RHS, respectively), due primarily to retroclination of the maxillary incisors (2.2 and 2.38 mm for the bionator and the RHS, respectively). The differences between overall corrections and dentoalveolar modifications for both molar and overjet relationships were explained by skeletal responses, with the bionator group showing significantly greater anterior mandibular displacement than the RHS group. Conclusions: The bionator and the RHS effectively corrected the molar relationships and overjets of Class II patients primarily by dentoalveolar changes. (Am J Orthod Dentofacial Orthop 2008; 134: 732-41)
Resumo:
INTRODUCTION: Among the sleep disorders reported by the American Academy of Sleep, the most common is obstructive sleep apnea-hypopnea syndrome (OSAHS), which is caused by difficulties in air passage and complete interruption of air flow in the airway. This syndrome is associated with increased morbidity and mortality in apneic individuals. OBJECTIVE: It was the objective of this paper to evaluate a removable mandibular advancement device as it provides a noninvasive, straightforward treatment readily accepted by patients. METHODS: In this study, 15 patients without temporomandibular disorders (TMD) and with excessive daytime sleepiness or snoring were evaluated. Data were collected by means of: Polysomnography before and after placement of an intraoral appliance, analysis of TMD signs and symptoms using a patient history questionnaire, muscle and TMJ palpation. RESULTS: After treatment, the statistical analysis (t-test, and the before and after test) showed a mean reduction of 77.6% (p=0.001) in the apnea-hypopnea index, an increase in lowest oxyhemoglobin saturation (p=0.05), decrease in desaturation (p=0.05), decrease in micro-awakenings or EEG arousals (p=0.05) and highly significant improvement in daytime sleepiness (p=0.005), measured by the Epworth Sleepiness Scale. No TMD appeared during the monitoring period. CONCLUSION: The oral device developed in this study was considered effective for mild to moderate OSAHS.
Resumo:
Objective: The aim of this prospective study was to compare the dentoalveolar effects produced by two types of palatal crib, removable (Rpc+C) and fixed (Fpc+C), combined with chincup in growing patients with anterior open bite. Material and Methods: Each group comprised 30 patients, in the mixed dentition phase, with similar cephalometric characteristics and skeletal ages. Group 1 (Rpc+ C) presented initial mean age of 8.3 years and mean anterior open bite of 4.0 mm. Group 2 (Fpc+C) presented initial mean age of 8.54 years and mean anterior open bite of 4.3 mm. The evaluation period comprised 12 months between initial (T1) and second lateral radiograph (T2). The T2-T1 changes were compared cephalometrically in the 2 groups using the non-paired t-test. Results: Vertical changes in the posterior dentoalveolar region were similar between the groups (about 1 mm) and no significant differences were found in molar mesialization. The Fpc+C group had in average 1.6 mm more improvement of the overbite as a result of greater maxillary incisor extrusion (1.3 mm). Patients in this group also presented less lingual tipping of maxillary incisors and more mandibular incisors uprighting. Conclusions: The Fpc+C combination was more efficient in the correction of the negative overbite mainly due to greater extrusion of the maxillary incisors. However, the Rpc+C appliance promoted better upper and lower incisor inclination, resulting in a more adequate overjet.
Resumo:
INTRODUCTION: Among the sleep disorders reported by the American Academy of Sleep, the most common is obstructive sleep apnea-hypopnea syndrome (OSAHS), which is caused by difficulties in air passage and complete interruption of air flow in the airway. This syndrome is associated with increased morbidity and mortality in apneic individuals. OBJECTIVE: It was the objective of this paper to evaluate a removable mandibular advancement device as it provides a noninvasive, straightforward treatment readily accepted by patients. METHODS: In this study, 15 patients without temporomandibular disorders (TMD) and with excessive daytime sleepiness or snoring were evaluated. Data were collected by means of: Polysomnography before and after placement of an intraoral appliance, analysis of TMD signs and symptoms using a patient history questionnaire, muscle and TMJ palpation. RESULTS: After treatment, the statistical analysis (t-test, and the "before and after" test) showed a mean reduction of 77.6% (p=0.001) in the apnea-hypopnea index, an increase in lowest oxyhemoglobin saturation (p=0.05), decrease in desaturation (p=0.05), decrease in micro-awakenings or EEG arousals (p=0.05) and highly significant improvement in daytime sleepiness (p=0.005), measured by the Epworth Sleepiness Scale. No TMD appeared during the monitoring period. CONCLUSION: The oral device developed in this study was considered effective for mild to moderate OSAHS.
