914 resultados para cardiac rhythm


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate the electrocardiographic alterations in the cardiac rhythm in dogs treated with levamisole hydrochloride over a period of 24 hours. Thirty-six mixed-breed dogs, both male and female, all clinically healthy, were used in the experiment. The dogs were divided into 6 groups with 6 dogs in each group, according to dosage and route of administration. The Holter test was initiated immediately after the treatment, and was maintained for 24 hours. In the group treated with 10 mg/kg by way of subcutaneous injection, one of them showed ventricular premature complexes, sometimes isolated and other times in pairs, and ventricular tachycardia, concentrated mainly in the first hour after administration of the drug. In the group of 6 animals treated subcutaneously with 25mg/kg, four showed isolated ventricular premature complexes, ventricular bigeminy and trigeminy, mainly during the first 2 hours after administration of the drug. All the animals in the other groups showed sinus arrhythmia followed by sinus arrest. The disturbances in the cardiac rhythm observed in clinically healthy animals treated with levamisole hydrochloride, indicate that it is preferable to avoid subcutaneous administration of levamisole hydrochloride and that the oral administration of the drug should be done with caution. © 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amlodipine is a dihydropyridine calcium channel antagonist extensively used for the treatment of arterial hypertension, with predominant effect on the peripheral vascular territory. In most cases of severe intoxication, important hypotension and reflex tachycardia are usually observed. We report a case of young man with severe amlodipine intoxication that developed important bradyarrhythmias, such as low atrial rhythm, prolonged PR interval, atrioventricular block, and left bundle branch block. These rhythm disturbances suggest that, during acute intoxication, dihydropyridine loses its selective action on the vascular territory and can depress automatism and conduction of cardiac electrical stimulus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the effects of an anatoxin-a(s)-containing extract on a cockroach semi-isolated heart preparation and the results supporting the extract s biological activity on acetylcholinesterase (purified from ell). The presence of the toxin in cyanobacterial strains Anabaena spiroides (ITEP-024, ITEP-025 and ITEP-026) isolated from the Tapacurá reservoir in Pernambuco, Brazil, was confirmed by means of liquid chromatography coupled to an ion-trap mass spectrometer. The anticholinesterase activity was assessed biochemically by the Ellman test and was confirmed by measuring the cockroach s heart rate. The concentration of the extract containing the tested anatoxin-a(s) (antx-a(s)) (10, 16 and 100 μg.μL-1) inhibited the eel acetylcholinesterase (AChE) by more than 90%. The cockroach cardiac frequency increased by a maximum of about 20% within 29 min after the addition of 2.5x10³ μg of extract containing antxa (s).g-1 bw (n=9, p<0.05). Our results strongly indicate that antx-a(s) is capable of exerting biological effects on cockroach, indicating that more research might be conducted to determine its role in the environment, especially on insects.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: The mechanisms associated with the cardiovascular consequences of obstructive sleep apnea include abrupt changes in autonomic tone, which can trigger cardiac arrhythmias. The authors hypothesized that nocturnal cardiac arrhythmia occurs more frequently in patients with obstructive sleep apnea. Objective: To analyze the relationship between obstructive sleep apnea and abnormal heart rhythm during sleep in a population sample. Methods: Cross-sectional study with 1,101 volunteers, who form a representative sample of the city of São Paulo. The overnight polysomnography was performed using an EMBLA® S7000 digital system during the regular sleep schedule of the individual. The electrocardiogram channel was extracted, duplicated, and then analyzed using a Holter (Cardio Smart®) system. Results: A total of 767 participants (461 men) with a mean age of 42.00 ± 0.53 years, were included in the analysis. At least one type of nocturnal cardiac rhythm disturbance (atrial/ventricular arrhythmia or beat) was observed in 62.7% of the sample. The occurrence of nocturnal cardiac arrhythmias was more frequent with increased disease severity. Rhythm disturbance was observed in 53.3% of the sample without breathing sleep disorders, whereas 92.3% of patients with severe obstructive sleep apnea showed cardiac arrhythmia. Isolated atrial and ventricular ectopy was more frequent in patients with moderate/severe obstructive sleep apnea when compared to controls (p < 0.001). After controlling for potential confounding factors, age, sex and apnea-hypopnea index were associated with nocturnal cardiac arrhythmia. Conclusion: Nocturnal cardiac arrhythmia occurs more frequently in patients with obstructive sleep apnea and the prevalence increases with disease severity. Age, sex, and the Apnea-hypopnea index were predictors of arrhythmia in this sample.