967 resultados para Stroke length
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of this study was to analyze changes in stroke rate (SR), stroke length (SL) and stroke phases (entry and catch, pull, push and recovery) when swimming at (MLSS) and above (102.5% MLSS) the maximal lactate steady state. Twelve endurance swimmers (21±8 year, 1.77±0.10m and 71.6±7.7kg) performed in different days the following tests: (1) 200- and 400-m all-out tests, to determine critical speed (CS), and; (2) 2-4 30-min sub-maximal constant-speed tests, to determine the MLSS and 102.5% MLSS. There was significant difference among MLSS (1.22±0.05ms-1), 102.5% MLSS (1.25±0.04ms-1) and CS (1.30±0.08ms-1). SR and SL were maintained between the 10th and 30th minute of the test swum at MLSS and have modified significantly at 102.5% MLSS (SR - 30.9±3.4 and 32.2±3.5cyclesmin-1 and SL - 2.47±0.2 and 2.38±0.2mcycle-1, respectively). All stroke phases were maintained at 10th and 30th minute at MLSS. However, the relative duration of propulsive phase B (pull) increased significantly at 102.5% MLSS (21.7±3.4% and 22.9±3.9%, respectively). Therefore, the metabolic condition may influence the stroke parameters (SR and SL) and stroke strategy to maintain the speed during swim tests lasting 30min. © 2010 Sports Medicine Australia.
Resumo:
Efficiency in front-crawl stroke has been inferred primarily by means of the analysis of arm actions, specifically, stroke frequency and stroke length. The objective of the present study was to investigate whether swimming efficiency could be better assessed in children still learning the front-crawl stroke by analyzing the movement pattern as a whole. Forty-two children enrolled in private swimming programs volunteered to participate in the study. The task consisted of swimming 30 m as fast as possible. Three experts analyzed the movement pattern of the participants using a checklist. Both stroke frequency and stroke length were calculated. The correlation coefficients between the time taken to swim and both the stroke frequency and stroke length were not significant, but the total and components of the checklist scores were. Results indicate that the swimming efficiency of children learning the front-crawl stroke can be better assessed by analyzing their whole movement pattern.
Resumo:
A percepção subjetiva de esforço (PSE) é determinada de forma não invasiva e utilizada juntamente com a resposta lactacidêmica como indicadores de intensidade durante teste incremental. em campo, especialmente na natação, há dificuldades nas coletas sanguíneas; por isso, utilizam-se protocolos alternativos para estimar o limiar anaeróbio. Assim, os objetivos do estudo foram: prescrever um teste incremental baseado na PSE (Borg 6-20) visando estimar os limiares metabólicos determinados por métodos lactacidêmicos [ajuste bi-segmentado (V LL), concentração fixa-3,5mM (V3,5mM) e distância máxima (V Dmáx)]; relacionar a PSE atribuída em cada estágio com a freqüência cardíaca (FC) e com parâmetros mecânicos de nado [freqüência (FB) e amplitude de braçada (AB)], analisar a utilização da escala 6-20 na regularidade do incremento das velocidades no teste e correlacionar os limiares metabólicos com a velocidade crítica (VC). Para isso, 12 nadadores (16,4 ± 1,3 anos) realizaram dois esforços máximos (200 e 400m); os dados foram utilizados para determinar a VC, velocidade de 400m (V400m) e a freqüência crítica de braçada (FCb); e um teste incremental com intensidade inicial baseada na PSE, respectivamente, 9, 11, 13, 15 e 17; sendo monitorados em todos os estágios a FC, lactacidêmia e os tempos de quatro ciclos de braçadas e das distâncias de 20m (parte central da piscina) e 50m. Posteriormente, foram calculadas as velocidades dos estágios, FB, AB, V LL, V3,5mM e V Dmáx. Utilizaram-se ANOVA e correlação de Pearson para análise dos resultados. Não foram encontradas diferenças entre VC, V Dmáx e V LL, porém a V3,5mM foi inferior às demais velocidades (P < 0,05). Correlações significativas (P < 0,05) foram observadas entre VC versus V400m, V Dmáx e V3,5mM; V400m versus V3,5mM e V Dmáx; V Dmáx versus V LL; e no teste incremental entre PSE versus velocidade, [Lac], FC, FB e AB (P < 0,05). Concluímos que a PSE é uma ferramenta confiável no controle da velocidade dos estágios durante teste incremental na natação.
