995 resultados para new version of NOTIS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Standardized olfactory tests are now available to quantitatively assess disorders of olfaction. A Brazilian-Portuguese version of the University of Pennsylvania Smell Identification Test (UPSIT) is currently being developed specifically for the Brazilian population. The most recent Brazilian-Portuguese version of the UPSIT (UPSIT-Br2) was administered to 88 Brazilian subjects who had no history of neurological or otorhinolaryngological disease. UPSIT-Br2 scores decreased with age, were lower in men than in women, and were lower in subjects with lower income. The degree to which the poorer performance of subjects with lower socio-economic status reflects lack of familiarity with test items is not known. Although this version of the UPSIT provides a sensitive and useful test of smell function for the Brazilian population, a revision of some test items is needed to achieve comparable norms to those found using the North American UPSIT in the United States.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The statistical analysis of compositional data should be treated using logratios of parts,which are difficult to use correctly in standard statistical packages. For this reason afreeware package, named CoDaPack was created. This software implements most of thebasic statistical methods suitable for compositional data.In this paper we describe the new version of the package that now is calledCoDaPack3D. It is developed in Visual Basic for applications (associated with Excel©),Visual Basic and Open GL, and it is oriented towards users with a minimum knowledgeof computers with the aim at being simple and easy to use.This new version includes new graphical output in 2D and 3D. These outputs could bezoomed and, in 3D, rotated. Also a customization menu is included and outputs couldbe saved in jpeg format. Also this new version includes an interactive help and alldialog windows have been improved in order to facilitate its use.To use CoDaPack one has to access Excel© and introduce the data in a standardspreadsheet. These should be organized as a matrix where Excel© rows correspond tothe observations and columns to the parts. The user executes macros that returnnumerical or graphical results. There are two kinds of numerical results: new variablesand descriptive statistics, and both appear on the same sheet. Graphical output appearsin independent windows. In the present version there are 8 menus, with a total of 38submenus which, after some dialogue, directly call the corresponding macro. Thedialogues ask the user to input variables and further parameters needed, as well aswhere to put these results. The web site http://ima.udg.es/CoDaPack contains thisfreeware package and only Microsoft Excel© under Microsoft Windows© is required torun the software.Kew words: Compositional data Analysis, Software

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The statistical analysis of compositional data should be treated using logratios of parts, which are difficult to use correctly in standard statistical packages. For this reason a freeware package, named CoDaPack was created. This software implements most of the basic statistical methods suitable for compositional data. In this paper we describe the new version of the package that now is called CoDaPack3D. It is developed in Visual Basic for applications (associated with Excel©), Visual Basic and Open GL, and it is oriented towards users with a minimum knowledge of computers with the aim at being simple and easy to use. This new version includes new graphical output in 2D and 3D. These outputs could be zoomed and, in 3D, rotated. Also a customization menu is included and outputs could be saved in jpeg format. Also this new version includes an interactive help and all dialog windows have been improved in order to facilitate its use. To use CoDaPack one has to access Excel© and introduce the data in a standard spreadsheet. These should be organized as a matrix where Excel© rows correspond to the observations and columns to the parts. The user executes macros that return numerical or graphical results. There are two kinds of numerical results: new variables and descriptive statistics, and both appear on the same sheet. Graphical output appears in independent windows. In the present version there are 8 menus, with a total of 38 submenus which, after some dialogue, directly call the corresponding macro. The dialogues ask the user to input variables and further parameters needed, as well as where to put these results. The web site http://ima.udg.es/CoDaPack contains this freeware package and only Microsoft Excel© under Microsoft Windows© is required to run the software. Kew words: Compositional data Analysis, Software

Relevância:

100.00% 100.00%

Publicador:

Resumo:

