970 resultados para cancer detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

SKAN: Skin Scanner - System for Skin Cancer Detection Using Adaptive Techniques - combines computer engineering concepts with areas like dermatology and oncology. Its objective is to discern images of skin cancer, specifically melanoma, from others that show only common spots or other types of skin diseases, using image recognition. This work makes use of the ABCDE visual rule, which is often used by dermatologists for melanoma identification, to define which characteristics are analyzed by the software. It then applies various algorithms and techniques, including an ellipse-fitting algorithm, to extract and measure these characteristics and decide whether the spot is a melanoma or not. The achieved results are presented with special focus on the adaptive decision-making and its effect on the diagnosis. Finally, other applications of the software and its algorithms are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigates the relationship between the number of screening mammograms read by radiologists and the screening breast cancer detection rate. Cancer detection rates for incident screens (all women aged >= 40 years) were compared by increasing categories of reader volume using Poisson regression. Data from New South Wales (NSW) for a 2 year period (2000-2001) were obtained from the BreastScreen NSW programme. Cancer detection rates increased with the number of mammograms read in the programme, reaching a plateau of approximately 40 per 10,000 after 1375 mammograms per year. No significant differences in cancer detection were evident above 875 mammograms (compared to below 875 mammograms) per year (RR = 0.79, 95% CI 0.63-0.99). (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since circulating leukocytes, mainly B and T cells, continuously maintain vigilant and comprehensive immune surveillance, these cells could be used as reporters for signs of infection or other pathologies, including cancer. Activated lymphocyte clones trigger a sensitive transcriptional response, which could be identified by gene expression profiling. To assess this hypothesis, we conducted microarray analysis of the gene expression profile of lymphocytes isolated from immunocompetent BALB/c mice subcutaneously injected with different numbers of tumorigenic B61 fibrosarcoma cells. Flow cytometry demonstrated that the number of circulating T (CD3(+)CD4(+) or CD3(+)CD8(+)) or B (CD19(+)) cells did not change. However, the lymphocytes isolated from tumor cell-injected animals expressed a unique transcriptional profile that was identifiable before the development of a palpable tumor mass. This finding demonstrates that the transcriptional response appears before alterations in the main lymphocyte subsets and that the gene expression profile of peripheral lymphocytes can serve as a sensitive and accurate method for the early detection of cancer. Exp Biol Med 234:802-812, 2009

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

About 90% of breast cancers do not cause or are capable of producing death if detected at an early stage and treated properly. Indeed, it is still not known a specific cause for the illness. It may be not only a beginning, but also a set of associations that will determine the onset of the disease. Undeniably, there are some factors that seem to be associated with the boosted risk of the malady. Pondering the present study, different breast cancer risk assessment models where considered. It is our intention to develop a hybrid decision support system under a formal framework based on Logic Programming for knowledge representation and reasoning, complemented with an approach to computing centered on Artificial Neural Networks, to evaluate the risk of developing breast cancer and the respective Degree-of-Confidence that one has on such a happening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cancer is a major burden in today's society and one of the leading causes of death in industrialised countries. Various avenues for the detection of cancer exist, most of which rely on standard methods, such as histology, ELISA, and PCR. Here we put the focus on nanomechanical biosensors derived from atomic force microscopy cantilevers. The versatility of this novel technology has been demonstrated in different applications and in some ways surpasses current technologies, such as microarray, quartz crystal microbalance and surface plasmon resonance. The technology enables label free biomarker detection without the necessity of target amplification in a total cellular background, such as BRAF mutation analysis in malignant melanoma. A unique application of the cantilever array format is the analysis of conformational dynamics of membrane proteins associated to surface stress changes. Another development is characterisation of exhaled breath which allows assessment of a patient's condition in a non-invasive manner.