Resumo:
Aim: To evaluate the prevalence and hygiene habits of 13-19 years-old adolescent users of removable orthodontic appliances (ROA) and to determine hygiene methods for the appliances prescribed by dentists, in the city of Pelotas. Methods: The study had two stages. The first stage was a telephone interview with dentists. Dentists were interview by telephone calls in order to obtain information regarding the hygiene methods for cleaning acrylic appliances. Second stage was a cross-sectional study performed with schoolchildren. Children from public and private schools with secondary level were included in the sample. A questionnaire was applied to the students using any type of ROA. Questionnaires included demographic information and behavioral characteristics. Data collected were subjected to Chi-square test and logistic regression. Results: The prevalence of children using ROA was 5.4%. Students (89.7%) and dentists (47.2%) reported to prefer mechanical methods to clean their ROA. Cleaning with soup, hydrogen peroxide or effervescent tabs were less used. High frequency of use was associated with higher frequency of hygiene on the ROA. Conclusions: The prevalence of schoolchildren using removable appliances was low. The common cleaning method used by children and prescribed by dentists was mechanical. Hygiene frequency was significantly associated with the routine of use of the appliance and with the type of hygiene method.
Resumo:
OBJETIVO: verificar e comparar os tipos de complicações durante o tratamento com o aparelho de Herbst com cantiléver (CBJ) e com splint removível inferior. MÉTODOS: vinte e um pacientes tratados consecutivamente com o CBJ foram comparados a vinte e um pacientes tratados consecutivamente com o aparelho de Herbst com coroas de aço nos primeiros molares superiores e com splint de acrílico inferior removível. A idade inicial média para o grupo com CBJ foi de 12 anos e 3 meses, e para o grupo com splint foi de 11 anos e 3 meses. Ambos os grupos utilizaram o aparelho por um período de 12 meses. A partir da ficha clínica dos pacientes foi realizado um levantamento de ocorrências de complicações acontecidas durante o tratamento com os aparelhos de Herbst. RESULTADOS: o número total de ocorrências de complicações foi de 24 para o grupo com CBJ e de 53 para o grupo com splint. O teste de Mann-Whitney (p<0,05) demonstrou diferença significativa entre os dois tipos de tratamento em relação ao total de ocorrências de complicações durante o tratamento. A prevalência de pacientes que apresentaram alguma complicação durante o tratamento foi de 66,67% para os pacientes tratados com CBJ, e de 85,71% para os pacientes tratados com splint. CONCLUSÕES: o grupo com CBJ apresentou menor número de complicações durante o tratamento com o aparelho de Herbst. Em ambos os grupos, nenhum paciente apresentou individualmente um grande número de complicações. O aparelho CBJ é preferível ao modelo com splint de acrílico inferior removível, devido à economia de tempo clínico e laboratorial.
