968 resultados para Small-diameter Columns


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Small spindleless veneer lathe technology was used to produce veneer sheets as an alternative processing option to optimise the use of small log plantation resource. Thinned (300 spha) and unthinned control (1000 spha) plantings of 10.5-year-old Corymbia citriodora ssp. variegata (CCV) and E. dunnii (Dunn’s white gum) grown in two contrasting sites from climatic regions with large annual rainfall differences were studied. Overall veneer gross recoveries ranged from 50% to 70%, which were up to 3 times higher than typical sawn green-off saw recoveries from small plantation hardwood logs of similar diameter. Major limiting factors preventing veneer from meeting higher grades were the presence of kino defects and encased knots. Splits in E. dunnii veneer also contributed to reduced grade quality. Differences between two thinning treatments for veneer properties and grade recovery were generally small. There was significant evidence of site and species differences on veneer quality. The good quality site with higher rainfall in northern New South Wales produced denser and stiffer veneers with higher grade recoveries. CCV is a superior structural veneer species with high wood density and hardness as well as very good veneer stiffness exceeding 15,000 MPa but Dunn’s white gum has also demonstrated good potential as a useful structural plywood resource. Results indicate that relatively high veneer recoveries were achieved for the sub-tropical plantation hardwoods combined with very superior mechanical properties which suggest that veneer production have suitable attributes for a range of engineered wood products including plywood and laminated veneer lumber.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Pd-contacted dopant-free CNTFET with small-diameter (0.57 nm) carbon nanotube showing an anomalous n-type electrical characteristic is reported for the first time. This observed behaviour is attributed to a carbon nanotube work function higher than (or close to) palladium as well as a large hole-to-electron effective mass ratio of approximately 2.5 predicted by hybridization in small-diameter nanotubes. A variation of the conduction type with temperature is also observed and is attributed to an increase of the palladium work function and decrease of the CNT work function with increasing temperature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study concerns the wrinkling performance of thin membranes for use as novel reflectors in space-based telescopes. We introduce small-scale experiments for inducing and interrogating wrinkling patterns in at membranes, and we capture these details computationally by performing a range of finite element analysis. The overall aim is to assess the sophistication of modelling, to verify the feasibility of a small-diameter reector concept proposed in accompanying work. © 2009 by the American Institute of Aeronautics and Astronautics, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Dislocation remains a difficult problem in total hip arthroplasty. Large-diameter femoral heads may lower the incidence of dislocation by enhancing the jump distance and decreasing impingement, but their performance against small-diameter heads has not been assessed. This study compared the mid-term radiographic and functional outcomes of two matched cohorts of patients undergoing total hip arthroplasty who had a high pre-operative risk for dislocation and who received either small-diameter (26- or 28-millimeters) or large-diameter (≥36-millimeters) femoral heads. METHODS: All patients who received large-diameter heads (≥36-millimeter) between 2002 and 2005, and who had pre-operative risk factors for dislocation, were identified in the institution's joint registry. Forty-one patients (52 hips) who received large-diameter heads were identified, and these patients were matched to 48 patients (52 hips) in the registry who received small-diameter femoral heads. RESULTS: At mean final follow-up of 62 months (range, 49 to 101 months), both groups achieved excellent functional outcomes as measured by Harris Hip scores, with slightly better final scores in the large-diameter group (90 vs. 83 points). No patient showed any radiographic signs of loosening. No patient dislocated in the large-diameter femoral head group; the smaller-diameter group had a greater rate of dislocation (3.8%, 2 out of 52). CONCLUSIONS: Large-diameter femoral head articulations may reduce dislocation rates in patients who have a high pre-operative risk for dislocation while providing the same functional improvements and safety as small-diameter bearings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment MATERIALS AND METHODS. Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their respective implants (3.5 x 11 mm) and after a 10 minute interval, implant/abutment assemblies were subjected to static compressive test, performed in a universal test machine with 1 mm/min displacement, at 45 degrees inclination. The maximum deformation force was determined. Data were statistically analyzed by student t test. RESULTS. Maximum deformation force of 4.8 mm and 3.8 mm abutments was approximately 95.33 kgf and 95.25 kgf, respectively, but no fractures were noted after mechanical test. Statistical analysis demonstrated that the evaluated abutments were statistically similar (P=.230). CONCLUSION. Abutment measuring 3.8 mm in diameter (reduced) presented mechanical properties similar to 4.8 mm (conventional) abutments, enabling its clinical use as indicated. [J Adv Prosthodont 2012;4:158-61]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Methods and Materials: Patients with an edentulous mandible received one TiZr and one Ti Grade IV small-diameter bone level implant (3.3 mm, SLActive®) in the interforaminal region. The site distribution was randomized and double-blinded. Outcome measures included change in radiological peri-implant bone level from surgery to 12 months post-insertion (primary), implant survival, success, soft tissue conditions, and safety (secondary). Results: Of 91 treated patients, 87 were available for the 12-month follow-up. Peri-implant bone level change (-0.3 ± 0.5 mm vs -0.3 ± 0.6 mm), plaque, and sulcus bleeding indices were not significantly different between TiZr and Ti Grade IV implants. Implant survival rates were 98.9 percent and 97.8 percent, success rates were 96.6 percent and 94.4 percent, respectively. Nineteen minor and no serious adverse events were related to the study devices. Conclusion: This study confirms that TiZr small-diameter bone level implants provide at least the same outcomes after 12 months as Ti Grade IV bone level implants. The improved mechanical properties of TiZr implants may extend implant therapy to more challenging clinical situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Patency of small synthetic bypass grafts is inferior compared to autologous grafts for revascularization procedures. Titanium coating of foreign surfaces has shown to decrease thrombogenicity, enhance biocompatibility and promote adhesion of endothelial cells. The aim of this study was to test the effect of titanium coating of small diameter ePTFE grafts on short term patency, neo-endothelialization and neointimal proliferation. METHODS: Bilateral carotid graft interposition was performed in 5 pigs with uncoated (n=5) and titanium-coated (n=5) ePTFE grafts (internal diameter=4 mm, length=5 cm), thus each pig served as its own control. At the end of the study (30 +/- 3 days), patency and stenosis severity was assessed by carotid angiography. Animals were sacrificed and grafts were excised for histology and scanning electron microscopy. Morphometry of histologic sections was carried out to determine neointimal proliferation and percentage of neo-endothelial coverage. RESULTS: Patency rate was 80% for uncoated and titanium-coated grafts. Quantitative angiography did not show any significant difference in lumen size between two groups. Morphometry revealed a significantly higher cellular coverage with CD31 positive endothelial cells for titanium-coated (84 +/- 19%) than uncoated grafts (48 +/- 26%, p<0.001). There was a non significant trend (p=0.112) towards increased neointimal proliferation in titanium-coated (94 +/- 61 micron2/micron) compared to uncoated grafts (60 +/- 57 micron2/micron). CONCLUSIONS: Patency rate in uncoated and titanium-coated ePTFE grafts is similar at one month. However, titanium coated grafts show a significant improvement in neo-endothelialization compared to uncoated grafts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND & AIMS Patients with cirrhosis and variceal hemorrhage have a high risk of rebleeding. We performed a prospective randomized trial to compare the prevention of rebleeding in patients given a small-diameter covered stent vs those given hepatic venous pressure gradient (HVPG)-based medical therapy prophylaxis. METHODS We performed an open-label study of patients with cirrhosis (92% Child class A or B, 70% alcoholic) treated at 10 medical centers in Germany. Patients were assigned randomly more than 5 days after variceal hemorrhage to groups given a small covered transjugular intrahepatic portosystemic stent-shunt (TIPS) (8 mm; n = 90), or medical reduction of portal pressure (propranolol and isosorbide-5-mononitrate; n = 95). HVPG was determined at the time patients were assigned to groups (baseline) and 2 weeks later. In the medical group, patients with an adequate reduction in HVPG (responders) remained on the drugs whereas nonresponders underwent only variceal band ligation. The study was closed 10 months after the last patient was assigned to a group. The primary end point was variceal rebleeding. Survival, safety (adverse events), and quality of life (based on the Short Form-36 health survey) were secondary outcome measures. RESULTS A significantly smaller proportion of patients in the TIPS group had rebleeding within 2 years (7%) than in the medical group (26%) (P = .002). A slightly higher proportion of patients