907 resultados para portable device


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Portland cement concrete (PCC) pavement undergoes repeated environmental load-related deflection resulting from temperature and moisture variations across pavement depth. This has been recognized as resulting in PCC pavement curling and warping since the mid-1920s. Slab curvature can be further magnified under repeated traffic loads and may ultimately lead to fatigue failures, including top-down and bottom-up transverse, longitudinal, and corner cracking. It is therefore significant to measure the “true” degree of curling and warping in PCC pavements, not only for quality control (QC) and quality assurance (QA) purposes, but also for better understanding of its relationship to long-term pavement performance. Although several approaches and devices—including linear variable differential transducers (LVDTs), digital indicators, and some profilers—have been proposed for measuring curling and warping, their application in the field is subject to cost, inconvenience, and complexity of operation. This research therefore explores developing an economical and simple device for measuring curling and warping in concrete pavements with accuracy comparable to or better than existing methodologies. Technical requirements were identified to establish assessment criteria for development, and field tests were conducted to modify the device to further enhancement. The finalized device is about 12 inches in height and 18 pounds in weight, and its manufacturing cost is just $320. Detailed development procedures and evaluation results for the new curling and warping measuring device are presented and discussed, with a focus on achieving reliable curling and warping measurements in a cost effective manner.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Blood typing is a crucial step before any blood transfusion. However, sometimes in emergency situations there is no time to determine the blood of the patient beforehand. In this cases, O negative blood type is administered, which has a lesser incompatibility risk to the patient. Nowadays, the “gold standard” blood typing devices cannot be used in emergency situations due to their high response time (about 30 minutes). This paper reports a blood typing device that determines the ABO and Rh human phenotypes. This device is fast (response time – 5 min), low-cost, and portable. Characteristics that make it suitable to be used in emergency situations, contributing to a higher efficiency and quality in healthcare.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: This article describes the application and the performance of a cheap, simple and portable device that can be used for colorimetric quantitative determination of captopril (CPT) in pharmaceutical preparations. Methods: The sensor is a light detector resistor (LDR) placed into a black PTFE cell and coupled to a low cost multimeter (Ohmmeter). The instrument has been tested and is easy and fast to use. The quantitative study is based mainly on reduction of ammonium molybdate by captopril, in the presence of sulphuric acid, producing a green-yellow compound (max 407 nm). The calibration curves were obtained by plotting the electric resistance of the LDR against the CPT concentration on the range of 4.60 x 10-4 to 1.84 x 10-3 mol l-1 with a good coefficient of determination (R2 = 0.9962). Results: Statistical analysis of the obtained results showed no significant difference between the proposed methodology and the official reported method as evident from the t-test and variance ratio at 95% confidence level. Conclusion: The results of this study demonstrate that the instrument can be used for simple, accurate, precise, fast, in situ and low-cost colorimetric analysis of captopril in pharmaceuticals products.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Abstract Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis proposes design methods and test tools, for optical systems, which may be used in an industrial environment, where not only precision and reliability but also ease of use is important. The approach to the problem has been conceived to be as general as possible, although in the present work, the design of a portable device for automatic identification applications has been studied, because this doctorate has been funded by Datalogic Scanning Group s.r.l., a world-class producer of barcode readers. The main functional components of the complete device are: electro-optical imaging, illumination and pattern generator systems. For what concerns the electro-optical imaging system, a characterization tool and an analysis one has been developed to check if the desired performance of the system has been achieved. Moreover, two design tools for optimizing the imaging system have been implemented. The first optimizes just the core of the system, the optical