594 resultados para discriminating
Resumo:
We consider brightness/contrast-invariant and rotation-discriminating template matching that searches an image to analyze A for a query image Q We propose to use the complex coefficients of the discrete Fourier transform of the radial projections to compute new rotation-invariant local features. These coefficients can be efficiently obtained via FFT. We classify templates in ""stable"" and ""unstable"" ones and argue that any local feature-based template matching may fail to find unstable templates. We extract several stable sub-templates of Q and find them in A by comparing the features. The matchings of the sub-templates are combined using the Hough transform. As the features of A are computed only once, the algorithm can find quickly many different sub-templates in A, and it is Suitable for finding many query images in A, multi-scale searching and partial occlusion-robust template matching. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Inaccurate species identification confounds insect ecological studies. Examining aspects of Trichogramma ecology pertinent to the novel insect resistance management strategy for future transgenic cotton, Gossypium hirsutum L., production in the Ord River Irrigation Area (ORIA) of Western Australia required accurate differentiation between morphologically similar Trichogramma species. Established molecular diagnostic methods for Trichogramma identification use species-specific sequence difference in the internal transcribed spacer (ITS)-2 chromosomal region; yet, difficulties arise discerning polymerase chain reaction (PCR) fragments of similar base pair length by gel electrophoresis. This necessitates the restriction enzyme digestion of PCR-amplified ITS-2 fragments to readily differentiate Trichogramma australicum Girault and Trichogramma pretiosum Riley. To overcome the time and expense associated with a two-step diagnostic procedure, we developed a “one-step” multiplex PCR technique using species-specific primers designed to the ITS-2 region. This approach allowed for a high-throughput analysis of samples as part of ongoing ecological studies examining Trichogramma biological control potential in the ORIA where these two species occur in sympatry.
Resumo:
The effect that the difficulty of the discrimination between task-relevant and task-irrelevant stimuli has on the relationship between skin conductance orienting and secondary task reaction time (RT) was examined. Participants (N = 72) counted the number of longer-than-usual presentations of one shape (task-relevant) and ignored presentations of another shape (task-irrelevant). The difficulty of discriminating between the two shapes varied across three groups (low, medium, and high difficulty). Simultaneous with the primary counting task, participants performed a secondary RT task to acoustic probes presented 50, 150, and 2000 ms following shape onset. Skin conductance orienting was larger, and secondary RT at the 2000 ms probe position was slower during task-relevant shapes than during task-irrelevant shapes in the low-difficulty group. This difference declined as the discrimination difficulty was increased, such that there was no difference in the high-difficulty group. Secondary RT was slower during task-irrelevant shapes than during task-relevant shapes only in the medium-difficulty group-and only at the 150 ms probe position in the first half of the experiment. The close relationship between autonomic orienting and secondary RT at the 2000 ms probe position suggests that orienting reflects the resource allocation that results from the number of matching features between a stimulus input and a mental representation primed as significant.
Resumo:
P>Background Congenital adrenal hyperplasia caused by classic 21-hydroxylase deficiency (21OHD) is an autosomal recessive disorder with a high prevalence of asymptomatic heterozygote carriers (HTZ) in the general population, making case detection desirable by routine methodology. HTZ for classic and nonclassic (NC) forms have basal and ACTH-stimulated values of 17-hydroxyprogesterone (17OHP) that fail to discriminate them from the general population. 21-Deoxycortisol (21DF), an 11-hydroxylated derivative of 17OHP, is an alternative approach to identify 21OHD HTZ. Objective To determine the discriminating value of basal and ACTH-stimulated serum levels of 21DF in comparison with 17OHP in a population of HTZ for 21OHD (n = 60), as well as in NC patients (n = 16) and in genotypically normal control subjects (CS, n = 30), using fourth generation tandem mass spectrometry after HPLC separation (LC-MS/MS). Results Basal 21DF levels were not different between HTZ and CS, but stimulated values were increased in the former and virtually nonresponsive in CS. Only 17 center dot 7% of the ACTH-stimulated 21DF levels overlapped with CS, when compared to 46 center dot 8% for 17OHP. For 100% specificity, the sensitivities achieved for ACTH-stimulated 21DF, 17OHP and the quotient [(21DF + 17OHP)/F] were 82 center dot 3%, 53 center dot 2% and 87%, using cut-offs of 40, 300 ng/dl and 46 (unitless), respectively. Similar to 17OHP, ACTH-stimulated 21DF levels did not overlap between HTZ and NC patients. A positive and highly significant correlation (r = 0 center dot 846; P < 0 center dot 001) was observed between 21DF and 17OHP pairs of values from NC and HTZ. Conclusion This study confirms the superiority of ACTH-stimulated 21DF, when compared to 17OHP, both measured by LC-MS/MS, in identifying carriers for 21OHD. Serum 21DF is a useful tool in genetic counselling to screen carriers among relatives in families with affected subjects, giving support to molecular results.
