963 resultados para Transfer coefficient


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary pumped loop (CPL) and loop heat pipe (LHP) are passive two-phase heat transport devices. They have been gaining importance as a part of the thermal control system of spacecraft. The evaporation heat transfer coefficient at the tooth-wick interface of an LHP or CPL has a significant impact on the evaporator temperature. It is also the main parameter in sizing of a CPL or LHP. Experimentally determined evaporation heat transfer coefficients from a three-port CPL with tubular axially grooved (TAG) evaporator and a TAG LHP with acetone, R-134A, and ammonia as working fluids are presented in this paper. The influences of working fluid, hydrodynamic blocks in the core, evaporator configuration (LHP or CPL), and adverse elevation (evaporator above condenser) on the heat transfer coefficient are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When simulating the High Pressure Die Casting ‘HPDC’ process, the heat transfer coefficient ‘HTC’ between the casting and the die is critical to accurately predict the quality of the casting. To determine the HTC at the metal–die interface a production die for an automotive engine bearing beam, Die 1, was instrumented with type K thermocouples. A Magmasoft® simulation model was generated with virtual thermocouple points placed in the same location as the production die. The temperature traces from the simulation model were compared to the instrumentation results. Using the default simulation HTC for the metal–die interface, a poor correlation was seen, with the temperature response being much less for the simulation model. Because of this, the HTC at the metal–die interface was modified in order to get a better fit. After many simulation iterations, a good fit was established using a peak HTC of 42,000 W/m2 K, this modified HTC was further validated by a second instrumented production die, proving that the modified HTC gives good correlation to the instrumentation trials. The updated HTC properties for the simulation model will improve the predictive capabilities of the casting simulation software and better predict casting defects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mass transfer during carburising in a fluidised bed and in a steel workpiece has been studied experimentally in this work. This involved carburising experiment in an electrically heated fluidised bed at 900–970°C with natural gas and air as the atmosphere. A steel workpiece was designed to provide a range of carbon transfer surfaces of different geometries in the fluidised bed, and the carbon transfer coefficient was measured at these surfaces. The carbon transfer coefficient was determined from the carbon distribution within the diffusion layer of the sample. An empirical relationship of the carbon potential as a function of carburising atmosphere, bed temperature and fluidising velocity was determined, based on the understanding of the mass transfer mechanism and analysis of the experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The carburising of a steel workpiece with complex geometry in a fluidised bed hasbeen studied experimentally. This involved carburising experiment in an electrically heated fluidised bed at 900 - 970°C with natural gas and air as the atmosphere. The carbon transfer coefficient at the workpiece surface and diffusivity within the workpiece were determined from the carbon distribution within the diffusion layer of the sample. A reverse method and the Levenberg-Marquardt algorithm were used in the calculations. The methodology of the reverses method to extract the carbon transfer coefficient and diffusivity is also discussed in some detail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mass (e.g. carbon) transfer coefficient at a workpiece surface is an important kinetic factor to control the heat treatment process of the workpiece and to evaluate heat treatment equipment. The coefficient can be calculated from the carbon concentration at the surface of a sample carburized in a carburizing furnace for a given time. Two common measurement methods which use a thin plate and employ a component as samples respectively are evaluated and compared for sensitivity and uncertainty. The comparison shows that the use of a component produces higher measurement precision and also has the advantage in measuring the carbon transfer coefficients at different treated positions. This method is then extended and discussed methodologically. Also two equations are proposed to calculate the carbon transfer coefficient and its uncertainty, respectively. This method is also applied to measure the carbon transfer coefficient in a fluidized bed heat treatment furnace.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mass transfer coefficient is an important kinetic factor to control the thermo-chemical treatment processes of metals and alloys. More importantly, the mass transfer coefficient is different at different surface positions of a metallic part treated, which depends on the dynamic characteristics of the atmosphere close to the treated surface. Understanding the local mass transfer coefficient would be significant to approach the expected physical and mechanical properties of treated surfaces. In this paper, a reverse method was proposed to measure the mass transfer coefficient at component surface and the diffusivity in metal during heat treatment. The methodology of the reverses method and the optimal parame-ters are discussed in some detail. This method was successfully used to determine the car-bon transfer coefficient at the surface of a part in a carburizing furnace and carbon diffusiv-ity from the carbon distribution within the diffusion layer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groups of animals (Wistar rats) were fed with rations doped with uranyl nitrate at concentrations ranging from 0.5 to 100 ppm. The uranium content in the ashes of the organs was measured by the neutron-fission track counting technique. The most striking result is that the transfer coefficients, as a function of the uranium concentration, exhibit a concave shape with a minimum around 20ppm-U for all organs. Explanations to interpret this finding are tentatively given. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aerated stirred reactor (ASR) has been widely used in biochemical and wastewater treatment processes. The information describing how the activated sludge properties and operation conditions affect the hydrodynamics and mass transfer coefficient is missing in the literature. The aim of this study was to investigate the influence of flow regime, superficial gas velocity (U-G), power consumption unit (P/V-L), sludge loading, and apparent viscosity (pap) of activated sludge fluid on the mixing time (t(m)), gas hold-up (epsilon), and volumetric mass transfer coefficient (kLa) in an activated sludge aerated stirred column reactor (ASCR). The activated sludge fluid performed a non-Newtonian rheological behavior. The sludge loading significantly affected the fluid hydrodynamics and mass transfer. With an increase in the UG and P/V-L, the epsilon and k(L)a increased, and the t(m), decreased. The E, kLa, and tm,were influenced dramatically as the flow regime changed from homogeneous to heterogeneous patterns. The proposed mathematical models predicted the experimental results well under experimental conditions, indicating that the U-G, P/V-L, and mu(ap) had significant impact on the t(m) epsilon, and k(L)a. These models were able to give the tm, F, and kLa values with an error around +/- 8%, and always less than +/- 10%. (c) 2005 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A heat transfer coefficient gauge has been built, obeying particular rules in order to ensure the relevance and accuracy of the collected information. The gauge body is made out of the same materials as the die casting die (H13). It is equipped with six thermocouples located at different depths in the body and with a sapphire light pipe. The light pipe is linked to an optic fibre, which is connected to a monochromatic pyrometer. Thermocouples and pyrometer measurements are recorded with a data logger. A high pressure die casting die was instrumented with one such gauge. A set of 150 castings was done and the data recorded. During the casting, some process parameters have been modified such as piston velocity, intensification pressure, delay before switch to the intensification stage, temperature of the alloy, etc.... The data was treated with an inverse method in order to transform temperature measurements into heat flux density and heat transfer coefficient plots. The piston velocity and the initial temperature of the die seem to be the process parameters that have the greatest influence on the heat transfer. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was to investigate the impacts of operating conditions and liquid properties on the hydrodynamics and volumetric mass transfer coefficient in activated sludge air-lift reactors. Experiments were conducted in internal and external air-lift reactors. The activated sludge liquid displayed a non-Newtonian rheological behavior. With an increase in the superficial gas velocity, the liquid circulation velocity, gas holdup and mass transfer coefficient increased, and the gas residence time decreased. The liquid circulation velocity, gas holdup and the mass transfer coefficient decreased as the sludge loading increased. The flow regime in the activated sludge air-lift reactors had significant effect on the liquid circulation velocity and the gas holdup, but appeared to have little impact on the mass transfer coefficient. The experimental results in this study were best described by the empirical models, in which the reactor geometry, superficial gas velocity and/or power consumption unit, and solid and fluid properties were employed. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurements were carried out to determine local coefficients of heat transfer in short lengths of horizontal pipe, and in the region of an discontinuity in pipe diameter. Laminar, transitional and turbulent flow regimes were investigated, and mixtures of propylene glycol and water were used in the experiments to give a range of viscous fluids. Theoretical and empirical analyses were implemented to find how the fundamental mechanism of forced convection was modified by the secondary effects of free convection, temperature dependent viscosity, and viscous dissipation. From experiments with the short tube it was possible to determine simple empirical relationships describing the axial distribution of the local 1usselt number and its dependence on the Reynolds and Prandtl numbers. Small corrections were made to account for the secondary effects mentioned above. Two different entrance configurations were investigated to demonstrate how conditions upstream could influence the heat transfer coefficients measured downstream In experiments with a sudden contraction in pipe diameter the distribution of local 1u3se1t number depended on the Prandtl number of the fluid in a complicated way. Graphical data is presented describing this dependence for a range of fluids indicating how the local Nusselt number varied with the diameter-ratio. Ratios up to 3.34:1 were considered. With a sudden divergence in pipe diameter, it was possible to derive the axial distribution of the local Nusse1t number for a range of Reynolds and Prandtl numbers in a similar way to the convergence experiments. Difficulty was encountered in explaining some of the measurements obtained at low Reynolds numbers, and flow visualization techniques wore used to determine the complex flow patterns which could lead to the anomalous results mentioned. Tests were carried out with divergences up to 1:3.34 to find the way in which the local Nusselt number varied with the diameter ratio, and a few experiments were carried out with very large ratios up .to 14.4. A limited amount of theoretical analysis of the 'divergence' system was carried out to substantiate certain explanations of the heat transfer mechanisms postulated.