960 resultados para Self detection


Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Little is known about the potential benefit of skin self-examination for melanoma prevention and early detection. Objectives: To determine whether skin self-examination is associated with reduced melanoma risk, self-detection of tumours, and reduced risk of deeper melanomas. METHODS We used data from a population-based case-control study (423 cases, 678 controls) to assess recent skin self-examination in relation to self-detection, melanoma risk and tumour depth ( ≤1 mm; > 1 mm). Logistic regression was used to estimate odds ratios (ORs) and confidence intervals (CIs) for associations of interest. RESULTS Skin self-examination conducted 1-11 times during a recent year was associated with a possible decrease in melanoma risk (OR 0·74; 95% CI 0·54-1·02). Melanoma risk was decreased for those who conducted skin self-examination and saw a doctor (OR 0·52; 95% CI 0·30-0·90). Among cases, those who examined their skin were twice as likely to self-detect the melanoma (OR 2·23; 95% CI 1·47-3·38), but self-detection was not associated with shallower tumours. Tumour depth was reduced for those who conducted skin self-examination 1-11 times during a recent year (OR 0·39; 95% CI 0·18-0·81), but was not influenced by seeing a doctor, or by conducting skin self-examination and seeing a doctor. CONCLUSIONS Risk of a deeper tumour and possibly risk of melanoma were reduced by skin self-examination 1-11 times annually. Melanoma risk was markedly reduced by skin self-examination coupled with a doctor visit. We cannot, however, exclude the possibility that our findings reflect bias or confounding. Additional studies are needed to elucidate the potential benefits of skin self-examination for melanoma prevention and early detection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Peu différenciées à la naissance, les émotions deviendraient intelligibles en étant élevées à la conscience par le développement d’une sensibilité aux sensations internes accompagnant l’émotion, sa représentation et sa symbolisation (Gergely & Watson, 1996). La théorie du miroir affectif-parental du biofeedback social de Gergely & Watson (1996), poussée plus loin par Fonagy, Gergely, Jurist et Target (2002), explique comment une interaction de biofeedback social complexe, innée, et probablement implicite, s’établit entre parent et nouveau-né pour aider ce dernier à différencier les somatosensations accompagnant l’expérience d’une émotion, au travers d’un comportement parental de miroir. Le but de cette thèse est de réviser cette théorie, et plus particulièrement l’hypothèse du miroir « marqué » (markedness), qui serait nécessaire pour dissocier le miroir parental du parent, et permettre l’appropriation de son contenu informationnel par l’enfant. Ce processus de sensibilisation est conçu comme partie intégrante du travail de symbolisation des émotions chez les enfants autant que chez les adultes. Cependant, le miroir marqué se manifestant par une expression exagérée ou « voix de bébé » (motherese) nécessiterait l’utilisation par le thérapeute d’une « voix de patient » (therapese) (Fonagy, 2010) pour être appliqué à la psychothérapie adulte, une proposition difficile à soutenir. La révision examine comment la sensibilisation d’une émotion est accomplie : par un mécanisme d’internalisation nécessitant un miroir « marqué » ou par un mécanisme de détection de la contingence de l’enfant. Elle démontre que le détecteur de contingence du nouveau-né (d’un fonctionnement semblable au système d’entraînement par biofeedback pour adultes) est le médiateur des fonctions de sensibilisation, de représentation, et de symbolisation de la ii sensation d’une émotion par ses processus de détection de la covariance-invariance, de la maximisation, et du contrôle contingent du miroir parental. Ces processus permettent à l’émotion de devenir consciente, que le miroir parental soit ‘marqué’ ou non. Le modèle révisé devient donc applicable à la thérapie des adultes. Une vignette clinique analysée à l’aide de la perspective du Boston Change Process Study Group sur le changement est utilisée pour contraster et illustrer les processus de sensibilisation et de symbolisation des émotions, et leur application à la psychothérapie adulte. Cette thèse considère les implications cliniques du nouveau modèle, et elle spécule sur les conséquences de difficultés parentales vis-à-vis de la disponibilité requise par les besoins de biofeedback social du nouveau-né, et sur les conséquences de traumatismes déconnectant des émotions déjà sensibilisées de leurs représentations. Finalement, elle suggère que le miroir sensible des émotions en thérapie puisse remédier à ces deux sortes de difficultés, et que le modèle puisse être utilisé concurremment à d’autres modèles du changement, en facilitant la génération d’états internes ressentis et symbolisés pouvant être utilisés pour communiquer avec soi-même et les autres pour la réparation de difficultés émotionnelles et relationnelles chez les enfants et les adultes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It is recognised that individuals do not always respond honestly when completing psychological tests. One of the foremost issues for research in this area is the inability to detect individuals attempting to fake. While a number of strategies have been identified in faking, a commonality of these strategies is the latent role of long term memory. Seven studies were conducted in order to examine whether it is possible to detect the activation of faking related cognitions using a lexical decision