915 resultados para Timber elements joints


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Civil – Estruturas e Geotecnia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The assessment of existing timber structures is often limited to information obtained from non or semi destructive testing, as mechanical testing is in many cases not possible due to its destructive nature. Therefore, the available data provides only an indirect measurement of the reference mechanical properties of timber elements, often obtained through empirical based correlations. Moreover, the data must result from the combination of different tests, as to provide a reliable source of information for a structural analysis. Even if general guidelines are available for each typology of testing, there is still a need for a global methodology allowing to combine information from different sources and infer upon that information in a decision process. In this scope, the present work presents the implementation of a probabilistic based framework for safety assessment of existing timber elements. This methodology combines information gathered in different scales and follows a probabilistic framework allowing for the structural assessment of existing timber elements with possibility of inference and updating of its mechanical properties, through Bayesian methods. The probabilistic based framework is based in four main steps: (i) scale of information; (ii) measurement data; (iii) probability assignment; and (iv) structural analysis. In this work, the proposed methodology is implemented in a case study. Data was obtained through a multi-scale experimental campaign made to old chestnut timber beams accounting correlations of non and semi-destructive tests with mechanical properties. Finally, different inference scenarios are discussed aiming at the characterization of the safety level of the elements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently, the standards that deal with the determination of the properties of rigidity and strength for structural round timber elements do not take in consideration in their calculations and mathematical models the influence of the existing irregularities in the geometry of these elements. This study has as objective to determine the effective value of the modulus of longitudinal elasticity for structural round timber pieces of the Eucalyptus citriodora genus by a technique of optimization allied to the Inverse Analysis Method, to the Finite Element Method and the Least Square Method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Timber frame buildings are well known as an efficient seismic resistant structure and they are used worldwide. Moreover, they have been specifically adopted in codes and regulations during the XVIII and XIX centuries in the Mediterranean area. These structures generally consist of exterior masonry walls with timber elements embedded which tie the walls together and internal walls which have a timber frame with masonry infill and act as shearwalls. In order to preserve these structureswhich characterizemany cities in theworld it is important to better understand their behaviour under seismic actions. Furthermore, historic technologies could be used even in modern constructions to build seismic resistant buildings using more natural materials with lesser costs. Generally, different types of infill could be applied to timber frame walls depending on the country, among which brick masonry, rubble masonry, hay and mud. The focus of this paper is to study the seismic behaviour of the walls considering different types of infill, specifically: masonry infill, lath and plaster and timber frame with no infill. Static cyclic tests have been performed on unreinforced timber frame walls in order to study their seismic capacity in terms of strength, stiffness, ductility and energy dissipation. The tests showed how in the unreinforced condition, the infill is able to guarantee a greater stiffness, ductility and ultimate capacity of the wall.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Civil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

When timber elements in heritage buildings are moderately degraded by fungi and assuming underlying moisture problems have been solved, two actions can be taken: i) use a biocide to stop fungal activity; ii) consolidate the degraded elements so that the timber keeps on fulfilling its structural and decorative functions. The aim of this work is to investigate the mechanical performance of maritime pine wood degraded by fungi after being treated with a biocide followed by impregnation with a polymer product. Three commercially available products were used: a boron water-based biocide, an acrylic consolidant and an epoxy-based consolidant. Treated and consolidated specimens were subjected to mechanical tests: axial compression test (NP 618), static surface hardness (ISO 3350) and bending test (NP 619). Sets of replicates were subjected to an evaporation ageing test (EN 73) after application of the products and also tested for mechanical behaviour. An increase in mechanical strength was observed for both consolidants with no significant influence from the previous use of biocide