985 resultados para natural ventilation
Resumo:
The objective of the consultative phase is to examine the role that natural ventilation has and can play in the subdivision planning process in SEQ. The Centre for Subtropical Design at QUT coordinated the consultative phase and has conducted a workshop, and interviews, with stakeholders including developers, land development consultants, land surveyors, urban designers and regulators, to identify current understanding of the impact of urban subdivision on natural ventilation, and the role of natural ventilation in achieving energy efficiency for dwellings. This report details the findings.
Resumo:
Complex behaviour of air flow in the buildings makes it difficult to predict. Consequently, architects use common strategies for designing buildings with adequate natural ventilation. However, each climate needs specific strategies and there are not many heuristics for subtropical climate in literature. Furthermore, most of these common strategies are based on low-rise buildings and their performance for high-rise buildings might be different due to the increase of the wind speed with increase in the height. This study uses Computational Fluid Dynamics (CFD) to evaluate these rules of thumb for natural ventilation for multi-residential buildings in subtropical climate. Four design proposals for multi-residential towers with natural ventilation which were produced in intensive two days charrette were evaluated using CFD. The results show that all the buildings reach acceptable level of wind speed in living areas and poor amount of air flow in sleeping areas.
Resumo:
Balconies, as one of the main architectural features in subtropical climates, are assumed to enhance the ventilation performance of buildings by redirecting the wind. Although there are some studies on the effect of balconies on natural ventilation inside buildings, the majority have been conducted on single zone buildings with simple geometries. The purpose of this study is to explore the effect of balconies on the internal air flow pattern and ventilation performance of multi-storey residential buildings with internal partitions. To this end, a sample residential unit was selected for investigation and three different conditions tested, base case (no balcony), an open balcony and a semi-enclosed balcony. Computational Fluid Dynamics is used as an analysis method due to its accuracy and ability to provide detailed results. The cases are analysed in terms of average velocity, flow uniformity and number of Air Changes per Hour (ACH). The results suggest the introduction of a semi-enclosed balcony into high-rise dwellings improves the average velocity and flow uniformity. Integrating an open balcony results in reduction of the aforementioned parameters at 0° wind incidence.
Resumo:
Indoor air quality is a critical factor in the classroom due to high people concentration in a unique space. Indoor air pollutant might increase the chance of both long and short-term health problems among students and staff, reduce the productivity of teachers and degrade the student’s learning environment and comfort. Adequate air distribution strategies may reduce risk of infection in classroom. So, the purpose of air distribution systems in a classroom is not only to maximize conditions for thermal comfort, but also to remove indoor contaminants. Natural ventilation has the potential to play a significant role in achieving improvements in IAQ. The present study compares the risk of airborne infection between Natural Ventilation (opening windows and doors) and a Split-System Air Conditioner in a university classroom. The Wells-Riley model was used to predict the risk of indoor airborne transmission of infectious diseases such as influenza, measles and tuberculosis. For each case, the air exchange rate was measured using a CO2 tracer gas technique. It was found that opening windows and doors provided an air exchange rate of 2.3 air changes/hour (ACH), while with the Split System it was 0.6 ACH. The risk of airborne infection ranged between 4.24 to 30.86 % when using the Natural Ventilation and between 8.99 to 43.19% when using the Split System. The difference of airborne infection risk between the Split System and the Natural Ventilation ranged from 47 to 56%. Opening windows and doors maximize Natural Ventilation so that the risk of airborne contagion is much lower than with Split System.
Resumo:
Experiments were conducted in water and wind tunnels on spheres in the Reynolds number range 6 x 10(3) to 6.5 x 10(5) to study the effect of natural ventilation on the boundary layer separation and near-wake Vortex shedding characteristics. In the subcritical range of Re (<2 x 10(5)), ventilation caused a marginal downstream shift in the location of laminar boundary layer separation; there was only a small change in the vortex shedding frequency. In the supercritical range (Re > 4 x 10(5)), ventilation caused a downstream shift in the mean locations of boundary layer separation and reattachment; these lines showed significant axisymmetry in the presence of venting. No distinct vortex shedding frequency was found. Instead, a dramatic reduction occurred in the wake unsteadiness at all frequencies. The reduction of wake unsteadiness is consistent with the reduction in total drag already reported. Based on the present results and those reported earlier, the effects of natural ventilation on the flow past a sphere can be categorized in two broad regimes, viz., weak and strong interaction regimes. In the weak interaction regime (subcritical Re), the broad features of the basic sphere are largely unaltered despite the large addition of mass in the near wake. Strong interaction is promoted by the closer proximity of the inner and outer shear layers at supercritical Re. This results in a modified and steady near-wake flow, characterized by reduced unsteadiness and small drag.
Resumo:
Buoyant jets in natural ventilation of a model room with water as the fluid medium have been studied. A constant heat flux has been maintained on the bottom surface of the room. The buoyancy causes flow to enter through the bottom opening and leave through the top opening. The shadowgraph technique is used for visualization. At the inlet, a negatively buoyant jet is observed, whereas a positively buoyant jet is observed at the outlet. The theoretical results for the centerline trajectories of these buoyant jets using both Gaussian and top-hat profiles are discussed considering the variation of the entrainment coefficient with the local Froude number and the variation of the spreading ratio of buoyancy to velocity profile with the distance from the source. The shape of the profiles is found to evolve from top-hat to Gaussian geometry.
