953 resultados para low-temperature heat capacity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives of this investigation were to measure the effects of moderate heat treatments (below the dehydroxylation temperature) on physical and chemical properties of a calcium-montmorillonite clay. Previous workers have noted the reduction in cation exchange capacity and swelling property after heating in the range 200 to 400°C, and have suggested several possible explanations, such as hysteresis effect, increased inter-layer attractions due to removal of inter-layer water, or changes in the disposition of inter-layer or layer surface ions. The liquid limits of Ca-montmorillonite were steadily decreased with increased temperature of treatment, levelling at about 450°C. The plastic limit decreased slightly up to 350°C, above which samples could no longer be rolled into threads. The gradual change is in contrast with sudden major changes noted for weight loss (maximum rates of change at l00°C and 500°C), glycol retention surface area (520°C), and d001 diffraction peak intensity (17.7 A spacing) and breadth after glycolation (530°C). Other properties showing more gradual reductions with heat treatment were amount of exchangeable calcium (without water soaking), cation exchange capacity by NH4AC method, and d001 intensity (21 A spacing) after storing at 100% r.h. one month and re-wetting with water. Previous water soaking allowed much greater release of fixed Ca++ up to 450°C. Similar results were obtained with cation exchange capacities when samples were treated with N CaCl2 solution. The 21.0 A peak intensity curve showed close similarity to the liquid limit and plastic index curves in the low temperature range, and an explanation is suggested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of Nb(3)Al and Nb(3)Sn superconductors is of great interest for the applied superconductivity area. These intermetallics composites are obtained normally by heat treatment reactions at high temperature. Processes that allow formation of the superconducting phases at lower temperatures (<1000 degrees C), particularly for Nb(3)Al, are of great interest. The present work studies phase formation and stability of Nb(3)Al and Nb(3)Sn superconducting phases using mechanical alloying (high energy ball milling). Our main objective was to form composites near stoichiometry, which could be transformed into the superconducting phases using low-temperature heat treatments. High purity Nb-Sn and Nb-Al powders were mixed to generate the required superconducting phases (Nb-25at.%Sn and Nb-25at.%Al) in an argon atmosphere glove-box. After milling in a Fritsch mill, the samples were compressed in a hydraulic uniaxial press and encapsulated in evacuated quartz tubes for heat treatment. The compressed and heat treated samples were characterized using X-ray diffractometry. Microstructure and chemical analysis were accomplished using scanning electron microscopy and energy dispersive spectrometry. Nb(3)Al XRD peaks were observed after the sintering at 800 degrees C for the sample milled for 30 h. Nb(3)Sn XRD peaks could be observed even before the heat treatment. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heat capacities of binary aqueous solutions of different concentrations of sucrose, glucose, fructose, citric acid, malic acid, and inorganic salts were measured with a differential scanning calorimeter in the temperature range from 5degreesC to 65degreesC. Heat capacity increased with increasing water content and increasing temperature. At low concentrations, heat capacity approached that of pure water, with a less pronounced effect of temperature, and similar abnormal behavior of pure water with a minimum around 30degreesC-40degreesC. Literature data, when available agreed relatively well with experimental values. A correction factor, based on the assumption of chemical equilibrium between liquid and gas phase in the Differential Scanning Calorimeter, was proposed to correct for the water evaporation due to temperature rise. Experimental data were fitted to predictive models. Excess molar heat capacity was calculated using the Redlich-Kister equation to represent the deviation from the additive ideal model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although its great potential as low to medium temperature waste heat recovery (WHR) solution, the ORC technology presents open challenges that still prevent its diffusion in the market, which are different depending on the application and the size at stake. Focusing on the micro range power size and low temperature heat sources, the ORC technology is still not mature due to the lack