950 resultados para in-cylinder pressure
Resumo:
In-cylinder pressure transducers have been used for decades to record combustion pressure inside a running engine. However, due to the extreme operating environment, transducer design and installation must be considered in order to minimize measurement error. One such error is caused by thermal shock, where the pressure transducer experiences a high heat flux that can distort the pressure transducer diaphragm and also change the crystal sensitivity. This research focused on investigating the effects of thermal shock on in-cylinder pressure transducer data quality using a 2.0L, four-cylinder, spark-ignited, direct-injected, turbo-charged GM engine. Cylinder four was modified with five ports to accommodate pressure transducers of different manufacturers. They included an AVL GH14D, an AVL GH15D, a Kistler 6125C, and a Kistler 6054AR. The GH14D, GH15D, and 6054AR were M5 size transducers. The 6125C was a larger, 6.2mm transducer. Note that both of the AVL pressure transducers utilized a PH03 flame arrestor. Sweeps of ignition timing (spark sweep), engine speed, and engine load were performed to study the effects of thermal shock on each pressure transducer. The project consisted of two distinct phases which included experimental engine testing as well as simulation using a commercially available software package. A comparison was performed to characterize the quality of the data between the actual cylinder pressure and the simulated results. This comparison was valuable because the simulation results did not include thermal shock effects. All three sets of tests showed the peak cylinder pressure was basically unaffected by thermal shock. Comparison of the experimental data with the simulated results showed very good correlation. The spark sweep was performed at 1300 RPM and 3.3 bar NMEP and showed that the differences between the simulated results (no thermal shock) and the experimental data for the indicated mean effective pressure (IMEP) and the pumping mean effective pressure (PMEP) were significantly less than the published accuracies. All transducers had an IMEP percent difference less than 0.038% and less than 0.32% for PMEP. Kistler and AVL publish that the accuracy of their pressure transducers are within plus or minus 1% for the IMEP (AVL 2011; Kistler 2011). In addition, the difference in average exhaust absolute pressure between the simulated results and experimental data was the greatest for the two Kistler pressure transducers. The location and lack of flame arrestor are believed to be the cause of the increased error. For the engine speed sweep, the torque output was held constant at 203 Nm (150 ft-lbf) from 1500 to 4000 RPM. The difference in IMEP was less than 0.01% and the PMEP was less than 1%, except for the AVL GH14D which was 5% and the AVL GH15DK which was 2.25%. A noticeable error in PMEP appeared as the load increased during the engine speed sweeps, as expected. The load sweep was conducted at 2000 RPM over a range of NMEP from 1.1 to 14 bar. The difference in IMEP values were less 0.08% while the PMEP values were below 1% except for the AVL GH14D which was 1.8% and the AVL GH15DK which was at 1.25%. In-cylinder pressure transducer data quality was effectively analyzed using a combination of experimental data and simulation results. Several criteria can be used to investigate the impact of thermal shock on data quality as well as determine the best location and thermal protection for various transducers.
Resumo:
Zero-carbon powertrains development has become one of the main challenges for automotive industries around the world. Following this guideline, several approaches such as powertrain electrification, advanced combustions, and hydrogen internal combustion engines have been aimed to achieve the goal. Low Temperature Combustions, characterized by a simultaneous reduction of fuel consumption and emissions, represent one of the most studied solutions moving towards a sustainable mobility. Previous research demonstrate that Gasoline partially premixed Compression Ignition combustion is one of the most promising LTC. Mainly characterized by the high-pressure direct-injection of gasoline and the spontaneous ignition of the premixed air-fuel mixture, GCI combustion has shown a good potential to achieve the high thermal efficiency and low pollutants in compression ignited engines required by future emission regulations. Despite its potential, GCI combustion might suffer from low combustion controllability and stability, because gasoline spontaneous ignition is significantly affected by slight variations of the local in-cylinder thermal conditions. Therefore, to properly control GCI combustion assuring the maximum performance, a deep knowledge of the combustion process, i.e., gasoline auto-ignition and the effect of the control parameters on the combustion and pollutants, is mandatory. This PhD dissertation focuses on the study of GCI combustion in a light-duty compression ignited engine. Starting from a standard 1.3L diesel engine, this work describes the activities made moving toward the full conversion of the engine. A preliminary study of the GCI combustion was conducted in a “Single-Cylinder” engine configuration highlighting combustion characteristics and dependencies on the control parameters. Then, the full engine conversion was performed, and a wide experimental campaign allowed to confirm the benefits of this advanced combustion methodologies in terms of pollutants and thermal efficiency. The analysis of the in-cylinder pressure signal allowed to study in depth the GCI combustion and develop control-oriented models aimed to improve the combustion stability.
