999 resultados para foreign material
Resumo:
To judge the possibilities of detection of orbital foreign bodies in multidetector CT (MDCT) with a focus on glass slivers.
Resumo:
Foreign body aspiration (FBA) is one of leading causes of death in children, especially among those younger than 3 years of age. The inhalation of a foreign body may cause a wide variety of symptoms, and early diagnosis is highly associated with the successful removal of the inhaled foreign material. Despite the great advances in endoscopic procedures and anesthesia, a large number of difficulties and complications still result from foreign body aspiration. We describe 5 cases of serious acute complications following aspiration of foreign bodies that became lodged in the tracheobronchial tree, including pneumomediastinum, pneumothorax, total atelectasis, foreign body dislodgment, and need for thoracotomy in children admitted into our intensive care unit in 1999 and 2000; these were all situations that could have been prevented with early recognition and prompt therapeutic intervention.
Resumo:
This thesis is done as a part of project called FuncMama that is a project between Technical Research Centre of Finland (VTT), Oulu University (OY), Lappeenranta University of Technology (LUT) and Finnish industrial partners. Main goal of the project is to manufacture electric and mechanical components from mixed materials using laser sintering. Aim of this study was to create laser sintered pieces from ceramic material and monitor the sintering event by using spectrometer. Spectrometer is a device which is capable to record intensity of different wavelengths in relation with time. In this study the monitoring of laser sintering was captured with the equipment which consists of Ocean Optics spectrometer, optical fiber and optical lens (detector head). Light from the sintering process hit first to the lens system which guides the light in to the optical fibre. Optical fibre transmits the light from the sintering process to the spectrometer where wavelengths intensity level information is detected. The optical lens of the spectrometer was rigidly set and did not move along with the laser beam. Data which was collected with spectrometer from the laser sintering process was converted with Excel spreadsheet program for result’s evaluation. Laser equipment used was IPG Photonics pulse fibre laser. Laser parameters were kept mainly constant during experimental part and only sintering speed was changed. That way it was possible to find differences in the monitoring results without fear of too many parameters mixing together and affecting to the conclusions. Parts which were sintered had one layer and size of 5 x 5 mm. Material was CT2000 – tape manufactured by Heraeus which was later on post processed to powder. Monitoring of different sintering speeds was tested by using CT2000 reference powder. Moreover tests how different materials effect to the process monitoring were done by adding foreign powder Du Pont 951 which had suffered in re-grinding and which was more reactive than CT2000. By adding foreign material it simulates situation where two materials are accidently mixed together and it was studied if that can be seen with the spectrometer. It was concluded in this study that with the spectrometer it is possible to detect changes between different laser sintering speeds. When the sintering speed is lowered the intensity level of light is higher from the process. This is a result of higher temperature at the sintering spot and that can be noticed with the spectrometer. That indicates it could be possible to use spectrometer as a tool for process observation and support the idea of having system that can help setting up the process parameter window. Also important conclusion was how well the adding of foreign material could be seen with the spectrometer. When second material was added a significant intensity level raise could be noticed in that part where foreign material was mixed. That indicates it is possible to see if there are any variations in the material or if there are more materials mixed together. Spectrometric monitoring of laser sintering could be useful tool for process window observation and temperature controlling of the sintering process. For example if the process window for specific material is experimentally determined to get wanted properties and satisfying sintering speed. It is possible if the data is constantly recorded that the results can show faults in the part texture between layers. Changes between the monitoring data and the experimentally determined values can then indicate changes in the material being generated by material faults or by wrong process parameters. The results of this study show that spectrometer could be one possible tool for monitoring. But to get in that point where this all can be made possible much more researching is needed.
Resumo:
Two cases of swallowing of foreign material related to dental implants during dental practice are described. A conservative approach by clinical-radiographic follow-up was performed in both cases; however, one of the patients required colonoscopy under general anesthesia for the removal of the impacted foreign body from the intestinal region. These complications not only have associated economic cost but also carry the risk of malpractice litigation against the professional; thus, the surgeon was responsible for all the costs of hospital and surgery management of this case. Details of the clinical signs, radiographic examinations, type of treatment, and follow-up are presented.
Resumo:
A mycotic pseudoaneurysm of the popliteal artery is usually a consequence of septic embolization and often a result of bacterial endocarditis. Conventional treatment is surgical and avoids the placement of foreign material in infected sites. Here we report our treatment of a 59-year-old man who presented with a rupture of a mycotic pseudoaneurysm of the popliteal artery due to septic embolism from sternoclavicular infectious arthritis. Radiological investigations are included. This is the first documented case of septic arthritis complicated by a rupture of a mycotic popliteal false aneurysm and treated using an endovascular procedure. Combining endovascular stent grafts with evacuation of the joint abscess and antibiotic therapy can offer a safe alternative for frail and unstable patients.