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Therapeutic hypothermia and pharmacological sedation may influence outcome prediction after cardiac arrest. The use of a multimodal approach, including clinical examination, electroencephalography, somatosensory-evoked potentials, and serum neuron-specific enolase, is recommended; however, no study examined the comparative performance of these predictors or addressed their optimal combination. DESIGN: Prospective cohort study. SETTING: Adult ICU of an academic hospital. PATIENTS: One hundred thirty-four consecutive adults treated with therapeutic hypothermia after cardiac arrest. MEASUREMENTS AND MAIN RESULTS: Variables related to the cardiac arrest (cardiac rhythm, time to return of spontaneous circulation), clinical examination (brainstem reflexes and myoclonus), electroencephalography reactivity during therapeutic hypothermia, somatosensory-evoked potentials, and serum neuron-specific enolase. Models to predict clinical outcome at 3 months (assessed using the Cerebral Performance Categories: 5 = death; 3-5 = poor recovery) were evaluated using ordinal logistic regressions and receiving operator characteristic curves. Seventy-two patients (54%) had a poor outcome (of whom, 62 died), and 62 had a good outcome. Multivariable ordinal logistic regression identified absence of electroencephalography reactivity (p < 0.001), incomplete recovery of brainstem reflexes in normothermia (p = 0.013), and neuron-specific enolase higher than 33 μg/L (p = 0.029), but not somatosensory-evoked potentials, as independent predictors of poor outcome. The combination of clinical examination, electroencephalography reactivity, and neuron-specific enolase yielded the best predictive performance (receiving operator characteristic areas: 0.89 for mortality and 0.88 for poor outcome), with 100% positive predictive value. Addition of somatosensory-evoked potentials to this model did not improve prognostic accuracy. CONCLUSIONS: Combination of clinical examination, electroencephalography reactivity, and serum neuron-specific enolase offers the best outcome predictive performance for prognostication of early postanoxic coma, whereas somatosensory-evoked potentials do not add any complementary information. Although prognostication of poor outcome seems excellent, future studies are needed to further improve prediction of good prognosis, which still remains inaccurate.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: The SCN5A gene encodes for the α-subunit of the cardiac sodium channel NaV1.5, which is responsible for the rapid upstroke of the cardiac action potential. Mutations in this gene may lead to multiple life-threatening disorders of cardiac rhythm or are linked to structural cardiac defects. Here, we characterized a large family with a mutation in SCN5A presenting with an atrioventricular conduction disease and absence of Brugada syndrome. METHOD AND RESULTS: In a large family with a high incidence of sudden cardiac deaths, a heterozygous SCN5A mutation (p.1493delK) with an autosomal dominant inheritance has been identified. Mutation carriers were devoid of any cardiac structural changes. Typical ECG findings were an increased P-wave duration, an AV-block I° and a prolonged QRS duration with an intraventricular conduction delay and no signs for Brugada syndrome. HEK293 cells transfected with 1493delK showed strongly (5-fold) reduced Na(+) currents with altered inactivation kinetics compared to wild-type channels. Immunocytochemical staining demonstrated strongly decreased expression of SCN5A 1493delK in the sarcolemma consistent with an intracellular trafficking defect and thereby a loss-of-function. In addition, SCN5A 1493delK channels that reached cell membrane showed gain-of-function aspects (slowing of the fast inactivation, reduction in the relative fraction of channels that fast inactivate, hastening of the recovery from inactivation). CONCLUSION: In a large family, congregation of a heterozygous SCN5A gene mutation (p.1493delK) predisposes for conduction slowing without evidence for Brugada syndrome due to a predominantly trafficking defect that reduces Na(+) current and depolarization force.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Rhythm analysis of the fetal heart is hampered by the inability to routinely obtain electrocardiographic recordings of the fetus. Doppler studies of fetal cardiac tissue movements, assessing cardiac movements both qualitatively and quantitatively, have recently been described. We used a conventional high-resolution ultrasound system to obtain rhythm data from pulsed-wave tissue Doppler signals of the fetal heart in normal cardiac rhythm and in a variety of fetal cardiac arrhythmias.