part, improving its performance ignoring all other contributions and generating a good starting point for the optimization of the whole complex system. The second tool optimizes the system taking into account its behavior with a model as near as possible to reality including optics, electronics and detection. For what concerns the illumination and the pattern generator systems, two tools have been implemented. The first allows the design of free-form lenses described by an arbitrary analytical function exited by an incoherent source and is able to provide custom illumination conditions for all kind of applications. The second tool consists of a new method to design Diffractive Optical Elements excited by a coherent source for large pattern angles using the Iterative Fourier Transform Algorithm. Validation of the design tools has been obtained, whenever possible, comparing the performance of the designed systems with those of fabricated prototypes. In other cases simulations have been used.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In the Institute of Cybernetics of National Academy of Sciences of Ukraine the smart portable fluorometer for express-diagnostics of photosynthesis was designed. The device allows easy to estimate the level of influence of natural environment and pollutions to alive plants. The device is based on real time processing of the curve of chlorophyll fluorescent induction. The principles of operation and results of experimental researches of device are described in the article.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In the V.M. Glushov Institute of Cybernetics of National Academy of Sciences of Ukraine in collaboration with O.V. Palladin’s Institute of Biochemistry of National Academy of Sciences of Ukraine the smart portable device for express-diagnostics of acute viral infections, including bird flu, is designed. The device is based on the effect of surface plasmon resonance. The principles of device are described in the article.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: NovoTTF-100A is a portable device delivering low-intensity, intermediate frequency electric fields via non-invasive, transducer arrays. Tumour Treatment Fields (TTF), a completely new therapeutic modality in cancer treatment, physically interfere with cell division. METHODS: Phase III trial of chemotherapy-free treatment of NovoTTF (20-24h/day) versus active chemotherapy in the treatment of patients with recurrent glioblastoma. Primary end-point was improvement of overall survival. RESULTS: Patients (median age 54years (range 23-80), Karnofsky performance status 80% (range 50-100) were randomised to TTF alone (n=120) or active chemotherapy control (n=117). Number of prior treatments was two (range 1-6). Median survival was 6.6 versus 6.0months (hazard ratio 0.86 [95% CI 0.66-1.12]; p=0.27), 1-year survival rate was 20% and 20%, progression-free survival rate at 6months was 21.4% and 15.1% (p=0.13), respectively in TTF and active control patients. Responses were more common in the TTF arm (14% versus 9.6%, p=0.19). The TTF-related adverse events were mild (14%) to moderate (2%) skin rash beneath the transducer arrays. Severe adverse events occurred in 6% and 16% (p=0.022) of patients treated with TTF and chemotherapy, respectively. Quality of life analyses favoured TTF therapy in most domains. CONCLUSIONS: This is the first controlled trial evaluating an entirely novel cancer treatment modality delivering electric fields rather than chemotherapy. No improvement in overall survival was demonstrated, however efficacy and activity with this chemotherapy-free treatment device appears comparable to chemotherapy regimens that are commonly used for recurrent glioblastoma. Toxicity and quality of life clearly favoured TTF.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

NovoTTF-100A (TTF) is a portable device delivering low-intensity, intermediate-frequency, alternating electric fields using noninvasive, disposable scalp electrodes. TTF interferes with tumor cell division, and it has been approved by the US Food and Drug Administration (FDA) for the treatment of recurrent glioblastoma (rGBM) based on data from a phase III trial. This presentation describes the updated survival data 2 years after completing recruitment. Adults with rGBM (KPS ≥ 70) were randomized (stratified by surgery and center) to either continuous TTF (20-24 h/day, 7 days/week) or efficacious chemotherapy based on best physician choice (BPC). The primary endpoint was overall survival (OS), and secondary endpoints were PFS6, 1-year survival, and QOL. Patients were randomized (28 US and European centers) to either TTF alone (n ¼ 120) or BPC (n ¼ 117). Patient characteristics were balanced, median age was 54 years (range, 23-80 years), and median KPS was 80 (range, 50-100). One quarter of the patients had debulking surgery, and over half of the