Resumo:
The natural ventilation of a well-mixed, pre-heated room with a point source of heating, and openings at the base and roof is investigated. The transient draining associated with the room being warmer than the exterior combined with the convective ow produced by the point source of heat leads to a fascinating series of transient ow regimes as the system evolves to the two-layer steady-state regime described by Linden, Lane-Ser_ and Smeed [1]. As the room begins to ventilate, a turbulent plume rises from the point source of heat to the ceiling, and typically forms a deepening layer of hot air. However, with a weak heat source, then at some point the ascending plume will intrude beneath the layer of original uid. Otherwise, the ascending plume always reaches the top of the room as the system evolves to a steady state. We develop a simpli_ed model of the transient evolution and test this with some new laboratory experiments. We conclude with a discussion of the implications of our results for real buildings.
Resumo:
We investigate the steady state natural ventilation of an enclosed space in which vent A, located at height hA above the floor, is connected to a vertical stack with a termination at height H, while the second vent, B, at height hB above the floor, connects directly to the exterior. We first examine the flow regimes which develop with a distributed source of heating at the base of the space. If hBhB>hA, then two different flow regimes may develop. Either (i) there is inflow through vent B and outflow through vent A, or (ii) the flow reverses, with inflow down the stack into vent A and outflow through vent B. With inflow through vent A, the internal temperature and ventilation rate depend on the relative height of the two vents, A and B, while with inflow through vent B, they depend on the height of vent B relative to the height of the termination of the stack H. With a point source of heating, a similar transition occurs, with a unique flow regime when vent B is lower than vent A, and two possible regimes with vent B higher than vent A. In general, with a point source of buoyancy, each steady state is characterised by a two-layer density stratification. Depending on the relative heights of the two vents, in the case of outflow through vent A connected to the stack, the interface between these layers may lie above, at the same level as or below vent A, leading to discharge of either pure upper layer, a mixture of upper and lower layer, or pure lower layer fluid. In the case of inflow through vent A connected to the stack, the interface always lies below the outflow vent B. Also, in this case, if the inflow vent A lies above the interface, then the lower layer becomes of intermediate density between the upper layer and the external fluid, whereas if the interface lies above the inflow vent A, then the lower layer is composed purely of external fluid. We develop expressions to predict the transitions between these flow regimes, in terms of the heights and areas of the two vents and the stack, and we successfully test these with new laboratory experiments. We conclude with a discussion of the implications of our results for real buildings.
Resumo:
We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.
Resumo:
Application of laboratory analogue modelling of air flow in a naturally ventilated shopping mall is reviewed in this paper. A detailed study of the ventilation was undertaken to establish the principles and to explore how natural ventilation might interact with a localised mechanical ventilation system designed to enhance the cooling of a high density food court area. The case study is used to show how the combination of laboratory modelling and simplified mathematical modelling enables one to rapidly identify the various flow regimes which can occur, to quantify the resultant flows and mean temperatures and to thereby develop appropriate ventilation strategies for the different external conditions which occur through the year.
Resumo:
The natural ventilation of a building, flanked by others forming urban canyons and driven by the combined forces of wind and thermal buoyancy, has been studied experimentally at small scale. The aim was to improve our understanding of the effect of the urban canyon geometry on passive building ventilation. The steady ventilation of an isolated building was observed to change dramatically, both in terms of the thermal stratification and airflow rate, when placed within the confines of urban canyons. The ventilation flows and internal stratifications observed at small scale are presented for a range of canyon widths (building densities) and wind speeds. Two typical opening arrangements are considered. Flanking an otherwise isolated building with others of similar geometry as in a typical urban canyon was shown to reverse the effect of wind on the thermally-driven ventilation. As a consequence, neglecting the surrounding geometry when designing naturally-ventilated buildings may result in poor ventilation. Further implications are discussed.
Resumo:
The three effectiveness measures based on the ability of a flow to flush buoyancy from a ventilated space proposed by Coffey and Hunt [Ventilation effectiveness measures based on heat removal-part 1. Definitions. Building and Environment, in press, doi:10.1016/j.buildenv.2006.03.016.] are applied to assess and compare two fundamental natural ventilation flows. We focus on the limiting cases of passive displacement and passive mixing ventilation flows during transient conditions. These transient flows occur when, for example, heat is purged from a building at night. Whilst it is widely recognised that mixing flows are less efficient at purging heat than displacement flows, our results indicate that, when a particular zone of a room is considered, displacement ventilation can result in lower effectiveness than mixing ventilation. When a room is considered as a whole, displacement ventilation yields higher effectiveness than mixing ventilation and we quantify these differences in terms of the geometry of the space and opening area. The proposed theoretical predictions are compared with effectiveness deduced from measurements made during laboratory experiments and show good agreement. © 2006 Elsevier Ltd. All rights reserved.