task. Study 1 found that engagement with experiential processing styles predicted the ability to fake successfully, confirming the role of associative processing styles in faking. After identifying appropriate stimuli for the lexical decision task (Studies 2A and 2B), Studies 3 to 5 examined whether a cognitive state of faking could be primed and subsequently identified, using a lexical decision task. Throughout the course of these studies, the experimental methodology was increasingly refined in an attempt to successfully identify the relevant priming mechanisms. The results were consistent and robust throughout the three priming studies: faking good on a personality test primed positive faking related words in the lexical decision tasks. Faking bad, however, did not result in reliable priming of negative faking related cognitions. To more completely address potential issues with the stimuli and the possible role of affective priming, two additional studies were conducted. Studies 6A and 6B revealed that negative faking related words were more arousing than positive faking related words, and that positive faking related words were more abstract than negative faking related words and neutral words. Study 7 examined whether the priming effects evident in the lexical decision tasks occurred as a result of an unintentional mood induction while faking the psychological tests. Results were equivocal in this regard. This program of research aligned the fields of psychological assessment and cognition to inform the preliminary development and validation of a new tool to detect faking. Consequently, an implicit technique to identify attempts to fake good on a psychological test has been identified, using long established and robust cognitive theories in a novel and innovative way. This approach represents a new paradigm for the detection of individuals responding strategically to psychological testing. With continuing development and validation, this technique may have immense utility in the field of psychological assessment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A nanoscale-sized cage with a trigonal prismatic shape is prepared by coordination-driven self-assembly of a predesigned organometallic Pt-3 acceptor with an organic clip-type ligand. This trigonal prism is fluorescent and undergoes efficient fluorescence quenching by nitroaromatics, which are the chemical signatures of many explosives.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The design and preparation of novel M3L2 trigonal cages via the coordination-driven self-assembly of preorganized metalloligands containing octahedral aluminum(III), gallium(III), or ruthenium(II) centers is described. When tritopic or dinuclear linear metalloligands and appropriate complementary subunits are employed, M3L2 trigonal-bipyramidal and trigonal-prismatic cages are self-assembled under mild conditions. These three-dimensional cages were characterized with multinuclear NMR spectroscopy (H-1 and P-31) and high-resolution electrospray ionization mass spectrometry. The structure of one such trigonal-prismatic cage, self-assembled from an arene ruthenium metalloligand, was confirmed via single-crystal X-ray crystallography. The fluorescent nature of these prisms, due to the presence of their electron-rich ethynyl functionalities, prompted photophysical studies, which revealed that electron-deficient nitroaromatics are effective quenchers of the cages' emission. Excited-state charge transfer from the prisms to the nitroaromatic substrates can be used as the basis for the development of selective and discriminatory turn-off fluorescent sensors for nitroaromatics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We develop several novel signal detection algorithms for two-dimensional intersymbol-interference channels. The contribution of the paper is two-fold: (1) We extend the one-dimensional maximum a-posteriori (MAP) detection algorithm to operate over multiple rows and columns in an iterative manner. We study the performance vs. complexity trade-offs for various algorithmic options ranging from single row/column non-iterative detection to a multi-row/column iterative scheme and analyze the performance of the algorithm. (2) We develop a self-iterating 2-D linear minimum mean-squared based equalizer by extending the 1-D linear equalizer framework, and present an analysis of the algorithm. The iterative multi-row/column detector and the self-iterating equalizer are further connected together within a turbo framework. We analyze the combined 2-D iterative equalization and detection engine through analysis and simulations. The performance of the overall equalizer and detector is near MAP estimate with tractable complexity, and beats the Marrow Wolf detector by about at least 0.8 dB over certain 2-D ISI channels. The coded performance indicates about 8 dB of significant SNR gain over the uncoded 2-D equalizer-detector system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel self-referencing fiber optic intensity sensor based on bending losses of a partially polished polymer optical fiber (POF) coupler is presented. The coupling ratio (K) depends on the external liquid in which the sensor is immersed. It is possible to distinguish between different liquids and to detect their presence. Experimental results for the most usual liquids found in industry, like water and oil, are given. K value increases up to 10% from the nominal value depending on the liquid. Sensor temperature dependence has also been studied for a range from 25 degrees C (environmental condition) to 50 degrees C. Any sector