product. The specimens subjected to ageing showed a slightly better general mechanical performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gran parte del patrimonio construido cuenta con edificios cuya estructura está compuesta por elementos de madera. El volumen económico que supone el mantenimiento y renovación de dicho patrimonio es considerable, por ello, es de especial interés el estudio de las diferentes técnicas de refuerzo aplicables a este tipo de estructuras. Las estructuras de madera han sido tradicionalmente reforzadas con piezas del mismo material, aumentando la sección de los elementos dañados, o con acero. La aparición de los materiales compuestos de polímeros reforzados con fibras, y su progresiva aplicación en obras de construcción, hizo que a principios de la década de los noventa se comenzara a aplicar este material en refuerzos de estructuras de madera (Puente de Sins, 1992). La madera es un material natural con una excelente relación entre sus características mecánicas y su peso. Con el uso de materiales compuestos como refuerzo ésta característica se mantiene. En cuanto a su modelo constitutivo, se admite un comportamiento elástico lineal a tracción paralela a la fibra hasta la rotura, mientras que a compresión, se considera un comportamiento lineal elástico inicial, seguido de un tramo plástico. En vigas de madera aserrada sometidas a flexión predomina el modo de fallo por tracción localizándose la fractura frecuentemente en el canto inferior. Los FRP tienen un comportamiento elástico lineal a tracción hasta la rotura y cuentan con excelentes propiedades mecánicas en relación a su peso y volumen. Si se refuerza la viga por el canto inferior se aumentará su capacidad de absorber tracciones y por tanto, es previsible que se produzca un incremento en la capacidad de carga, así como un aumento de ductilidad. En este trabajo se analizan los beneficios que aportan distintos sistemas de refuerzos de materiales compuestos. El objetivo es contribuir al conocimiento de esta técnica para la recuperación o aumento de las propiedades resistentes de elementos de madera sometidos a flexión. Se ha llevado a cabo un estudio basado en datos obtenidos experimentalmente mediante el ensayo a flexión de vigas de madera de pino silvestre reforzadas con materiales compuestos. Las fibras que componen los tejidos utilizados para la ejecución de los refuerzos son de basalto y de carbono. En el caso de los compuestos de fibra de basalto se aplican en distintos gramajes, y los de carbono en tejido unidireccional y bidireccional. Se analiza el comportamiento de las vigas según las variables de refuerzo aplicadas y se comparan con los resultados de vigas ensayadas sin reforzar. Además se comprueba el ajuste del modelo de cálculo no lineal aplicado para predecir la carga de rotura de cada viga reforzada. Con este trabajo queda demostrado el buen funcionamiento del FRP de fibra de basalto aplicado en el refuerzo de vigas de madera y de los tejidos de carbono bidireccionales con respecto a los unidireccionales. ABSTRACT Many of the buildings of the built heritage include a structure composed by timber elements. The economic volume involved in the maintenance and renewal of this built heritage is considerable, therefore, the study of the different reinforcement techniques applicable to this type of structure is of special interest. The wooden structures have traditionally been reinforced either with steel or with pieces of the same material, increasing the section of the damaged parts. The emergence of polymer composites reinforced with fibers, and their progressive use in construction, started to be applied as reinforcement in timber structures at the beginning of the nineties decade in the 20th century (Sins Bridge, 1992). Wood is a natural material with an excellent ratio between its mechanic characteristics and its weight. This feature is maintained with the use of composites as reinforcement. In terms of its constitutive model, linear elastic behavior parallel to the fiber up to fracture is admitted when subjected to tensile stress, while under compression, an initial linear elastic behavior, followed by a section plasticizing, is considered. In sawn timber beams subjected to bending, the predominant failure is mainly due to tensile stress; and frequently the fracture is located at the beam lower face. The FRP have a linear elastic behavior until fracture occurs, and have excellent mechanical properties in relation to their weight and volume. If the beam is reinforced by its lower face, its capacity to absorb tensile stresses will increase, and therefore, an increase in its carrying capacity is likely to be produced, as well as an increase in ductility. This work analyzes the benefits different reinforcement systems of composite materials provide, with the aim of contributing to the knowledge of this technique for recovering or increasing the strength properties of timber elements subjected to bending loads. It is a study based on data obtained experimentally using bending tests of pine timber beams reinforced with composite materials. Fibers used for the execution of the reinforcement are basalt and carbon. Basalt fiber composites are applied in different grammages, whereas with carbon composites, unidirectional and bidirectional fabrics are used. The behavior of the beams was analyzed regarding the reinforcement variables applied, and the results are compared with those of the tested beams without reinforcement. Furthermore it has been proved adjunting the nonlinear calculation model applied to predict the failure load of each reinforced beam. This work proves the good behavior of fiber reinforce plastic (FRP) with basalt fiber when applied to timber beams, and that of bidirectional carbon fabrics as opposed to the unidirectional ones.