996 resultados para Uterine vascular perfusion
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJECTIVE: The objective of our study was to establish optimal perfusion conditions for high-resolution postmortem angiography that would permit dynamic visualization of the arterial and venous systems. MATERIALS AND METHODS: Cadavers of two dogs and one cat were perfused with diesel oil through a peristaltic pump. The lipophilic contrast agent Lipiodol Ultra Fluide was then injected, and angiography was performed. The efficiency of perfusion was evaluated in the chick chorioallantoic membrane. RESULTS: Vessels could be seen up to the level of the smaller supplying and draining vessels. Hence, both the arterial and the venous sides of the vascular system could be distinguished. The chorioallantoic membrane assay revealed that diesel oil enters microvessels up to 50 microm in diameter and that it does not penetrate the capillary network. CONCLUSION: After establishing a postmortem circulation by diesel oil perfusion, angiography can be performed by injection of Lipiodol Ultra Fluide. The resolution of the images obtained up to 3 days after death is comparable to that achieved in clinical angiography.
Resumo:
Background: Ultrasound Doppler is a new technology that has recently been used in large animal reproduction. As the conventional ultrasound (B-mode) it is a noninvasive technique, but with the advantage of allows the assessment of the hemodynamic of reproductive tract in real time. The observation of important features of the vascularization and changes that occur during physiological processes that were not previously seen on B-mode encourage a reassessment of the concepts already established on the events of the reproductive physiology of animals and their applications. Review: In attempt to re-understand the equine reproductive physiology and finding practical uses to this new technique, authors showed that, during the follicular deviation, features are observed by Doppler before being observed under B-mode ultrasound like changes in the speed of the blood flow two days before deviation of the follicle size and one day before the increase in blood flow area of the follicular wall. According to another study ovulation is characterized by a decreased blood flow of the follicular wall in the last four hours preceding it, as well as the serration of the granulosa layer and formation of a non vascularized apex, but in our ongoing study, the ability to decrease the vascularity was not found. Very vascularized follicles are associated with higher rates of oocyte maturation and pregnant that does less vascularized follicles in the preovulatory phase. Those follicles that have septated evacuation (or prolonged) showed more vascularization and serration of the granulosa one hour before ovulation than follicles that ovulate normally, and this vascularization includes the apex of the follicle, the follicular wall portion that is not vascularized in normal ovulation. Another study reported that hemorrhagic follicles have better vascularization of the follicular wall on the days preceding ovulation than follicles destined to ovulate. Some authors also showed that anovulatory follicles grow in size at the same rate as ovulatory follicles, but the percentage of vascularization of its wall is much smaller at 35 mm. Another study characterized that the vascular wall of the follicle that results in the first ovulation of the year is much smaller on the day before ovulation than the number of vessels present in a follicle that will ovulate in the middle of the breeding season. In these cases, the use of Doppler ultrasound can help to prevent economic losses as insemination of mares in cycles that are not able of resulting in pregnancy. This review aims to gather the information found in the literature about the characteristics of follicular hemodynamic of mares taking into account moments of deviation in follicle size, ovulation, ovulation failure and follicular viability. Conclusion: The Doppler technology has the potential to provide important information about the follicular environment and thus be used in practice in search of the perfect equine reproductive management, achieving better utilization of genetic material and increasing the financial return. The use of this new tool opens a large area for several interesting studies that will contribute to the knowledge of the physiological events of the mare for that this technique can soon be effectively applied.