of appropriate machines and working fluids. Considering instead the medium to large size, the technology is already available but the investment is still risky. The intention of this thesis is to address some of the topical themes in the ORC field, paying special attention in the development of reliable models based on realistic data and accounting for the off-design performance of the ORC system and of each of its components. Concerning the “Micro-generation” application, this work: i) explores the modelling methodology, the performance and the optimal parameters of reciprocating piston expanders; ii) investigates the performance of such expander and of the whole micro-ORC system when using Hydrofluorocarbons as working fluid or their new low GWP alternatives and mixtures; iii) analyzes the innovative ORC reversible architecture (conceived for the energy storage), its optimal regulation strategy and its potential when inserted in typical small industrial frameworks. Regarding the “Industrial WHR” sector, this thesis examines the WHR opportunity of ORCs, with a focus on the natural gas compressor stations application. This work provides information about all the possible parameters that can influence the optimal sizing, the performance and thus the feasibility of installing an ORC system. New WHR configurations are explored: i) a first one, relying on the replacement of a compressor prime mover with an ORC; ii) a second one, which consists in the use of a supercritical CO2 cycle as heat recovery system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The heat exchanged at the low-temperature first-order magnetostructural transition is directly measured in Gd5Ge4 . Results show that the origin and the temperature dependence of the heat exchanged varies with the reversible/irreversible character of the first-order transition. In the reversible regime, the heat exchanged by the sample is mostly due to the latent heat at the transition and decreases with decreasing temperature, while in the irreversible regime, the heat is irreversibly dissipated and increases strongly with decreasing temperature, reaching a value of 237 J/kg at 4 K.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The heat exchanged at the low-temperature first-order magnetostructural transition is directly measured in Gd5Ge4 . Results show that the origin and the temperature dependence of the heat exchanged varies with the reversible/irreversible character of the first-order transition. In the reversible regime, the heat exchanged by the sample is mostly due to the latent heat at the transition and decreases with decreasing temperature, while in the irreversible regime, the heat is irreversibly dissipated and increases strongly with decreasing temperature, reaching a value of 237 J/kg at 4 K.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first feasibility study of using dual-probe heated fiber optics with distributed temperature sensing to measure soil volumetric heat capacity and soil water content is presented. Although results using different combinations of cables demonstrate feasibility, further work is needed to gain accuracy, including a model to account for the finite dimension and the thermal influence of the probes. Implementation of the dual-probe heat-pulse (DPHP) approach for measurement of volumetric heat capacity (C) and water content (θ) with distributed temperature sensing heated fiber optic (FO) systems presents an unprecedented opportunity for environmental monitoring (e.g., simultaneous measurement at thousands of points). We applied uniform heat pulses along a FO cable and monitored the thermal response at adjacent cables. We tested the DPHP method in the laboratory using multiple FO cables at a range of spacings. The amplitude and phase shift in the heat signal with distance was found to be a function of the soil volumetric heat capacity. Estimations of C at a range of moisture contents (θ = 0.09– 0.34 m3 m−3) suggest the feasibility of measurement via responsiveness to the changes in θ, although we observed error with decreasing soil water contents (up to 26% at θ = 0.09 m3 m−3). Optimization will require further models to account for the finite radius and thermal influence of the FO cables. Although the results indicate that the method shows great promise, further study is needed to quantify the effects of soil type, cable spacing, and jacket configurations on accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increasing interests in the use of starch as biodegradable plastic materials demand, amongst others, accurate information on thermal properties of starch systems particularly in the processing of thermoplastic starch (TPS), where plasticisers (water and glycerol) are added. The specific heat capacity of starch-water-glycerol mixtures was determined within a temperature range of 40-120degreesC. A modulated temperature differential scanning calorimeter (MTDSC) was employed and regression equations were obtained to predict the specific heat capacity as a function of temperature, water and glycerol content for four maize starches of differing amylose content (0 - 85%). Generally, temperature and water content are directly proportional to the specific heat capacity of the systems, but the influence of glycerol content on the thermal property varied according to the starch type.