1000 resultados para Tariff systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research analyses the former and the current status of the small gas-motor power plant investments in the Hungarian energy sector. It discusses the development of project financing in the segment and the major changes and effects of new regulations and subsidy-policy implemented in 2010. The objective of this paper is to present the results of an empirical research of the so called GCHP projects, and to draw conclusion concerning how classic project financing conditions were present and changed during the last decade, and how regulation affected the current and future financial status of these projects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste trabalho foi analisar o consumo e o custo de energia elétrica em cultura do feijoeiro irrigado por pivô central, cultivar IAC-Carioca, submetida a dois manejos de irrigação: TENS - tensiometria; TCA - balanço hídrico-climatológico, baseado no tanque Classe A; e dois sistemas de cultivo em Latossolo Vermelho: PD - plantio direto; PC - plantio convencional, no ano de 2002. A pesquisa foi desenvolvida na Área Demonstrativa e Experimental de Irrigação - ADEI da FCAV/UNESP, Câmpus de Jaboticabal - SP. O consumo de energia elétrica do sistema de irrigação foi monitorado, e seu custo, analisado para dois grupos tarifários: A e B, sendo os preços do kWh dos sistemas tarifários de energia elétrica obtidos na CPFL (Companhia Paulista de Força e Luz). Os tratamentos em que o manejo da irrigação foi realizado pelo método do tanque Classe A, ocasionaram os maiores consumos e custos de energia elétrica, em relação aos tratamentos em que o manejo foi realizado por tensiometria; entre os sistemas de plantio, não foram observadas diferenças. A tarifa Horo-Sazonal (verde e/ou azul), com desconto, foi a melhor opção para os quatro tratamentos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this work was to analyze the consumption, electric energy cost, and economic results of irrigated citrus (Citrus sinensis). The treatments consisted of a dripping irrigation system with one and two lateral distribution lines, a micro sprinkler irrigation system and a treatment without irrigation. For each irrigation system, three water depths were used: 100%, 75% and 50% of Etc (citrus evapotranspiration). The electric energy cost for two tariff groups, Group A and Group B, was studied. For Group A, the expenses with energy were determined for the Conventional Binomial Structure tariff, the Hour-seasonal tariff (green and blue) and the special tariff for nocturnal irrigation. The kWh cost for the tariff systems were obtained from the website of CPFL (São Paulo State Power and Light Company, Brazil). The best relation between the electric energy consumption (kWh.ha -1) and productivity (t.ha -1) occurred in the treatment irrigated with 50% of the Etc. The irrigated treatments increased productivity. The biggest productivity was observed in the irrigation treatments with 50% of the Etc when compared to the ones with 100% of the Etc. The blue and green Hour-seasonal tariff system of Group A (nocturnal irrigation) was the best option. A biggest economic turnover occurred in the treatments irrigated with 50% of the Etc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of Electric Vehicles (EVs) will change significantly the planning and management of power systems in a near future. This paper proposes a real-time tariff strategy for the charge process of the EVs. The main objective is to evaluate the influence of real-time tariffs in the EVs owners’ behaviour and also the impact in load diagram. The paper proposes the energy price variation according to the relation between wind generation and power consumption. The proposed strategy was tested in two different days in the Danish power system. January 31st and August 13th 2013 were selected because of the high quantities of wind generation. The main goal is to evaluate the changes in the EVs charging diagram with the energy price preventing wind curtailment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper was to develop a model for calculating the economical flow diameter and velocity, by obtaining the economical diameter, using Swamee's friction factor equation, by minimizing the total annual cost. The application of the model to a regular supply condition showed that the diameter of the actual condition, 250 mm, compared with the diameter calculated by the mode, at the same tariff as that applied to the property ( ground), 284.1 mm, involved the necessity to generate, transmit, and distribute extra electrical energy, due to the higher load loss caused by the original diameter, approximately 30800 kWh/year. This means that in one year, the consumer would spend R$2,804.00 more on pumping cost alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We provide a theory of trade policy determination that incorporates the protectionist bias inherent in majoritarian systems, suggested by Grossman and Helpman (2005). The prediction that emerges is that in majoritarian systems, the majority party favors industries located disproportionately in majority districts. We test this prediction using U.S. tariff data from 1993, and House campaign contribution data from two electoral cycles. We find evidence of a