972 resultados para Testing conditions
Resumo:
Different types of aerosolization and deagglomeration testing systems exist for studying the properties of nanomaterial powders and their aerosols. However, results are dependent on the specific methods used. In order to have well-characterized aerosols, we require a better understanding of how system parameters and testing conditions influence the properties of the aerosols generated. In the present study, four experimental setups delivering different aerosolization energies were used to test the resultant aerosols of two distinct nanomaterials (hydrophobic and hydrophilic TiO2). The reproducibility of results within each system was good. However, the number concentrations and size distributions of the aerosols created varied across the four systems; for number concentrations, e.g., from 10(3) to 10(6) #/cm(3). Moreover, distinct differences were also observed between the two materials with different surface coatings. The article discusses how system characteristics and other pertinent conditions modify the test results. We propose using air velocity as a suitable proxy for estimating energy input levels in aerosolization systems. The information derived from this work will be especially useful for establishing standard operating procedures for testing nanopowders, as well as for estimating their release rates under different energy input conditions, which is relevant for occupational exposure.
Resumo:
In this work, the behavior of an AISI 410 martensitic stainless steel under corrosion-erosion conditions is evaluated. Quenched and tempered samples were used for the wear test, using a low velocity jet-like device connected to a potentiostat. Potentiodynamic polarization curves were obtained with the electrolyte in static state, with flow conditions and under corrosion-erosion, adding quartz particles to the electrolyte. In addition, mass loss measurements under erosion and corrosion-erosion conditions were carried out. The topography of the surfaces was examined after the wear tests, using optical and scanning electron microscopy. This information, together with the results of mass losses and the electrochemical tests were used to establish the degradation mechanisms of the stainless steels under different testing conditions. The results showed that synergism is a significant part of the degradation process of this steel (66.5%) and that the mass removal process of steel was controlled by corrosion assisted by erosion.
Resumo:
Introduction: The present study evaluated the effect of a reducing agent on the bond strength of deproteinized root canal dentin surfaces when using a self-adhesive versus dual-cured cement. Regional differences were also evaluated. Methods: A total of 45 bovine incisor roots were divided into 3 groups: irrigation with physiologic solution (control), 10-minute deproteinization with 5% NaOCl, and 10-minute deproteinization with 5% NaOCl followed by 10 minutes of 10% ascorbic acid. Fiber posts were cemented with either RelyX 0100 or RelyX ARC (with SingleBond 2 or Clearfil SE Bond). The push-out bond strength was evaluated after 24 hours of storage. Data were submitted to three-way analyses of variance and Dunnett 13 tests (alpha = 0.05). Results: No differences between cements were observed within the testing conditions, regardless of the adhesive (P < .05). Deproteinization reduced bond strengths. Subsequent treatment with ascorbic acid was capable of reversing bond strength value changes to levels similar to those of controls. Regional radicular differences were also found, where coronal > middle > apical. Conclusions: The reducing agent was capable. of reversing the effect of dentin deproteinization, and RelyX U100 behaved similarly to RelyX ARC. (J Endod 2010;36:130-134)
Resumo:
OBJECTIVE:: To evaluate the chromatic pupillary response as a means of assessing outer and inner retinal function in patients with retinitis pigmentosa (RP). DESIGN:: Evaluation of diagnostic technology. PARTICIPANTS:: Thirty-two patients with RP and visual loss and 43 normal subjects. METHODS:: Patients were tested with a chromatic pupillometer using red and blue lights (1, 10, and 100 cd/m(2)), and their pupil responses were compared with those from 43 normal subjects (reported previously). Visual field and electroretinography (ERG) results were examined and compared with the pupil responses. MAIN OUTCOME MEASURES:: The percent pupil contraction of the transient response to a low-intensity (1 cd/m(2)) blue light and high-intensity (100 cd/m(2)) red light and the sustained response to a high-intensity blue light was calculated for 1 eye of each subject. RESULTS:: The pupil responses to red and blue light at all intensities were recordable in all patients except 1, whose pupil responded only to bright blue light. There was a significant difference of the pupil response between patients with RP and normal subjects in testing conditions that emphasized rod (1 cd/m(2) blue light) or cone (100 cd/m(2) red light) contribution (P<0.001). Patients with a non-recordable scotopic ERG showed significantly reduced pupil responses (P<0.001) to low-intensity blue light (1 cd/m(2)). Patients with a non-recordable or abnormal photopic ERG showed significantly reduced pupil responses (P<0.05) to high-intensity red light (100 cd/m(2)). Patients with a nonrecordable ERG had the most visual field loss and reduced pupil responses. Unexpectedly, patients with RP showed a slower re-dilation of the pupil after termination of bright blue light compared with red light, a pattern not observed in normal subjects. CONCLUSIONS:: Pupil responses to red and blue light stimuli weighted to favor cone or rod input are significantly reduced in patients with RP but are still recordable in patients having a non-recordable ERG. In addition, outer photoreceptor disease appears to unmask a post-illumination pupillary constriction to bright blue light, most likely mediated by intrinsic activation of melanopsin ganglion cells. Chromatic pupillometry provides a novel, noninvasive method for following retinal functional status, particularly in patients with severe RP and non-recordable ERG. FINANCIAL DISCLOSURE(S):: Proprietary or commercial disclosure may be found after the references.
