933 resultados para Tropical climate


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Daylighting in tropical and sub-tropical climates presents a unique challenge that is generally not well understood by designers. In a sub-tropical region such as Brisbane, Australia the majority of the year comprises of sunny clear skies with few overcast days and as a consequence windows can easily become sources of overheating and glare. The main strategy in dealing with this issue is extensive shading on windows. However, this in turn prevents daylight penetration into buildings often causing an interior to appear gloomy and dark even though there is more than sufficient daylight available. As a result electric lighting is the main source of light, even during the day. Innovative daylight devices which redirect light from windows offer a potential solution to this issue. These devices can potentially improve daylighting in buildings by increasing the illumination within the environment decreasing the high contrast between the window and work regions and deflecting potentially glare causing sunlight away from the observer. However, the performance of such innovative daylighting devices are generally quantified under overcast skies (i.e. daylight factors) or skies without sun, which are typical of European climates and are misleading when considering these devices for tropical or sub-tropical climates. This study sought to compare four innovative window daylighting devices in RADIANCE; light shelves, laser cut panels, micro-light guides and light redirecting blinds. These devices were simulated in RADIANCE under sub-tropical skies (for Brisbane) within the test case of a typical CBD office space. For each device the quantity of light redirected and its distribution within the space was used as the basis for comparison. In addition, glare analysis on each device was conducted using Weinold and Christoffersons evalglare. The analysis was conducted for selected hours for a day in each season. The majority of buildings that humans will occupy in their lifetime are already constructed, and extensive remodelling of most of these buildings is unlikely. Therefore the most effective way to improve daylighting in the near future will be through the alteration existing window spaces. Thus it will be important to understand the performance of daylighting systems with respect to the climate it is to be used in. This type of analysis is important to determine the applicability of a daylighting strategy so that designers can achieve energy efficiency as well the health benefits of natural daylight.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates energy saving potential of commercial building by living wall and green façade system using Envelope Thermal Transfer Value (ETTV) equation in Sub-tropical climate of Australia. Energy saving of four commercial buildings was quantified by applying living wall and green façade system to the west facing wall. A field experimental facility, from which temperature data of living wall system was collected, was used to quantify wall temperatures and heat gain under controlled conditions. The experimental parameters were accumulated with extensive data of existing commercial building to quantify energy saving. Based on temperature data of living wall system comprised of Australian native plants, equivalent temperature of living wall system has been computed. Then, shading coefficient of plants in green façade system has been included in mathematical equation and in graphical analysis. To minimize the air-conditioned load of commercial building, therefore to minimize the heat gain of commercial building, an analysis of building heat gain reduction by living wall and green façade system has been performed. Overall, cooling energy performance of commercial building before and after living wall and green façade system application has been examined. The quantified energy saving showed that only living wall system on opaque part of west facing wall can save 8-13 % of cooling energy consumption where as only green façade system on opaque part of west facing wall can save 9.5-18% cooling energy consumption of commercial building. Again, green façade system on fenestration system on west facing wall can save 28-35 % of cooling energy consumption where as combination of both living wall on opaque part of west facing wall and green façade on fenestration system on west facing wall can save 35-40% cooling energy consumption of commercial building in sub-tropical climate of Australia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates cooling energy performance of commercial building before and after green roof and living wall application based on integrated building heat gain model developed from Overall Thermal Transfer Value (OTTV) of building wall and steady state heat transfer process of roof in sub-tropical climate. Using the modelled equation and eQUEST energy simulation tool, commercial building envelope parameters and relevant heat gain parameters have been accumulated to analyse the heat gain and cooling energy consumption of