Resumo:
Discriminating groups were introduced by G.Baumslag, A.Myasnikov and V.Remeslennikov as an outgrowth of their theory of algebraic geometry over groups. However they have taken on a life of their own and have been an object of a considerable amount of study. In this paper we survey the large array results concerning the class of discriminating groups that have been developed over the past decade.
Resumo:
Some forensic and clinical circumstances require knowledge of the frequency of drug use. Care of the patient, administrative, and legal consequences will be different if the subject is a regular or an occasional cannabis smoker. To this end, 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) has been proposed as a criterion to help to distinguish between these two groups of users. However, to date this indicator has not been adequately assessed under experimental conditions. We carried out a controlled administration study of smoked cannabis with a placebo. Cannabinoid levels were determined in whole blood using tandem mass spectrometry. Significantly high differences in THCCOOH concentrations were found between the two groups when measured during the screening visit, prior to the smoking session, and throughout the day of the experiment. Receiver operating characteristic (ROC) curves were determined and two threshold criteria were proposed in order to distinguish between these groups: a free THCCOOH concentration below 3 µg/L suggested an occasional consumption (≤ 1 joint/week) while a concentration higher than 40 µg/L corresponded to a heavy use (≥ 10 joints/month). These thresholds were tested and found to be consistent with previously published experimental data. The decision threshold of 40 µg/L could be a cut-off for possible disqualification for driving while under the influence of cannabis. A further medical assessment and follow-up would be necessary for the reissuing of a driving license once abstinence from cannabis has been demonstrated. A THCCOOH level below 3 µg/L would indicate that no medical assessment is required. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
OBJECTIVES: The aim of this study was to evaluate new electrocardiographic (ECG) criteria for discriminating between incomplete right bundle branch block (RBBB) and the Brugada types 2 and 3 ECG patterns. BACKGROUND: Brugada syndrome can manifest as either type 2 or type 3 pattern. The latter should be distinguished from incomplete RBBB, present in 3% of the population. METHODS: Thirty-eight patients with either type 2 or type 3 Brugada pattern that were referred for an antiarrhythmic drug challenge (AAD) were included. Before AAD, 2 angles were measured from ECG leads V(1) and/or V(2) showing incomplete RBBB: 1) α, the angle between a vertical line and the downslope of the r'-wave, and 2) β, the angle between the upslope of the S-wave and the downslope of the r'-wave. Baseline angle values, alone or combined with QRS duration, were compared between patients with negative and positive results on AAD. Receiver-operating characteristic curves were constructed to identify optimal discriminative cutoff values. RESULTS: The mean β angle was significantly smaller in the 14 patients with negative results on AAD compared to the 24 patients with positive results on AAD (36 ± 20° vs. 62 ± 20°, p < 0.01). Its optimal cutoff value was 58°, which yielded a positive predictive value of 73% and a negative predictive value of 87% for conversion to type 1 pattern on AAD; α was slightly less sensitive and specific compared with β. When the angles were combined with QRS duration, it tended to improve discrimination. CONCLUSIONS: In patients with suspected Brugada syndrome, simple ECG criteria can enable discrimination between incomplete RBBB and types 2 and 3 Brugada patterns.
Resumo:
Background and Aims: Discriminating irritable bowel syndrome (IBS) from inflammatorybowel disease (IBD) can be a clinical challenge as symptoms can overlap. We and othershave recently shown that fecal calprotectin (FC) is more accurate for discriminating IBSfrom IBD compared to C-reactive protein (CRP) and blood leukocytes. Data on the biomarkersused in daily gastroenterological practice are lacking. We therefore aimed to assess whichbiomarkers are used by gastroenterologists in their daily practice for discriminating IBSfrom IBD.Methods: A questionnaire was sent to all board certified gastroenterologists inSwitzerland focusing on demographic informations, number of IBS patients treated in thetime period from May 2009 to April 2010, and the specific biomarkers evaluated fordiscriminating IBS from IBD.Results: Response rate was 57% (153/270). Mean physician'sage was 50±9years, mean duration of gastroenterologic practice 14±8years, 52% of themwere working in private practice and 48% in hospitals. Thirty-nine percent had taken careof more than 100 IBS patients in the last 12 months, 37% had seen 41-100 and 24% hadseen 1-40 IBS patients. Gastroenterologists in private practice more frequently took care ofat least 40 IBS patients in a year compared to hospital-based gastroenterologists (P<0.001).The following biomarkers were determined for discriminating IBS from IBD: CRP 100%,FC 79%, hematogram (red blood cells and leukocytes) 70%, iron status (ferritin, transferrinsaturation) 59%, erythrocyte sedimentation rate 2.7%, protein electrophoresis 0.7%, andalpha-1 antitrypsin clearance 0.7%. There was a trend for using FC more often in privatepractice than in hospital (P = 0.08). Twenty-four percent of gastroenterologists had usedFC in the workup of more than 70% of patients classified as IBS, 22% had used FC in 30-70% of IBS patients, 39% in less than 30%, and 15% had never used FC for the work-upof suspected IBS. Eighty-nine percent of gastroenterologists considered FC to be superiorto CRP for discriminating IBS from IBD, 87% thought that patient's compliance for fecalsampling is high, and 51% judged the fee of USD 60 for a FC test as appropriate.Conclusions:FC is widely used in clinical practice to discriminate IBS from IBD. In accordance with thescientific evidence, the majority of gastroenterologists consider FC to be more accurate thanCRP for discriminating IBS from IBD. Gastroenterologists in private practice take care ofsignificantly more IBS patients than colleagues in hospital.