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increased device density, switching speeds of integrated circuits and decrease in package size is placing new demands for high power thermal-management. The convectional method of forced air cooling with passive heat sink can handle heat fluxes up-to 3-5W/cm2; however current microprocessors are operating at levels of 100W/cm2, This demands the usage of novel thermal-management systems. In this work, water-cooling systems with active heat sink are embedded in the substrate. The research involved fabricating LTCC substrates of various configurations - an open-duct substrate, the second with thermal vias and the third with thermal vias and free-standing metal columns and metal foil. Thermal testing was performed experimentally and these results are compared with CFD results. An overall thermal resistance for the base substrate is demonstrated to be 3.4oC/W-cm2. Addition of thermal vias reduces the effective resistance of the system by 7times and further addition of free standing columns reduced it by 20times.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background This study describes heat- and cold-related mortality in 12 urban populations in low- and middle-income countries, thereby extending knowledge of how diverse populations, in non-OECD countries, respond to temperature extremes. Methods The cities were: Delhi, Monterrey, Mexico City, Chiang Mai, Bangkok, Salvador, So Paulo, Santiago, Cape Town, Ljubljana, Bucharest and Sofia. For each city, daily mortality was examined in relation to ambient temperature using autoregressive Poisson models (2- to 5-year series) adjusted for season, relative humidity, air pollution, day of week and public holidays. Results Most cities showed a U-shaped temperature-mortality relationship, with clear evidence of increasing death rates at colder temperatures in all cities except Ljubljana, Salvador and Delhi and with increasing heat in all cities except Chiang Mai and Cape Town. Estimates of the temperature threshold below which cold-related mortality began to increase ranged from 15 degrees C to 29 degrees C; the threshold for heat-related deaths ranged from 16 degrees C to 31C. Heat thresholds were generally higher in cities with warmer climates, while cold thresholds were unrelated to climate. Conclusions Urban populations, in diverse geographic settings, experience increases in mortality due to both high and low temperatures. The effects of heat and cold vary depending on climate and non-climate factors such as the population disease profile and age structure. Although such populations will undergo some adaptation to increasing temperatures, many are likely to have substantial vulnerability to climate change. Additional research is needed to elucidate vulnerability within populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Directed evolution techniques have been used to improve the thermal stability of the xylanase A from Bacillus subtilis (XylA). Two generations of random mutant libraries generated by error prone PCR coupled with a single generation of DNA shuffling produced a series of mutant proteins with increasing thermostability. The most Thermostable XylA variant from the third generation contained four mutations Q7H, G13R, S22P, and S179C that showed an increase in melting temperature of 20 degrees C. The thermodynamic properties Of a representative subset of nine XylA variants showing a range of thermostabilities were measured by thermal denaturation as monitored by the change in the far ultraviolet circular dichroism signal. Analysis of the data from these thermostable variants demonstrated a correlation between the decrease in the heat capacity change (Delta C(p)) with an increase in the midpoint of the transition temperature (T(m)) on transition from the native to the unfolded state. This result could not be interpreted within the context of the changes in accessible surface area of the protein on transition from the native to unfolded states. Since all the mutations are located at the surface of the protein, these results suggest that an explanation of the decrease in Delta C(p) on should include effects arising from the prot inlsolvent interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