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To compare the effects on heart rate (HR), on left ventricular (LV) or arterial pressures, and the general safety of a non-ionic low-osmolar contrast medium (CM) and a non-ionic iso-osmolar CM in patients undergoing cardiac angiography (CA) or peripheral intra-arterial digital subtraction angiography (IA-DSA). MATERIALS AND METHODS: Two double-blind, randomized studies were conducted in 216 patients who underwent CA (n=120) or peripheral IA-DSA (n=96). Patients referred for CA received a low-osmolar monomeric CM (iomeprol-350, n=60) or an iso-osmolar dimeric CM (iodixanol-320; n=60). HR and LV peak systolic and end-diastolic pressures were determined before and after the first injection during left and right coronary arteriography and left ventriculography. Monitoring for all types of adverse event (AE) was performed for 24 h following the procedure. t-tests were performed to compare CM for effects on HR. Patients referred for IA-DSA received iomeprol-300 (n=49) or iodixanol-320 (n=47). HR and arterial blood pressure (BP) were evaluated before and after the first 4 injections. Monitoring for AE was performed for 4 h following the procedure. Repeated-measures ANOVA was used to compare mean HR changes across the first 4 injections, whereas changes after the first injection were compared using t-tests. RESULTS: No significant differences were noted between iomeprol and iodixanol in terms of mean changes in HR during left coronary arteriography (p=0.8), right coronary arteriography (p=0.9), and left ventriculography (p=0.8). In patients undergoing IA-DSA, no differences between CM were noted for effects on mean HR after the first injection (p=0.6) or across the first 4 injections (p=0.2). No significant differences (p>0.05) were noted in terms of effects on arterial BP in either study or on LV pressures in patients undergoing CA. Non-serious AE considered possibly CM-related (primarily headache and events affecting the cardiovascular and digestive systems) were reported more frequently by patients undergoing CA and more frequently after iodixanol (14/60 [23.3%] and 2/47 [4.3%]; CA and IA-DSA, respectively) than iomeprol (10/60 [16.7%] and 1/49 [2%], respectively). CONCLUSIONS: Iomeprol and iodixanol are safe and have equally negligible effects on HR and LV pressures or arterial BP during and after selective intra-cardiac injection and peripheral IA-DSA. CLINICAL APPLICATION: Iomeprol and iodixanol are safe and equally well tolerated with regard to cardiac rhythm and clinical preference should be based on diagnostic image quality alone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avaliou-se o eletrocardiograma de 100 equinos sadios praticantes de hipismo clássico modalidade salto, com idades entre 4 e 19 anos, sendo 61 machos e 39 fêmeas, com média de 516,3 kg. Observou-se frequência cardíaca média de 40,20 ±13,33 bpm, sendo o ritmo cardíaco mais freqüente o sinusal (56%). As alterações de ritmo cardíaco estiveram presentes em 38% dos animais estudados, sendo a mais presente o marcapasso migratório (22%), seguido de bloqueio atrioventricular de 2º grau (4%), bloqueio atrioventricular de 1º grau (3%), contração ventricular prematura (2%), contração atrial prematura (1%). Não se observou correlação entre as variáveis estudadas (freqüência cardíaca, ritmo e arritmias) e a capacidade atlética, a idade e o sexo. O escore cardíaco após analise estatística não diferiu entre os grupos quanto ao desempenho atlético, a faixa etária e o sexo. O escore cardíaco, nesta amostra, não se mostrou um parâmetro confiável para se predizer o futuro atlético ou o nível de treinamento do eqüino.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta dissertação apresenta o trabalho realizado no âmbito da unidade curricular de Tese/Dissertação (TEDI), do 2º ano, do Mestrado em Engenharia Eletrotécnica e de Computadores no ramo de Automação e Sistemas. O principal objetivo desta dissertação consiste no desenvolvimento de um sistema que permita efetuar a deteção de um determinado número de anomalias num sinal eletrocardiográfico. O coração é um dos órgãos mais importantes do corpo humano. É ele que recebe e bombeia o sangue pelo organismo. Isto é, recebe sangue pobre em oxigénio, encaminha-o para os pulmões onde será enriquecido em oxigénio. O sangue enriquecido em oxigénio é então encaminhado novamente para o coração que será enviado para todas as partes do corpo humano. O eletrocardiograma desempenha um papel fundamental de modo a diagnosticar eventuais anomalias no correto funcionamento do coração. Estas anomalias podem dever-se a diversos fatores como tabaco, colesterol, pressão sanguínea alta ou diabetes entre outros. As anomalias associadas ao ritmo cardíaco são denominadas de arritmias. As arritmias são fundamentalmente originadas pela alteração da frequência ou do ritmo cardíaco. Utilizando a lógica difusa, pretendeu-se desenvolver um sistema que fizesse a identificação de um determinado número de tipos de batimentos entre os quais: o bloqueio do ramo esquerdo (LBBB), bloqueio do ramo direito (RBBB), contração prematura ventricular (VPC) e contração prematura auricular (APC). Todos os desenvolvimentos efetuados, a nível de programação, são neste documento relatados de forma a constituírem um possível guia para a utilização deste tipo de sistemas. Mais ainda, descrevem-se nele toda a pesquisa efetuada e as alternativas de desenvolvimento selecionadas. O Sistema de Deteção de Arritmias (SDA) desenvolvido mostrou-se eficaz desde que o utilizador consiga identificar corretamente os parâmetros que lhe são pedidos. A interface gráfica desenvolvida permitiu também uma maior facilidade durante a análise do sinal eletrocardiográfico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The ability of the developing myocardium to tolerate oxidative stress during early gestation is an important issue with regard to possible detrimental