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Autofluorescence bronchoscopy (AFB) is a highly sensitive tool for the detection of early bronchial cancers. However, its specificity remains limited due to primarily false positive results induced by hyperplasia, metaplasia and inflammation. We have investigated the potential of blue-violet backscattered light to eliminate false positive results during AFB in a clinical pilot study. METHODS: The diagnostic autofluorescence endoscopy (DAFE) system was equipped with a variable band pass filter in the imaging detection path. The backscattering properties of normal and abnormal bronchial mucosae were assessed by computing the contrast between the two tissue types for blue-violet wavelengths ranging between 410 and 490 nm in 12 patients undergoing routine DAFE examination. In a second study including 6 patients we used a variable long pass (LP) filter to determine the spectral design of the emission filter dedicated to the detection of this blue-violet light with the DAFE system. RESULTS: (Pre-)neoplastic mucosa showed a clear wavelength dependence of the backscattering properties of blue-violet light while the reflectivity of normal, metaplastic and hyperplastic autofluorescence positive mucosa was wavelength independent. CONCLUSIONS: Our results showed that the detection of blue-violet light has the potential to reduce the number of false positive results in AFB. In addition we determined the spectral design of the emission filter dedicated to the detection of this blue-violet light with the DAFE system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comment on: Hassan C, Di Giulio E, Pickhardt PJ, Zullo A, Laghi A, Kim DH, Iafrate F, Morini S. Cost effectiveness of colonoscopy, based on the appropriateness of an indication. Clin Gastroenterol Hepatol. 2008 Nov;6(11):1231-6.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In this study, we further investigated the association of two biomarkers, CCL18 and A1AT, with bladder cancer (BCa) and evaluated the influence of potentially confounding factors in an experimental model. METHODS: In a cohort of 308 subjects (102 with BCa), urinary concentrations of CCL18 and A1AT were assessed by enzyme-linked immunosorbent assay (ELISA). In an experimental model, benign or cancerous cells, in addition to blood, were added to urines from healthy controls and analyzed by ELISA. Lastly, immunohistochemical staining for CCL18 and A1AT in human bladder tumors was performed. RESULTS: Median urinary protein concentrations of CCL18 (52.84 pg/ml vs. 11.13 pg/ml, p < 0.0001) and A1AT (606.4 ng/ml vs. 120.0 ng/ml, p < 0.0001) were significantly elevated in BCa subjects compared to controls. Furthermore, the addition of whole blood to pooled normal urine resulted in a significant increase in both CCL18 and A1AT. IHC staining of bladder tumors revealed CCL18 immunoreactivity in inflammatory cells only, and there was no significant increase in these immunoreactive cells within benign and cancerous tissue and no association with BCa grade nor stage was noted. A1AT immunoreactivity was observed in the cytoplasm of epithelia cells and intensity of immunostaining increased with tumor grade, but not tumor stage. CONCLUSIONS: Further development of A1AT as a diagnostic biomarker for BCa is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In Finland, breast cancer (BC) is the most common cancer among women, and prostate cancer (PC) that among men. At the metastatic stage both cancers remain essentially incurable. The goals of therapy include palliation of symptoms, improvement or maintenance of quality of life (QoL), delay of disease progression, and prolongation of survival. Balancing between efficacy and toxicity is the major challenge. With increasing costs of new treatments, appropriate use of resources is paramount. When new treatment regimes are introduced into clinical practice a comprehensive assessment of clinical benefit, adverse effects and cost is necessary. Both BC and PC show a predilection to metastasize to bone. Bone metastases cause significant morbidity impairing the patients´ QoL. Diagnosis of bone metastases relies mainly on radiological methods, which however lack optimal sensitivity and specificity. New tools are needed for detection and follow-up of bone metastases. Aims: Anthracyclines and taxanes are effective chemotherapeutic agents in the treatment of metastatic breast cancer (MBC) with different mechanisms of action. Therefore, evaluation of the combination of anthracyclines with taxanes was a justifiable approach in the treatment of MBC patients. We assessed the efficacy, toxicity, cost of treatment