Resumo:
A bioresorbable membrane made of sodium hyaluronate and carboxymethycellulose, has been reported to prevent peritoneal adhesion. This study was designed to test its efficiency in the prevention of pericardial adhesions. Two groups of six pigs (mean weight 72 +/- 8 kg) were chosen for the experiment. The heart was exposed through a left thoracotomy and a wide patch of pericardium was excised. In the test group (n = 6), the left ventricular area without pericardium was divided into two areas: area A where six stitches of Prolene were performed, and area B which was left intact. The membrane was applied on the both areas as well as on the adjacent area covered with pericardium (area C). In the control group (n = 6), the same protocol was performed except for the membrane application. The animals were sacrificed one month later. The adhesion status as well as the visibility of the coronary anatomy was assessed according to severity scores ranging from 0 to 3 for the adhesions and from 0 to 2 for the visibility. The difference between groups was considered significant when p < 0.05. The adhesion score of the area A was 1.7 +/- 0.5 in the test group versus 2.5 +/- 0.5 in the control group (p = 0.02) and the visibility score was 1.3 +/- 0.8 and 2 +/- 0 respectively (p = 0.07). In the area B, the adhesion score was 1 +/- 0 in the test group versus 2 +/- 0.6 in the control group (p = 0.03) and the visibility score was 0.7 +/- 0.5 and 2 +/- 0 respectively (p = 0.001). Lastly, in the area C, the adhesion score was 1 +/- 0 in both groups (n.s.) and the visibility score was 0.7 +/- 0.4 in the test group versus 0.5 +/- 0.5 in the control group (n.s.). In this animal model, the role of the bioresorbable membrane in the prevention of pericardial adhesions is limited to the areas without pericardial cover and without foreign material. The presence of foreign material neutralizes its effect.
Resumo:
BACKGROUND: Vascular reconstructions are becoming challenging due to the comorbidity of the aging population and since the introduction of minimally invasive approaches. Many sutureless anastomosis devices have been designed to facilitate the cardiovascular surgeon's work and the vascular join (VJ) is one of these. We designed an animal study to assess its reliability and long-term efficacy. METHODS: VJ allows the construction of end-to-end and end-to-side anastomoses. It consists of two metallic crowns fixed to the extremity of the two conduits so that vessel edges are joined layer by layer. There is no foreign material exposed to blood. In adult sheep both carotid arteries were prepared and severed. End-to-end anastomoses were performed using the VJ device on one side and the classical running suture technique on the other side. Animals were followed-up with Duplex-scan every 3 months and sacrificed after 12 months. Histopathological analysis was carried out. RESULTS: In 20 animals all 22 sutureless anastomoses were successfully completed in less than 2 min versus 6 +/- 3 min for running suture. Duplex showed the occlusion of three controls and one sutureless anastomosis. Two controls and one sutureless had stenosis >50%. Histology showed very thin layer of myointimal hyperplasia (50 +/- 10 microm) in the sutureless group versus 300 +/- 27 microm in the control. No significant inflammatory reaction was detected. CONCLUSIONS: VJ provides edge-to-edge vascular repair that can be considered the most physiological way to restore vessel continuity. For the first time, in healthy sheep, an anastomotic device provided better results than suture technique.
Resumo:
Ydinvoimateollisuudessa irtokappaleella tarkoitetaan prosessiin kuulumatonta materiaalia, joka ei luonnostaan kuulu prosessiin ja jolla prosessiin jäädessään voi olla haitallinen vaikutus sen toimintaan, komponentteihin tai kemiaan. Irtokappaleet voivat aiheuttaa monenlaisia haittoja ydinvoimalaitoksen turvalliselle ja taloudelliselle käytölle. Vaikka ydinvoimalaitoksen käytössä turvallisuus on aina etusijalla, negatiiviset vaikutukset turvallisuuteen heijastuvat usein myös talouteen. Diplomityössä arvioitiin erilaisia irtokappaleiden aiheuttamia riskejä ydinvoimalan toiminnalle käyttötapahtumia analysoimalla. Erilaisiin tapahtumiin, niiden aiheuttajiin ja vaikutusmekanismeihin tutustumisen jälkeen tutkittiin Loviisan voimalaitoksen käyttämiä toimintatapoja irtokappaleiden hallitsemiseksi. Irtokappaleiden hallintaan pyritään sekä hallinnollisilla että käytännön menetelmillä. Hallinnollisia menetelmiä ovat esimerkiksi ohjeistojärjestelmä ja johtaminen, käytännön menettelytapoja esimerkiksi työtavat ja koulutus. Irtokappaleiden hallinnan menetelmiin tutustuttiin sekä tehoajolla että vuosihuollon aikana. Nykytilan arvioinnin perusteella esitettiin toimenpide-ehdotuksia irtokappaleiden hallinnan kehittämiseksi. Toimenpide-ehdotukset muodostettiin sekä korjaamaan havaittuja haavoittuvuuksia että kehittämään toimintaa kansainvälisesti hyviksi tunnistettujen käytäntöjen mukaisiksi.