Resumo:
OBJETIVO: avaliar as possíveis alterações e a estabilidade dentária e esquelética no sentido transversal, bem como as possíveis alterações verticais da face (AFAI), produzidas pela Expansão Rápida da Maxila Assistida Cirurgicamente (ERMAC). MÉTODOS: a amostra selecionada para este estudo retrospectivo foi composta por 60 telerradiografias em norma frontal, de 15 pacientes, sendo 6 do gênero masculino e 9 do gênero feminino, com média de idades de 23 anos e 3 meses. O disjuntor Hyrax foi instalado e o procedimento cirúrgico adotado envolveu a separação da sutura palatina mediana e não-abordagem da sutura pterigomaxilar. A ativação foi realizada do terceiro dias após a cirurgia até o término da expansão, determinada por critérios clínicos. Todos os pacientes foram radiografados nas fases pré-expansão (T1); pós-expansão imediata (T2); 3 meses pós-expansão, com o próprio disjuntor como contenção (T3); e 6 meses pós-expansão, com a placa removível de acrílico como contenção (T4). Medidas lineares foram obtidas a partir dos traçados cefalométricos gerados por um programa computadorizado (Radiocef Studio 2) e analisadas estatisticamente pelos testes de variância (ANOVA) e Tukey ao nível de 5% de significância. RESULTADOS E CONCLUSÕES: concluiu-se que a ERMAC produziu aumentos estatisticamente significativos da cavidade nasal, da largura maxilar e da distância intermolares superiores, de T1 para T2, os quais se mantiveram em T3 e T4. A largura facial e as distâncias intermolares inferiores não apresentaram alterações após a ERMAC. Avaliando o comportamento vertical da face, notou-se um aumento da AFAI nas fases T1 para T2, que diminuiu após a contenção de 3 meses (T3) e permaneceu estável em T4, embora aumentada se comparada com T1.
Resumo:
OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level. RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS: It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.
Resumo:
Removable partial dentures (RPD) demand specific hygienic cleaning and the combination of brushing with immersion in chemical solutions has been the most recommended method for control of biofilm. However, the effect of the cleansers on metallic components has not been widely investigated. This study evaluated the effect of different cleansers on the surface of RPD. Five disc specimens (12 mm x 3 mm metallic disc centered in a 38 x 18 x 4 mm mould filled with resin) were obtained for each experimental situation: 6 solutions [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) control] and 2 Co-Cr alloys [DeguDent (DD) and VeraPDI (VPDI)] were used for each experimental situation. A 180-day immersion was simulated and the measurements of roughness (Ra, µm) of metal and resin were analyzed using 2-way ANOVA and Tukey’s test. The surface changes and tarnishes were examined with a scanning electronic microscopy (SEM). In addition, energy dispersive x-ray spectrometry (EDS) analysis was carried out at representative areas. Visually, NaOCl and MI specimens presented surface tarnishes. The roughness of materials was not affected by the solutions (p>0.05). SEM images showed that NaOCl and MI provided surface changes. EDS analysis revealed the presence of oxygen for specimens in contact with both MI and NaOCl solutions, which might suggest that the two solutions promoted the oxidation of the surfaces, thus leading to spot corrosion. Within the limitations of this study, it may be concluded that the NaOCl and MI may not be suitable for cleaning of RPD.
Resumo:
This article reports the case of a 55-year-old female patient who presented with unsatisfactory temporary crowns in the right mandibular premolars and molars, and a premolar-to-molar fixed partial denture in the left side. The clinical and radiographic examinations revealed a fracture of the left first premolar that was a retainer of the fixed partial denture and required extraction. Initially, the acrylic resin crowns were replaced by new ones, and a provisional RPD was made using acrylic resin and orthodontic wire clasps to resolve the problem arising from the loss of the fixed partial denture. Considering the patient's high esthetic demands, the treatment options for the definitive prosthetic treatment were discussed with her and rehabilitation with implant-supported dentures was proposed because the clinical conditions of the residual alveolar ridge were suitable for implant installation, and the patient's general health was excellent. However, the patient did not agree because she knew of a failed case of implant-retained denture in a diabetic individual and was concerned. The patient was fully informed that implant installation was the best indication for her case, but the arguments were not sufficient to change her decision. The treatment possibilities were presented and the patient opted for a clasp-retained removable partial denture (RPD) associated with the placement of crowns in the pillar teeth. The temporary RPD was replaced by the definitive RPD constructed subsequently. Although RPD was not the first choice, satisfactory esthetic and functional outcomes were achieved, overcaming the patient's expectations. This case report illustrates that the dentist must be prepared to deal with situations where, for reasons that cannot be managed, the patient does not accept the treatment considered as the most indicated for his/her case. Alternatives must be proposed and the functional and esthetic requirements must be fulfilled in the best possible manner.