898 resultados para Saturation Deficit


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The efficiency of agricultural management practices to store SOC depends on C input level and how far a soil is from its saturation level (i.e. saturation deficit). The C Saturation hypothesis suggests an ultimate soil C stabilization capacity defined by four SOM pools capable of C saturation: (1) non-protected, (2) physically protected, (3) chemically protected and (4) biochemically protected. We tested if C saturation deficit and the amount of added C influenced SOC storage in measurable soil fractions corresponding to the conceptual chemical, physical, biochemical, and non-protected C pools. We added two levels of C-13- labeled residue to soil samples from seven agricultural sites that were either closer to (i.e., A-horizon) or further from (i.e., C-horizon) their C saturation level and incubated them for 2.5 years. Residue-derived C stabilization was, in most sites, directly related to C saturation deficit but mechanisms of C stabilization differed between the chemically and biochemically protected pools. The physically protected C pool showed a varied effect of C saturation deficit on C-13 stabilization, due to opposite behavior of the POM and mineral fractions. We found distinct behavior between unaggregated and aggregated mineral-associated fractions emphasizing the mechanistic difference between the chemically and physically protected C-pools. To accurately predict SOC dynamics and stabilization, C Saturation of soil C pools, particularly the chemically and biochemically protected pools, should be considered. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Although current assessments of agricultural management practices on soil organic C (SOC) dynamics are usually conducted without any explicit consideration of limits to soil C storage, it has been hypothesized that the SOC pool has an upper, or saturation limit with respect to C input levels at steady state. Agricultural management practices that increase C input levels over time produce a new equilibrium soil C content. However, multiple C input level treatments that produce no increase in SOC stocks at equilibrium show that soils have become saturated with respect to C inputs. SOC storage of added C input is a function of how far a soil is from saturation level (saturation deficit) as well as C input level. We tested experimentally if C saturation deficit and varying C input levels influenced soil C stabilization of added C-13 in soils varying in SOC content and physiochemical characteristics. We incubated for 2.5 years soil samples from seven agricultural sites that were closer to (i.e., A-horizon) or further from (i.e., C-horizon) their C saturation limit. At the initiation of the incubations, samples received low or high C input levels of 13 C-labeled wheat straw. We also tested the effect of Ca addition and residue quality on a subset of these soils. We hypothesized that the proportion of C stabilized would be greater in samples with larger C Saturation deficits (i.e., the C- versus A-horizon samples) and that the relative stabilization efficiency (i.e., Delta SCC/Delta C input) would decrease as C input level increased. We found that C saturation deficit influenced the stabilization of added residue at six out of the seven sites and C addition level affected the stabilization of added residue in four sites, corroborating both hypotheses. Increasing Ca availability or decreasing residue quality had no effect on the stabilization of added residue. The amount of new C stabilized was significantly related to C saturation deficit, supporting the hypothesis that C saturation influenced C stabilization at all our sites. Our results suggest that soils with low C contents and degraded lands may have the greatest potential and efficiency to store added C because they are further from their saturation level. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The results of research into the water relations and irrigation requirements of lychee are collated and reviewed. The stages of plant development are summarised, with an emphasis on factors influencing the flowering process. This is followed by reviews of plant water relations, water requirements, water productivity and, finally, irrigation systems. The lychee tree is native to the rainforests of southern China and northern Vietnam, and the main centres of production remain close to this area. In contrast, much of the research on the water relations of this crop has been conducted in South Africa, Australia and Israel where the tree is relatively new. Vegetative growth occurs in a series of flushes. Terminal inflorescences are borne on current shoot growth under cool (<15 °C), dry conditions. Trees generally do not produce fruit in the tropics at altitudes below 300 m. Poor and erratic flowering results in low and irregular fruit yields. Drought can enhance flowering in locations with dry winters. Roots can extract water from depths greater than 2 m. Diurnal trends in stomatal conductance closely match those of leaf water status. Both variables mirror changes in the saturation deficit of the air. Very little research on crop water requirements has been reported. Crop responses to irrigation are complex. In areas with low rainfall after harvest, a moderate water deficit before floral initiation can increase flowering and yield. In contrast, fruit set and yield can be reduced by a severe water deficit after flowering, and the risk of fruit splitting increased. Water productivity has not been quantified. Supplementary irrigation in South-east Asia is limited by topography and competition for water from the summer rice crop, but irrigation is practised in Israel, South Africa, Australia and some other places. Research is needed to determine the benefits of irrigation in different growing areas. Copyright © Cambridge University Press 2013.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eddy-covariance measurements of net ecosystem exchange of CO(2) (NEE) and estimates of gross ecosystem productivity (GEP) and ecosystem respiration (R(E)) were obtained in a 2-4 year old Eucalyptus plantation during two years with very different winter rainfall In the first (drier) year the annual NEE GEP and RE were lower than the sums in the second (normal) year and conversely the total respiratory costs of assimilated carbon were higher in the dry year than in the normal year Although the net primary production (NPP) in the first year was 23% lower than that of the second year the decrease in the carbon use efficiency (CUE = NPP/GEP) was 11% and autotrophic respiration utilized more resources in the first dry year than in the second normal year The time variations in NEE were followed by NPP because in these young Eucalyptus plantations NEE is very largely dominated by NPP and heterotrophic respiration plays only a relatively minor role During the dry season a pronounced hysteresis was observed in the relationship between NEE and photosynthetically active radiation and NEE fluxes were inversely proportional to humidity saturation deficit values greater than 0 8 kPa Nighttime fluxes of CO(2) during calm conditions when the friction velocity (u) was below the threshold (0 25 ms(-1)) were estimated based on a Q(10) temperature-dependence relationship adjusted separately for different classes of soil moisture content which regulated the temperature sensitivity of ecosystem respiration (C) 2010 Elsevier B V All rights reserved

