993 resultados para Thermal channel
Resumo:
This study aims to examine the thermal structure of the urban climate based on the interpretation of the satellite Landsat 7 (thermal channel) and measures for the area. It identifies how the production of urban climate develops based on an analysis of the structure of space forms and characteristics of land use and constructive materials in the generation of heat islands and their implications in environmental comfort in a tropical climate medium size city at Brazil. To check intra-urban air temperature, measures were carried out in mobile transects in the North-South and East-West routes. Thermal Channel data of Landsat-7, were converted to surface values. The results showed that the pattern of urbanization and characteristics of land use are responsible for the distribution of temperature generating heat islands in downtown and popular densely built neighborhoods. In those cases the highest indexes of social segregation added to higher temperature also provokes elevation in the number of illnesses and morbidity cases, mostly of respiratory diseases.
Resumo:
A 4Gbit/s directly modulated DBR laser is demonstrated with nanometre scale thermal tuning over an extended 20-70°C temperature range. >40dB side mode suppression over the entire temperature range is achieved. © 2005 Optical Society of America.
Resumo:
We perform numerical simulations of finite temperature quantum turbulence produced through thermal counterflow in superfluid 4He, using the vortex filament model. We investigate the effects of solid boundaries along one of the Cartesian directions, assuming a laminar normal fluid with a Poiseuille velocity profile, whilst varying the temperature and the normal fluid velocity. We analyze the distribution of the quantized vortices, reconnection rates, and quantized vorticity production as a function of the wall-normal direction. We find that the quantized vortex lines tend to concentrate close to the solid boundaries with their position depending only on temperature and not on the counterflow velocity. We offer an explanation of this phenomenon by considering the balance of two competing effects, namely the rate of turbulent diffusion of an isotropic tangle near the boundaries and the rate of quantized vorticity production at the center. Moreover, this yields the observed scaling of the position of the peak vortex line density with the mutual friction parameter. Finally, we provide evidence that upon the transition from laminar to turbulent normal fluid flow, there is a dramatic increase in the homogeneity of the tangle, which could be used as an indirect measure of the transition to turbulence in the normal fluid component for experiments.
Resumo:
Present work examines numerically the asymmetric behavior of hydrogen/air flame in a micro-channel subjected to a non-uniform wall temperature distribution. A high resolution (with cell size of 25 μm × 25 μm) of two-dimensional transient Navier–Stokes simulation is conducted in the low-Mach number formulation using detailed chemistry evolving 9 chemical species and 21 elementary reactions. Firstly, effects of hydrodynamic and diffusive-thermal instabilities are studied by performing the computations for different Lewis numbers. Then, the effects of preferential diffusion of heat and mass transfer on the asymmetric behavior of the hydrogen flame are analyzed for different inlet velocities and equivalence ratios. Results show that for the flames in micro-channels, interactions between thermal diffusion and molecular diffusion play major role in evolution of a symmetric flame into an asymmetric one. Furthermore, the role of Darrieus–Landau instability found to be minor. It is also found that in symmetric flames, the Lewis number decreases behind the flame front. This is related to the curvature of flame which leads to the inclination of thermal and mass fluxes. The mass diffusion vectors point toward the walls and the thermal diffusion vectors point toward the centerline. Asymmetric flame is observed when the length of flame front is about 1.1–1.15 times of the channel width.
Resumo:
This work examines analytically the forced convection in a channel partially filled with a porous material and subjected to constant wall heat flux. The Darcy–Brinkman–Forchheimer model is used to represent the fluid transport through the porous material. The local thermal non-equilibrium, two-equation model is further employed as the solid and fluid heat transport equations. Two fundamental models (models A and B) represent the thermal boundary conditions at the interface between the porous medium and the clear region. The governing equations of the problem are manipulated, and for each interface model, exact solutions, for the solid and fluid temperature fields, are developed. These solutions incorporate the porous material thickness, Biot number, fluid to solid thermal conductivity ratio and Darcy number as parameters. The results can be readily used to validate numerical simulations. They are, further, applicable to the analysis of enhanced heat transfer, using porous materials, in heat exchangers.
Resumo:
Fire safety plays a vital role in building design because appropriate level of fire safety is important to safeguard lives and property. Cold-formed steel channel sections along with fire-resistive plasterboards are used to construct light-gauge steel frame (LSF) floor systems to provide adequate fire resistance ratings (FRR). It is common practice to use lipped channel sections (LCS) as joists in LSF floor systems, and past research has only considered such systems. This research focuses on adopting improved joist sections such as hollow flange channel (HFC) sections to improve the structural performance and FRR of cold-formed LSF floor systems under standard fire conditions. The structural and thermal performances of LSF floor systems made of a welded HFC, LiteSteel Beams (LSB), with different plasterboard and insulation configurations, were investigated using four full-scale fire tests under standard fires. These fire tests showed that the new LSF floor system with LSB joists improved the FRR in comparison to that of conventional LCS joists. Fire tests have provided valuable structural and thermal performance data of tested floor systems that included time-temperature profiles and failure times, temperatures, and modes. This paper presents the details of the fire tests conducted in this study and their results along with some important findings.