Resumo:
Background: We aimed to compare plasma concentrations of carbon dioxide (CO(2)) in dogs that underwent intra- and preperitoneal CO(2) insufflation. Materials and Methods: Thirty dogs were studied. Ten formed a control group, 10 underwent intraperitoneal CO(2) insufflation, and 10 underwent preperitoneal CO(2) insufflation. General anesthesia with controlled ventilation was standardized for all dogs. After stabilizing the anesthesia, blood samples were collected at predetermined times and were sent for immediate gasometric analysis. Analysis of variance was used for comparing variables. Results: The plasma CO(2) concentration in the intraperitoneal insufflation group increased significantly more than in the preperitoneal insufflation group and was significantly greater than in the control group (P < 0.05). The pH values in the intraperitoneal group were lower than in the preperitoneal group (P < 0.05). Conclusion: The data from this study suggest that a greater plasma concentration of CO(2) is achieved by insufflation at constant pressure into the intraperitoneal space than into the preperitoneal space.
Resumo:
This study examines the applicability of a micromechanics approach based upon the computational cell methodology incorporating the Gurson-Tvergaard (GT) model and the CTOA criterion to describe ductile crack extension of longitudinal crack-like defects in high pressure pipeline steels. A central focus is to gain additional insight into the effectiveness and limitations of both approaches to describe crack growth response and to predict the burst pressure for the tested cracked pipes. A verification study conducted on burst testing of large-diameter, precracked pipe specimens with varying crack depth to thickness ratio (a/t) shows the potential predictive capability of the cell approach even though both the CT model and the CTOA criterion appear to depend on defect geometry. Overall, the results presented here lend additional support for further developments in the cell methodology as a valid engineering tool for integrity assessments of pipelines with axial defects. (C) 2011 Elsevier Ltd. All rights reserved,
Resumo:
An experiment was implemented to study fluid flow in a pressure media. This procedure successfully combines nuclear magnetic resonance imaging with a pressure membrane chamber in order to visualize the non-wetting and wetting fluid flows with controlled boundary conditions. A specially designed pressure membrane chamber, made of non-magnetic materials and able to withstand 4 MPa, was designed and built for this purpose. These two techniques were applied to the drainage of Douglas fir sapwood. In the study of the longitudinal flow, narrow drainage fingers are formed in the latewood zones. They follow the longitudinal direction of wood and spread throughout the sample length. These fingers then enlarge in the cross-section plane and coalesce until drainage reaches the whole latewood part. At the end of the experiments, when the drainage of liquid water in latewood is completed, just a few sites of percolation appear in earlywood zones. This difference is a result of the wood anatomical structure, where pits, the apertures that allow the sap to flow between wood cells, are more easily aspirated in earlywood than in latewood. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The tensions produced in the wall of a rigid, thin-walled, liquid-filled sphere as it moves with an axisymmetric straining flow are examined. This problem has not been previously addressed. A generalised correlation for the maximum wall tension, expressed in dimensionless form as a Weber number (We), is developed in terms of the acceleration number (Ac) and Reynolds number (Re) of the straining flow. At low Reynolds number We is dominated by viscous forces, while inertial forces due to internal pressure gradients caused by sphere acceleration dominate at higher Re. The generalised correlation has been used to examine the case of a typical yeast cell (a thin-walled, liquid-filled sphere) passing through a typical high-pressure homogeniser (a straining-flow device). At 56 MPa homogenising pressure, a 6 mu m yeast cell experiences tensions in the inertially dominated regime (Re = 100). The correlation gives We = 0.206, corresponding to a maximum wall tension of 8 Nm(-1). This is equivalent to an applied compressive force of 150 mu N and compares favourably with the force required to break yeast cells under compressive micromanipulation (40-90 mu N). Inertial forces may therefore be an important and previously unrecognised. mechanism of microbial cell disruption during high-pressure homogenisation. Further work is required to examine the likelihood of cell deformation in the high-strain-rate short-residence-time environment of the homogeniser, and the effect that such deformation may have on the contribution of inertial forces to disruption. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Background. It is not known if the adjustment of antihypertensive therapy based on home blood pressure monitoring (HBPM) can improve blood pressure (BP) control among haemodialysis patients. Methods. This is an open randomized clinical trial. Hypertensive patients on haemodialysis were randomized to have the antihypertensive therapy adjusted based on predialysis BP measurements or HBPM. Before and after 6 months of follow-up, patients were submitted to ambulatory blood pressure monitoring (ABPM) for 24 h, HBPM during 1 week and echocardiogram. Results. A total of 34 and 31 patients completed the study in the HBPM and predialysis BP groups, respectively. At the end of study, the systolic (SBP) and diastolic (DBP) blood pressure during the interdialytic period measured by ABPM were significantly lower in the HBPM group in relation to the predialysis BP group (mean 24-h BP: 135 +/- 12 mmHg/76 +/- 7 mmHg versus 147 +/- 15 mmHg/79 +/- 8 mmHg; P < 0.05). In the HBPM analysis, the HBPM group showed a significant reduction only in SBP compared to the predialysis BP group (weekly mean: 144 +/- 21 mmHg versus 154 +/- 22 mmHg; P < 0.05). There were no differences between the HBPM and predialysis BP groups in relation to the left ventricular mass index at the end of the study (108 +/- 35 g/m(2) versus 110 +/- 33 g/m(2); P > 0.05). Conclusions. Decision making based on HBPM among haemodialysis patients has led to a better BP control during the interdialytic period in comparison with predialysis BP measurements. HBPM may be a useful adjuvant instrument for blood pressure control among haemodialysis patients.
Resumo:
Objective Cardiovascular risk factors were surveyed in two Indian populations (Guarani, n=60; Tupinikin, n=496) and in a non-Indian group (n=114) living in the same reserve in southeast Brazilian coast. The relationship between an age-dependent blood pressure (BP) increase with salt consumption was also investigated. Methods Overnight (12 h) urine was collected to evaluate Na excretion. Fasting glucose and lipids, anthropometry, BP, ECG and carotid-femoral pulse wave velocity (PWV) were measured in a clinic visit. Participation (318 men/352 women, age 20-94 years; mean=37.6 +/- 14.9 years) comprised 80% of the eligible population. Results The prevalence of hypertension, diabetes and high cholesterol was similar in Tupinikins and in non-Indians and higher than in Guaranis. The prevalence of smoking and obesity was higher in the latter group. Hypertension and diabetes were detected in only one individual of the Guarani group. Mean BP adjusted to age and BMI was significantly lower (P<0.01) in Guaranis (82.8 +/- 1.6 mmHg) than in Tupinikins (92.3 +/- 0.5 mmHg) and non-Indians (91.6 +/- 1.1 mmHg). Urinary Na excretion (mEq/12h), however, was similar in the three groups (Guarani=94 +/- 40; Tupinikin=105 +/- 56; non-Indian=109 +/- 55; P>0.05). PWV (m/s) was lower (P<0.01) in Guarani (7.5 +/- 1.4) than in Tupinikins (8.8 +/- 2.2) and non-Indians (8.4 +/- 2.0). Multiple regression analysis showed that age and waist-to-hip ratio (WHR) were independent predictors of SBP and DBP (r(2)=0.44) in Tupinikins, whereas the WHR was the unique independent predictor of BP variability in Guaranis (r(2)=0.22). Conclusion Lower BP levels in Guaranis cannot be explained by low salt intake observed in other primitive populations. J Hypertens 27:1753-1760 (C) 2009 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
GABAergic, nitrergic and glutamatergic mechanisms in the PVN on the baseline mean arterial pressure (MAP), heart rate (HR) and on the cardiovascular responses to chemoreflex activation in awake rat were evaluated. Chemoreflex was activated with KCN before and after microinjections into the PVN. Bicuculline into the PVN increased baseline MAP (94+/-3 vs 113+/-5 mmHg) and HR (350+/-9 vs 439+/-18 bpm) but had no effect on the pressor (49+/-5 vs 47+/-6 mmHg) or bradicardic (-213+/-23 vs -256+/-42 bpm) responses (n=7). Kynurenic acid into the PVN (n=6) produced no significant changes in the MAP (98+/-3 vs 100+/-3 mmHg), HR (330+/-5 vs 339+/-12 mmHg) or in the pressor (50+/-4 vs 42+/-4 mmHg) and bradicardic (-252+/-4 vs -285+/-16 bpm) responses to chemoreflex. L-NAME into the PVN (n=8) produced increase in the MAP (94+/-3 vs 113+/-5 mmHg) and HR (350+/-9 vs 439+/-18 bpm) but had no effect on the pressor (52+/-5 vs 47+/-6 mmHg) or bradicardic (-253+/-19 vs -320+/-25 bpm) responses to chemoreflex. We conclude that GABA(A) and nitric oxide in the PVN are involved in the maintenance of the baseline MAP but not in the modulation of the responses to chemoreflex. The results also show that Glutamate receptors in the PVN are not involved in maintenance of the baseline MAP, HR or in the cardiovascular responses to chemoreflex in awake rats. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
