963 resultados para pulmonary vein
Resumo:
This study tested whether myocardial extracellular volume (ECV) is increased in patients with hypertension and atrial fibrillation (AF) undergoing pulmonary vein isolation and whether there is an association between ECV and post-procedural recurrence of AF. Hypertension is associated with myocardial fibrosis, an increase in ECV, and AF. Data linking these findings are limited. T1 measurements pre-contrast and post-contrast in a cardiac magnetic resonance (CMR) study provide a method for quantification of ECV. Consecutive patients with hypertension and recurrent AF referred for pulmonary vein isolation underwent a contrast CMR study with measurement of ECV and were followed up prospectively for a median of 18 months. The endpoint of interest was late recurrence of AF. Patients had elevated left ventricular (LV) volumes, LV mass, left atrial volumes, and increased ECV (patients with AF, 0.34 ± 0.03; healthy control patients, 0.29 ± 0.03; p < 0.001). There were positive associations between ECV and left atrial volume (r = 0.46, p < 0.01) and LV mass and a negative association between ECV and diastolic function (early mitral annular relaxation [E'], r = -0.55, p < 0.001). In the best overall multivariable model, ECV was the strongest predictor of the primary outcome of recurrent AF (hazard ratio: 1.29; 95% confidence interval: 1.15 to 1.44; p < 0.0001) and the secondary composite outcome of recurrent AF, heart failure admission, and death (hazard ratio: 1.35; 95% confidence interval: 1.21 to 1.51; p < 0.0001). Each 10% increase in ECV was associated with a 29% increased risk of recurrent AF. In patients with AF and hypertension, expansion of ECV is associated with diastolic function and left atrial remodeling and is a strong independent predictor of recurrent AF post-pulmonary vein isolation.
Resumo:
OBJECTIVE: To verify the hypothesis that the pulmonary vein pulsatility index is higher in fetuses of diabetic mothers than it is in normal fetuses of nondiabetic mothers. METHODS: Twenty-four fetuses of mothers with either gestational or previous diabetes (cases), and 25 normal fetuses of mothers without systemic disease (control) were examined. Fetuses were examined through prenatal Doppler and color flow mapping. The pulmonary vein pulsatility index was obtained by placing the pulsed Doppler sample volume over the right superior pulmonary vein and applying the formula (systolic velocity - presystolic velocity)/mean velocity. RESULTS: The mean gestational age of the study fetuses was 30.3±2.7 weeks, and gestational age of the controls was 29±3.3 weeks, with no significant difference in gestational age between groups (p=0.14). Fetuses of diabetic mothers had a mean pulmonary vein pulsatility index of 1.6±1, and those of the control group had an index of 0.86±0.27. CONCLUSION: Fetuses of diabetic mothers had pulmonary vein pulsatility indexes (parameter easily obtained through Doppler echocardiography that may be related to fetal diastolic function) higher than those in fetuses of mothers with normal glycemia.
Resumo:
Ablation strategies for the treatment of atrial fibrillation (AF) are associated with several potential complications. During electro-anatomic mapping of the left atrium (LA) before ablation, the ablation catheter was entrapped in the right inferior pulmonary vein (RIPV). After multiple unsuccessful gentle tractions, stronger maneuvers with rotation of the catheter slowly allowed its retrieval. Examination of the catheter showed a thin, translucent membrane covering its tip, suggesting complete stripping of a vein branch. Occlusion of the superior branch of the RIPV was confirmed by LA angiogram. During the following days, no pericardial effusion was noted, but the patient complained of light chest pain and mild hemoptysis, spontaneously resolving within 48 h. This case shows that catheter entrapment and mechanical disruption of a PV branch can be a rare potential complication of AF ablation. In this case, the outcome was spontaneously favorable and symptoms only included transient mild hemoptysis.