Resumo:
Fire resistance of load bearing Light Gauge Steel Frame (LSF) wall systems is important to protect lives and properties in fire accidents. Recent fire tests of LSF walls made of the new cold-formed and welded hollow flange channel (HFC) section studs and the commonly used lipped channel section (LCS) studs have shown the influence of stud sections on the fire resistance rating (FRR) of LSF walls. To advance the use of HFC section studs and to verify the outcomes from the fire tests, finite element models were developed to predict the structural fire performance of LSF walls made of welded HFC section studs. The developed models incorporated the measured non-uniform temperature distributions in LSF wall studs due to the exposure of standard fire on one side, and accurate elevated temperature mechanical properties of steel used in the stud sections. These models simulated the various complexities involved such as thermal bowing and neutral axis shift caused by the non-uniform temperature distribution in the studs. The finite element analysis (FEA) results agreed well with the full scale fire test results including the FRR, outer hot and cold flange temperatures at failure and axial deformation and lateral displacement profiles. They also confirmed the superior fire performance of LSF walls made of HFC section studs. The applicability of both transient and steady state FEA of LSF walls under fire conditions was verified in this study, which also investigated the effects of using various temperature distribution patterns across the cross-section of HFC section studs on the FRR of LSF walls. This paper presents the details of this numerical study and the results.
Resumo:
Abstract: We report the growth and the electron cyclotron resonance measurements of n-type Si/Si0.62Ge0.38 and Si0.94Ge0.06/Si0.62Ge0.38 modulation-doped heterostructures grown by rapid thermal chemical vapor deposition. The strained Si and Si0.94Ge0.06 channels were grown on relaxed Si0.62Ge0.38 buffer layers, which consist of 0.6 mu m uniform Si0.62Ge0.38 layers and 0.5 mu m compositionally graded relaxed SiGe layers from 0 to 38% Ge. The buffer layers were annealed at 800 degrees C for 1 h to obtain complete relaxation. A 75 Angstrom Si(SiGe) channel with a 100 Angstrom spacer and a 300 Angstrom 2 X 10(19) cm(-3) n-type supply layer was grown on the top of the buffer layers. The cross-sectional transmission electron microscope reveals that the dense dislocation network is confined to the buffer layer, and relatively few dislocations terminate on the surface. The plan-view image indicates the threading dislocation density is about 4 X 10(6) cm(-2). The far-infrared measurements of electron cyclotron resonance were performed at 4 K with the magnetic field of 4-8 T. The effective masses determined from the slope of the center frequency of the absorption peak versus applied magnetic field plot are 0.203m(0) and 0.193m(0) for the two dimensional electron gases in the Si and Si0.94Ge0.06 channels, respectively. The Si effective mass is very close to that of a two dimensional electron gas in an Si MOSFET (0.198m(0)). The electron effective mass of Si0.94Ge0.06 is reported for the first time and is about 5% lower than that of pure Si.
Resumo:
In the present work, solidification of a hyper-eutectic ammonium chloride solution in a bottom-cooled cavity (i.e. with stable thermal gradient) is numerically studied. A Rayleigh number based criterion is developed, which determines the conditions favorable for freckles formation. This criterion, when expressed in terms of physical properties and process parameters, yields the condition for plume formation as a function of concentration, liquid fraction, permeability, growth rate of a mushy layer and thermophysical properties. Subsequently, numerical simulations are performed for cases with initial and boundary conditions favoring freckle formation. The effects of parameters, such as cooling rate and initial concentration, on the formation and growth of freckles are investigated. It was found that a high cooling rate produced larger and more defined channels which are retained for a longer durations. Similarly, a lower initial concentration of solute resulted in fewer but more pronounced channels. The number and size of channels are also found to be related to the mushy zone thickness. The trends predicted with regard to the variation of number of channels with time under different process conditions are in accordance with the experimental observations reported in the literature.