Resumo:
O principal objetivo deste estudo foi verificar o efeito do nível de performance aeróbia na relação entre os índices técnicos correspondentes à velocidade crítica (VC) e à velocidade máxima de 30 minutos (V30) em nadadores. Participaram deste estudo, 23 nadadores do gênero masculino com características antropométricas similares, divididos segundo o nível de performance aeróbia em grupo G1 (maior performance) (n = 13) e G2 (menor performance) (n = 10). Os indivíduos tinham pelo menos quatro anos de experiência no esporte e treinavam um volume semanal de 30.000 a 45.000m. A VC foi determinada através do coeficiente angular da regressão linear entre as distâncias (200 e 400m) e seus respectivos tempos. A V30 foi determinada através da máxima distância realizada em um teste de 30 minutos. Todas as variáveis foram determinadas no nado crawl. A VC foi significantemente maior do que a V30 no grupo G1 (1,30 ± 0,04 vs. 1,23 ± 0,06m.s-1) e no G2 (1,17 ± 0,08 vs. 1,07 ± 0,06m.s-1). As duas variáveis foram maiores no grupo G1. As taxas de braçada correspondentes à VC (TBVC) e à V30 (TBV30) obtidas nos grupos G1 (33,07 ± 4,34 vs. 31,38 ± 4,15 ciclos.min-1) e G2 (35,57 ± 6,52 vs. 33,54 ± 5,89 ciclos.min-1) foram similares entre si. A TBVC foi significantemente menor no grupo 1 do que no grupo 2, enquanto que a TBV30 não foi diferente entre os grupos. Os comprimentos de braçada correspondentes à VC (CBVC) e à V30 (CBV30) foram significantemente maiores no grupo G1 (2,41 ± 0,33 vs. 2,38 ± 0,30m.ciclo-1) do que no G2 (2,04 ± 0,43 vs. 1,97 ± 0,40m.ciclo-1), e similares entre si nos dois grupos. As correlações (r) entre a VC e a V30 e as variáveis técnicas correspondentes às duas velocidades foram significantes em todas as comparações (0,68 a 0,91). Portanto, a relação entre a velocidade e as variáveis técnicas correspondentes à VC e à V30 não é modificada pelo nível de performance aeróbia.
Resumo:
O objetivo do presente estudo foi verificar a utilização da velocidade de 30 minutos (VT-30), freqüência de braçada (fB), comprimento de braçada (CB) e índice de braçada (IB), obtidos no teste T-30, como métodos não-invasivos para determinação da performance aeróbia e técnica de nadadores treinados. Catorze nadadores submeteram-se a três esforços de 400m (85, 90 e 100% do esforço máximo) para determinação da velocidade de limiar anaeróbio (VLan) correspondente à concentração fixa de 3,5mM de lactato e um esforço máximo de 30 minutos (VT-30). fB, CB e IB foram calculados nos 10m centrais da piscina (nado limpo) para o teste T-30 (fBT-30, CBT-30 e IBT-30) e progressivo. Através da relação entre VLan e parâmetros de braçada no teste progressivo, determinaram-se freqüência de braçada de limiar (fBLan), comprimento de braçada de limiar (CBLan) e índice de braçada de limiar (IBLan). O tempo para realizar 400m em máximo esforço foi considerado como parâmetro de performance (P400). Não foi encontrada diferença significativa entre VLan (1,29 ± 0,07m.s-1) e VT-30 (1,29 ± 0,08m.s-1), que ainda apresentaram alta correlação (r = 0,90). Os valores de fBLan (33,6 ± 4,14 ciclos/min) e fBT-30 (34,9 ± 3,53 ciclos/min) e de CBLan (2,09 ± 0,20m/ciclo) e CBT-30 (2,09 ± 0,20m/ciclo) também não foram significativamente diferentes. Correlações significativas (p < 0,05) também foram encontradas entre VT-30 e P400 (r = 0,95); fBLan e fBT-30 (r = 0,73); CBLan e CBT-30 (r = 0,89) e IBLan e IBT-30 (r = 0,94). Conclui-se que a VT30 se mostrou confiável para o monitoramento do treinamento, predição da performance e determinação de parâmetros relacionados à técnica de nadadores.