1. An elevation in blood pressure has been consistently observed 24 h after adrenocorticotropic hormone (ACTH) administration and is caused by increased ACTH-stimulated cortisol secretion, in association with increased cardiac output. The aim of the present study was to investigate the previously undefined time of onset of this increase in blood pressure in normal humans. 2. Ten normal healthy volunteers received 250 mug ACTH-[1-24], in 500 mL normal saline, infused at a constant rate over 8 h. Six subjects also received a placebo infusion (normal saline only). Blood pressure, heart rate and cortisol levels were determined hourly. Adrenocorticotropic hormone (ACTH-[1-24] plus native ACTH) was measured at 0, 1, 7 and 8 h. 3. Infusion of ACTH-[1-24] produced maximal secretion rates of cortisol, resulting in a mean peak plasma level of 985 +/- 46 nmol/L at 8 h. In response, blood pressure and heart rate rose significantly by 2 h and remained generally elevated for the duration of the infusion. 4. The early onset of haemodynamic responses is consistent with classical steroid receptor-mediated genomic mechanisms, but could be due non-genomic mechanisms. 5. The cardiovascular consequences of therapeutic use of ACTH are well recognized. This results of the present study suggest that even diagnostic administration of ACTH, delivered over a few hours, may raise blood pressure.
Resumo:
OBJECTIVE: To assess the influence of the quality of sleep on the nocturnal physiological drop in blood pressure during ambulatory blood pressure monitoring. METHODS: We consecutively assessed ambulatory blood pressure monitoring, the degree of tolerance for the examination, and the quality of sleep in 168 patients with hypertension or with the suspected "white-coat" effect. Blood pressure fall during sleep associated with a specific questionnaire and an analogical visual scale of tolerance for ambulatory blood pressure monitoring were used to assess usual sleep and sleep on the day of examination. Two specialists in sleep disturbances classified the patients into 2 groups: those with normal sleep and those with abnormal sleep. RESULTS: Fifty-nine (35 %) patients comprised the abnormal sleep group. Findings regarding the quality of sleep on the day of ambulatory blood pressure monitoring as compared with those regarding the quality of sleep on a usual day were different and were as follows, respectively: total duration of sleep (-12.4±4.7 versus -42.2±14.9 minutes, P=0.02), latency of sleep (0.4±2.7 versus 17±5.1 minutes, P<0.001), number of awakenings (0.1±0.1 versus 1.35±0.3 times, P<0.001), and tolerance for ambulatory blood pressure monitoring (8±0.2 versus 6.7±0.35, P=0.035). An abnormal drop in blood pressure during sleep occurred in 20 (18%) patients in the normal sleep group and in 14 (24%) patients in the abnormal sleep group, P=0.53. CONCLUSION: Ambulatory blood pressure monitoring causes sleep disturbances in some patients, and a positive association between quality of sleep and tolerance for the examination was observed.
Resumo:
Hypertension (HTN) is a major risk factor for cardiovascular mortality, yet only a small proportion of hypertensive individuals receive appropriate therapy and achieve target blood pressure (BP) values. Factors influencing the success of antihypertensive therapy include physicians' acceptance of guideline BP targets, the efficacy and tolerability of the drug regimen, and patient compliance and persistence with therapy. It is now well recognised that most hypertensive patients require at least two antihypertensive agents to achieve their target BP. However, complicated treatment regimens are a major contributory factor to poor patient compliance. The use of combination therapy for HTN offers a number of advantages over the use of monotherapy, including improved efficacy, as drug combinations with a synergistic mechanism of action can be used. This additive effect means that lower doses of the individual components can be used, which may translate into a decreased likelihood of adverse events. The use of single-pill combination therapy, in which two or more agents are combined in a single dosage form, offers all the benefits of free combination therapy (improved efficacy and tolerability over monotherapy) together with the added benefit of improved patient compliance because of the simplified treatment regimen. The use of single-pill combination therapy may also be associated with cost savings compared with the use of free combinations for reasons of cheaper drug costs, fewer physician visits and fewer hospitalisations for uncontrolled HTN and cardiovascular events. Thus, the use of single-pill combination therapy for HTN should help improve BP goal attainment through improved patient compliance, leading to reduced costs for cardiovascular-related care.
