986 resultados para Thickness measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The distribution of cortical bone in the proximal femur is believed to be a critical component in determining fracture resistance. Current CT technology is limited in its ability to measure cortical thickness, especially in the sub-millimetre range which lies within the point spread function of today's clinical scanners. In this paper, we present a novel technique that is capable of producing unbiased thickness estimates down to 0.3mm. The technique relies on a mathematical model of the anatomy and the imaging system, which is fitted to the data at a large number of sites around the proximal femur, producing around 17,000 independent thickness estimates per specimen. In a series of experiments on 16 cadaveric femurs, estimation errors were measured as -0.01+/-0.58mm (mean+/-1std.dev.) for cortical thicknesses in the range 0.3-4mm. This compares with 0.25+/-0.69mm for simple thresholding and 0.90+/-0.92mm for a variant of the 50% relative threshold method. In the clinically relevant sub-millimetre range, thresholding increasingly fails to detect the cortex at all, whereas the new technique continues to perform well. The many cortical thickness estimates can be displayed as a colour map painted onto the femoral surface. Computation of the surfaces and colour maps is largely automatic, requiring around 15min on a modest laptop computer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we propose a new method for measuring the thickness of the GaN epilayer, by using the ratio of the integrated intensity of the GaN epilayer X-ray diffraction peaks to that of the sapphire substrate ones. This ratio shows a linear dependence on the GaN epilayer thickness up to 2 mum. The new method is more accurate and convenient than those of using the relationship between the integrated intensity of GaN epilayer diffraction peaks and the GaN thickness. Besides, it can eliminate the absorption effect of the GaN epilayer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface tension forces are significant at millimeter length-scales, causing profoundly different flow morphologies in microchannels than in macroscale flows. The existence and morphology of thin liquid films is particularly relevant for predicting performance and operational stability of devices containing microscale two phase flows. Analytical, computational, and experimental methods previously employed in the study of thin liquid films are discussed. Thicknesses before and after a novel film morphology, referred to as a `shock,' are measured with a novel film thickness measurement technique that uses confocal microscopy. Film thicknesses predicted by previous work are compared to experimental results. Methods for increasing the accuracy of the confocal film thickness measurement technique are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A stable aqueous electrolyte film is formed between a mercury drop and a flat mica surface due to electrical double-layer repulsion when a negative potential is applied to the mercury. Film thickness has been measured as a function of applied potential while keeping the film pressure constant. By making measurements in this way, it is possible to map the data directly according to the Poisson-Boltzmann equation. An excellent fit to the data is obtained, providing direct evidence for this classical equation and its use as the basis of the Gouy-Chapman model of the diffuse double layer in electrolyte solutions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bibliography: p. 69-74.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Soil carbon stores are a major component of the annual returns required by EU governments to the Intergovernmental Panel on Climate Change. Peat has a high proportion of soil carbon due to the relatively high carbon density of peat and organic-rich soils. For this reason it has become increasingly important to measure and model soil carbon stores and changes in peat stocks to facilitate the management of carbon changes over time. The approach investigated in this research evaluates the use of airborne geophysical (radiometric) data to estimate peat thickness using the attenuation of bedrock geology radioactivity by superficial peat cover. Remotely sensed radiometric data are validated with ground peat depth measurements combined with non-invasive geophysical surveys. Two field-based case studies exemplify and validate the results. Variography and kriging are used to predict peat thickness from point measurements of peat depth and airborne radiometric data and provide an estimate of uncertainty in the predictions. Cokriging, by assessing the degree of spatial correlation between recent remote sensed geophysical monitoring and previous peat depth models, is used to examine changes in peat stocks over time. The significance of the coregionalisation is that the spatial cross correlation between the remote and ground based data can be used to update the model of peat depth. The result is that by integrating remotely sensed data with ground geophysics, the need is reduced for extensive ground-based monitoring and invasive peat depth measurements. The overall goal is to provide robust estimates of peat thickness to improve estimates of carbon stocks. The implications from the research have a broader significance that promotes a reduction in the need for damaging onsite peat thickness measurement and an increase in the use of remote sensed data for carbon stock estimations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Selection of the proper shade and color matching of restorations to natural dentition continues to be one of the most frustrating problems in