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Some of the properties sought in seismic design of buildings are also considered fundamental to guarantee structural robustness. Moreover, some key concepts are common to both seismic and robustness design. In fact, both analyses consider events with a very small probability of occurrence, and consequently, a significant level of damage is admissible. As very rare events,in both cases, the actions are extremely hard to quantify. The acceptance of limited damage requires a system based analysis of structures, rather than an element by element methodology, as employed for other load cases. As for robustness analysis, in seismic design the main objective is to guarantee that the structure survives an earthquake, without extensive damage. In the case of seismic design, this is achieved by guaranteeing the dissipation of energy through plastic hinges distributed in the structure. For this to be possible, some key properties must be assured, in particular ductility and redundancy. The same properties could be fundamental in robustness design, as a structure can only sustain significant damage if capable of distributing stresses to parts of the structure unaffected by the triggering event. Timber is often used for primary load‐bearing elements in single storey long‐span structures for public buildings and arenas, where severe consequences can be expected if one or more of the primary load bearing elements fail. The structural system used for these structures consists of main frames, secondary elements and bracing elements. The main frame, composed by columns and beams, can be seen as key elements in the system and should be designed with high safety against failure and under strict quality control. The main frames may sometimes be designed with moment resisting joints between columns and beams. Scenarios, where one or more of these key elements, fail should be considered at least for high consequence buildings. Two alternative strategies may be applied: isolation of collapsing sections and, provision of alternate load paths [1]. The first one is relatively straightforward to provide by deliberately designing the secondary structural system less strong and stiff. Alternatively, the secondary structural system and the bracing system can be design so that loss of capacity in the main frame does not lead to the collapse. A case study has been selected aiming to assess the consequences of these two different strategies, in particular, under seismic loads.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Timber connections represent the crucial part of a timber structure and a great variability exists in terms of types of connections and mechanisms. Taking as case study the widespread traditional timber frame structures, in particular the Portuguese Pombalino buildings, one of the most common timber connection is the half-lap joint. Connections play a major role in the overall behaviour of a structure, particularly when assessing their seismic response, since damage is concentrated at the connections. For this reason, an experimental campaign was designed and distinct types of tests were carried out on traditional half-lap joints to assess their in-plane response. In particular, pull-out and in-plane cyclic tests were carried out on real scale unreinforced connections. Subsequently, the connections were retrofitted, using strengthening techniques such as self-tapping screws, steel plates and GFRP sheets. The tests chosen were meant to capture the hysteretic behaviour and dissipative capacity of the connections and characterise their response and, therefore, their influence on the seismic response of timber frame walls, particularly concerning their uplifting and rotation capacity, that could lead to rocking in the walls. In this paper, the results of the experimental campaign are presented in terms of hysteretic curves, dissipated energy and equivalent viscous damping ratio. Moreover, recommendations are provided on the most appropriate retrofitting solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the application of commercial biocides to old maritime pine timber structures (Pinus pinaster Ait.) that have previously been impregnated with other products. A method was developed in the laboratory to be used in situ to determine the impregnation depth achieved by a new generation biocide product applied to timber from an old building. This timber had once been treated with an unknown product difficult to characterize without extensive analysis. The test was initially developed in laboratory conditions and later