patients were at their second or later recurrence. OS in the intent-to-treat (ITT) population was equivalent in TTF versus BPC patients (median OS, 6.6vs. 6.0 months; n ¼ 237; p ¼ 0.26; HR ¼ 0.86). With a median follow-up of 33.6 months, long-term survival in the TTF group was higher than that in the BPC group at 2, 3, and 4 years of follow-up (9.3% vs. 6.6%; 8.4% vs. 1.4%; 8.4% vs. 0.0%, respectively). Analysis of patients who received at least one treatment course demonstrated a survival benefit for TTF patients compared to BPC patients (median OS, 7.8 vs. 6.0 months; n ¼ 93 vs. n ¼ 117; p ¼ 0.012; HR ¼ 0.69). In this group, 1-year survival was 28% vs. 20%, and PFS6 was 26.2% vs. 15.2% (p ¼ 0.034). TTF, a noninvasive, novel cancer treatment modality shows significant therapeutic efficacy with promising long-term survival results. The impact of TTF was more pronounced when comparing only patients who received the minimal treatment course. A large-scale phase III trial in newly diagnosed GBM is ongoing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: NovoTTF is a portable device delivering low-intensity, intermediate-frequency, electric fields using noninvasive, disposable scalp electrodes. These fields physically interfere with cell division. Preliminary studies in recurrent and newly diagnosed glioblastoma (GBM) have shown promising results. A phase III study in recurrent GBM has recently been concluded. METHODS: Adults (KPS ≥ 70%) with recurrent GBM (any recurrence) were randomized (stratified by surgery and center) to either NovoTTF administered continuously (20-24 hours/day, 7 days/week) or the best available chemotherapy (best physician choice [BPC]). Primary endpoint was overall survival (OS); 6-month progression-free survival (PFS6), 1-year survival, and QOL were secondary endpoints. RESULTS: Two hundred thirty-seven patients were randomized (28 centers in the United States and Europe) to either NovoTTF alone (120 patients) or BPC (117 patients). Patient characteristics were balanced, median age was 54 years (range, 23-80 years), median KPS was 80% (range, 50-100). One quarter had surgery for recurrence, and over half were at their second or more recurrence. A survival advantage for the device group was seen in patients treated according to protocol (median OS, 7.8 months vs. 6.1 months; n = 185; p = 0.01). Moreover, subgroup analysis in patients with better prognostic baseline characteristics (KPS ≥ 80%; age ≤ 60; 1st-3rd recurrence) demonstrated a robust survival benefit for NovoTTF patients compared to matched BPC patients (median OS, 8.8 months vs. 6.6 months; n = 110; p < 0.01). In this group, 1-year survival was 35% vs. 20% and PFS6 was 25.6% vs. 7.7%. Interestingly, in patients who failed bevacizumab prior to the trial, OS was also significantly extended by NovoTTF (4.4 months vs. 3.1 months; n = 23 vs. n = 21; p < 0.02). Quality of life was equivalent or superior in NovoTTF patients. CONCLUSIONS: NovoTTF, a noninvasive, novel cancer treatment modality shows significant therapeutic efficacy with improved quality of life. The impact of NovoTTF was more pronounced when patients with better baseline prognostic factors were treated. A large scale phase III clinical trial in newly diagnosed GBM is currently being conducted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La lecture numérique prend de plus en plus de place dans l'espace global de la lecture des étudiants. Bien que les premiers systèmes de lecture numérique, communément appelés livres électroniques, datent déjà de plusieurs années, les opinions quant à leur potentiel divergent encore. Une variété de contenus universitaires numériques s’offre aujourd’hui aux étudiants, entraînant par le fait même une multiplication d'usages ainsi qu'une variété de modes de lecture. Les systèmes de lecture numérique font maintenant partie intégrante de l’environnement électronique auquel les étudiants ont accès et méritent d’être étudiés plus en profondeur. Maintes expérimentations ont été menées dans des bibliothèques publiques et dans des bibliothèques universitaires sur les livres électroniques. Des recherches ont été conduites sur leur utilisabilité et sur le degré de satisfaction des lecteurs dans le but d’en améliorer le design. Cependant, très peu d’études ont porté sur les pratiques de lecture proprement dites des universitaires (notamment les étudiants) et sur leurs perceptions de ces nouveaux systèmes de lecture. Notre recherche s’intéresse à ces aspects en étudiant deux systèmes de lecture numérique, une Tablet PC (dispositif nomade) et un système de livres-Web, NetLibrary (interface de lecture intégrée à un navigateur Web). Notre recherche étudie les pratiques de lecture des étudiants sur ces systèmes de lecture numérique. Elle est guidée par trois questions de recherche qui s’articulent autour (1) des stratégies de lecture employées par des étudiants (avant, pendant