989 resultados para positive pressure ventilation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare the effects of 3 types of noninvasive respiratory support systems in the treatment of acute pulmonary edema: oxygen therapy (O2), continuous positive airway pressure, and bilevel positive pressure ventilation. METHODS: We studied prospectively 26 patients with acute pulmonary edema, who were randomized into 1 of 3 types of respiratory support groups. Age was 69±7 years. Ten patients were treated with oxygen, 9 with continuous positive airway pressure, and 7 with noninvasive bilevel positive pressure ventilation. All patients received medicamentous therapy according to the Advanced Cardiac Life Support protocol. Our primary aim was to assess the need for orotracheal intubation. We also assessed the following: heart and respiration rates, blood pressure, PaO2, PaCO2, and pH at begining, and at 10 and 60 minutes after starting the protocol. RESULTS: At 10 minutes, the patients in the bilevel positive pressure ventilation group had the highest PaO2 and the lowest respiration rates; the patients in the O2 group had the highest PaCO2 and the lowest pH (p<0.05). Four patients in the O2 group, 3 patients in the continuous positive pressure group, and none in the bilevel positive pressure ventilation group were intubated (p<0.05). CONCLUSION: Noninvasive bilevel positive pressure ventilation was effective in the treatment of acute cardiogenic pulmonary edema, accelerated the recovery of vital signs and blood gas data, and avoided intubation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Positive pressure ventilation (PPV) is a frequent intervention in the neonatal intensive care unit. This article is directed towards paediatricians in training and attempts to cover the basics of PPV without being too technical. To do so we have employed an extensive use of graphics to illustrate the underlying principles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To describe noninvasive positive-pressure ventilation use in intensive care unit clinical practice, factors associated with NPPV failure and the associated prognosis. METHODS: A prospective cohort study. RESULTS: Medical disorders (59%) and elective surgery (21%) were the main causes for admission to the intensive care unit. The main indications for the initiation of noninvasive positive-pressure ventilation were the following: post-extubation, acute respiratory failure and use as an adjunctive technique to chest physiotherapy. The noninvasive positive-pressure ventilation failure group was older and had a higher Simplified Acute Physiology Score II score. The noninvasive positive-pressure ventilation failure rate was 35%. The main reasons for intubation were acute respiratory failure (55%) and a decreased level of consciousness (20%). The noninvasive positive-pressure ventilation failure group presented a shorter period of noninvasive positive-pressure ventilation use than the successful group [three (2-5) versus four (3-7) days]; they had lower levels of pH, HCO3 and base excess, and the FiO(2) level was higher. These patients also presented lower PaO2:FiO2 ratios; on the last day of support, the inspiratory positive airway pressure and expiratory positive airway pressure were higher. The failure group also had a longer average duration of stay in the intensive care unit [17 (10-26) days vs. 8 (5-14) days], as well as a higher mortality rate (9 vs. 51%). There was an association between failure and mortality, which had an odds ratio (95% CI) of 10.6 (5.93 - 19.07). The multiple logistic regression analysis using noninvasive positive pressure ventilation failure as a dependent variable found that treatment tended to fail in patients with a Simplified Acute Physiology Score II >= 34, an inspiratory positive airway pressure level >= 15 cmH2O and pH<7.40. CONCLUSION: The indications for noninvasive positive-pressure ventilation were quite varied. The failure group had a longer intensive care unit stay and higher mortality. Simplified Acute Physiology Score II >= 34, pH<7.40 and higher inspiratory positive airway pressure levels were associated with failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To investigate the use of nasal intermittent positive pressure ventilation (NIPPV) in level three neonatal intensive care units (NICU) in northeastern Brazil. Methods: This observational cross-sectional survey was conducted from March 2009 to January 2010 in all level three NICUs in northeastern Brazil that are registered in the Brazilian Registry of Health Establishments (Cadastro Nacional de Estabelecimentos de Saude, CNES) of the Ministry of Health. Questionnaires about the use of NIPPV were sent to the NICU directors in each institution. Statistical analysis was conducted using the software Epi-Info 6.04 and double data entry. A chi-square test was used to compare variables, and the level of statistical significance was set at p <= 0.05. Results: This study identified 93 level three NICUs in northeastern Brazil registered in CNES, and 87% answered the study questionnaire. Most classified themselves as private institutions (30.7%); 98.7% used NIPPV; 92.8 % adapted mechanical ventilators for NIPPV and used short binasal prongs as the interface (94.2%). Only 17.3% of the units had a protocol for the use of