993 resultados para maximum-intensity projection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dental radiographs play the major role in the identification of victims in mass casualties besides DNA. Under circumstances such as those caused by the recent tsunami in Asia, it is nearly impossible to document the entire dentition using conventional x-rays as it would be too time consuming. Multislice computed tomography can be used to scan the dentition of a deceased within minutes, and the postprocessing software allows visualization of the data adapted to every possible antemortem x-ray for identification. We introduce the maximum intensity projection of cranial computed tomography data for the purpose of dental identification exemplarily in a case of a burned corpse. As transportable CT scanners already exist, these could be used to support the disaster victim identification teams in the field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The motion of lung tumors during respiration makes the accurate delivery of radiation therapy to the thorax difficult because it increases the uncertainty of target position. The adoption of four-dimensional computed tomography (4D-CT) has allowed us to determine how a tumor moves with respiration for each individual patient. Using information acquired during a 4D-CT scan, we can define the target, visualize motion, and calculate dose during the planning phase of the radiotherapy process. One image data set that can be created from the 4D-CT acquisition is the maximum-intensity projection (MIP). The MIP can be used as a starting point to define the volume that encompasses the motion envelope of the moving gross target volume (GTV). Because of the close relationship that exists between the MIP and the final target volume, we investigated four MIP data sets created with different methodologies (3 using various 4D-CT sorting implementations, and one using all available cine CT images) to compare target delineation. It has been observed that changing the 4D-CT sorting method will lead to the selection of a different collection of images; however, the clinical implications of changing the constituent images on the resultant MIP data set are not clear. There has not been a comprehensive study that compares target delineation based on different 4D-CT sorting methodologies in a patient population. We selected a collection of patients who had previously undergone thoracic 4D-CT scans at our institution, and who had lung tumors that moved at least 1 cm. We then generated the four MIP data sets and automatically contoured the target volumes. In doing so, we identified cases in which the MIP generated from a 4D-CT sorting process under-represented the motion envelope of the target volume by more than 10% than when measured on the MIP generated from all of the cine CT images. The 4D-CT methods suffered from duplicate image selection and might not choose maximum extent images. Based on our results, we suggest utilization of a MIP generated from the full cine CT data set to ensure a representative inclusive tumor extent, and to avoid geometric miss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the technologies for the fabrication of high quality microarray advances rapidly, quantification of microarray data becomes a major task. Gridding is the first step in the analysis of microarray images for locating the subarrays and individual spots within each subarray. For accurate gridding of high-density microarray images, in the presence of contamination and background noise, precise calculation of parameters is essential. This paper presents an accurate fully automatic gridding method for locating suarrays and individual spots using the intensity projection profile of the most suitable subimage. The method is capable of processing the image without any user intervention and does not demand any input parameters as many other commercial and academic packages. According to results obtained, the accuracy of our algorithm is between 95-100% for microarray images with coefficient of variation less than two. Experimental results show that the method is capable of gridding microarray images with irregular spots, varying surface intensity distribution and with more than 50% contamination

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Gadolinium-enhanced pulmonary magnetic resonance angiography (MRA) can be an option in patients with a history of previous adverse reaction to iodinated contrast material and renal insufficiency. Radiation is also avoided. The aim of this study is to prospectively compare the diagnostic value of MRA with that of a diagnostic strategy, taking into account catheter angiography, computed tomography angiography (CTA), and lung scintigraphy [ventilation-perfusion (VQ)]. MATERIAL AND METHODS: Magnetic resonance angiography was done in 48 patients with clinically suspected pulmonary embolism (PE) using fast gradient echo coronal acquisition with gadolinium. Interpretation was done with native coronal images and multiplanar maximum intensity projection reconstructions. Results were compared to catheter angiography (n=15), CTA (n=34), VQ (n=45), as well as 6-12 months clinical follow-ups, according to a sequenced reference tree. RESULTS: The final diagnosis of PE was retained in 11 patients (23%). There were two false negatives and no false positive results with MRA. Computed tomography angiography resulted in no false negatives or false positives. Magnetic resonance angiography had a sensitivity of 82% and a specificity of 100%. CONCLUSION: In our study, pulmonary MRA had a sensitivity of 82% and