Resumo:
Background: Studies with Doppler ultrassonography started at the end of the 90s for the determination of physiological and pathological alterations in the reproductive tract of the mare. Uterine alterations caused by inflammation, response from seminal plasma infusion, hormonal variations during estrous and diestrus, pregnancy and action of various vasoactive factors influence on the vascular perfusion detected by Doppler ultrasound. The development of efficient methods for uterine quality evaluation is of big importance for field equine reproduction veterinarians, once uterine environment is responsible for pregnancy maintenance. Review: Nowadays, the most used methods of uterine evaluation are the mode B ultrassonography, cytology, culture and biopsy. Hemodynamic evaluation of the uterus can be done by spectral data collected from large vessels, as A. uterine and its ramifications, or from subjective or objective evaluations from endometrium, miometrium and mesometrium attachment, which provide data referent to local and specific alterations of the evaluated area. Alterations in uterine vascular perfusion has been detected during estrous cycle, during pregnancy and in cases of infusion of inflammatory substances. These alterations happen because of vasoactive substances that act in the uterus during these events, however, most of these vasoactive substances are probably not even known. Also, important hemodynamic alterations in old mares, as an increase in vascular resistance, have been described. This increase might result from fibrosis of the uterus and in women it is considered to be a cause of infertility. In mares, periglandular fibrosis of the endometrium is considered to be the major diagnosable cause of embryonic and fetal loss in older mares. For the CL, ovarian artery of the mare supplies the ovary as well as the oviduct and therefore can be used for evaluation of these areas. The CL evaluation can also be done by the percentage of luteum area with colored signals as an indicator of the extent of blood flow. The percentage of the CL area with colored signals is determined subjectively by images observations in real time and/or by a freezing Power Doppler cross-section image with the maximum number of color pixels taped and the total number of color pixels is assessed by a computer analysis system. Therefore, a high correlation between plasmatic progesterone and CL vascularization also allows the CL evalution by this technique. In a first report, CL circulation reached its maximum on D5, the progesterone concentration in peripheral blood increased until D7 and in a posterior report, maximum perfusion was achieved two days after the maximum progesterone concentration (D8). Blood flow reduced between D10-D14 some days before the plasma progesterone decrease and, during the luteolytic period (D15-D17), the decline in CL blood-flow area was greater than blood flow decrease. Conclusion: Doppler ultrassonography add knowledge about uterine viability and CL functionality can be easily used by veterinarians in the field. It is a noninvasive method that provides real time results. However, because of the short time studies in this area have been done, many other answers still need to be found until normal and pathological patterns will be established.
Resumo:
Pós-graduação em Biotecnologia Animal - FMVZ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJECTIVE: The objective of our study was to establish optimal perfusion conditions for high-resolution postmortem angiography that would permit dynamic visualization of the arterial and venous systems. MATERIALS AND METHODS: Cadavers of two dogs and one cat were perfused with diesel oil through a peristaltic pump. The lipophilic contrast agent Lipiodol Ultra Fluide was then injected, and angiography was performed. The efficiency of perfusion was evaluated in the chick chorioallantoic membrane. RESULTS: Vessels could be seen up to the level of the smaller supplying and draining vessels. Hence, both the arterial and the venous sides of the vascular system could be distinguished. The chorioallantoic membrane assay revealed that diesel oil enters microvessels up to 50 microm in diameter and that it does not penetrate the capillary network. CONCLUSION: After establishing a postmortem circulation by diesel oil perfusion, angiography can be performed by injection of Lipiodol Ultra Fluide. The resolution of the images obtained up to 3 days after death is comparable to that achieved in clinical angiography.