protectionist bias due to majoritarian system politics that is comparable in magnitude to the payoff from being an organized industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development and maintenance of the sealing of the root canal system is the key to the success of root canal treatment. The resin-based adhesive material has the potential to reduce the microleakage of the root canal because of its adhesive properties and penetration into dentinal walls. Moreover, the irrigation protocols may have an influence on the adhesiveness of resin-based sealers to root dentin. The objective of the present study was to evaluate the effect of different irrigant protocols on coronal bacterial microleakage of gutta-percha/AH Plus and Resilon/Real Seal Self-etch systems. One hundred ninety pre-molars were used. The teeth were divided into 18 experimental groups according to the irrigation protocols and filling materials used. The protocols used were: distilled water; sodium hypochlorite (NaOCl)+eDTA; NaOCl+H3PO4; NaOCl+eDTA+chlorhexidine (CHX); NaOCl+H3PO4+CHX; CHX+eDTA; CHX+ H3PO4; CHX+eDTA+CHX and CHX+H3PO4+CHX. Gutta-percha/AH Plus or Resilon/Real Seal Se were used as root-filling materials. The coronal microleakage was evaluated for 90 days against Enterococcus faecalis. Data were statistically analyzed using Kaplan-Meier survival test, Kruskal-Wallis and Mann-Whitney tests. No significant difference was verified in the groups using chlorhexidine or sodium hypochlorite during the chemo-mechanical preparation followed by eDTA or phosphoric acid for smear layer removal. The same results were found for filling materials. However, the statistical analyses revealed that a final flush with 2% chlorhexidine reduced significantly the coronal microleakage. A final flush with 2% chlorhexidine after smear layer removal reduces coronal microleakage of teeth filled with gutta-percha/AH Plus or Resilon/Real Seal SE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effectiveness of Reciproc for the removal of cultivable bacteria and endotoxins from root canals in comparison with multifile rotary systems. The root canals of forty human single-rooted mandibular pre-molars were contaminated with an Escherichia coli suspension for 21 days and randomly assigned to four groups according to the instrumentation system: GI - Reciproc (VDW); GII - Mtwo (VDW); GIII - ProTaper Universal (Dentsply Maillefer); and GIV -FKG Race(™) (FKG Dentaire) (n = 10 per group). Bacterial and endotoxin samples were taken with a sterile/apyrogenic paper point before (s1) and after instrumentation (s2). Culture techniques determined the colony-forming units (CFU) and the Limulus Amebocyte Lysate assay was used for endotoxin quantification. Results were submitted to paired t-test and anova. At s1, bacteria and endotoxins were recovered in 100% of the root canals investigated (40/40). After instrumentation, all systems were associated with a highly significant reduction of the bacterial load and endotoxin levels, respectively: GI - Reciproc (99.34% and 91.69%); GII - Mtwo (99.86% and 83.11%); GIII - ProTaper (99.93% and 78.56%) and GIV - FKG Race(™) (99.99% and 82.52%) (P < 0.001). No statistical difference were found amongst the instrumentation systems regarding bacteria and endotoxin removal (P > 0.01). The reciprocating single file, Reciproc, was as effective as the multifile rotary systems for the removal of bacteria and endotoxins from root canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the dentine bond strength (BS) and the antibacterial activity (AA) of six adhesives against strict anaerobic and facultative bacteria. Three adhesives containing antibacterial components (Gluma 2Bond (glutaraldehyde)/G2B, Clearfil SE Protect (MDPB)/CSP and Peak Universal Bond (PUB)/chlorhexidine) and the same adhesive versions without antibacterial agents (Gluma Comfort Bond/GCB, Clearfil SE Bond/CSB and Peak LC Bond/PLB) were tested. The AA of adhesives and control groups was evaluated by direct contact method against four strict anaerobic and four facultative bacteria. After incubation, according to the appropriate periods of time for each microorganism, the time to kill microorganisms was measured. For BS, the adhesives were applied according to manufacturers' recommendations and teeth restored with composite. Teeth (n=10) were sectioned to obtain bonded beams specimens, which were tested after artificial saliva storage for one week and one year. BS data were analyzed using two-way ANOVA and Tukey test. Saliva storage for one year reduces the BS only for GCB. In general G2B and GCB required at least 24h for killing microorganisms. PUB and PLB killed only strict anaerobic microorganisms after 24h. For CSP the average time to eliminate the Streptococcus mutans and strict anaerobic oral pathogens was 30min. CSB showed no AA against facultative bacteria, but had AA against some strict anaerobic microorganisms. Storage time had no effect on the BS for most of the adhesives. The time required to kill bacteria depended on the type of adhesive and never was less than 10min. Most of the adhesives showed stable bond strength after one year and the Clearfil SE Protect may be a good alternative in restorative procedures performed on dentine, considering its adequate bond strength and better antibacterial activity.