tested on elements of the roof structure of an 18th century building. In both cases the results were promising and mutually consistent with penetration depths for some treatments reaching 2.0 cm. The application in situ proved the tests viability and simplicity of execution giving a clear indication on the feasibility of possible re-treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the tensile strength of single-lap joints (SLJs) between similar and dissimilar adherends bonded with an acrylic adhesive was evaluated experimentally and numerically. The adherend materials included polyethylene (PE), polypropylene (PP), carbon-epoxy (CFRP), and glass-polyester (GFRP) composites. The following adherend combinations were tested: PE/PE, PE/PP, PE/CFRP, PE/GFRP, PP/PP, CFRP/CFRP, and GFRP/GFRP. One of the objectives of this work was to assess the influence of the adherends stiffness on the strength of the joints since it significantly affects the peel stresses magnitude in the adhesive layer. The experimental results were also used to validate a new mixed-mode cohesive damage model developed to simulate the adhesive layer. Thus, the experimental results were compared with numerical simulations performed in ABAQUS®, including a developed mixed-mode (I+II) cohesive damage model, based on the indirect use of fracture mechanics and implemented within interface finite elements. The cohesive laws present a trapezoidal shape with an increasing stress plateau, to reproduce the behaviour of the ductile adhesive used. A good agreement was found between the experimental and numerical results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The single-lap joint is the most commonly used, although it endures significant bending due to the non-collinear load path, which negatively affects its load bearing capabilities. The use of material or geometric changes is widely documented in the literature to reduce this handicap, acting by reduction of peel and shear peak stresses or alterations of the failure mechanism emerging from local modifications. In this work, the effect of using different thickness adherends on the tensile strength of single-lap joints, bonded with a ductile and brittle adhesive, was numerically and experimentally evaluated. The joints were tested under tension for different combinations of adherend thickness. The effect of the adherends thickness mismatch on the stress distributions was also investigated by Finite Elements (FE), which explained the experimental results and the strength prediction of the joints. The numerical study was made by FE and Cohesive Zone Modelling (CZM), which allowed characterizing the entire fracture process. For this purpose, a FE analysis was performed in ABAQUS® considering geometric non-linearities. In the end, a detailed comparative evaluation of unbalanced joints, commonly used in engineering applications, is presented to give an understanding on how modifications in the bonded structures thickness can influence the joint performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article studies the possibility of using market available glued-laminated timber (GLT) based on melamine-urea-formaldehyde (MUF) adhesives as an alternative to traditional solid timber sleepers. The study comprised an examination of the effect of creosote treatment on the short-term and durability after accelerated aging of the glue lines (delamination and shear strength) and the potential for full sapwood penetration by the creosote. Creosote treatment showed a negative effect on shear strength and delamination, more severe in the nonstructural than the structural GLT specimens tested. Full penetration of creosote into the sapwood was not achieved. GLT elements based on MUF adhesives can be considered an alternative to solid wood sleepers if specific grading of lamellas, proper treatment schedule, and highly controlled factory production are implemented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The integrity of multi-component structures is usually determined by their unions. Adhesive-bonding is often used over traditional methods because of the reduction of stress concentrations, reduced weight penalty, and easy manufacturing. Commercial adhesives range from strong and brittle (e.g., Araldite® AV138) to less strong and ductile (e.g., Araldite® 2015). A new family of polyurethane adhesives combines high strength and ductility (e.g., Sikaforce® 7888). In this work, the performance of the three above-mentioned adhesives was tested in single lap joints with varying values of overlap length (LO). The experimental work carried out is accompanied by a detailed numerical analysis by finite elements, either based on cohesive zone models (CZM) or the extended finite element method (XFEM). This procedure enabled detailing the performance of these predictive techniques applied to bonded joints. Moreover, it was possible to evaluate which family of adhesives is more suited for each joint geometry. CZM revealed to be highly accurate, except for largely ductile adhesives, although this could be circumvented with a different cohesive law. XFEM is not the most suited technique for mixed-mode damage growth, but a rough prediction was achieved.