Resumo:
Quite a few texts from England were translated into Irish in the fifteenth and early-sixteenth centuries. The number of these texts was significant enough to suggest that foreign material of this sort enjoyed something of a vogue in late-medieval Ireland. Translated texts include Mandeville’s Travels, Guy of Warwick, Bevis of Hampton, Fierabras and a selection of saints’ lives. Scholars have paid little attention to the origins and initial readerships of these texts, but still less research has been conducted into their afterlife in early modern Ireland. However, a strikingly high number of these works continued to be read and copied well into the seventeenth century and some, such as the Irish translations of Octavian and William of Palerne, only survive in manuscripts from this later period. This paper takes these translations as a test case to explore the ways in which a cross-period approach to such writing is applicable in Ireland, a country where the renaissance is generally considered to have taken little hold. It considers the extent to which Irish reception of this translated material shifts and evolves in the course of this turbulent period and whether the same factors that contributed to the continued demand for a range of similar texts in England into the seventeenth century are also discernible in the Irish context.
Resumo:
The defense reactions against biological (Histoplasma capsulatum and Escherichia coli) and non-biological materials (China ink and nylon thread) were tested in vivo in third instar larvae of Dermatobia hominis. The cellular defense performed by larval hemocytes was observed under electron microscopy. China ink particles were phagocytosed by granular cells 5 h after injection. E. coli cells were internalized by granular cells as early as 5 min after injection and totally cleared 180 min post-injection, when many hemocytes appeared disintegrated and others in process of recovering. H. capsulatum yeasts provoked, 24 h after being injected, the beginning of nodule formation. Nylon thread was encapsulated 24 h after the introduction into the hemocoel. Our results suggest that granular cells were the phagocytic cells and also the responsible for the triggering of nodule and capsule formation. In the presence of yeasts cells and nylon thread, they released their granules that chemotactically attracted the plasmatocytes that on their turn, flattened to surround and isolate the foreign material.
Resumo:
Bezoar é a impactação de material estranho no interior do trato digestivo, originado a partir da ingestão de diversas substâncias, incluindo cabelos ou pêlos, fibras vegetais e outros. No presente estudo relata-se caso de um volumoso tricobezoar gástrico observado em uma adolescente de 16 anos, com queixa de dor e tumoração palpável na região epigástrica, diagnosticado através da endoscopia digestiva alta. Dada às proporções do bezoar, a paciente foi submetida à gastrotomia anterior com retirada de uma massa sólida de cabelos, com 1200 g, a qual moldava todo o estômago, desde o fundo até o piloro. Uma grande úlcera de pressão também foi detectada em região antral, cujas biópsias revelaram- se negativas para neoplasia. Após a alta, sem intercorrências, a paciente foi encaminhada ao Serviço de Neuropsiquiatria para o tratamento da tricofagia e prevenção da recorrência, objetivo final, ao nosso ver, de todo o tratamento.
Resumo:
A taxonomic revision of the family Compsopogonaceae in Brazil was carried out, resulting in the recognition of a single genus (Compsopogon) with two species (C. coeruleus and C. leptoclados). For both species the following information was provided: a) nomenclatural type; b) type locality; c) description (with illustrations); d) diagnostic features; e) world distribution; f) distribution in Brazil (with map); g) habitat, associated species and seasonality; h) remarks, including discussion of taxonomic and/or nomenclatural problems and comparison with previous reports based on Brazilian and foreign material. Currently accepted diagnostic criteria for genera and species within Compsopogonaceae are critically analysed. The circumscription of Compsopogon and Compsopogonopsis are evaluated and the single genus Compsopogon is recognized in the family.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Although cestodes of the genus Echinococcus have been much studied in the past, there is need for an evaluation of these morphological characters used as the basis for species differentiation. The generous cooperation of other investigators in providing necessary foreign material and the results of nearly five years of field work in Alaska make possible such a study. It is the purpose of the paper to evaluate morphological characters used at the species level to differentiate these cestodes, and to review the status of species currently considered valid.
Resumo:
Abstract Background Endothelial cells play an important role in the delivery of cells to the inflammation site, chemotaxis, cell adhesion and extravasation. Implantation of a foreign material into the human body determines inflammatory and repair reactions, involving different cell types with a plethora of released chemical mediators. The evaluation of the interaction of endothelial cells and implanted materials must take into account other parameters in addition to the analysis of maintenance of cell viability. Methods In the present investigation, we examined the behavior of human umbilical vein endothelial cells (HUVECs) harvested on titanium (Ti), using histological and immunohistochemical methods. The cells, after two passages, were seeded in a standard density on commercially plate-shaped titanium pieces, and maintained for 1, 7 or 14 days. Results After 14 days, we could observe a confluent monolayer of endothelial cells (ECs) on the titanium surface. Upon one-day Ti/cell contact the expression of fibronectin was predominantly cytoplasmatic and stronger than on the control surface. It was observed strong and uniform cell expression along the time of α5β1 integrin on the cells in contact with titanium. Conclusion The attachment of ECs on titanium was found to be related to cellular-derived fibronectin and the binding to its specific receptor, the α5β1 integrin. It was observed that titanium effectively serves as a suitable substrate for endothelial cell attachment, growth and proliferation. However, upon a 7-day contact with Ti, the Weibel-Palade bodies appeared to be not fully processed and exhibited an anomalous morphology, with corresponding alterations of PECAM-1 localization.