Resumo:
The slope of the distance-time relationship from maximal 200 and 400 in bouts (S(200-400)) has been increasingly employed for setting training intensities in swimming. However, physiological and mechanical responses at this speed are poorly understood. Thus, this study investigated blood lactate, heart rate (HR), stroke rate (SR), stroke length (SL) and RPE responses to an interval swimming set at S(200-400) in trained swimmers. In a 50-m pool, twelve athletes (16.5 +/- 1.2 yr, 176 +/- 7 cm, 68.4 +/- 5.4 kg, and 7.8 +/- 2.5% body fat) performed maximal 200 and 400 m crawl trials for S(200-400) determination (1.28 +/- 0.05 m/s). Thereafter, swimmers were instructed to perform 5 x 400 in at this speed with 1.5 min rest between repetitions. Three athletes Could not complete the set (exhaustion at 21.0 +/- 3.1 min). For the remaining swimmers (total set duration = 32.0 +/- 1.3 min) significant increases) (p < 0.05) in blood lactate (5.7 +/- 0.8-7.9 +/- 2.4 mmol/l), SR (29.6 +/- 3.2-32.1 +/- 4.1 cycles/min), HR (169 +/- 11-181 +/- 8 bpm) and RPE (13.3 +/- 1.6-16.3 +/- 2.6) were observed through the IS. Conversely, SL decreased significantly (p < 0.05) from the first to the fifth repetition (2.48 +/- 0.22-2.31 +/- 0.24 m/cycle). These results suggest that interval swimming at S(200-400) represents an intense physiological, mechanical and perceptual stimulus that can be sustained for a prolonged period by most athletes. (C) 2008 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The main objective of this study was to analyze the behavior of variables related to swim ability at and above maximal lactate steady state (MLSS), performed at continuous and intermittent conditions in individuals with different aerobic performance levels. Participated of this study male swimmers with ages between 20 to 25 years, specialists in events of 400 m, 800 m and 1500 m and open water swims, with at least 3 years of experience in the modality. The individuals performed a maximal 400-m swim test. After this test, they were divided into two groups, in accordance with the speed attained during 400-m swim test: G1 (higher performance) and G2 (lower performance). For the determination of continuous MLSS (MLSSc), 2 to 4 trials of 30-min were performed. For the determination of the intermittent MLSS (MLSSi) 2 to 4 trials of 30-min (12 repetitions of 2 min 30 s, with 30 s of rest) were performed, in constant speed, with the first trial performed at 102.5% MLSSc. Th technical indexes, stroke rate (FB) and stroke length (CB) were determined in all tests. The SR was calculated trough recordings using the time needed to perform five stroke cycles. The SL was calculated dividing the speed by the SR. There was no significant difference on the antropometric characteristics between groups. The speed at and above MLSSc were significantly higher at G1 (1,23±0,05 e 1,27±0,06, respectively) than G2 (1,10±0,06 e 1,13±0,06, respectively). There was significant change in SL and SR in G2. In the same way, there was significant change in SL and SR only in G2, above MLSSc. Similar to continuous condition, the speeds at and above MLSSi were significantly higher in G1 (1,27±0,05 e 1,30±0,05, respectively) do que no G2 (1,14±0,07 e 1,16±0,07, respectively). There was significant change in SL and SR only in G2. There was significant change in SR and SL in both groups above MLSSi. Thus,...(Complete abstract click electronic access below)
Resumo:
The aim of this study was to analyze and evaluate the performance of swimmers tied to the Extension Project Natação na UNESP at distances of 25m, 50m, 75m and 100m. The study included 20 people, including 12 men and 8 women. From an aerial footage was possible to record the tests proposed by the analysis of videos of, Freestyleand Backstroke styles for stroke cycles, average speed, stroke frequency and time proof stretches of 0-25m, 25-50m, 50-75m e 75-100m. Thus, it was possible to calculate stroke length, frequency, average speed as proposed in the study of Maglischo (1999). From these data were applied to descriptive statistics with mean and standard deviation, minimum and maximum scores in the different parameters of analysis and statistical tests, t-test and correlation to make comparisons between styles and between the distances swims by the subjects. Regarding the performance of the participants in the eight proposed tests, it can be said that most have already mastered the styles Crawl and Back Crawl for having managed to finish the tests proposed. However, the results of the variables analyzed mainly by the total time obtained in the tests can classify the subjects in the initial phase of learning and to start the training will be necessary to improve the implementation of styles