Resumo:
Pavements are subjected to different stresses during their design lives. A properly designed pavement will perform adequately during its design life, and the distresses will not exceed the allowable limits; however, there are several factors that can lead to premature pavement failure. One such factor is moisture sensitivity. AASHTO T 283 is the standard test used in the moisture susceptibility evaluation of asphalt mixtures, but the results of the test are not very representative of the expected behavior of asphalt mixtures. The dynamic modulus test measures a fundamental property of the mixture. The results of the dynamic modulus test can be used directly in the Mechanistic-Empirical Pavement Design Guide (MEPDG) and are considered a very good representation of the expected field performance of the mixture. Further research is still needed to study how the dynamic modulus results are affected by moisture. The flow number test was studied in previous research as a candidate test for moisture-susceptibility evaluation, but the results of that research were not favorable. This research has four main objectives. The first objective of this research is to evaluate the usefulness of the dynamic modulus and flow number tests in moisture-susceptibility evaluation. The second objective is to compare the results to those achieved using the AASHTO T 283 test. The third objective is to study the effect of different methods of sample conditioning and testing conditions. The fourth objective of the research is to study the variability in the test results.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Resumo:
The catalytic combustion of methane on alumina supported palladium catalysts was studied. It has been reported that the activity of the catalyst increases with its time on line, despite of an increase of the palladium particle size. However, different preparation, pretreatment and testing conditions can be the reason for the observed different results. An experimental design, which allows to verify the influence of several parameters at the same time with a good statistical quality, was used. A Plackett-Burman design was selected for the screening of the variables which have an effect on the increase of the catalyst activity.
Resumo:
Studies of behavior, endocrinology and physiology have described experiments in which animals housed in groups or in isolation were normally tested individually. The isolation of the animal from its group for testing is perhaps the most common situation used today in experimental procedures, i.e., there is no consideration of the acute stress which occurs when the animal is submitted to a situation different from that it is normally accustomed to, i.e., group living. In the present study, we used 90 male 120-day-old rats (Rattus norvegicus) divided into 5 groups of 18 animals, which were housed 3 per cage, in a total of 6 cages. The animals were tested individually or with their groups for exploratory behavior. Hormones were determined by radioimmunoassay using specific kits. The results showed statistically significant differences between testing conditions in terms of behavior and of adrenocorticotrophic hormone (ACTH: from 116.8 ± 15.27 to 88.77 ± 18.74 when in group and to 159.6 ± 11.53 pg/ml when isolated), corticosterone (from 561.01 ± 77.04 to 1036.47 ± 79.81 when in group and to 784.71 ± 55.88 ng/ml when isolated), luteinizing hormone (from 0.84 ± 0.09 to 0.58 ± 0.05 when in group and to 0.52 ± 0.06 ng/ml when isolated) and prolactin (from 5.18 ± 0.33 to 9.37 ± 0.96 when in group and to 10.18 ± 1.23 ng/ml when isolated) secretion, but not in terms of follicle-stimulating hormone or testosterone secretion. The most important feature observed was that in each cage there was one animal with higher ACTH levels than the other two; furthermore, the exploratory behavior of this animal was different, indicating the occurrence of almost constant higher vigilance in this animal (latency to leave the den in group: 99.17 ± 34.95 and isolated: 675.3 ± 145.3 s). The data indicate that in each group there is an animal in a peculiar situation and its behavior can be detected by ACTH determination in addition to behavioral performance.