Resumo:
Background: Excessive mediastinal shift into the vacated thoracic cavity after pneumonectomy can result in dyspnea without hypoxemia by compression of the tracheobronchial tree, a phenomenon called postpneumonectomy syndrome. More rarely hypoxemia in upright position (platypnea-orthodeoxia syndrome, POS) after pneumonectomy can result from re-opening of an atrial right-to-left shunt through a patent foramen ovale (PFO) due to mediastinal distorsion. Review of literature also shows a unique report of pulmonary veins stenosis resulting in POS without intracardiac shunt after pneumonectomy. Methods: We report the case of a 32-year-old woman who presented POS 6 months after right pneumonectomy for destroyed lung post tuberculosis. Results: The patient described severe dyspnea disappearing when lying. SpO2 decreased from 94% when lying to 60% sitting. Transthoracic echocardiography (TTE) suspected a possible PFO. We first tried to highlight clinical repercussions of PFO by noninvasive exams. Hyperoxia shunt quantification was not tolerated because of increased dyspnea in sitting position. Contrast bubbles TTE was difficult because of the important mediastinal shift but identified only rare left heart bubbles with/without Valsalva both in lying and sitting position, excluding a significant right-to-left shunt. A lung perfusion scintigraphy (injection while sitting) confirmed the absence of systemic isotope uptake. Computed tomographic pulmonary angiography (angio-CT) revealed a stretched but not stenosed left main bronchus, while the shift of the heart into the right cavity was major. Pulmonary angiography did not show embolism but revealed compression of the inferior vena cava (IVC) with impaired venous return to the right heart, as well as compression of the left pulmonary veins. There was no arteriovenous shunt. Cardiac MRI showed torsion of IVC at the level of the diaphragm, and strong atrial contraction contributing to a passive filling of the RV, while the right ventricle was normal. Right catheterism showed major hemodynamic disturbances with negative diastolic pressure in right heart cavities (atrium -12 mm Hg ventricle pressure -7 mm Hg). SaO2 measured in the pulmonary artery decreased from 58% when lying to 45% sitting. Conclusion: We described here an exceedingly rare and complex mechanism explaining POS after right pneumonectomy. Mediastinal repositioning with a silicone breast implant of appropriate size has been scheduled.
Resumo:
Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set.
Resumo:
Background—Pulmonary vein stenosis (PVST) is a well-known complication of pulmonary vein isolation (PVI). Specific anatomically designed ablation catheters for antral PVI have not been evaluated with regard to the incidence of PVST. We investigated the incidence, severity, and characteristics of PVST after PVI with the Pulmonary Vein Ablation Catheter (PVAC) and phased radiofrequency technology. Methods and Results A total of 100 patients (55 men) underwent PVI for atrial fibrillation using the PVAC. PVI was guided by selective angiography of each pulmonary vein (PV) in 70 (70%) patients and by reconstructed 3D atriography (ATG) in 30 (30%) patients. Gadolinium-enhanced MRI or multidetector CT was performed in all patients before treatment and 93±78 days after PVI. PVST was classified as follows: insignificant (<25%), mild (25%–50%), moderate (50%–75%), or severe (>75%). A total of 410 PVs were analyzed. Cardiac imaging demonstrated a detectable narrowing of the PV diameter in 23 (23%) patients and in 28 (7%) PVs. In detail, insignificant PVST was observed in 12 (2.9%) PVs, mild PVST in 15 (3.7%), and moderate PVST in 1 (0.2%). No instances of severe PVST were observed. The use of 3D-ATG was associated with a lower incidence of PVST (0.8% [95% CI, 0.0%–2.2%] versus 5.4% [95% CI, 2.7%–8.1%], P=0.027). Conclusions To our knowledge, this study is the first to report the incidence of PVST using the PVAC. In this regard, the PVAC seems to be safe if used in an experienced center. In addition, the use of 3D-ATG may decrease the risk of PVST.
Resumo:
We report the clinical outcome of a 46-year-old man referred for percutaneous closure of an atrial septal defect under transthoracic echocardiographic and fluoroscopic guidance, whose upper left pulmonary vein was erroneously obliterated using an Amplatzer atrial septal defect occluder. Various medical conditions have been associated with pulmonary vein stenosis including dyspnea on exertion or at rest, cough, and hemoptysis. However, there were no short- or long-term symptoms in this patient.
Resumo:
BACKGROUND The objective of this study was to compare transtelephonic ECG every 2 days and serial 7-day Holter as two methods of follow-up after atrial fibrillation (AF) catheter ablation for the judgment of ablation success. Patients with highly symptomatic AF are increasingly treated with catheter ablation. Several methods of follow-up have been described, and judgment on ablation success often relies on patients' symptoms. However, the optimal follow-up strategy objectively detecting most of the AF recurrences is yet unclear. METHODS Thirty patients with highly symptomatic AF were selected for circumferential pulmonary vein ablation. During follow-up, a transtelephonic ECG was transmitted once every 2 days for half a year. Additionally, a 7-day Holter was recorded preablation, after ablation, after 3 and 6 months, respectively. With both, procedures symptoms and actual rhythm were correlated thoroughly. RESULTS A total of 2,600 transtelephonic ECGs were collected with 216 of them showing AF. 25% of those episodes were asymptomatic. On a Kaplan-Meier analysis 45% of the patients with paroxysmal AF were still in continuous SR after 6 months. Simulating a follow-up based on symptomatic recurrences only, that number would have increased to 70%. Using serial 7-day ECG, 113 Holter with over 18,900 hours of ECG recording were acquired. After 6 months the percentage of patients classified as free from AF was 50%. Of the patients with recurrences, 30-40% were completely asymptomatic. The percentage of asymptomatic AF episodes stepwise increased from 11% prior ablation to 53% 6 months after. CONCLUSIONS The success rate in terms of freedom from AF was 70% on a symptom-only-based follow-up; using serial 7-day Holter it decreased to 50% and on transtelephonic monitoring to 45%, respectively. Transtelephonic ECG and serial 7-day Holter were equally effective to objectively determine long-term success and to detect asymptomatic patients.