a specificity of 100% for the diagnosis of PE, with slightly less sensitivity than CTA. In the diagnostic algorithm of PE, pulmonary MRA should be considered as an alternative to CTA when iodine contrast injection or radiation is a significant matter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: La DSA es el método de elección para el seguimiento de pacientes con aneurismas intracraneales embolizados; esta se puede asociar a complicaciones incapacitantes o mortales. La MRA se ha propuesto como método alternativo por menor costo y menos morbi-mortalidad, aunque su desempeño diagnóstico permanece en discusión debido al desarrollo de nuevos protocolos, resonadores más potentes y nuevas aplicaciones de la DSA. Metodología: Exploramos la literatura hasta la actualidad y comparamos el desempeño diagnóstico de la MRA con la DSA para detectar flujo residual posterior a la embolización terapéutica de aneurismas intracraneales. Realizamos una revisión sistemática de la literatura y meta-análisis basados en 34 artículos detectados en la búsqueda que incluyó las bases de datos PubMed, Scopus, ScIELO y BVS. Resultados: La TOF-MRA demostró sensibilidad de 86.8% (84.3%-89.1%) y especificidad de 91.2% (89%-93.1%); la SROC para TOF-MRA demostró un AUC de 0.95. El desempeño de la CE-MRA demostró sensibilidad de 88.1% (84.6%-91.1%) y especificidad de 89.1% (85.7%-91.9%); la SROC presentó una AUC de 0.93. El análisis estratificado por potencia del resonador encontró que la TOF-MRA tiene mejor desempeño con el resonador de 3T, aunque no es estadísticamente significativo. La concordancia interobservador con TOF-MRA y CE-MRA fue moderada a muy buena. Discusión: El desempeño diagnóstico de la MRA en el seguimiento de aneurismas intracraneales embolizados demostró ser bueno, con sensibilidad mayor a 84%, siendo ligeramente mejor con TOF-MRA, sin lograr reemplazar la DSA. Sin embargo, los resultados deben ser evaluados con precaución por la heterogeneidad de los resultados de los estudios incluidos. (Abreviaturas: DSA: Angiografía por Sustracción Digital; MRA: Angiografía por Resonancia Magnética; TOF-MRA: Angiorresonancia por Tiempo de Vuelo; CE-MRA: Angiorresonancia contrastada).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To determine the accuracy of automated vessel-segmentation software for vessel-diameter measurements based on three-dimensional contrast-enhanced magnetic resonance angiography (3D-MRA). METHOD: In 10 patients with high-grade carotid stenosis, automated measurements of both carotid arteries were obtained with 3D-MRA by two independent investigators and compared with manual measurements obtained by digital subtraction angiography (DSA) and 2D maximum-intensity projection (2D-MIP) based on MRA and duplex ultrasonography (US). In 42 patients undergoing carotid endarterectomy (CEA), intraoperative measurements (IOP) were compared with postoperative 3D-MRA and US. RESULTS: Mean interoperator variability was 8% for measurements by DSA and 11% by 2D-MIP, but there was no interoperator variability with the automated 3D-MRA analysis. Good correlations were found between DSA (standard of reference), manual 2D-MIP (rP=0.6) and automated 3D-MRA (rP=0.8). Excellent correlations were found between IOP, 3D-MRA (rP=0.93) and US (rP=0.83). CONCLUSION: Automated 3D-MRA-based vessel segmentation and quantification result in accurate measurements of extracerebral-vessel dimensions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a simulation model, which was incorporated into a Geographic Information System (GIS), in order to calculate the maximum intensity of urban heat islands based on urban geometry data. The method-ology of this study stands on a theoretical-numerical basis (Okeâ s model), followed by the study and selection of existing GIS tools, the design of the calculation model, the incorporation of the resulting algorithm into the GIS platform and the application of the tool, developed as exemplification. The developed tool will help researchers to simulate UHI in different urban scenarios.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The intensity, duration, and frequency relationship (IDF) of rainfall occurrence may be done through continuous records of pluviographs or daily pluviometer values . The objective of this study was to estimate the intensity-duration-frequency relationships of precipitation, using the method of daily rainfall disaggregation, at weather stations located to the southern half of the state of Rio Grande do Sul; comparing them with those obtained by rain gauge records, in places considered homogeneous from the meteorological point of view. The IDF equation parameters were estimated from daily rainfall disaggregation data, using the method of nonlinear optimization. To validate the equations confidence indices and efficiency and the "t" Student test, among maximum intensity values obtained from the disaggregated daily rainfall durations of 10; 30; 60 min and 6; 12 and 24 h and those extracted from existing IDF equations. For all studied stations and return periods, the trust index values were regarded as "optimal", i.e., greater than 0.85. The maximal intensity of rainfall obtained by daily rainfall disaggregation have similarity with those obtained by relations IDF standards. Thus, the method constitutes a feasible alternative in obtaining the IDF relationships.