991 resultados para optical heterodyne detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A narrow absorption feature in an atomic or molecular gas (such as iodine or methane) is used as the frequency reference in many stabilized lasers. As part of the stabilization scheme an optical frequency dither is applied to the laser. In optical heterodyne experiments, this dither is transferred to the RF beat signal, reducing the spectral power density and hence the signal to noise ratio over that in the absence of dither. We removed the dither by mixing the raw beat signal with a dithered local oscillator signal. When the dither waveform is matched to that of the reference laser the output signal from the mixer is rendered dither free. Application of this method to a Winters iodine-stabilized helium-neon laser reduced the bandwidth of the beat signal from 6 MHz to 390 kHz, thereby lowering the detection threshold from 5 pW of laser power to 3 pW. In addition, a simple signal detection model is developed which predicts similar threshold reductions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of conjugated polymers in the gas and volatile organic compounds (VOCs) detections represents an advance in the development of the electronic noses. Polythiophenes show good thermal and environmental stability, are easily synthesized and they have been studied as gas and VOCs sensors using different principles or transduction techniques. Among these techniques, optical sensing has been attracted attention, mainly due to its versatility. However, conjugated polymer-based optical sensors are still less studied. This paper describes the use of two poly(3-alkylthiophenes) for VOCs optical detection. The sensing measurements were carried out using visible spectroscopy. Both polymers showed good sensitivity to the VOCs, showing fast and reversible responses with some hysteresis, and were unable to detect hydroxylated samples. Furthermore, it was demonstrated that the thickness of polymer films influences the intensity of the optical response. Although there is similarity in the superficial composition of the polymers films, demonstrated by their surface energies, they showed significant differences in their optical properties upon exposure to the VOCs. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present three methods for the distortion-free enhancement of THz signals measured by electro-optic sampling in zinc blende-type detector crystals, e.g., ZnTe or GaP. A technique commonly used in optically heterodyne-detected optical Kerr effect spectroscopy is introduced, which is based on two measurements at opposite optical biases near the zero transmission point in a crossed polarizer detection geometry. In contrast to other techniques for an undistorted THz signal enhancement, it also works in a balanced detection scheme and does not require an elaborate procedure for the reconstruction of the true signal as the two measured waveforms are simply subtracted to remove distortions. We study three different approaches for setting an optical bias using the Jones matrix formalism and discuss them also in the framework of optical heterodyne detection. We show that there is an optimal bias point in realistic situations where a small fraction of the probe light is scattered by optical components. The experimental demonstration will be given in the second part of this two-paper series [J. Opt. Soc. Am. B, doc. ID 204877 (2014, posted online)].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acoustic resonances are observed in high-pressure discharge lamps operated with ac input modulated power frequencies in the kilohertz range. This paper describes an optical resonance detection method for high-intensity discharge lamps using computer-controlled cameras and image processing software. Experimental results showing acoustic resonances in high-pressure sodium lamps are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new approach, the four-window technique, was developed to measure optical phase-space-time-frequency tomography (OPSTFT). The four-window technique is based on balanced heterodyne detection with two local oscillator (LO) fields. This technique can provide independent control of position, momentum, time and frequency resolution. The OPSTFT is a Wigner distribution function of two independent Fourier transform pairs, phase-space and time-frequency. The OPSTFT can be applied for early disease detection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this thesis is to present a solution to the quantum phase problem of the single-mode optical field. The solution is based on the use of phase shift covariant normalized positive operator measures. These measures describe realistic direct coherent state phase measurements such as the phase measurement schemes based on eight-port homodyne detection or heterodyne detection. The structure of covariant operator measures and, more generally, covariant sesquilinear form measures is analyzed in this work. Four different characterizations for phase shift covariant normalized positive operator measures are presented. The canonical covariant operator measure is definded and its properties are studied. Finally, some other suggested phase theories are introduced to investigate their connections to the covariant sesquilinear form measures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A time efficient optical model is proposed for GATE simulation of a LYSO scintillation matrix coupled to a photomultiplier. The purpose is to avoid the excessively long computation time when activating the optical processes in GATE. The usefulness of the model is demonstrated by comparing the simulated and experimental energy spectra obtained with the dual planar head equipment for dosimetry with a positron emission tomograph ( DoPET). The procedure to apply the