requiring liquid level measurements in flammable atmospheres can benefit from this intrinsically safe technology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ferrocene-terminated self-assembled monolayers (Fc-SAMs) are one of the most studied molecular aggregates on metal electrodes. They are easy to fabricate and provide a stable and reproducible system to investigate the effect of the microenvironment on the electron transfer parameters. We propose a novel application for Fc-SAMs, the detection of molecular interactions, based on the modification of the SAM with target-specific receptors. Mixed SAMs were fabricated by coimmobilization on Au electrodes of thiolated alkane chains with three different head groups: hydroxy terminating head group, ferrocene head group, and a functional head group such as biotin. Upon binding, the intrinsic electric charge of the target (e.g., streptavidin) modifies the electrostatic potential at the plane of electron transfer, causing a shift in the formal potential E degrees '. The SAMs were characterized by AC voltammetry. The detection mechanism is confirmed by measurements of formal potential as a function of electrolyte pH.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this correspondence, we report on the first preparation of novel, robust Ru(bpy)(3)(2+)-containing supramolecular microstructures via a solution-based self-assembly strategy, carried out by directly mixing H2PtCl6 and Ru(bpy)(3)Cl-2 aqueous solutions at room temperature. It reveals that both the molar ratio and concentration of reactants have a heavy influence on the morphologies of such microstructures. The electrochemical behavior of the Ru(bpy)(3)(2+) components contained in the solid film of the microstructures formed on the electrode surface is also studied and found to exhibit a diffusion-controlled voltammetric feature. Most importantly, such microstructures exhibit excellent electrochemiluminescence (ECL) behaviors and therefore hold great promise as new luminescent materials for solid-state ECL detection in capillary electrophoresis (CE) or CE microchip.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A Ru(bpy)(3)(2+)-doped silica nanoparticle-[Ru@Silica] modified indium tin oxide electrode was prepared by simple electrostatic self-assembly technique, and one-electron catalytic oxidation of guanine bases in double-strand and denatured DNA was realized using the electrochemiluminescence detection means.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Colloidal Au particles have been deposited on the gold electrode through layer-by-layer self-assembly using cysteamine as cross-linkers. Self-assembly of colloidal Au on the gold electrode resulted in ail easier attachment of antibody, larger electrode surface and ideal electrode behavior. The redox reactions of [Fe(CN)(6)]-/[Fe(CN)(6)](3-) on the gold surface were blocked due to antibody immobilization, which were investigated by cyclic voltammetry and impedance spectroscopy. The interaction of antigen with grafted antibody recognition layers was carried out by soaking the modified electrode into a phosphate buffer at pH 7.0 with various concentrations of antigen at 37degreesC for 30 min. Further, an amplification strategy to use biotin conjugated antibody was introduced for improving the sensitivity of impedance measurements. Thus, the sensor based oil this immobilization method exhibits a large linear dynamic range, from 5 - 400 mug/L for detection of Human IgG. The detection limit is about 0.5 mug/L.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The target DNA was immobilized successfully on gold colloid particles associated with a cysteamine monolayer on gold electrode surface. Self-assembly of colloidal An onto a cysteamine modified gold electrode can enlarge the electrode surface area and enhance greatly the amount of immobilized single stranded DNA (ssDNA). The electrontransfer processes of [Fe(CN)(6)](4)-/[Fe(CN)(6)](3-) on the gold surface were blocked due to the procedures of the target DNA immobilization, which was investigated by impedance spectroscopy. Then single stranded target DNA immobilized on the gold electrode hybridized with the silver nanoparticle-oligonucleotide DNA probe, followed by the release of the silver metal atoms anchored on the hybrids by oxidative metal dissolution, and the indirect determination of the released solubilized Ag-1 ions by anodic stripping voltammetry (ASV) at a carbon fiber microelectrode. The results show that this method has good correlation for DNA detection in the range of 10-800 pmol/1 and allows the detection level as low as 5 pmol/1 of the target oligonucleotides.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Capillary electrophoresis (CE)/electrochemical detection (EC) for the simultaneous detection of hydrazine, methylhydrazine, and isoniazid has been developed with a 4-pyridyl hydroquinone self-assembled microdisk platinum electrode. Such an electrode has very high catalytic ability for hydrazines and they could be detected even at 0.0 V. The responses for hydrazine, methylhydrazine, and isoniazid are linear over 3 orders of detected concentration and of magnitude of 0.2-400 mu M, 0.2-400 mu M, 0.5 mu M-2 mM, with correlation coefficients of 0.9998, 0.9991, and 0.9982, respectively. And they could be detected to levels of 0.1, 0.1 and 0.2 mu M, respectively. This modified electrode was found to be very stable and reproducible when continuously used as detector for capillary electrophoresis for period of at least 4 weeks with no apparent loss of response. (C) 1999 Elsevier Science B.V. All rights reserved.