Resumo:
Bulk, melt quenched Ge18Te82-xBix glasses (1 <= x <= 4) have been found to exhibit memory type electrical switching behavior, which is in agreement with the lower thermal diffusivity values of Ge-Te-Bi samples. A linear variation in switching voltages (V-th) has been found in these samples with increase in thickness which is consistent with the memory type electrical switching. Also, the switching voltages have been found to decrease with an increase in temperature which happens due to the decrease in the activation energy for crystallization at higher temperatures. Further. V-th of Ge18Te82-xBix glasses have been found to decrease with the increase in Bi content, indicating that in the Ge-Te-Bi system, the resistivity of the additive has a stronger role to play in the composition dependence of V-th, in comparison with the network connectivity and rigidity factors. In addition, the composition dependence of crystallization activation energy has been found to show a decrease with an increase in Bi content, which is consistent with the observed decrease in the switching voltages. X-ray diffraction studies on thermally crystallized samples reveal the presence of hexagonal Te, GeTe, Bi2Te3 phases, suggesting that bismuth is not taking part in network formation to a greater extent, as reflected in the variation of switching voltages with the addition of Bi. SEM studies on switched and un-switched regions of Ge-Te-Bi samples indicate that there are morphological changes in the switched region, which can be attributed to the formation of the crystalline channel between two electrodes during switching. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The microstructure, thermal stability and hardness of ultra-fine grained (UFG) Ni produced by 12 passes of equal channel angular pressing (ECAP) through the route Bc were studied. Comparing the microstructure and hardness of the as-ECAPed samples with the published data on UFG Ni obtained after 8 passes of ECAP through the route Bc reveals a smaller average grain size (230 nm in the present case compared with 270 nm in 8-pass Ni), significantly lower dislocation density (1.08 x 10(14) m(-2) compared with 9 x 10(14) m(-2) in 8-pass Ni) and lower hardness (2 GPa compared with 2.45 GPa for 8-pass Ni). Study of the thermal stability of the 12-pass UFG Ni revealed that recovery is dominant in the temperature range 150-250A degrees C and recrystallisation occurred at temperatures > 250 A degrees C. The UFG microstructure is relatively stable up to about 400 A degrees C. Due to the lower dislocation density and consequently a lower stored energy, the recrystallisation of 12-pass ECAP Ni occurred at a higher temperature (similar to 250 A degrees C) compared with the 8-pass Ni (similar to 200 A degrees C). In the 12-pass Nickel, hardness variation shows that its dependence on grain size is inversely linear rather than the common grain size(-0.5) dependence.
Resumo:
Thermal management of distributed electronics similar to data centers is studied using a bi-disperse porous medium (BDPM) approach. The BDPM channel comprises heat generating micro-porous square blocks, separated by macro-pores. Laminar forced convection cooling fluid of Pr = 0.7 saturates both the micro- and macro-pores. Bi-dispersion effect is induced by varying the macro-pore volume fraction phi(E), and by changing the number of porous blocks N-2, both representing re-distribution of the electronics. When 0.2 <= phi(E) <= 0.86, the heat transfer No is enhanced twice (from similar to 550 to similar to 1100) while the pressure drop Delta p* reduces almost eightfold. For phi(E) < 0.5, No reduces quickly to reach a minimum at the mono -disperse porous medium (MDPM) limit (phi(E) -> 0). Compared to N-2 = 1 case, No for BDPM configuration is high when N-2 >> 1, i.e., the micro-porous blocks are many and well distributed. The Nu increase with Re changes from non-linear to linear as N-2 increases from 1 to 81, with corresponding insignificant pumping power increase. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Three-dimensional numerical study of natural convection in a vertical channel with flush-mounted discrete heaters on opposite conductive substrate walls is carried out in the present work. Detailed flow and heat transfer characteristics are presented for various Grashof numbers. The heat transfer effects on one wall by the presence of heaters on its opposite wall is examined. It is found that heat transfer rates on one wall are increased by the presence of heaters on its opposite wall. The thermal boundary layers on the opposite walls complement each other for enhanced heat transfer. The effects of spacing between the heated walls, spacings between heaters and substrate conductivity on flow and heat transfer are examined. Existence of optimum spacings between the heated walls for maximum heat transfer and mass flow are observed. It is found that the heat transfer and fluid flow do not follow the same optimum spacings. Mass flow rate reaches maximum value at a wall spacing greater than the spacing for maximum heat transfer. This is because the interaction of thermal boundary layers on individual walls ceases at a lower spacing before the velocity boundary layers separate each other. It is found that increased spacings between heaters reduce individual heater temperatures provided the heaters close to exit on both substrates avail sufficient substrate potions on the exit side. Insufficient substrate portions between the exit heaters and the exit cause abnormal local temperature rise in the exit heaters which are the hottest ones among all the heaters. Optimal heater spacings exist for minimum hottest heater temperature rise. Correlations are presented for dimensionless mass flow rate, temperature maximum, and average Nusselt number.