Resumo:
Le syndrome de Brugada, une affection rythmique du sujet jeune potentiellement fatale, se manifeste sur l'ECG par un bloc de branche droit (BBD) complet, avec sus-décalage majeur du segment ST et inversion des ondes Τ de V1 à V3 appelé pattern de type 1. Cette présentation peut être intermittente. Les manifestations incomplètes du syndrome de Brugada sont appelées patterns de types 2 ou 3, et sont caractérisées par un BBD incomplet et un sus-décalage ST plus ou moins prononcé dans les dérivations V-, et V2 de l'ECG. Cette description, cependant, est aussi celle du BBD incomplet fréquemment rencontré chez les sujets jeunes, de moins de 40 ans, et présent dans 3% de la population. Bo nombre de ces sujets sont donc référés pour une recherche de syndrome de Brugada. Le but de cette thèse est donc d'évaluer de nouveaux critères permettant de discriminer les BBD incomplets, banals, des sujets porteurs d'un syndrome de Brugada de types 2 ou 3. Trente-huit patients avec un pattern de Brugada de types 2 et 3, référés pour un test médicamenteux utilisant un antiarythmique révélant un pattern de type 1 chez les sujets porteurs, ont été inclus dans l'étude. Avant le test médicamenteux, deux angles ont été mesurés sur les dérivations Vi et/ou V2 : a, l'angle entre une ligne verticale et la descente de l'onde r', et β, l'angle entre la montée de l'onde S et la descente de l'onde r'. Les mesure à l'état basai des deux angles, seules ou combinées avec la durée du QRS, on été comparées entre les patients avec une épreuve pharmacologique positive et ceux dont l'épreuve s'est révélée négative (i.e. servant de groupe contrôle car porteur d'un véritable BBD incomplet). Des courbes ROC ont été établies afin de déterminer les valeurs d'angles les plus discriminantes. La moyenne des angles β était significativement plus petite chez les 14 patients avec un test pharmacologique négatif comparé aux 24 patients avec un test positif. La valeur optimale pour l'angle β était de 58°, ce qui donnait une valeur prédictive positive de 73% et une valeur prédictive négative de 97% pour une conversion en pattern de type 1 lors du test pharmacologique. L'angle α était un peu moins sensible et spécifique que β. Quand les angles étaient combinés à la durée du QRS, on observait une discrète amélioration de la discrimination entre les deux populations. Notre travail permet donc, chez des patients suspects d'un syndrome de Brugada, de discriminer entre un BBD incomplet et les patterns de Brugada types 2 et 3 en utilisant un critère simple basé sur l'ECG de surface potentiellement applicable au lit du patient
Resumo:
Background a nd A ims: D iscriminating irritable bowelsyndrome (IBS) from inflammatory bowel disease (IBD) can bea clinical c hallenge as s ymptoms c an overlap. We a nd othershave recently shown that fecal c alprotectin ( FC) is moreaccurate for d iscriminating IBS f rom IBD compared to C -reactive p rotein ( CRP) and b lood leukocytes. We a imed toassess which b iomarkers are used by g astroenterologists intheir daily practice for discriminating IBS from IBD.Methods: A q uestionnaire was sent to all board certifiedgastroenterologists in Switzerland in July 2010.Results: Response rate was 57% (153/270). Mean physician'sage was 50±9years, mean duration o f gastroenterologicpractice 1 4±8years, 52% of them were working in p rivatepractice a nd 48% in h ospitals. T he following biomarkers weredetermined for discriminating IBS from IBD: CRP 100%, FC79%, hematogram (red blood cells and leukocytes) 70%, ironstatus ( ferritin, t ransferrin s aturation) 59%, e rythrocytesedimentation rate 2.7%, protein electrophoresis 0.7%, andalpha-1 antitrypsin clearance 0.7%. There was a trend for usingFC more often in p rivate practice t han in h ospital ( P = 0.08).Eighty-nine percent of gastroenterologists considered FC to besuperior to CRP for discriminating IBS from IBD, 8 7% thoughtthat patient's compliance for fecal sampling is high, and 51%judged the fee of USD 60 for a FC test as appropriate.Conclusions: F C is widely used in c linical practice t odiscriminate IBS from IBD. In accordance with the scientificevidence, the majority of gastroenterologists consider FC to bemore accurate than CRP for discriminating IBS from IBD.