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Anaerobic efforts are commonly required through repeated sprint during efforts in many sports, making the anaerobic pathway a target of training. Nevertheless, to identify improvements on such energetic way it is necessary to assess anaerobic capacity or power, which is usually complex. For this purpose, authors have postulated the use of short running performances to anaerobic ability assessment. Thus, the aim of this study was to find a relationship between running performances on anaerobic power, anaerobic capacity or repeated sprint ability. Methods Thirteen military performed maximal running of 50 (P50), 100 (P100) and 300 (P300) m on track, beyond of running-based anaerobic sprint test (RAST; RSA and anaerobic power test), maximal anaerobic running test (MART; RSA and anaerobic capacity test) and the W′ from critical power model (anaerobic capacity test). Results By RAST variables, peak and average power (absolute and relative) and maximum velocity were significantly correlated with P50 (r = −0.68, p = 0.03 and −0.76, p = 0.01; −0.83, p < 0.01 and −0.83, p < 0.01; and −0.78, p < 0.01), respectively. The maximum intensity of MART was negatively and significantly correlated with P100 (r = −0.59) and W′ was not statistically correlated with any of the performances. Conclusion MART and W′ were not correlated with short running performances, having a weak performance predicting probably due to its longer duration in relation to assessed performances. Observing RAST outcomes, we postulated that such a protocol can be used during daily training as short running performance predictor.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo deste trabalho foi testar uma teoria termodinâmica em brisas marítimas-terrestres acopladas com brisas de vale-montanha através de simulações numéricas tridimensionais em uma região da costa leste do Nordeste Brasileiro, considerando a presença e a ausência da topografia. Embora o contraste de temperatura entre as superfícies seja importante na formação da brisa, a eficiência termodinâmica é fundamental na determinação da sua intensidade. Tem-se que a inclinação faz com que a diferença de pressão entre dois pontos fique maior durante o dia e menor durante a noite contribuindo para a formação de brisas marítimas mais intensas e de brisas terrestres menos intensas, respectivamente. A máxima queda de pressão ocorre por volta de três horas antes da máxima intensidade da brisa. Isso porque grande parte da energia disponibilizada para as circulações é gasta para vencer dissipação, principalmente, no período diurno, quando esses processos são realmente efetivos. Do ponto de vista puramente termodinâmico a inclinação da montanha atua para intensificar a brisa durante o dia e para enfraquecê-la durante a noite.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

One of the current frontiers in the clinical management of Pectus Excavatum (PE) patients is the prediction of the surgical outcome prior to the intervention. This can be done through computerized simulation of the Nuss procedure, which requires an anatomically correct representation of the costal cartilage. To this end, we take advantage of the costal cartilage tubular structure to detect it through multi-scale vesselness filtering. This information is then used in an interactive 2D initialization procedure which uses anatomical maximum intensity projections of 3D vesselness feature images to efficiently initialize the 3D segmentation process. We identify the cartilage tissue centerlines in these projected 2D images using a livewire approach. We finally refine the 3D cartilage surface through region-based sparse field level-sets. We have tested the proposed algorithm in 6 noncontrast CT datasets from PE patients. A good segmentation performance was found against reference manual contouring, with an average Dice coefficient of 0.75±0.04 and an average mean surface distance of 1.69±0.30mm. The proposed method requires roughly 1 minute for the interactive initialization step, which can positively contribute to an extended use of this tool in clinical practice, since current manual delineation of the costal cartilage can take up to an hour.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A detailed study of voltammetric behavior of ethiofencarb (ETF) is reported using glassy carbon electrode (GCE) and hanging mercury drop electrode (HMDE). With GCE, it is possible to verify that the oxidative mechanism is irreversible, independent of pH, and the maximum intensity current was observed at +1.20 V vs. AgCl/Ag at pH 1.9. A linear calibration line was obtained from 1.0x10-4 to 8.0x10-4 mol L-1 with SWV method. To complete the electrochemical knowledge of ETF pesticide, the reduction was also explored with HMDE. A well-defined peak was observed at –1.00V vs. AgCl/Ag in a large range of pH with higher signal at pH 7.0. Linearity was obtained in 4.2x10-6 and 9.4x10-6 mol L-1 ETF concentration range. An immediate alkaline hydrolysis of ETF was executed, producing a phenolic compound (2-ethylthiomethylphenol) (EMP), and the electrochemical activity of the product was examined. It was deduced that it is oxidized on GCE at +0.75V vs. AgCl/Ag with a maximum peak intensity current at pH 3.2, but the compound had no reduction activity on HMDE. Using the decrease of potential peak, a flow injection analysis (FIA) system was developed connected to an amperometric detector, enabling the determination of EMP over concentration range of 1.0x10-7 and 1.0x10-5 mol L-1 at a sampling rate of 60 h-1. The results provided by FIA methodology were performed by comparison with results from high-performance liquid chromatography (HPLC) technique and demonstrated good agreement with relative deviations lower than 4%. Recovery trials were performed and the obtained values were between 98 and 104%.