Resumo:
Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Doppler ultrasonography is a new technology that has been study by researchers to improve the physiologic and pathologic knowledge about reproduction. This technology is based on Doppler-shifts frequencies or ultrasonic, these frequencies can be increase or decrease according to the movements of the red cells in the vessel. Color Doppler and power Doppler are the two possibilities to use the Doppler ultrasonography. Color Doppler is based in more the one color that show the direction of the blood f low and power Doppler is based in one color that change according of the flow intensity. Doppler ultrasonography can be demonstrated with the spectral mode to verify blood flow in large vessels, because of this, it is not use in equine reproduction. Studies in equine reproduction have been doing to verify uterus blood flow in cyclic mares and to observe the vascular perfusion in mares with cists, uterine vascular perfusion post breeding and verify the affects of drugs to decrease the uterus fluid in mares with problems in uterus perfusion. The ovarian irrigation during the estrus cycle was analyze with the measurement of the principal hormones during the estrus cycle in mares, the integrity of the corpus luteus, the irrigation of the future dominant follicle and the consequences in the ovarian irrigation after luteolyse induction also were study. Nevertheless, more than the knowledge that existed about Doppler ultrasonography, new studies have been doing to improve the forms to use Doppler ultrasonography in equine reproduction
Resumo:
A number of studies conducted in humans and in animals have observed that events occurring early in life are associated with the development of diseases in adulthood. Salt overload and restriction during pregnancy and lactation are responsible for functional (hemodynamic and hormonal) and structural alterations in adult offspring. Our group observed that lower birth weight and insulin resistance in adulthood is associated with salt restriction during pregnancy On the other hand, perinatal salt overload is associated with higher blood pressure and higher renal angiotensin II content in adult offspring. Therefore, we hypothesised that renin-angiotensin system (RAS) function is altered by changes in sodium intake during pregnancy. Such changes may influence fetoplacental blood flow and thereby fetal nutrient supply, with effects on growth in utero and, consequently, on birth weight. Female Wistar rats were fed low-salt (LS), normal-salt (NS), or high-salt (HS) diet, starting before conception and continuing until day 19 of pregnancy, Blood pressure, heart rate, fetuses and dams` body weight, placentae weight and litter size were measured on day 19 of pregnancy. Cardiac output, uterine and placental blood flow were also determined on day 19. Expressions of renin-angiotensin system components and of the TNF-alpha gene were evaluated in the placentae. Plasma renin activity (PRA) and plasma and tissue angiotensin-converting enzyme (ACE) activity, as well as plasma and placental levels of angiotensins I, II, and 1-7 were measured. Body weight and kidney mass were greater in HS than in NS and LS dams. Food intake did not differ among the maternal groups. Placental weight was lower in LS dams than in NS and HS dams. Fetal weight was lower in the US group than in the NS and HS groups. The PRA was greater in IS dams than in NS and HS dams, although ACE activity (serum, cardiac, renal, and placental) was unaffected by the level of sodium intake. Placental levels of angiotensins I and II were lower in the HS group than in the ISIS and IS groups. Placental angiotensin receptor type 1 (AT(1)) gene expression and levels of thiobarbituric acid reactive substances (TBARS) were higher in HS dams, as were uterine blood flow and cardiac output. The degree of salt intake did not influence plasma sodium, potassium or creatinine. Although fractional sodium excretion was higher in HS dams than in NS and LS dams, fractional potassium excretion was unchanged. In conclusion, findings from this study indicate that the reduction in fetal weight in response to salt restriction during pregnancy does not involve alterations in uterine-placental perfusion or the RAS. Moreover, no change in fetal weight is observed in response to salt overload during pregnancy. However, salt overload did lead to an increase in placental weight and uterine blood flow associated with alterations in maternal plasma and placental RAS. Therefore, these findings indicate that changes in salt intake during pregnancy lead to alterations in uterine-placental perfusion and fetal growth. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
This paper aims to describe the uterine and ovarian ultrasonographic characteristics and Doppler velocimetric features of their arteries in bitches during the periovulatory period. Fifteen estrous cycles in 10 animals were evaluated. The ultrasonographic characteristics, resistance indices (RI) and pulsatility indices (PI) of the uterus and ovaries in each animal were recorded 5 days before and after ovulation (D0). The data were statistically analyzed, and the results were expressed as the mean ± standard error of mean (P<0.05). In results the ultrasonographic features of the uterus were the same on all of the cycles and evaluated days. The uterus had an average diameter of 0.85±0.02cm. An increase in the volume of the ovaries and the diameter of the ovarian follicles were measured. Ovaries had a volume of 0.64±0.06cm³, and the follicles cavities had a diameter of 0.46 ± 0.01 cm on the day of ovulation. After ovulation, it was observed that some follicles not collapse in some cycles. Two days prior to ovulation, the uterine blood perfusion decreased. This decrease remained unchanged until ovulation. Following ovulation, we measured a gradual increase in the uterine perfusion and in the ovarian artery. This artery directed blood flow to the ovaries and increased the intra-ovarian perfusion on the day after ovulation. In conclusion, specific features are observed in the uterus and ovarian ultrasound image and Doppler values of their arteries presented on the periovulatory days and when associated allow to estimate more accurately the date of ovulation.