commercial building. Real life commercial building envelope and air-conditioned load data for the sub-tropical climate zone have been collected and compared with the modelled analysis. Relevant temperature data required for living wall and green roof analysis have been collected from experimental setup comprised of both green roof and west facing living wall. Then, Commercial building heat flux and cooling energy performance before and after green roof and living wall application have been scrutinized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To determine whether the seroprevalence of antibodies to varicella zoster virus (VZV) in adults is similar to that reported in tropical populations elsewhere. METHODS We measured the seroprevalence of VZV IgG antibodies, using an enzyme immunoassay (EIA) in women attending an antenatal clinic in an urban centre in tropical Australia. RESULTS The overall seroprevalence of VZV antibodies in 298 women was 92% (95% CI 88-95), with no difference between women who spent their childhoods in the tropics and colleagues. None of the overseas-born women was seronegative. CONCLUSION The seroprevalence of VZV antibodies in this tropical population in Australia is as high as that reported from temperate regions, suggesting that social and cultural factors and population mobility are more important determinants of age distribution of VZV immunity than tropical climate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indústrias metalúrgicas de produção de ligas metálicas podem por em risco toda a área envolvente, nomeadamente a qualidade das águas (superficiais e subterrâneas), dos solos e do ar, sempre que não existam infraestruturas e planos adequados de gestão destes resíduos. No caso em estudo, a unidade industrial situa-se na bacia do rio São Francisco, no estado brasileiro de Minas Gerais, e nos mais de quarenta anos de funcionamento tem produzido inúmeros problemas ambientais. Este estudo baseia-se nos primeiros resultados referentes aos solos da envolvente, tendo como objetivos a identificação dos principais contaminantes e a definição da área contaminada, de forma a avaliar a eficácia de projetos futuros de recuperação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The field experiments were conducted to compare the alternate partial root-zone irrigation (APRI) with and without black plastic mulch (BPM) with full root-zone irrigation (FRI) in furrow-irrigated okra (Abelmoschus esculentus L. Moench) at Bhubaneswar, India. APRI means that one of the two neighbouring furrows was alternately irrigated during consecutive watering. FRI was the conventional method where every furrow was irrigated during each watering. The used irrigation levels were 25% available soil moisture depletion (ASMD), 50% ASMD, and 75% ASMD. The plant growth and yield parameters were observed to be significantly (p < 0.05) higher with frequent irrigation (at 25% ASMD) under all irrigation strategies. However, APRI + BPM produced the maximum plant growth and yield using 22% and 56% less water over APRI without BPM and FRI, respectively. The highest pod yield (10025 kg ha^-1) was produced under APRI at 25% ASMD + BPM, which was statistically at par with the pod yield under APRI at 50% ASMD + BPM. Irrigation water use efficiency (IWUE), which indicates the pod yield per unit quantity of irrigation water, was estimated to be highest (12.3 kg m^-3) under APRI at 50% ASMD + BPM, followed by APRI at 25% ASMD + BPM. Moreover, the treatment APRI at 50% ASMD + BPM was found economically superior to other treatments, generating more net return (US $ 952 ha^-1) with higher benefit–cost ratio (1.70).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The combined effects of shoot pruning (one or two stems) and inflorescence thinning (five or ten flowers per inflorescence) on greenhouse tomato yield and fruit quality were studied during the dry season (DS) and rainy season (RS) in Central Thailand. Poor fruit set, development of undersized (mostly parthenocarpic) fruits, as well as the physiological disorders blossom-end rot (BER) and fruit cracking (FC) turned out to be the prevailing causes deteriorating fruit yield and quality. The proportion of marketable fruits was less than 10% in the RS and around 65% in the DS. In both seasons, total yield was significantly increased when plants were cultivated with two stems, resulting in higher marketable yields only in the DS. While the fraction of undersized fruits was increased in both seasons when plants were grown with a secondary stem, the proportions of BER and FC were significantly reduced. Restricting the number of flowers per inflorescence invariably resulted in reduced total yield. However, in neither season did fruit load considerably affect quantity or proportion of the marketable yield fraction. Inflorescence thinning tended to promote BER and FC, an effect which was only significant for BER in the RS. In conclusion, for greenhouse tomato production under climate conditions as they are prevalent in Central Thailand, the cultivation with two stems appears to be highly recommendable