Resumo:
To study the functional role of individual alpha1-adrenergic (AR) subtypes in blood pressure (BP) regulation, we used mice lacking the alpha1B-AR and/or alpha1D-AR with the same genetic background and further studied their hemodynamic and vasoconstrictive responses. Both the alpha1D-AR knockout and alpha1B-/alpha1D-AR double knockout mice, but not the alpha1B-AR knockout mice, had significantly (p < 0.05) lower levels of basal systolic and mean arterial BP than wild-type mice in nonanesthetized condition, and they showed no significant change in heart rate or in cardiac function, as assessed by echocardiogram. All mutants showed a significantly (p < 0.05) reduced catecholamine-induced pressor and vasoconstriction responses. It is noteworthy that the infusion of norepinephrine did not elicit any pressor response at all in alpha1B-/alpha1D-AR double knockout mice. In an attempt to further examine alpha1-AR subtype, which is involved in the genesis or maintenance of hypertension, BP after salt loading was monitored by tail-cuff readings and confirmed at the endpoint by direct intra-arterial recording. After salt loading, alpha1B-AR knockout mice developed a comparable level of hypertension to wild-type mice, whereas mice lacking alpha1D-AR had significantly (p < 0.05) attenuated BP and lower levels of circulating catecholamines. Our data indicated that alpha1B- and alpha1D-AR subtypes participate cooperatively in BP regulation; however, the deletion of the functional alpha1D-AR, not alpha1B-AR, leads to an antihypertensive effect. The study shows differential contributions of alpha1B- and alpha1D-ARs in BP regulation.
Resumo:
Résumé en français: Il est admis que l'inflation d'une manchette à pression au niveau du bras engendre une augmentation réactionnelle de la tension artérielle qui peut être le résultat d'une gêne lors de l'inflation et peut diminuer la précision de la mesure. Dans cette étude, nous comparons séquentiellement l'augmentation de la tension artérielle lorsque la manchette à pression est positionnée au niveau du bras et au niveau du poignet. Nous avons étudié un collectif de 34 participants normotendus et 34 patients hypertendus. Chacun d'eux était équipé de deux manchettes à pression, l'une au niveau du bras et l'autre au niveau du poignet. Nous avons randomisé l'ordre d'inflation des manchettes ainsi que la pression d'inflation maximale (180mmHg versus 240mmHg). Trois mesures étaient effectuées pour chaque pression d'inflation maximale, ceci au bras comme poignet, et leur séquence était également randomisée. En parallèle, un enregistrement continu de la tension artérielle avait lieu au niveau du majeur de la main opposée à l'aide d'un photoplethysmographe. Cette valeur était considérée comme la valeur de tension artérielle au repos. Pour les participants normotendus, aucune différence statistiquement significative n'a pu être mise en évidence en lien avec la position de la manchette à pression, ceci indépendamment de la pression d'inflation maximale. Variation de la pression systolique à 180 mmHg: 4.3+/-3.0 mmHg au bras et 3.7+/-2.9 mmHg au poignet (p=ns), à 240 mmHg: 5.5+/-3.9 au bras et 4.2+/-2.7 mmHg au poignet (p=0.052). En revanche, concernant les patients hypertendus, une augmentation significative de la tension artérielle a été mise en évidence entre le bras et le poignet. Ceci pour les valeurs de tension artérielle systolique et diastolique et quelle que soit la pression d'inflation maximale utilisée. Augmentation de la pression artérielle systolique 6.513.5 mmHg au bras et 3.812.1mmHg au poignet pour une pression d'inflation maximale de 180 mmHg (p<0.01) et respectivement 6.413.5 mmHg et 4.713.0 mmHg pour 240 mmHg (p=0.01). L'augmentation des valeurs de tension artérielle était indépendante de la valeur tensionnelle de base. Ces résultats montrent que les patients hypertendus réagissent significativement moins à l'inflation d'une manchette ä pression lorsque celle-ci est positionnée au niveau du poignet par rapport au bras, ceci indépendamment des valeurs de tension artérielle de base des patients. Nous pouvons donc suggérer que l'inflation d'une manchette à pression cause moins de désagrément lorsqu'elle est placée au niveau du poignet, notamment chez les patients hypertendus et qu'elle peut être une alternative à la mesure standard au niveau du bras.