THESIS ABSTRACT : Low-temperature thermochronology relies on application of radioisotopic systems whose closure temperatures are below temperatures at which the dated phases are formed. In that sense, the results are interpreted as "cooling ages" in contrast to "formation ages". Owing to the low closure-temperatures, it is possible to reconstruct exhumation and cooling paths of rocks during their residence at shallow levels of the crust, i.e. within first ~10 km of depth. Processes occurring at these shallow depths such as final exhumation, faulting and relief formation are fundamental for evolution of the mountain belts. This thesis aims at reconstructing the tectono-thermal history of the Aar massif in the Central Swiss Alps by means of zircon (U-Th)/He, apatite (U-Th)/He and apatite fission track thermochronology. The strategy involved acquisition of a large number of samples from a wide range of elevations in the deeply incised Lötschen valley and a nearby NEAT tunnel. This unique location allowed to precisely constrain timing, amount and mechanisms of exhumation of the main orographic feature of the Central Alps, evaluate the role of topography on the thermochronological record and test the impact of hydrothermal activity. Samples were collected from altitudes ranging between 650 and 3930 m and were grouped into five vertical profiles on the surface and one horizontal in the tunnel. Where possible, all three radiometric systems were applied to each sample. Zircon (U-Th)/He ages range from 5.1 to 9.4 Ma and are generally positively correlated with altitude. Age-elevation plots reveal a distinct break in slope, which translates into exhumation rate increasing from ~0.4 to ~3 km/Ma at 6 Ma. This acceleration is independently confirmed by increased cooling rates on the order of 100°C/Ma constrained on the basis of age differences between the zircon (U-Th)/He and the remaining systems. Apatite fission track data also plot on a steep age-elevation curve indicating rapid exhumation until the end of the Miocene. The 6 Ma event is interpreted as reflecting tectonically driven uplift of the Aar massif. The late Miocene timing implies that the increase of precipitation in the Pliocene did not trigger rapid exhumation in the Aar massif. The Messinian salinity crisis in the Mediterranean could not directly intensify erosion of the Aar but associated erosional output from the entire Alps may have tapered the orogenic wedge and caused reactivation of thrusting in the Aar massif. The high exhumation rates in the Messinian were followed by a decrease to ~1.3 km/Ma as evidenced by ~8 km of exhumation during last 6 Ma. The slowing of exhumation is also apparent from apatite (U-Th)1He age-elevation data in the northern part of the Lötschen valley where they plot on a ~0.5km/Ma line and range from 2.4 to 6.4 Ma However, from the apatite (U-Th)/He and fission track data from the NEAT tunnel, there is an indication of a perturbation of the record. The apatite ages are youngest under the axis of the valley, in contrast to an expected pattern where they would be youngest in the deepest sections of the tunnel due to heat advection into ridges. The valley however, developed in relatively soft schists while the ridges are built of solid granitoids. In line with hydrological observations from the tunnel, we suggest that the relatively permeable rocks under the valley floor, served as conduits of geothermal fluids that caused reheating leading to partial Helium loss and fission track annealing in apatites. In consequence, apatite ages from the lowermost samples are too young and the calculated exhumation rates may underestimate true values. This study demonstrated that high-density sampling is indispensable to provide meaningful thermochronological data in the Alpine setting. The multi-system approach allows verifying plausibility of the data and highlighting sources of perturbation. RÉSUMÉ DE THÈSE : La thermochronologie de basse température dépend de l'utilisation de systèmes radiométriques dont la température de fermeture est nettement inférieure à la température de cristallisation du minéral. Les résultats obtenus sont par conséquent interprétés comme des âges de refroidissement qui diffèrent des âges de formation obtenus par le biais d'autres systèmes de datation. Grâce aux températures de refroidissement basses, il est aisé de reconstruire les chemins