Resumo:
In this paper we propose an innovative methodology for automated profiling of illicit tablets bytheir surface granularity; a feature previously unexamined for this purpose. We make use of the tinyinconsistencies at the tablet surface, referred to as speckles, to generate a quantitative granularity profileof tablets. Euclidian distance is used as a measurement of (dis)similarity between granularity profiles.The frequency of observed distances is then modelled by kernel density estimation in order to generalizethe observations and to calculate likelihood ratios (LRs). The resulting LRs are used to evaluate thepotential of granularity profiles to differentiate between same-batch and different-batches tablets.Furthermore, we use the LRs as a similarity metric to refine database queries. We are able to derivereliable LRs within a scope that represent the true evidential value of the granularity feature. Thesemetrics are used to refine candidate hit-lists form a database containing physical features of illicittablets. We observe improved or identical ranking of candidate tablets in 87.5% of cases when granularityis considered.
Resumo:
In this study, the evaluation of the accuracy and performance of a light detection and ranging (LIDAR) sensor for vegetation using distance and reflection measurements aiming to detect and discriminate maize plants and weeds from soil surface was done. The study continues a previous work carried out in a maize field in Spain with a LIDAR sensor using exclusively one index, the height profile. The current system uses a combination of the two mentioned indexes. The experiment was carried out in a maize field at growth stage 12–14, at 16 different locations selected to represent the widest possible density of three weeds: Echinochloa crus-galli (L.) P.Beauv., Lamium purpureum L., Galium aparine L.and Veronica persica Poir.. A terrestrial LIDAR sensor was mounted on a tripod pointing to the inter-row area, with its horizontal axis and the field of view pointing vertically downwards to the ground, scanning a vertical plane with the potential presence of vegetation. Immediately after the LIDAR data acquisition (distances and reflection measurements), actual heights of plants were estimated using an appropriate methodology. For that purpose, digital images were taken of each sampled area. Data showed a high correlation between LIDAR measured height and actual plant heights (R2 = 0.75). Binary logistic regression between weed presence/absence and the sensor readings (LIDAR height and reflection values) was used to validate the accuracy of the sensor. This permitted the discrimination of vegetation from the ground with an accuracy of up to 95%. In addition, a Canonical Discrimination Analysis (CDA) was able to discriminate mostly between soil and vegetation and, to a far lesser extent, between crop and weeds. The studied methodology arises as a good system for weed detection, which in combination with other principles, such as vision-based technologies, could improve the efficiency and accuracy of herbicide spraying.
Resumo:
Laboratory test was carried out on larvae and adults of the cattle tick, Rhipicephalus (Boophilus) microplus, to determine fipronil toxicity. Adult immersion test (AIT, N = 26), larval immersion test (LIT, N = 71) and larval packet test (LPT, N = 41) were standardized using susceptible strain (Mozo). Dose-response curves were compared with a fipronil resistant strain. Four variables were analyzed from AIT results: mortality, weight of eggs on day 7 and on day 14, index of fertility, and index of fecundity. For larval test, dose mortality curves were analyzed. In spite of the high LC(50) variability, all variables determined for AIT were appropriate to discriminate both strains. AIT and LIT had more sensitivity than LPT, with larger resistance factors. It was used two times LC(99.9) as discriminating doses (DCs) following FAO suggestion. For mortality by AIT, LIT and LPT the DCs were estimated: 4.98 ppm, 7.64 ppm and 2365.8 ppm, respectively, for Mozo strain. DCs mortality values estimated for resistant strain by AIT, LIT and LPT were: 6.96 x 10(5) ppm, 343.26 ppm and 5.7 x 10(3) ppm, respectively and their respective resistant factors were: 202.4, 5.36 and 1.52. Protocols for AIT, LIT and LPT have been presented in this paper. (C) 2009 Elsevier B.V. All rights reserved.