in the TIPS group experienced adverse events, including encephalopathy (18% vs 8% for medical treatment; P = .05). Rebleeding occurred in 6 of 23 patients (26%) receiving medical treatment before hemodynamic control was possible. Per-protocol analysis showed that rebleeding occurred in a smaller proportion of the 32 responders (18%) than in nonresponders who received variceal band ligation (31%) (P = .06). Fifteen patients from the medical group (16%) underwent TIPS placement during follow-up evaluation, mainly for refractory ascites. Survival time and quality of life did not differ between both randomized groups. CONCLUSIONS Placement of a small-diameter, covered TIPS was straightforward and prevented variceal rebleeding in patients with Child A or B cirrhosis more effectively than drugs, which often required step-by-step therapy. However, TIPS did not increase survival time or quality of life and produced slightly more adverse events. Clinical Trial no: ISRCTN 16334693.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus bleeding indices, radiographic crestal bone level, as well as implant survival and success 60 months after implant placement. RESULTS Of the 91 patients who initially received implants, 75 completed the 36 month follow-up and 49 were available for the 60 month examination. Two patients were excluded so that a total of 47 patients with an average age of 72 ± 8 years were analysed. The characteristics and 36-month performance of the present study cohort did not differ from the non-included initial participants (p > 0.05). In the period since the 36-month follow-up examination, no implant was lost. The cumulative implant survival rate was 98.9 % for the TiZr group and 97.8 % for the Ti Grade IV group. Crestal bone level changes at 60 months were not different in the test and control group (TiZr -0.60 ± 0.69 mm and Ti Grade IV -0.61 ± 0.83 mm; p = 0.96). The cumulative implant success rate after 60 months was 95.8 and 92.6 % for TiZr and Ti Grade IV, respectively. CONCLUSIONS After 60 months, the positive outcomes of the 36 month results for TiZr and Ti Grade IV implants were confirmed, with no significant differences with regard to crestal bone level change, clinical parameters and survival or success rates. TiZr implants performed equally well compared to conventional Ti Grade IV 3.3 mm diameter-reduced implants for mandibular removable overdentures. TRIAL REGISTRATION Registered on www.clinicaltrials.gov: NCT01878331.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of loading. Modified plaque and sulcus bleeding indices, radiographic bone level, and implant survival and success were evaluated up to 36 months. RESULTS Of 91 treated patients, 75 completed the three-year follow-up. Three implants were lost (two control and one test implant). The survival rates were 98.7% and 97.3%, and the mean marginal bone level change was -0.78 ± 0.75 and -0.60 ± 0.71 mm for TiZr and Ti Grade IV implants. Most patients had a plaque score of 0 or 1 (54% for test and 51.7% for control), and a sulcus bleeding score of 0 (46.1% for test and 44.9% for control). No significant differences were found between the two implant types for bone-level change, soft tissue parameters, survival and success. CONCLUSIONS After 36 months, similar outcomes were found between Ti Grade IV and TiZr implants. The results confirm that the results seen at 12 months continue over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The functional and structural performance of a 5 cm synthetic small diameter vascular graft (SDVG) produced by the copolymerization of polyvinyl alcohol hydrogel with low molecular weight dextran (PVA/Dx graft) associated to mesenchymal stem cells (MSCs)-based therapies and anticoagulant treatment with heparin, clopidogrel and warfarin was tested using the ovine model during the healing period of 24 weeks. The results were compared to the ones obtained with standard expanded polyetetrafluoroethylene grafts (ePTFE graft). Blood flow, vessel and graft diameter measurements, graft appearance and patency rate (PR), thrombus, stenosis and collateral vessel formation were evaluated by B-mode ultrasound, audio and color flow Doppler. Graft and regenerated vessels morphologic evaluation was performed by scanning electronic microscopy (SEM), histopathological and immunohistochemical analysis. All PVA/Dx grafts could maintain a similar or higher PR and systolic / diastolic laminar blood flow velocities were similar to ePTFE grafts. CD14 (macrophages) and α-actin (smooth muscle) staining presented similar results in PVA/Dx/MSCs and ePTFE graft groups. Fibrosis layer was lower and endothelial cells were only detected at graft-artery transitions where it was added the MSCs. In conclusion, PVA/Dx graft can be an excellent scaffold candidate for vascular reconstruction, including clinic mechanically challenging applications, such as SDVGs, especially when associated to MSCs-based therapies to promote higher endothelialization and lower fibrosis of the vascular prosthesis, but also higher PR values.