and QoL of BC patients treated with first-line chemotherapy for metastatic disease with the combination epirubicin and docetaxel. We also evaluated the diagnostic potential of tartrate-resistant acid phosphatase 5b (TRACP 5b) and carboxyterminal telopeptides of type I collagen (ICTP) in the diagnosis of bone metastases in BC and TRACP 5b in PC patients. Results: The combination of epirubicin and docetaxel was effective in this phase II study, but required individual dose adjustment to avoid neutropenic infections, and the use of growth factors to maintain a feasible dose level. The response rate was 54 % (95 % CI 37-71) and the median overall survival (OS) was 26 months. Of the patients, 87 % were treated for infections. The treatment of adverse events required additional use of health resources mainly due to neutropenic infections, thereby raising direct treatment costs by 20 %. Despite adverse events, the global QoL was not significantly compromised during the treatment. Clinically evident acute cardiac toxicity was not observed. The combination of serum TRACP 5b and ICTP was at least equally sensitive and specific in detection of of bone metastases as commonly used total alkaline phosphatise (tALP) in BC patients. In contrast, TRACP 5b was less specific and sensitive than tALP as a marker of skeletal changes in PC patients. Conclusions: Treatment with epirubicin and docetaxel showed high efficacy in first-line chemotherapy of MBC. The relatively high incidence of neutropenic infections requiring hospitalization increased the treatment costs. Despite adverse events, the global QoL of the patients was not significantly compromised. The combination of TRACP 5b and ICTP showed similar activity as tALP in detecting bone metastases in MBC. In contrast, TRACP 5b was less specific and sensitive than tALP as a marker of skeletal changes in PC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Few studies have addressed racial differences in prostate cancer (PCa) detection between Western and Arabian countries, although PCa has a significantly lower prevalence in Arabic populations compared to Western populations. Therefore, an explanation of this difference is lacking. Serum prostate-specific antigen (PSA) is a valuable marker used to select patients who should undergo prostate biopsies, although the manner in which it is used may require adjustments based on the ethnic population in question. We investigated racial differences in the PCa detection rate between Canadian and Saudi populations. A retrospective analysis was performed of data collected prospectively over 5 consecutive years in urology clinics at the McGill University Health Center (MUHC) and King Saud University Hospital (KSUH). Men who had high (>4'ng/mL) or rising PSA levels and a negative digital rectal examination were eligible. A total of 1403 Canadian and 414 Saudi patients were evaluated for the study; 717 and 158 men, median age 64 and 68 years, were included in the MUHC and KSUH cohorts, respectively, P<0.0001). Median serum PSA, prostate volume, and PSA density values were 6.1'ng/mL, 47.3 g, and 0.12'ng·mL−1·g−1, respectively, for MUHC patients and 5.2'ng/mL, 64.5'g, and 0.08'ng·mL−1·g−1, respectively, for KSUH patients (P<0.0001, t-test followed by one-way ANOVA). In addition, the KSUH group had a significantly lower PCa detection rate among patients younger than 60 years of age and with PSA values <10'ng/mL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Active microwave imaging is explored as an imaging modality for early detection of breast cancer. When exposed to microwaves, breast tumor exhibits electrical properties that are significantly different from that of healthy breast tissues. The two approaches of active microwave imaging — confocal microwave technique with measured reflected signals and microwave tomographic imaging with measured scattered signals are addressed here. Normal and malignant breast tissue samples of same person are subjected to study within 30 minutes of mastectomy. Corn syrup is used as coupling medium, as its dielectric parameters show good match with that of the normal breast tissue samples. As bandwidth of the transmitter is an important aspect in the time domain confocal microwave imaging approach, wideband bowtie antenna having 2:1 VSWR bandwidth of 46% is designed for the transmission and reception of microwave signals. Same antenna is used for microwave tomographic imaging too at the frequency of 3000 MHz. Experimentally obtained time domain results are substantiated by finite difference time domain (FDTD) analysis. 2-D tomographic images are reconstructed with the collected scattered data using distorted Born iterative method. Variations of dielectric permittivity in breast samples are distinguishable from the obtained permittivity profiles.