model is divided in two steps. Firstly, a simplified simulation of a single crystal element of DoPET is used to fit an analytic function that models the optical attenuation inside the crystal. In a second step, the model is employed to calculate the influence of this attenuation in the energy registered by the tomograph. The use of the proposed optical model is around three orders of magnitude faster than a GATE simulation with optical processes enabled. A good agreement was found between the experimental and simulated data using the optical model. The results indicate that optical interactions inside the crystal elements play an important role on the energy resolution and induce a considerable degradation of the spectra information acquired by DoPET. Finally, the same approach employed by the proposed optical model could be useful to simulate a scintillation matrix coupled to a photomultiplier using single or dual readout scheme.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper it is presented recent developments in the heterodyne detection holographic techniques for studding photosensitive materials. The actual state of the technique allows simultaneous and independent measurement of the refractive index and of the absorption coefficient changes in photosensitive materials and their use to self-stabilize the fringe pattern. The modeling of the measured signal together with the fringe stabilization allow the long term-fitting of the optical properties and the study the photosensitive materials close to the saturation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We consider the task of estimating the randomly fluctuating phase of a continuous-wave beam of light. Using the theory of quantum parameter estimation, we show that this can be done more accurately when feedback is used (adaptive phase estimation) than by any scheme not involving feedback (nonadaptive phase estimation) in which the beam is measured as it arrives at the detector. Such schemes not involving feedback include all those based on heterodyne detection or instantaneous canonical phase measurements. We also demonstrate that the superior accuracy of adaptive phase estimation is present in a regime conducive to observing it experimentally.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report on a novel experimental setup for distributed measurement of temperature, based on spontaneous Brillouin scattering in optical fiber. We have developed a mode-locked Brillouin fiber ring laser in order to generate the dual frequency source required for a heterodyne detection of the backscattered signal. This relatively simple system enables temperature measurements over 20 km with a spatial resolution of 7 m.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report on a novel experimental setup for distributed measurement of temperature, based on spontaneous Brillouin scattering in optical fiber. We have developed a mode-locked Brillouin fiber ring laser in order to generate the dual frequency source required for a heterodyne detection of the backscattered signal. This relatively simple system enables temperature measurements over 20 km with a spatial resolution of 7 m.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report for the first time the experimental demonstration of doubly differential quadrature phase shift keying (DDQPSK) using optical coherent detection. This method is more robust against high frequency offsets (FO) than conventional single differential quadrature phase shift keying (SDQPSK) with offset compensation. DDQPSK is shown to be able to compensate large FOs (up to the baud rate) and has lower computational requirements than other FO compensation methods. DDQPSK is a simple algorithm to implement in a real-time decoder for optical burst switched network scenarios. Simulation results are also provided, which show good agreement with the experimental results for both SDQPSK and DDQPSK transmissions. © 1989-2012 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article reports upon a community survey of malaria in Prábis, Guinea-Bissau. A house to house census of the population was initially carried out from August to December 1991(rainy season). After completing the census of each village, the population was invited to come, a week later, to a central point, where they were medically examined and finger-prick blood samples were collected for epidemiological characterization of the malaria situation in the area. The blood films of the one single village were used to compare the sensitivity and specificity of Polymerase Chain Reaction (PCR) with optical microscopy detection of parasites. In another village, the occurrence of parasitaemia was compared in children with and without fever. During the dry season, from March to June 1992, the population in each village was again invited to come to a central point. Some of the field procedures were repeated. The study revealed Prábis as an administrative Sector of Guinea-Bissau with endemic malaria, mostly due to Plasmodium falciparum, but with a significant rate of mixed infections. Active transmission occurred throughout the year, but it was more intensive during the rainy season and in the northwestern quadrant of the Sector. The level of endemicity of the villages varied from hypo to holoendemic. The factors associated with the differences among villages included village size and predominant economic activity (closeness to rice fields). The transmission paradigm was, most likely, a mixture of malaria of the African wet Savannah and malaria associated with irrigated paddy fields. PCR proved to be a sensitive method with low specificity during the dry season. Pyraexia of 37.4ºC or higher in children aged 2-9 years is not a sensitive indicator of parasitaemia but, it is highly specific and it has a clinically useful predictive value.