et après la lecture), (2) des éléments du système de lecture qui influencent (positivement ou négativement) le processus de lecture et (3) des perceptions des étudiants vis-à-vis la technologie du livre électronique et son apport à leur travail universitaire. Pour mener cette recherche, une approche méthodologique mixte a été retenue, utilisant trois modes de collecte de données : un questionnaire, des entrevues semi-structurées avec les étudiants ayant utilisé l’un ou l’autre des systèmes étudiés, et le prélèvement des traces de lecture laissées par les étudiants dans les systèmes, après usage. Les répondants (n=46) étaient des étudiants de l’Université de Montréal, provenant de trois départements (Bibliothéconomie & sciences de l’information, Communication et Linguistique & traduction). Près de la moitié d’entre eux (n=21) ont été interviewés. Parallèlement, les traces de lecture laissées dans les systèmes de lecture par les étudiants (annotations, surlignages, etc.) ont été prélevées et analysées. Les données des entrevues et des réponses aux questions ouvertes du questionnaire ont fait l'objet d'une analyse de contenu et un traitement statistique a été réservé aux données des questions fermées du questionnaire et des traces de lecture. Les résultats obtenus montrent que, d’une façon générale, l’objectif de lecture, la nouveauté du contenu, les habitudes de lecture de l’étudiant de même que les possibilités du système de lecture sont les éléments qui orientent le choix et l’application des stratégies de lecture. Des aides et des obstacles à la lecture ont été identifiés pour chacun des systèmes de lecture étudiés. Les aides consistent en la présence de certains éléments de la métaphore du livre papier dans le système de lecture numérique (notion de page délimitée, pagination, etc.), le dictionnaire intégré au système, et le fait que les systèmes de lecture étudiés facilitent la lecture en diagonale. Pour les obstacles, l’instrumentation de la lecture a rendu l’appropriation du texte par le lecteur difficile. De plus, la lecture numérique (donc « sur écran ») a entraîné un manque de concentration et une fatigue visuelle notamment avec NetLibrary. La Tablet PC, tout comme NetLibrary, a été perçue comme facile à utiliser mais pas toujours confortable, l’inconfort étant davantage manifeste dans NetLibrary. Les étudiants considèrent les deux systèmes de lecture comme des outils pratiques pour le travail universitaire, mais pour des raisons différentes, spécifiques à chaque système. L’évaluation globale de l’expérience de lecture numérique des répondants s’est avérée, dans l’ensemble, positive pour la Tablet PC et plutôt mitigée pour NetLibrary. Cette recherche contribue à enrichir les connaissances sur (1) la lecture numérique, notamment celle du lectorat universitaire étudiant, et (2) l’impact d’un système de lecture sur l’efficacité de la lecture, sur les lecteurs, sur l’atteinte de l’objectif de lecture, et sur les stratégies de lecture utilisées. Outre les limites de l’étude, des pistes pour des recherches futures sont présentées.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Libraries are caught in the middle—between static or shrinking budgets on one hand and ever-expanding user needs on the other. How did we get here, and where do we go from here? This paper will offer two perspectives: Part I will present survey results about changing Library purchasing habits in light of changing formats, access, business models and user demands. Data from a previous survey on this topic will be compared and updated. Pricing trends and possible futures will be discussed. Part II will briefly trace the history of libraries’ roles in scholarly communication and connecting learners with knowledge. From there, we show an example of phasing in a patron-driven / demand-driven and short-term loan e-book program, complete with incorporating these tools in library instruction, research, and portable device loadability for field work.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This dissertation has the purpose to present a portable device named PlugData MG100G, equipped with a cellular module, to analyze the radiofrequency coverage in a GSM network situated in João Pessoa city, state of Paraíba, at four distinct regions. The equipment, originally, was developed to be used in fixed environments, so it was adapted so that it could be used in conditions of mobility. From the Mobile Measurement Reports (MMRs) RF coverage and the handover process are analyzed. The MMRs enable the identification of the serving cell and the list of the closest neighboring cells monitored by the mobile. This work analyses only data referent to the serving cell and the two closest neighboring cells. Inter-cell and intra-cell handovers are identified. The frequency planning and quality of service offered by the network related to the regions are discussed as well