whereas the measures to control fruit load tested in this study did not proof to be advisable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis focuses on using photovoltaic produced electricity to power air conditioners in a tropical climate. The study takes place in Surabaya, Indonesia at two different locations the classroom, located at the UBAYA campus and the home office, 10 km away. Indonesia has an average solar irradiation of about 4.8 kWh/m²/day (PWC Indonesia, 2013) which is for ideal conditions for these tests. At the home office, tests were conducted on different photovoltaic systems. A series of measuring devices recorded the performance of the 800 W PV system and the consumption of the 1.35 kW air conditioner (cooling capacity). To have an off grid system many of the components need to be oversized. The inverter has to be oversized to meet the startup load of the air conditioner, which can be 3 to 8 times the operating power (Rozenblat, 2013). High energy consumption of the air conditioner would require a large battery storage to provide one day of autonomy. The PV systems output must at least match the consumption of the air conditioner. A grid connect system provides a much better solution with the 800 W PV system providing 80 % of the 3.5 kWh load of the air conditioner, the other 20 % coming from the grid during periods of low irradiation. In this system the startup load is provided by the grid so the inverter does not need to be oversized. With the grid-connected system, the PV panel’s production does not need to match the consumption of the air conditioner, although a smaller PV array will mean a smaller percentage of the load will be covered by PV. Using the results from the home office tests and results from measurements made in the classroom. Two different PV systems (8 kW and 12 kW) were simulated to power both the current air conditioners (COP 2.78) and new air conditioners (COP 4.0). The payback period of the systems can vary greatly depending on if a feed in tariff is awarded or not. If the feed in tariff is awarded the best system is the 12 kW system, with a payback period of 4.3 years and a levelized cost of energy at -3,334 IDR/kWh. If the feed in tariff is not granted then the 8 kW system is the best choice with a lower payback period and lower levelized cost of energy than the 12 kW system under the same conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estudaram-se as alterações de atividade das enzimas musculares creatino quinase (CK), lactato desidrogenase (LDH) e aspartato aminotransferase (AST) em um grupo de cavalos que utilizados em provas de enduro de 70 e 100km de distância, em cinco competições. Os valores (U/l) basais (antes da largada) foram 245,13±9,84 para CK, 496,61±14,76 para LDH e 328,95±8,65 para AST. Todas as atividades das enzimas decresceram no primeiro momento das provas (~30km). Valores de pico, significativamente diferentes, foram alcançados para CK (413,59±50,75) imediatamente após 70km de distância; 24 horas após para LDH (628,61±33,30); e 48 horas após as provas para AST (389,89±16,96). A monitoração do período de recuperação revelou diferente comportamento entre as concentrações enzimáticas com CK retornando aos valores basais 24 horas pós-provas (279,61 ± 23,05). LDH e AST retornaram aos valores basais, 72 horas pós-provas (505,25±33,78 e 359,35±24,90, respectivamente). Os dados obtidos revelaram diferentes alterações na concentração de enzimas musculares de cavalos de enduro, diretamente relacionadas com a duração do esforço.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to determine the adaptability of Saanen and A1/2Saanen x A1/2Anglo-Nubian (A1/2SA1/2AN) goats bred in tropical climates. The study included 30 goats, 15 Saanen and 15 A1/2SA1/2AN. The data was collected during the rainy and dry seasons. During the whole experimental period, the environment variables were recorded, as well as rectal temperature (RT), superficial temperature (ST), respiratory rate (RR) and heart rate (HR) and milk production (MP). The adaptability coefficient (AC) was calculated for both genotypes. The averages were evaluated by ANOVA at 5 % probability. There was a genotype and period of year effect, as well as the interaction genotype x period of year. Pearson's simple correlation analysis was then carried out between milk production and physiological and environment variables. There was a statistical difference (p < 0.05) between the seasons for RT, ST and RR. RT, RR and HR were lower for A1/2SA1/2AN than Saanen goats, regardless of the season. MP was greater in the dry season (p < 0.05) (2.52 A +/- 0.50 kg/day for A1/2SA1/2AN and 2.41 A +/- 0.38 kg/day for Saanen) than the rainy season (2.17 A +/- 0.27 kg/day for A1/2SA1/2AN and 2.28 A +/- 0.53 kg/day for Saanen). The MP correlations were very significant (p < 0.05), however low and negative, where it was higher when correlated with RR in Saanen goats. Under the conditions of the present study, it is concluded that the goats were influenced by climatic factors, where the rainy period was more likely to cause thermal stress in the animals.