995 resultados para pollutant emission


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Detailed three-dimensional CFD simulations involving flow and combustion chemistry are used to study the effect of swirl induced by re-entrant piston bowl geometries on pollutant emissions from a single-cylinder diesel engine. The baseline engine configuration consists of a hemispherical piston bowl and an injector with finite sac volume. The first iteration involved using a torroidal, slightly re-entrant bowl geometry, and a sac-less injector. Pollutant emission measurements indicated a reduction in emissions with this modification. Simulations on both configurations were then conducted to understand the effect of the changes. The simulation results indicate that the selected piston bowl geometry could actually be reducing the in-cylinder swirl and turbulence and the emission reduction may be entirely due to the introduction of the sac-less injector. In-cylinder air motion was then studied in a number of combustion chamber geometries, and a geometry which produced the highest in-cylinder swirl and Turbulence Kinetic Energy (TKE) around the compression top dead centre (TDC) was identified. The optimal nature of this re-entrant piston bowl geometry is confirmed by detailed combustion simulations and emission predictions. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Study of consumption rate and gaseous pollutant emission from engine tests simulating real work conditions, using spark point manually controlled and exhaust gas recirculation (EGR) in diverse proportion levels. The objective of this work is to re-examine the potential of the EGR conception, a well-known method of combustion control, employed together electronic fuel injection and three-way catalytic converter closed-loop control at a spark ignition engine, verifying the performance characteristics and technical availability of this conception to improve pollution control, fuel economy at low torque drive condition and to improve the engine exhaust components useful life. The pollutant emissions and consumption levels under operational conditions simulations were analysed and compared with the expected by concerning theory and real tests performed by EGR equipped engines by factory. Copyright © 2006 Society of Automotive Engineers, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The residence time distribution (RTD) is a crucial parameter when treating engine exhaust emissions with a Dielectric Barrier Discharge (DBD) reactor. In this paper, the residence time of such a reactor is investigated using a finite element based software: COMSOL Multiphysics 4.3. Non-thermal plasma (NTP) discharge is being introduced as a promising method for pollutant emission reduction. DBD is one of the most advantageous of NTP technologies. In a two cylinder co-axial DBD reactor, tubes are placed between two electrodes and flow passes through the annuals between these barrier tubes. If the mean residence time increases in a DBD reactor, there will be a corresponding increase in reaction time and consequently, the pollutant removal efficiency can increase. However, pollutant formation can occur during increased mean residence time and so the proportion of fluid that may remain for periods significantly longer than the mean residence time is of great importance. In this study, first, the residence time distribution is calculated based on the standard reactor used by the authors for ultrafine particle (10-500 nm) removal. Then, different geometrics and various inlet velocities are considered. Finally, for selected cases, some roughness elements added inside the reactor and the residence time is calculated. These results will form the basis for a COMSOL plasma and CFD module investigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a method for investigating ship emissions, the plume capture and analysis system (PCAS), and its application in measuring airborne pollutant emission factors (EFs) and particle size distributions. The current investigation was conducted in situ, aboard two dredgers (Amity: a cutter suction dredger and Brisbane: a hopper suction dredger) but the PCAS is also capable of performing such measurements remotely at a distant point within the plume. EFs were measured relative to the fuel consumption using the fuel combustion derived plume CO2. All plume measurements were corrected by subtracting background concentrations sampled regularly from upwind of the stacks. Each measurement typically took 6 minutes to complete and during one day, 40 to 50 measurements were possible. The relationship between the EFs and plume sample dilution was examined to determine the plume dilution range over which the technique could deliver consistent results when measuring EFs for particle number (PN), NOx, SO2, and PM2.5 within a targeted dilution factor range of 50-1000 suitable for remote sampling. The EFs for NOx, SO2, and PM2.5 were found to be independent of dilution, for dilution factors within that range. The EF measurement for PN was corrected for coagulation losses by applying a time dependant particle loss correction to the particle number concentration data. For the Amity, the EF ranges were PN: 2.2 - 9.6 × 1015 (kg-fuel)-1; NOx: 35-72 g(NO2).(kg-fuel)-1, SO2 0.6 - 1.1 g(SO2).(kg-fuel)-1and PM2.5: 0.7 – 6.1 g(PM2.5).(kg-fuel)-1. For the Brisbane they were PN: 1.0 – 1.5 x 1016 (kg-fuel)-1, NOx: 3.4 – 8.0 g(NO2).(kg-fuel)-1, SO2: 1.3 – 1.7 g(SO2).(kg-fuel)-1 and PM2.5: 1.2 – 5.6 g(PM2.5).(kg-fuel)-1. The results are discussed in terms of the operating conditions of the vessels’ engines. Particle number emission factors as a function of size as well as the count median diameter (CMD), and geometric standard deviation of the size distributions are provided. The size distributions were found to be consistently uni-modal in the range below 500 nm, and this mode was within the accumulation mode range for both vessels. The representative CMDs for the various activities performed by the dredgers ranged from 94-131 nm in the case of the Amity, and 58-80 nm for the Brisbane. A strong inverse relationship between CMD and EF(PN) was observed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Exhaust emissions from motor vehicles vary widely and depend on factors such as engine operating conditions, fuel, age, mileage and service history. A method has been devised to rapidly identify high-polluting vehicles as they travel on the road. The method is able to monitor emissions from a large number of vehicles in a short time and avoids the need to conduct expensive and time consuming tests on chassis dynamometers. A sample of the exhaust plume is captured as each vehicle passes a roadside monitoring station and the pollutant emission factors are calculated from the measured concentrations using carbon dioxide as a tracer. Although, similar methods