NIPPV. Mean positive inspiratory pressure and positive end-expiratory pressure were 20.0 cmH(2)O (standard deviation [SD]: 4.47) and 5.0 cmH(2)O (SD: 0.84). Conclusion: NICUs in northeastern Brazil use nasal intermittent positive pressure ventilation, but indications and ventilation settings are not the same in the different institutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and objective: Dynamic indices represented by systolic pressure variation and pulse pressure variation have been demonstrated to be more accurate than filling pressures in predicting fluid responsiveness. However, the literature is scarce concerning the impact of different ventilatory modes on these indices. We hypothesized that systolic pressure variation or pulse pressure variation could be affected differently by volume-controlled ventilation and pressure-controlled ventilation in an experimental model, during normovolaemia and hypovolaemia. Method: Thirty-two anaesthetized rabbits were randomly allocated into four groups according to ventilatory modality and volaemic status where G1-ConPCV was the pressure-controlled ventilation control group, G2-HemPCV was associated with haemorrhage, G3-ConVCV was the volume-controlled ventilation control group and G4-HemVCV was associated with haemorrhage. In the haemorrhage groups, blood was removed in two stages: 15% of the estimated blood volume withdrawal at M1, and, 30 min later, an additional 15% at M2. Data were submitted to analysis of variance for repeated measures; a value of P < 0.05 was considered to be statistically significant. Results: At MO (baseline), no significant differences were observed among groups. At M1, dynamic parameters differed significantly among the control and hypovolaemic groups (P < 0.05) but not between ventilation modes. However, when 30% of the estimated blood volume was removed (M2), dynamic parameters became significantly higher in animals under volume-controlled ventilation when compared with those under pressure-controlled ventilation. Conclusions: Under normovolaemia and moderate haemorrhage, dynamic parameters were not influenced by either ventilatory modalities. However, in the second stage of haemorrhage (30%), animals in volume-controlled ventilation presented higher values of systolic pressure variation and pulse pressure variation when compared with those submitted to pressure-controlled ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Acquired immunodeficiency syndrome (AIDS) is a pandemic disease commonly associated with respiratory infections, hypoxemia, and death. Noninvasive PEEP has been shown to improve hypoxemia. In this study, we evaluated the physiologic effects of different levels of noninvasive PEEP in hypoxemic AIDS patients. METHODS: Thirty AIDS patients with acute hypoxemic respiratory failure received a randomized sequence of noninvasive PEEP (5, 10, or 15 cm H2O) for 20 min. PEEP was provided through a facial mask with pressure-support ventilation (PSV) of 5 cm H2O and an F-IO2, of 1. Patients were allowed to breathe spontaneously for a 20-min washout period in between each PEEP trial. Arterial blood gases and clinical variables were recorded after each PEEP treatment. RESULTS: The results indicate that oxygenation improves linearly with increasing levels of PEEP. However, oxygenation levels were similar regardless of the first PEEP level administered (5, 10, or 15 cm H2O), and only the subgroup that received an initial treatment of the lowest level of PEEP (ie, 5 cm H2O) showed further improvements in oxygenation when higher PEEP levels were subsequently applied. The P-aCO2, also increased in response to PEEP elevation, especially with the highest level of PEEP (ie, 15 cm H2O). PSV of 5 cm H2O use was associated with significant and consistent improvements in the subjective sensations of dyspnea and respiratory rate reported by patients treated with any level of PEEP (from 0 to 15 cm H2O). CONCLUSIONS: AIDS patients with hypoxemic respiratory failure improve oxygenation in response to a progressive sequential elevation of PEEP (up to 15 cm H2O). However, corresponding elevations in P-aCO2, limit the recommended level of PEEP to 10 cm H2O. At a level of 5 cm H2O, PSV promotes an improvement in the subjective sensation of dyspnea regardless of the PEEP level employed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Noninvasive positive-pressure ventilation (NPPV) modes are currently available on bilevel and ICU ventilators. However, little data comparing the performance of the NPPV modes on these ventilators are available. Methods: In an experimental bench study, the ability of nine ICU ventilators to function in the presence of leaks was compared with a bilevel ventilator using the IngMar ASL5000 lung simulator (IngMar Medical; Pittsburgh, PA) set at a compliance of 60 mL/cm H(2)O, an inspiratory resistance of 10 cm H(2)O/L/s, an expiratory resistance of 20 cm H(2)O/L/s, and a respiratory rate of 15 breaths/min. All of the ventilators were set at 12 cm H(2)O pressure support and 5 cm H(2)O positive end-expiratory pressure. The data were collected at baseline and at three customized leaks. Main results: At baseline, all of the ventilators were able to deliver adequate tidal volumes, to maintain airway pressure, and to synchronize with the simulator, without missed efforts or