Resumo:
Dolomite [CaMg(CO3)2] is an intolerable impurity in phosphate ores due to its MgO content. Traditionally, the Florida phosphate industry has avoided mining high-MgO phosphate reserves due to the lack of an economically viable process for removal of dolomite. However, as the high grade phosphate reserves become depleted, more emphasis is being put on the development of a cost effective method for separating dolomite from high-MgO phosphate ores. In general, the phosphate industry demands a phosphate concentrate containing less than 1%MgO. Dolomite impurities have mineralogical properties that are very similar to the desired phosphate minerals (francolite), making the separation of the two minerals very difficult. Magnesium is primarily found as distinct dolomite-rich pebbles, very fine dolomite inclusions in predominately francolite pebbles, and magnesium substituted into the francolite structure. Jigging is a gravity separation process that attempts to take advantage of the density difference between the dolomite and francolite pebbles. A unique laboratory scale jig was designed and built at Michigan Tech for this study. Through a series of tests it was found that a pulsation rate of 200 pulse/minute, a stroke length of 1 inch, a water addition rate of 0.5gpm, and alumina ragging balls were optimum for this study. To investigate the feasibility of jigging for the removal of dolomite from phosphate ore, two high-MgO phosphate ores were tested using optimized jigging parameters: (1) Plant #1 was sized to 4.00x0.85mm and contained 1.55%MgO; (2) Plant #2 was sized to 3.40mmx0.85mm and contained 3.07% MgO. A sample from each plant was visually separated by hand into dolomite and francolite rich fractions, which were then analyzed to determine the minimum achievable MgO levels. For Plant #1 phosphate ore, a concentrate containing 0.89%MgO was achieved at a recovery of 32.0%BPL. For Plant #2, a phosphate concentrate containing 1.38%MgO was achieved at a recovery of 74.7%BPL. Minimum achievable MgO levels were determined to be 0.53%MgO for Plant #1 and 1.15%MgO for Plant #2.
Resumo:
The main focus of this research is to design and develop a high performance linear actuator based on a four bar mechanism. The present work includes the detailed analysis (kinematics and dynamics), design, implementation and experimental validation of the newly designed actuator. High performance is characterized by the acceleration of the actuator end effector. The principle of the newly designed actuator is to network the four bar rhombus configuration (where some bars are extended to form an X shape) to attain high acceleration. Firstly, a detailed kinematic analysis of the actuator is presented and kinematic performance is evaluated through MATLAB simulations. A dynamic equation of the actuator is achieved by using the Lagrangian dynamic formulation. A SIMULINK control model of the actuator is developed using the dynamic equation. In addition, Bond Graph methodology is presented for the dynamic simulation. The Bond Graph model comprises individual component modeling of the actuator along with control. Required torque was simulated using the Bond Graph model. Results indicate that, high acceleration (around 20g) can be achieved with modest (3 N-m or less) torque input. A practical prototype of the actuator is designed using SOLIDWORKS and then produced to verify the proof of concept. The design goal was to achieve the peak acceleration of more than 10g at the middle point of the travel length, when the end effector travels the stroke length (around 1 m). The actuator is primarily designed to operate in standalone condition and later to use it in the 3RPR parallel robot. A DC motor is used to operate the actuator. A quadrature encoder is attached with the DC motor to control the end effector. The associated control scheme of the actuator is analyzed and integrated with the physical prototype. From standalone experimentation of the actuator, around 17g acceleration was achieved by the end effector (stroke length was 0.2m to 0.78m). Results indicate that the developed dynamic model results are in good agreement. Finally, a Design of Experiment (DOE) based statistical approach is also introduced to identify the parametric combination that yields the greatest performance. Data are collected by using the Bond Graph model. This approach is helpful in designing the actuator without much complexity.