de refroidissement et d'exhumation des roches lors de leur résidence dans la croute superficielle (jusqu'à 10 km). Les processus qui entrent en jeu à ces faibles profondeurs tels que l'exhumation finale, la fracturation et le faillage ainsi que la formation du relief sont fondamentaux dans l'évolution des chaînes de montagne. Ces dernières années, il est devenu clair que l'enregistrement thermochronologique dans les orogènes peut être influencé par le relief et réinitialisé par l'advection de la chaleur liée à la circulation de fluides géothermaux après le refroidissement initial. L'objectif de cette thèse est de reconstruire l'histoire tectono-thermique du massif de l'Aar dans les Alpes suisses Centrales à l'aide de trois thermochronomètres; (U-Th)/He sur zircon, (U-Th)/He sur apatite et les traces de fission sur apatite. Afin d'atteindre cet objectif, nous avons récolté un grand nombre d'échantillons provenant de différentes altitudes dans la vallée fortement incisée de Lötschental ainsi que du tunnel de NEAT. Cette stratégie d'échantillonnage nous a permis de contraindre de manière précise la chronologie, les quantités et les mécanismes d'exhumation de cette zone des Alpes Centrales, d'évaluer le rôle de la topographie sur l'enregistrement thermochronologique et de tester l'impact de l'hydrothermalisme sur les géochronomètres. Les échantillons ont été prélevés à des altitudes comprises entre 650 et 3930m selon 5 profils verticaux en surface et un dans le tunnel. Quand cela à été possible, les trois systèmes radiométriques ont été appliqués aux échantillons. Les âges (U-Th)\He obtenus sur zircons sont compris entre 5.l et 9.4 Ma et sont corrélés de manière positive avec l'altitude. Les graphiques représentant l'âge et l'élévation montrent une nette rupture de la pente qui traduisent un accroissement de la vitesse d'exhumation de 0.4 à 3 km\Ma il y a 6 Ma. Cette accélération de l'exhumation est confirmée par les vitesses de refroidissement de l'ordre de 100°C\Ma obtenus à partir des différents âges sur zircons et à partir des autres systèmes géochronologiques. Les données obtenues par traces de fission sur apatite nous indiquent également une exhumation rapide jusqu'à la fin du Miocène. Nous interprétons cet évènement à 6 Ma comme étant lié à l'uplift tectonique du massif de l'Aar. Le fait que cet évènement soit tardi-miocène implique qu'une augmentation des précipitations au Pliocène n'a pas engendré cette exhumation rapide du massif de l'Aar. La crise Messinienne de la mer méditerranée n'a pas pu avoir une incidence directe sur l'érosion du massif de l'Aar mais l'érosion associée à ce phénomène à pu réduire le coin orogénique alpin et causer la réactivation des chevauchements du massif de l'Aar. L'exhumation rapide Miocène a été suivie pas une diminution des taux d'exhumation lors des derniers 6 Ma (jusqu'à 1.3 km\Ma). Cependant, les âges (U-Th)\He sur apatite ainsi que les traces de fission sur apatite des échantillons du tunnel enregistrent une perturbation de l'enregistrement décrit ci-dessus. Les âges obtenus sur les apatites sont sensiblement plus jeunes sous l'axe de la vallée en comparaison du profil d'âges attendus. En effet, on attendrait des âges plus jeunes sous les parties les plus profondes du tunnel à cause de l'advection de la chaleur dans les flancs de la vallée. La vallée est creusée dans des schistes alors que les flancs de celle-ci sont constitués de granitoïdes plus durs. En accord avec les observations hydrologiques du tunnel, nous suggérons que la perméabilité élevée des roches sous l'axe de la vallée à permi l'infiltration de fluides géothermaux qui a généré un réchauffement des roches. Ce réchauffement aurait donc induit une perte d'Hélium et un recuit des traces de fission dans les apatites. Ceci résulterait en un rajeunissement des âges apatite et en une sous-estimation des vitesses d'exhumation sous l'axe de la vallée. Cette étude à servi à démontrer la nécessité d'un échantillonnage fin et précis afin d'apporter des données thermochronologiques de qualité dans le contexte alpin. Cette approche multi-système nous a permi de contrôler la pertinence des données acquises ainsi que d'identifier les sources possibles d'erreurs lors d'études thermochronologiques. RÉSUMÉ LARGE PUBLIC Lors d'une orogenèse, les roches subissent un cycle comprenant une subduction, de la déformation, du métamorphisme et, finalement, un retour à la surface (ou exhumation). L'exhumation résulte de la déformation au sein de la zone de collision, menant à un raccourcissement et un apaissessement de l'édifice rocheux, qui se traduit par une remontée des roches, création d'une topographie et érosion. Puisque