have been used to monitor soot and gaseous mass emissions, to-date it has not been used to monitor particle number emissions from a large fleet of vehicles. This is particularly important as epidemiological studies have shown that particle number concentration is an important parameter in determining adverse health effects. The method was applied to measurements of particle number emissions from individual buses in the Brisbane City Council diesel fleet operating on the South-East Busway. Results indicate that the particle number emission factors are gamma- distributed, with a high proportion of the emissions being emitted by a small percentage of the buses. Although most of the high-emitters are the oldest buses in the fleet, there are clear exceptions, with some newer buses emitting as much. We attribute this to their recent service history, particularly pertaining to improper tuning of the engines. We recommend that a targeted correction program would be a highly effective measure in mitigating urban environmental pollution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The industry, over the years, has been working to improve the efficiency of diesel engines. More recently, it was observed the need to reduce pollutant emissions to conform to the stringent environmental regulations. This has attached a great interest to develop researches in order to replace the petroleum-based fuels by several types of less polluting fuels, such as blends of diesel oil with vegetable oil esters and diesel fuel with vegetable oils and alcohol, emulsions, and also microemulsions. The main objective of this work was the development of microemulsion systems using nonionic surfactants that belong to the Nonylphenols ethoxylated group and Lauric ethoxylated alcohol group, ethanol/diesel blends, and diesel/biodiesel blends for use in diesel engines. First, in order to select the microemulsion systems, ternary phase diagrams of the used blends were obtained. The systems were composed by: nonionic surfactants, water as polar phase, and diesel fuel or diesel/biodiesel blends as apolar phase. The microemulsion systems and blends, which represent the studied fuels, were characterized by density, viscosity, cetane number and flash point. It was also evaluated the effect of temperature in the stability of microemulsion systems, the performance of the engine, and the emissions of carbon monoxide, nitrogen oxides, unburned hydrocarbons, and smoke for all studied blends. Tests of specific fuel consumption as a function of engine power were accomplished in a cycle diesel engine on a dynamometer bench and the emissions were evaluated using a GreenLine 8000 analyzer. The obtained results showed a slight increase in fuel consumption when microemulsion systems and diesel/biodiesel blends were burned, but it was observed a reduction in the emission of nitrogen oxides, unburned hydrocarbons, smoke index and f sulfur oxides

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the first paper of this paper (Part I), conditions were presented for the gas cleaning technological route for environomic optimisation of a cogeneration system based in a thermal cycle with municipal solid waste incineration. In this second part, an environomic analysis is presented of a cogeneration system comprising a combined cycle composed of a gas cycle burning natural gas with a heat recovery steam generator with no supplementary burning and a steam cycle burning municipal solid wastes (MSW) to which will be added a pure back pressure steam turbine (another one) of pure condensation. This analysis aims to select, concerning some scenarios, the best atmospheric pollutant emission control routes (rc) according to the investment cost minimisation, operation and social damage criteria. In this study, a comparison is also performed with the results obtained in the Case Study presented in Part I. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The urbanization of modern societies has imposed to the planners and decision-makers a more precise attention to facts not considered before. Several aspects, such as the energy availability and the deleterious effect of pollution on the populations, must be considered in the policy decisions of cities urbanization. The current paradigm presents centralized power stations supplying a city, and a combination of technologies may compose the energy mix of a country, such as thermal power plants, hydroelectric plants, wind systems and solar-based systems, with their corresponding emission pattern. A goal programming multi-objective optimization model is presented for the electric expansion analysis of a tropical city, and also a case study for the city of Guaratinguetá, Brazil, considering a particular wind and solar radiation patterns established according to actual data and modeled via the time series analysis method. Scenarios are proposed and the results of single environmental objective, single economic objective and goal programming multi-objective modeling are discussed. The consequences of each dispatch decision, which considers pollutant emission exportation to the neighborhood or the need of supplementing electricity by purchasing it from the public electric power grid, are discussed. The results revealed energetic dispatch for the alternatives studied and the optimum environmental and economic solution was obtained. © 2012 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stricter environmental policies are shown necessary to ensure an effective pollutant emission control. It is expected for the present year of 2015, that Brazil will assume, at the 21th United Nation's Climate Change Conference (COP21), implementation of commitment to a low carbon economy. This positioning affects the industrial environment, so that is deemed necessary to search for new technologies, less aggressive to the environment, so the adequacies to the new emission policies do not cause a negative effect on production. Almost all of the processes performed in the steel industry demand burning fuel and, therefore, flue gases are sent to the atmosphere. In this present work is discussed the utilization of heat exchangers so, by recovering part of the available heat from the flue gases of certain industrial process, the combustion air is preheated. The combustion air preheat results in less energy requirement, i.e., less need of fuel consumption and, in addition, minor amount of pollutants to be emitted. Due to better fitting to the process, it is studied the utilization of spiral plate heat exchangers. The heat exchanger dimensioning is made by an iterative method implemented in the software Microsoft Excel. Subsequently are analyzed the gains in terms of process's thermal efficiency improvement and the percentage of fuel saving. The latter implies in reduction of the same percentage of greenhouse gases emission