auto-triggering. As the leak was increased, all of the ventilators (except the Vision [Respironics; Murrysville, PA] and Servo I [Maquet; Solna, Sweden]) needed adjustment of sensitivity or cycling criteria to maintain adequate ventilation, and some transitioned to backup ventilation. Significant differences in triggering and cycling were observed between the Servo I and the Vision ventilators. Conclusions: The Vision and Servo I were the only ventilators that required no adjustments as they adapted to increasing leaks. There were differences in performance between these two ventilators, although the clinical significance of these differences is unclear. Clinicians should be aware that in the presence of leaks, most ICU ventilators require adjustments to maintain an adequate tidal volume. (CHEST 2009; 136:448-456)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the use of high frequency jet ventilation (HFJV) in patients undergoing percutanous thermal ablation procedures.Materials: From may to september 2011 patients with lung, liver or kidney tumors suitable for percutanous thermal ablation were prospectively enrolled to be treated under general anesthesia using HFJV instead of conventional positive pressure ventilation (PPV). Our primary endpoint was feasability of HFJV during percutanous ablation, our secondary endpoints were assessment of breathing related movements by image fusion (CT/US), precision and ease of needle placement by number of CT aquisition/needle reposition and procedure related complications.Results: Twenty-nine patients (21 males, 8 females mean age 66.2 years) with 30 liver tumors, 1 kidney tumors and 6 lung tumors were included. Tumor ablation was performed by radiofrequency (RFA) in 26 cases, microwaves ( MWA) in 2 and cryoablation (CRA) in 1. The ablation procedure could be completed under HFJV in 22 patients. In 2 patients HFVJ had to be stopped in favor of PPV because the tumor was better seen under PPV. HFJV was not performed in 5. Breathing related movements of the target lesion in the cranio-caudal direction as estimated by image fusion were always inferior to 5mm compared to 20mm when patients are under PPV. Needle placement was straightforward under CT as well as US. No patient needed needle repositionning before ablation. We did not observe any HFJV related complications.Conclusions: HFJV significantly reduces breathing movements of target lesion during percutaneous ablation procedures. It does not seem to cause any particular complication. However in some cases such as tumors located at the base of the lungs or in the dome of the liver, the target may be best seen under PPV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Spontaneous ventilation, mechanical controlled ventilation, apneic intermittent ventilation, and jet ventilation are commonly used during interventional suspension microlaryngoscopy. The aim of this study was to investigate specific complications of each technique, with special emphasis on transtracheal and transglottal jet ventilation. METHODS: The authors performed a retrospective single-institution analysis of a case series of 1,093 microlaryngoscopies performed in 661 patients between January 1994 and January 2004. Data were collected from two separate prospective databases. Feasibility and complications encountered with each technique of ventilation were analyzed as main outcome measures. RESULTS: During 1,093 suspension microlaryngoscopies, ventilation was supplied by mechanical controlled ventilation via small endotracheal tubes (n = 200), intermittent apneic ventilation (n = 159), transtracheal jet ventilation (n = 265), or transglottal jet ventilation (n = 469). Twenty-nine minor and 4 major complications occurred. Seventy-five percent of the patients with major events had an American Society of Anesthesiologists physical status classification of III. Five laryngospasms were observed with apneic intermittent ventilation. All other 24 complications (including 7 barotrauma) occurred during jet ventilation. Transtracheal jet ventilation was associated with a significantly higher complication rate than transglottal jet ventilation (P < 0.0001; odds ratio, 4.3 [95% confidence interval, 1.9-10.0]). All severe complications were related to barotraumas resulting from airway outflow obstruction during jet ventilation, most often laryngospasms. CONCLUSIONS: The use of a transtracheal cannula was the major independent risk factor for complications during jet ventilation for interventional microlaryngoscopy. The anesthetist's vigilance in clinically detecting and preventing outflow airway obstruction remains the best prevention of barotrauma during subglottic jet ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Optimal high-intensity interval training (HIIT) regimens for running performance are unknown, although most protocols result in some benefit to key performance factors (running economy (RE), anaerobic threshold (AT), or maximal oxygen uptake (V˙O2max)). Lower-body positive pressure (LBPP) treadmills offer the unique possibility to partially unload runners and reach supramaximal speeds. We studied the use of LBPP to test an overspeed HIIT protocol in trained runners. METHODS: Eleven trained runners (35 ± 8 yr, V˙O2max, 55.7 ± 6.4 mL·kg·min) were randomized to an LBPP (n = 6) or a regular treadmill (CON, n = 5), eight sessions over 4 wk of HIIT program. Four to five intervals were run at 100% of velocity at V˙O2max (vV˙O2max) during 60% of time to exhaustion at vV˙O2max (Tlim) with a 1:1 work:recovery ratio. Performance outcomes were 2-mile track time trial, V˙O2max, vV˙O2max, vAT, Tlim, and RE. LBPP sessions were carried out at 90% body weight. RESULTS: Group-time effects were present for vV˙O2max (CON, 17.5 vs. 18.3, P = 0.03; LBPP, 19.7 vs. 22.3 km·h; P < 0.001) and Tlim (CON, 307.0 vs. 404.4 s, P = 0.28; LBPP, 444.5 vs. 855.5, P < 0.001). Simple main effects for time were present for field performance (CON, -18; LBPP, -25 s; P = 0.002), V˙O2max (CON, 57.6 vs. 59.6; LBPP, 54.1 vs. 55.1 mL·kg·min; P = 0.04) and submaximal HR (157.7 vs. 154.3 and 151.4 vs. 148.5 bpm; P = 0.002). RE was unchanged. CONCLUSIONS: A 4-wk HIIT protocol at 100% vV˙O2max improves field performance, vV˙O2max, V˙O2max and submaximal HR in trained runners. Improvements are similar if intervals are run on a regular treadmill or at higher speeds on a LPBB treadmill with 10% body weight reduction. LBPP could provide an alternative for taxing HIIT sessions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of 2 different levels of the inspired oxygen fraction (FiO(2)) on blood gas variables was evaluated in dogs with high intracranial pressure (ICP) during propofol anesthesia (induction followed by a continuous rate infusion [CRI] of 0.6 mg/kg/min) and intermittent positive pressure ventilation (IPPV). Eight adult mongrel dogs were anesthetized on 2 occasions, 21 d apart, and received oxygen at an FiO(2) of 1.0 (G100) or 0.6 (G60) in a randomized crossover fashion. A fiberoptic catheter was implanted on the surface of the right cerebral cortex for assessment of the ICP. An increase in the ICP was induced by temporary ligation of the jugular vein 50 min after induction of anesthesia and immediately after baseline measurement of the ICP. Blood gas measurements were taken 20 min later and then at 15-min intervals for 1 h. Numerical data were submitted to Morrison's multivariate statistical methods. The ICP, the cerebral perfusion pressure and the mean arterial pressure did not differ significantly between FiO(2) levels or measurement times after jugular ligation. The only blood gas values that differed significantly (P < 0.05) were the arterial oxygen partial pressure, which was greater with G100 than with G60 throughout the procedure, and the venous haemoglobin saturation, that was greater with G100 than with G60 at M0. There were no significant differences between FiO(2) levels or measurement times in the following blood gas variables: arterial carbon dioxide partial pressure, arterial hemoglobin saturation, base deficit, bicarbonate concentration, pH, venous oxygen partial pressure, venous carbon dioxide partial pressure and the arterial-to-end-tidal carbon dioxide difference.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The effectiveness of noninvasive positive-pressure ventilation in preventing reintubation due to respiratory failure in children remains uncertain. A pilot study was designed to evaluate the frequency of extubation failure, develop a randomization approach, and analyze the feasibility of a powered randomized trial to compare noninvasive positive-pressure ventilation and standard oxygen therapy post extubation for preventing reintubation within 48 hours in children with respiratory failure.Design: Prospective pilot study.Setting: PICU at a university-affiliated hospital.Patients: Children aged between 28 days and 3 years undergoing invasive mechanical ventilation for greater than or equal to 48 hours with respiratory failure after programmed extubation.Interventions: Patients were prospectively enrolled and randomly assigned into noninvasive positive-pressure ventilation group and inhaled oxygen group after programmed extubation from May 2012 to May 2013.Measurements and Main Results: Length of stay in PICU and hospital, oxygenation index, blood gas before and after tracheal extubation, failure and reason for tracheal extubation, complications, mechanical ventilation variables before tracheal extubation, arterial blood gas, and respiratory and heart rates before and 1 hour after tracheal extubation were analyzed. One hundred eight patients were included (noninvasive positive-pressure ventilation group, n = 55 and inhaled oxygen group, n = 53), with 66 exclusions. Groups did not significantly differ for gender, age, disease severity, Pediatric Risk of Mortality at admission, tracheal intubation, and mechanical ventilation indications. There was no statistically significant difference in reintubation rate (noninvasive positive-pressure ventilation group, 9.1%; inhaled oxygen group, 11.3%; p > 0.05) and length of stay (days) in PICU (noninvasive positive-pressure ventilation group, 3 [116]; inhaled oxygen group, 2 [1-25]; p > 0.05) or hospital (noninvasive positive-pressure ventilation group, 19 [7-141]; inhaled oxygen group, 17 [8-80]).Conclusions: The study indicates that a larger randomized trial comparing noninvasive positive-pressure ventilation and standard oxygen therapy in children with respiratory failure is feasible, providing a basis for a future trial in this setting. No differences were seen between groups. The number of excluded patients was high.