Resumo:
OBJECTIVES The aim of this study was to analyze trigger activity in the long-term follow-up after left atrial (LA) linear ablation. BACKGROUND Interventional strategies for curative treatment of atrial fibrillation (AF) are targeted at the triggers and/or the maintaining substrate. After substrate modification using nonisolating linear lesions, the activity of triggers is unknown. METHODS With the LA linear lesion concept, 129 patients were treated using intraoperative ablation with minimal invasive surgical techniques. Contiguous radiofrequency energy-induced lesion lines involving the mitral annulus and the orifices of the pulmonary veins without isolation were placed under direct vision. RESULTS After a mean follow-up of 3.6 +/- 0.4 years, atrial ectopy, atrial runs, and reoccurrence of AF episodes were analyzed by digital 7-day electrocardiograms in 30 patients. Atrial ectopy was present in all patients. Atrial runs were present in 25 of 30 patients (83%), with a median number of 9 runs per patient/week (range 1 to 321) and a median duration of 1.2 s/run (range 0.7 to 25), without a significant difference in atrial ectopy and atrial runs between patients with former paroxysmal (n = 17) or persistent AF (n = 13). Overall, 87% of all patients were completely free from AF without antiarrhythmic drugs. CONCLUSIONS A detailed rhythm analysis late after specific LA linear lesion ablation shows that trigger activity remains relatively frequent but short and does not induce AF episodes in most patients. The long-term success rate of this concept is high in patients with paroxysmal or persistent AF.
Resumo:
OBJECTIVES This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation. BACKGROUND AF/AT recurrence is common after pulmonary vein isolation (PVI). METHODS We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs. RESULTS Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred. CONCLUSIONS The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).
Resumo:
BACKGROUND Multidetector computed tomography (MDCT) may be useful to identify patients with patent foramen ovale (PFO). The aim of this study was to analyze whether a MDCT performed before pulmonary vein isolation reliably detects a PFO that may be used for access to the left atrium. METHODS AND RESULTS In 79 consecutive patients, who were referred for catheter ablation of symptomatic paroxysmal or persistent atrial fibrillation (AF), the presence of a PFO was explored by MDCT and transesophageal echocardiography (TEE). TEE was considered as the gold standard, and quality of TEE was good in all patients. In 16 patients (20.3%), MDCT could not be used for analysis because of artifacts, mainly because of AF. On TEE, a PFO was found in 15 (23.8%) of the 63 patients with usable MDCT. MDCT detected six PFO of which four were present on TEE. This corresponded to a sensitivity of 26.7%, a specificity of 95.8%, a negative predictive value of 80.7%, and a positive predictive value of 66.7%. The receiver operating characteristics curve of MDCT for the detection of PFO was 0.613 (95% confidence interval 0.493-0.732). CONCLUSIONS MDCT may detect a PFO before pulmonary isolation. However, presence of AF may lead to artifacts on MDCT impeding a meaningful analysis. Furthermore, in this study sensitivity and positive predictive value of MDCT were low and therefore MDCT was not a reliable screening tool for detection of PFO.
Resumo:
BACKGROUND Long-term success rates using ablation for persistent atrial fibrillation (AF) are disappointing and usually do not exceed 60%. OBJECTIVES This study sought to compare arrhythmia-free survival between pulmonary vein isolation (PVI) and a stepwise approach (full defrag) consisting of PVI, ablation of complex fractionated electrograms, and additional linear ablation lines in the setting of atrial tachycardias (AT) in patients with persistent AF after PVI. METHODS From November 2010 to February 2013, 205 patients (151 men; 61.7 ± 10.2 years of age) underwent de novo ablation for persistent AF. Subsequently, patients were prospectively randomized to either PVI alone (n = 78) or full defrag (n = 75), with 52 patients not randomized due to AF termination with the original PVI. The primary endpoint was recurrence of any AT after a blanking period of 3 months. RESULTS During the entire study, 241 ablations were performed (mean: 1.59 in the PVI-alone group, 1.55 in the full-defrag group). With the stepwise approach, termination of AF occurred in 45 (60%) patients. However, arrhythmia-free survival did not differ whether patients underwent single or multiple procedures (p = 0.468). Procedure duration, fluoroscopy time, and radiofrequency duration were significantly longer in the full-defrag group (all p < 0.001). CONCLUSIONS A stepwise approach aimed at AF termination does not seem to provide additional benefit over PVI alone in patients with persistent AF, but it is associated with significantly longer procedural and fluoroscopic duration as well as radiofrequency application time. (The Randomized Catheter Ablation of Persist End Atrial Fibrillation Study [CHASE-AF]; NCT01580124).