l'érosion agit comme un racloir sur la partie supérieure de l'édifice, des tentatives de corrélation entre les épisodes d'exhumation rapide et les périodes d'érosion intensive, dues aux changements climatiques, ont été effectuées. La connaissance de la chronologie et du lieu précis est d'une importance capitale pour une quelconque reconstruction de l'évolution d'une chaîne de montagne. Ces critères sont donnés par un retraçage des changements de la température de la roche en fonction du temps, nous donnant le taux de refroidissement. L'instant auquel les roches ont refroidit, passant une certaine température, est contraint par l'application de techniques de datation par radiométrie. Ces méthodes reposent sur la désintégration des isotopes radiogéniques, tels que l'uranium et le potassium, tous deux abondants dans les roches de la croûte terrestre. Les produits de cette désintégration ne sont pas retenus dans les minéraux hôtes jusqu'au moment du refroidissement de la roche sous une température appelée 'de fermeture' , spécifique à chaque système de datation. Par exemple, la désintégration radioactive des atomes d'uranium et de thorium produit des atomes d'hélium qui s'échappent d'un cristal de zircon à des températures supérieures à 200°C. En mesurant la teneur en uranium-parent, l'hélium accumulé et en connaissant le taux de désintégration, il est possible de calculer à quel moment la roche échantillonnée est passée sous la température de 200°C. Si le gradient géothermal est connu, les températures de fermeture peuvent être converties en profondeurs actuelles (p. ex. 200°C ≈ 7km), et le taux de refroidissement en taux d'exhumation. De plus, en datant par système radiométrique des échantillons espacés verticalement, il est possible de contraindre directement le taux d'exhumation de la section échantillonnée en observant les différences d'âges entre des échantillons voisins. Dans les Alpes suisses, le massif de l'Aar forme une structure orographique majeure. Avec des altitudes supérieures à 4000m et un relief spectaculaire de plus de 2000m, le massif domine la partie centrale de la chaîne de montagne. Les roches aujourd'hui exposées à la surface ont été enfouies à plus de 10 km de profond il y a 20 Ma, mais la topographie actuelle du massif de l'Aar semble surtout s'être développée par un soulèvement actif depuis quelques millions d'années, c'est-à-dire depuis le Néogène supérieur. Cette période comprend un changement climatique soudain ayant touché l'Europe il y a environ 5 Ma et qui a occasionné de fortes précipitations, entraînant certainement une augmentation de l'érosion et accélérant l'exhumation des Alpes. Dans cette étude, nous avons employé le système de datation (U-TH)/He sur zircon, dont la température de fermeture de 200°C est suffisamment basse pour caractériser l'exhumation du Néogène sup. /Pliocène. Les échantillons proviennent du Lötschental et du tunnel ferroviaire le plus profond du monde (NEAT) situé dans la partie ouest du massif de l'Aar. Considérés dans l'ensemble, ces échantillons se répartissent sur un dénivelé de 3000m et des âges de 5.1 à 9.4 Ma. Les échantillons d'altitude supérieure (et donc plus vieux) documentent un taux d'exhumation de 0.4 km/Ma jusqu'à il y a 6 Ma, alors que les échantillons situés les plus bas ont des âges similaires allant de 6 à 5.4 Ma, donnant un taux jusqu'à 3km /Ma. Ces données montrent une accélération dramatique de l'exhumation du massif de l'Aar il y a 6 Ma. L'exhumation miocène sup. du massif prédate donc le changement climatique Pliocène. Cependant, lors de la crise de salinité d'il y a 6-5.3 Ma (Messinien), le niveau de la mer Méditerranée est descendu de 3km. Un tel abaissement de la surface d'érosion peut avoir accéléré l'exhumation des Alpes, mais le bassin sud alpin était trop loin du massif de l'Aar pour influencer son érosion. Nous arrivons à la conclusion que la datation (U-Th)/He permet de contraindre précisément la chronologie et l'exhumation du massif de l'Aar. Concernant la dualité tectonique-érosion, nous suggérons que, dans le cas du massif de l'Aar, la tectonique prédomine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molar heat capacities of the binary compounds NiAl, NiIn, NiSi, NiGe, NiBi, NiSb, CoSb and FeSb were determined every 10 K by differential scanning calorimetry in the temperature range 310-1080 K. The experimental results have been fitted versus temperature according to C-p = a + b . T + c . T-2 + d . T-2. Results are given, discussed and compared to estimations found in the literature. Two compounds, NiBi and FeSb, are subject to transformations between 460 and 500 K. (C) 1999 Elsevier Science Ltd. All rights reserved.