Resumo:
Le vieillissement normal est souvent associé à des changements cognitifs négatifs, notamment sur les performances cognitives. Cependant, des changements comportementaux et cérébraux positifs ont aussi été observés. Ces modifications indiquent l’existence d’une plasticité cérébrale dans le vieillissement normal. Ainsi, plusieurs facteurs ont été étudiés afin de mieux connaitre les modulateurs de cette plasticité dite positive. La plupart des études évaluant ce phénomène ont utilisé la technique d’imagerie par résonance magnétique alors que la technique des potentiels évoqués a été beaucoup moins utilisée. Cette technique est basée sur les enregistrements de l’activité électrique cérébrale très sensible aux changements anatomiques associés au vieillissement et permet donc d’observer de manière précise les variations du décours temporel des ondes éléctrophysiologiques lors du traitement des informations. Les travaux de cette thèse visent à étudier les modifications de plasticité cérébrale induites par des facteurs protecteurs/préventifs du vieillissement normal et notamment lors de la réalisation de tâches impliquant le contrôle attentionnel, grâce à l’analyse de signaux électroencéphalographiques en potentiels évoqués. Dans un premier temps, une description de l’analyse des données EEG en potentiels évoqués sera fournie, suivie d’une revue de littérature sur le contrôle attentionnel et les facteurs de plasticité dans le vieillissement normal (Chapitre 1). Cette revue de littérature mettra en avant, d’une part la diminution des capacités de contrôle de l’attention dans le vieillissement et d’autre part, les facteurs protecteurs du vieillissement ainsi que la plasticité cérébrale qui leur est associée. Ces facteurs sont connus pour avoir un effet positif sur le déficit lié à l’âge. La première étude de ce projet (Chapitre 2) vise à définir l’effet d’un facteur de réserve cognitive, le niveau d’éducation, sur les composantes des potentiels évoqués chez les personnes âgées. Cette étude mettra en avant une composante des potentiels évoqués, la P200, comme indice de plasticité lorsqu’elle est liée au niveau d’éducation. Cet effet sera observé sur deux tâches expérimentales faisant intervenir des processus de contrôle attentionnel. De plus, une différence d’épaisseur corticale sera observée : les personnes âgées ayant un plus haut niveau d’éducation ont un cortex cingulaire antérieur plus épais. La deuxième étude (Chapitre 3) cherche à déterminer, chez les personnes âgées, les modifications comportementales et en potentiels évoqués induites par trois entraînements cognitifs, entrainements visant l’amélioration de processus attentionnels différents : l’attention focalisée, l’attention divisée, ainsi que la modulation de l’attention. Au niveau comportemental, les entraînements induisent tous une amélioration des performances. Cependant, l’entraînement en modulation de l’attention est le seul à induire une amélioration du contrôle attentionnel. Les résultats éléctrophysiologiques indiquent la N200 comme composante sensible à la plasticité cérébrale à la suite d’entraînements cognitifs. L’entraînement en modulation de l’attention est le seul à induire une modification de cette composante dans toutes les conditions des tests. Les résultats de ces études suggèrent que les facteurs protecteurs du vieillissement permettent des changements positifs observés en potentiels évoqués. En effet, nous mettons en évidence des phénomènes de plasticité cérébrale des personnes âgées qui diffèrent selon leurs origines. L’impact de ces résultats ainsi que les limites et perspectives futures seront présentés en fin de thèse (Chapitre 4).
Resumo:
Au niveau méthodologique, ce travail innove en combinant plusieurs moyens d'observation complémentaires sur le processus d'écriture et sur le processus de correction. Les observations qualitatives ainsi recueillies sont retranscrites en les combinant selon l'ordre chronologique d'apparition, puis elles sont traitées et analysées sous le logiciel QDA Miner.