EUMETSAT (www.eumetsat.int) e’ l’agenzia europea per operazioni su satelliti per monitorare clima, meteo e ambiente terrestre. Dal centro operativo situato a Darmstadt (Germania), si controllano satelliti meteorologici su orbite geostazionarie e polari che raccolgono dati per l’osservazione dell’atmosfera, degli oceani e della superficie terrestre per un servizio continuo di 24/7. Un sistema di monitoraggio centralizzato per programmi diversi all’interno dell’ambiente operazionale di EUMETSAT, e’ dato da GEMS (Generic Event Monitoring System). Il software garantisce il controllo di diverse piattaforme, cross-monitoring di diverse sezioni operative, ed ha le caratteristiche per potere essere esteso a future missioni. L’attuale versione della GEMS MMI (Multi Media Interface), v. 3.6, utilizza standard Java Server Pages (JSP) e fa uso pesante di codici Java; utilizza inoltre files ASCII per filtri e display dei dati. Conseguenza diretta e’ ad esempio, il fatto che le informazioni non sono automaticamente aggiornate, ma hanno bisogno di ricaricare la pagina. Ulteriori inputs per una nuova versione della GEMS MMI vengono da diversi comportamenti anomali riportati durante l’uso quotidiano del software. La tesi si concentra sulla definizione di nuovi requisiti per una nuova versione della GEMS MMI (v. 4.4) da parte della divisione ingegneristica e di manutenzione di operazioni di EUMETSAT. Per le attivita’ di supporto, i test sono stati condotti presso Solenix. Il nuovo software permettera’ una migliore applicazione web, con tempi di risposta piu’ rapidi, aggiornamento delle informazioni automatico, utilizzo totale del database di GEMS e le capacita’ di filtri, insieme ad applicazioni per telefoni cellulari per il supporto delle attivita’ di reperibilita’. La nuova versione di GEMS avra’ una nuova Graphical User Interface (GUI) che utilizza tecnologie moderne. Per un ambiente di operazioni come e’ quello di EUMETSAT, dove l’affidabilita’ delle tecnologie e la longevita’ dell’approccio scelto sono di vitale importanza, non tutti gli attuali strumenti a disposizione sono adatti e hanno bisogno di essere migliorati. Allo stesso tempo, un’ interfaccia moderna, in termini di visual design, interattivita’ e funzionalita’, e’ importante per la nuova GEMS MMI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Results of previous studies conducted by different researchers have shown that impact techniques can be used to evaluate firmness (Delwiche et al., 1989; Delwiche et al.;1996; Jaren et al., 1992; Ruiz Altisent et al., 1996). To impact the fruit with a small spherical impactor of known mass and radius of curvature and measure the acceleration of the impactor is a technique described by Chen et al. (1985) and used by several researchers for sensing fruit firmness (Jaren et al., 1992; Correa et al.; 1992). The advantages of this method vs. a force sensor that measures the force as a function of time is that the measured impact-acceleration response is independent of the fruit mass and is less sensitive to the variation in the radius of curvature of the fruit (Chen et al., 1996). Ruiz Altisent et al. (1993) developed and used a 50 g impactor with a 19 mm diameter spherical tip, dropping from different height for fruits (apples, pears, avocados, melons, peaches ...). Another impact device for firmness sensing of fruits was developed by Chen and Ruiz Altisent (1996). They designed and fabricated an experimental low-mass impact sensor for high-speed sensing of fruit firmness. The impactor consisted of a semi-spherical impacting tip attached to the end (near the centre of percussion) of a pivoting arm. Impact is done by swinging the impactor to collide with the fruit. It has been implemented for on-line use. In both devices a small accelerometer is mounted behind the impacting tip. Lateral impactor and vertical impactor have been used in laboratory and the results from non-destructive impact tests have contributed to standardise methods to measure fruit firmness: Barreiro (1992) compared impact parameters and results of Magness-Taylor penetration tests for apples, pears, apricots [and peaches; Agulheiro (1994) studied the behaviour of the impact parameters during seven weeks of cold storage of two melon varieties; Ortiz (1998) used low energy impact and NIR procedures to segregate non crispy, non firm and soft peaches. Steinmetz (1996) compared various non-destructive firmness sensors, based on sound, impact and micro-deformation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"This manuscript purports to be the joint work of Selkirk and Defoe"--Explanatory note.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quasi-uniform grids of the sphere have become popular recently since they avoid parallel scaling bottle- necks associated with the poles of latitude–longitude grids. However quasi-uniform grids of the sphere are often non- orthogonal. A version of the C-grid for arbitrary non- orthogonal grids is presented which gives some of the mimetic properties of the orthogonal C-grid. Exact energy conservation is sacrificed for improved accuracy and the re- sulting scheme numerically conserves energy and potential enstrophy well. The non-orthogonal nature means that the scheme can be used on a cubed sphere. The advantage of the cubed sphere is that it does not admit the computa- tional modes of the hexagonal or triangular C-grids. On var- ious shallow-water test cases, the non-orthogonal scheme on a cubed sphere has accuracy less than or equal to the orthog- onal scheme on an orthogonal hexagonal icosahedron. A new diamond grid is presented consisting of quasi- uniform quadrilaterals which is more nearly orthogonal than the equal-angle cubed sphere but with otherwise similar properties. It performs better than the cubed sphere in ev- ery way and should be used instead in codes which allow a flexible grid structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Piezoelectric ceramics, such as PZT, can generate subnanometric displacements, bu t in order to generate multi- micrometric displacements, they should be either driven by high electric voltages (hundreds of volts ), or operate at a mechanical resonant frequency (in narrow band), or have large dimensions (tens of centimeters). A piezoelectric flextensional actuator (PFA) is a device with small dimensions that can be driven by reduced voltages and can operate in the nano- and micro scales. Interferometric techniques are very adequate for the characterization of these devices, because there is no mechanical contact in the measurement process, and it has high sensitivity, bandwidth and dynamic range. A low cost open-loop homodyne Michelson interferometer is utilized in this work to experimentally detect the nanovi brations of PFAs, based on the spectral analysis of the interfero metric signal. By employing the well known J 1 ...J 4 phase demodulation method, a new and improved version is proposed, which presents the following characteristics: is direct, self-consistent, is immune to fading, and does not present phase ambiguity problems. The proposed method has resolution that is similar to the modified J 1 ...J 4 method (0.18 rad); however, differently from the former, its dynamic range is 20% larger, does not demand Bessel functions algebraic sign correction algorithms and there are no singularities when the static phase shift between the interferometer arms is equal to an integer multiple of  /2 rad. Electronic noise and random phase drifts due to ambient perturbations are taken into account in the analysis of the method. The PFA nanopositioner characterization was based on the analysis of linearity betw een the applied voltage and the resulting displacement, on the displacement frequency response and determination of main resonance frequencies.