dentistry and currently available shade guide presents a limited selection of colors compared to those found in natural dentition. This investigation evaluation if the composites resins shade B2 are equivalent to the Vita shade guide B2. Twelve composite resins (Renamel Microfill Super Brite- Cosmedent USA, Renamel Universal Brite- Cosmedent USA, Renamel Microfill Body- Cosmedent USA, Renamel Universal Body- Cosmedent USA, Opallis EB2-FGM, Opallis DB2-FGM, Filtek Supreme XT-3M/ESPE, Filtek Z250-3M/ESPE, Filtek Z350-3M/ESPE, Z100-3M/ESPE, 4 Seasons Dentin - Ivoclar/Vivadent, Tetric Ceram - Ivoclar/Vivadent) shade B2 were used. From each composite, two specimens were made in a steel matrix with 8.0 mm diameter and 10.0 mm different predetermined thickness (0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0 mm). The specimens were 40 seconds light polymerized by LED Ultrablue (DMC). The specimens were measured 10 times each to determine the shade using a reflectance spectrophotometer (Pocket Spec). According to results was verified that not any of composites resins shade B2 evaluated in this study presented values of color difference (ΔE) equivalent to the Vita shade guide B2 and the 2 mm thickness showed the closer match to the Vita shade guide B2.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: We estimated the diagnostic accuracy of ultrasound detrusor thickness measurement for BOO and investigated whether this method can replace PFS for the diagnosis of BOO in some patients with lower urinary tract symptoms. MATERIALS AND METHODS: Detrusor thickness was measured by linear ultrasound (7.5 MHz) at a filling volume of greater than 50% of cystometric capacity in 102 men undergoing PFS for LUTS. All patients with prior treatment for bladder outlet obstruction and those with underlying neurological disorders were excluded from analysis. Detrusor thickness was correlated with PFS data. Obstruction was defined according to the Abrams-Griffiths nomogram. RESULTS: Detrusor thickness was significantly higher (p <0.0001) in obstructed (61 cases, median detrusor thickness 2.7 mm, IQR 2.4 to 3.3) compared to unobstructed (18 cases, median detrusor thickness 1.7 mm, IQR 1.5 to 2) as well as equivocal (23 cases, median detrusor thickness 1.8 mm, IQR 1.5 to 2.2) cases. A weak to medium Spearman correlation was found between detrusor thickness and PFS parameters. For a diagnosis of BOO, detrusor thickness of 2.9 mm or greater had a positive predictive value of 100%, a negative predictive value of 54%, specificity of 100% and sensitivity of 43%. ROC analysis revealed that detrusor thickness had a high predictive value for BOO with an AUC of 0.88 (95% CI 0.81-0.94). CONCLUSIONS: In men with LUTS without prior treatment and/or neurological disorders, ultrasonographically assessed detrusor thickness 2.9 mm or greater has a high predictive value for BOO and can replace PFS for the diagnosis of BOO. However, this cutoff value needs to be validated in a larger study population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate the correlations of the global flash multifocal electroretinogram (MOFO mfERG) with common clinical visual assessments – Humphrey perimetry and Stratus circumpapillary retinal nerve fiber layer (RNFL) thickness measurement in type II diabetic patients. Methods: Forty-two diabetic patients participated in the study: ten were free from diabetic retinopathy (DR) while the remainder suffered from mild to moderate non-proliferative diabetic retinopathy (NPDR). Fourteen age-matched controls were recruited for comparison. MOFO mfERG measurements were made under high and low contrast conditions. Humphrey central 30-2 perimetry and Stratus OCT circumpapillary RNFL thickness measurements were also performed. Correlations between local values of implicit time and amplitude of the mfERG components (direct component (DC) and induced component (IC)), and perimetric sensitivity and RNFL thickness were evaluated by mapping the localized responses for the three subject groups. Results: MOFO mfERG was superior to perimetry and RNFL assessments in showing differences between the diabetic groups (with and without DR) and the controls. All the MOFO mfERG amplitudes (except IC amplitude at high contrast) correlated better with perimetry findings (Pearson’s r ranged from 0.23 to 0.36, p<0.01) than did the mfERG implicit time at both high and low contrasts across all subject groups. No consistent correlation was found between the mfERG and RNFL assessments for any group or contrast conditions. The responses of the local MOFO mfERG correlated with local perimetric sensitivity but not with RNFL thickness. Conclusion: Early functional changes in the diabetic retina seem to occur before morphological changes in the RNFL.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In cold-formed steel construction, the use of a range of thin, high strength steels (0.35 mm thickness and 550 MPa yield stress) has increased significantly in recent times. A good knowledge of the basic mechanical properties of these steels is needed for a satisfactory use of them. In relation to the modulus of elasticity, the current practice is to assume it to be about 200 GPa for all steel grades. However, tensile tests of these steels have consistently shown that the modulus of elasticity varies with grade of steel and thickness. It was found that it increases to values as high as 240 GPa for smaller thicknesses and higher grades of steel. This paper discusses this topic, presents the tensile test results for a number of steel grades and thicknesses, and attempts to develop a relationship between modulus of elasticity, yield stress and thickness for the steel grades considered in this investigation.