consequences for the fetus. In the embryonic heart, antioxidant defences are low, whereas glycolytic flux is high. The pro- and antioxidant mechanisms and their dependency on glucose metabolism remain to be explored. Isolated hearts of 4-day-old chick embryos were exposed to normoxia (30 min), anoxia (30 min), and hyperoxic reoxygenation (60 min). The time course of ROS production in the whole heart and in the atria, ventricle, and outflow tract was established using lucigenin-enhanced chemiluminescence. Cardiac rhythm, conduction, and arrhythmias were determined. The activity of superoxide dismutase, catalase, gutathione reductase, and glutathione peroxidase as well as the content of reduced and oxidized glutathione were measured. The relative contribution of the ROS-generating systems was assessed by inhibition of mitochondrial complexes I and III (rotenone and myxothiazol), NADPH oxidases (diphenylene iodonium and apocynine), and nitric oxide synthases (N-monomethyl-l-arginine and N-iminoethyl-l-ornithine). The effects of glycolysis inhibition (iodoacetate), glucose deprivation, glycogen depletion, and lactate accumulation were also investigated. In untreated hearts, ROS production peaked at 10.8 ± 3.3, 9 ± 0.8, and 4.8 ± 0.4 min (means ± SD; n = 4) of reoxygenation in the atria, ventricle, and outflow tract, respectively, and was associated with arrhythmias. Functional recovery was complete after 30-40 min. At reoxygenation, 1) the respiratory chain and NADPH oxidases were the main sources of ROS in the atria and outflow tract, respectively; 2) glucose deprivation decreased, whereas glycogen depletion increased, oxidative stress; 3) lactate worsened oxidant stress via NADPH oxidase activation; 4) glycolysis blockade enhanced ROS production; 5) no nitrosative stress was detectable; and 6) the glutathione redox cycle appeared to be a major antioxidant system. Thus, the glycolytic pathway plays a predominant role in reoxygenation-induced oxidative stress during early cardiogenesis. The relative contribution of mitochondria and extramitochondrial systems to ROS generation varies from one region to another and throughout reoxygenation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Prognosis of status epilepticus (SE) depends on its cause, but there is uncertainty as to whether SE represents an independent outcome predictor for a given etiology. Cerebral anoxia is a relatively homogenous severe encephalopathy. Postanoxic SE is associated to a nearly 100% mortality in this setting; however, it is still unclear whether this is a severity marker of the underlying encephalopathy, or an independent factor influencing outcome. The goal of this study was to assess if postanoxic SE is independently associated with mortality after cerebral anoxia. METHODS: This was a retrospective observation of consecutive comatose survivors of cardiac arrest, including subjects treated with hypothermia. On the subgroup with EEG recordings in the first hospitalization days, univariate and multivariate analyses were applied to potential determinants of in-hospital mortality, and included the following variables: age, gender, type and length of cardiac arrest, occurrence of circulatory shock, presence of therapeutic hypothermia, and electrographic SE. RESULTS: Out of 166 postanoxic patients, 107 (64%) had an EEG (median latency from admission, 2 days); in this group, therapeutic hypothermia was administered in 59%. Death occurred in 71 (67%) patients. Postanoxic SE was associated with mortality regardless of type of acute cardiac rhythm and administration of hypothermic treatment. CONCLUSION: In this hospital-based cohort, postanoxic status epilepticus (SE) seems to be independently related to death in cardiac arrest survivors, suggesting that SE might determine a bad prognosis for a given etiology. Confirmation of these results in a prospective assessment is needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En els darrers anys, els sistemes de telemetria per a aplicacions mèdiques han crescut significativament en el diagnòstic i en la monitorització de, per exemple, la glucosa, la pressió de la sang, la temperatura, el ritme cardíac... Els dispositius implantats amplien les aplicacions en medicina i incorpora una millora de qualitat de vida per a l’usuari. Per aquest motiu, en aquest projecte s’estudien dues de les antenes més comuns, com son l’antena dipol i el patch, aquesta última és especialment utilitzada en aplicacions implantades. En l’anàlisi d’aquestes antenes s’han parametritzat característiques relacionades amb l’entorn de l’aplicació, així com també de la pròpia antena, explicant el comportament que, a diferencia amb l’espai lliure, les antenes presenten a canvis d’aquests paràmetres. Al mateix temps, s’ha implementat una configuració per a la mesura d’antenes implantades basat en el model del cos humà d’una capa. Comparant amb els resultats de les simulacions realitzades mitjançant el software FEKO, s’ha obtingut gran correspondència en la mesura empírica d’adaptació i de guany de les antenes microstrip. Gràcies a l’anàlisi paramètric, aquest projecte també presenta diversos dissenys de les antenes optimitzant el guany realitzable amb l’objectiu d’aconseguir la millor comunicació possible amb el dispositiu extern o estació base.