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Um experimento foi realizado com cevada (Hordeum vulgare L.) em condições de campo, com o objetivo de avaliar , durante um período de estiagem (82 e 89 dia após a emergência da cevada), o microclima formado pela cultura mantida na presença ou ausência de plantas daninhas desde o início do ciclo. Foram avaliados o teor de água do solo, umidade relativa, temperatura, tensão de vapor d'água, déficit de saturação de vapor d'água, potencial água e teor de água do ar nos períodos da s 8: 30 às 9:00, 11:30 às 12:00, 14:30 às 15:00 e 17:30 às 18:00 horas a 0,0m, 0,10m, 0,20m, 0,30m, 0,40m, 0,50m, 0,60m e 0,70m de altura na entrelinha da cultura. A presença das plantas daninhas na cultura durante o período de estiagem contribuiu para reduzir as perdas de água do solo para a atmosfera. Nos três primeiros períodos do dia e nas áreas mais próximas do solo, a cultura mantida no mato os menores valores de temperatura e déficit de saturação de vapor d'água do ar, e os maiores valores de umidade relativa, tensão de vapor d'água, potencial água e teor de água do ar, que proporcionaram redução do consumo de água do solo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho teve como objetivo verificar o efeito da cobertura plástica de polietileno de baixa densidade (PEBD) sobre a temperatura do ar, umidade relativa do ar, déficit de saturação e tensão de vapor d'água no ar. Pelos resultados encontrados neste trabalho as médias mensais de temperatura do ar no interior da estufa plástica foram superiores em 7,5%, a umidade relativa do ar em 7%, o déficit de saturação em 34% e a tensão atual de vapor d'água no ar em 4,7%, em relação aos valores determinados à campo. Observou-se maior efeito da cobertura plástica sobre as temperaturas máximas, as quais levaram as médias mensais a ficar entre 3,8 a 7,8 oC acima dos valores médios determinados no campo. Os valores médios mensais mínimos de temperatura e umidade relativa do ar entre a estufa e o campo apresentaram menor amplitude de variação que os valores máximos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eucalyptus plantations occupy almost 20 million ha worldwide and exceed 3.7 million ha in Brazil alone. Improved genetics and silviculture have led to as much as a three-fold increase in productivity in Eucalyptus plantations in Brazil and the large land area occupied by these highly productive ecosystems raises concern over their effect on local water supplies. As part of the Brazil Potential Productivity Project, we measured water use of Eucalyptus grandis x urophylla clones in rainfed and irrigated stands in two plantations differing in productivity. The Aracruz (lower productivity) site is located in the state of Espirito Santo and the Veracel (higher productivity) site in Bahia state. At each plantation, we measured stand water use using homemade sap flow sensors and a calibration curve using the clones and probes we utilized in the study. We also quantified changes in growth, leaf area and water use efficiency (the amount of wood produced per unit of water transpired). Measurements were conducted for 1 year during 2005 at Aracruz and from August through December 2005 at Veracel. Transpiration at both sites was high compared to other studies but annual estimates at Aracruz for the rainfed treatment compared well with a process model calibrated for the Aracruz site (within 10%). Annual water use at Aracruz was 1394 mm in rainfed treatments versus 1779 mm in irrigated treatments and accounted for approximately 67% and 58% of annual precipitation and irrigation inputs respectively. Increased water use in the irrigated stands at Aracruz was associated with higher sapwood area, leaf area index and transpiration per unit leaf area but there was no difference in the response of canopy conductance with air saturation deficit between treatments. Water use efficiency at the Aracruz site was also not influenced by irrigation and was similar to the rainfed treatment. During the period of overlapping measurements, the response to irrigation treatments at the more productive Veracel site was similar to Aracruz. Stand water use at the Veracel site totaled 975 mm and 1102 mm in rainfed and irrigated treatments during the 5-month measurement period respectively. Irrigated stands at Veracel also had higher leaf area with no difference in the response of canopy conductance with air saturation deficit between treatments. Water use efficiency was also unaffected by irrigation at Veracel. Results from this and other studies suggest that improved resource availability does not negatively impact water use efficiency but increased productivity of these plantations is associated with higher water use and should be given consideration during plantation management decision making processes aimed at increasing productivity. Published by Elsevier B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The encyrtid Coccidoxenoides perminutus is a widely distributed parasitoid of citrus mealybug (Planococcus citri). Worldwide, it has been implicated in successful biocontrol in only a few widely separated localities. C perminutus contributes little to control P. citri in field situations in south-east Queensland, Australia, but invades insectary cultures and reduces mealybug populations considerably under these controlled conditions. This discrepancy between poor field performance and good performance under controlled conditions was investigated to establish whether climatic factors inhibit the field performance of this species in the biological control of P. citri. Subsequent laboratory examination of the influence of varied humidities and temperatures on the activity levels and survival of C perminutus revealed a low tolerance for high saturation deficits (i.e., low % RH at high T degreesC) with reduced reproductive output. The influence of different food sources on adult survival and reproduction was also quantified, to establish if the adverse effects of climate could be overcome by supplementing adult diet. Neither honeydew from their mealybug hosts nor nectar from Alphitonia flowers significantly enhanced parasitoid survival. A subsequent test of five nectar species revealed a significant difference in their influence on C. perminutus survival and reproduction, with only Alpinia zerumbet proving to be as suitable as honey. The floral species that proved suitable in the laboratory need to be checked for their attractiveness to C perminutus in the field and for their ability to enhance the survival and reproductive output of parasitoids. This information suggests that the prevailing dry conditions in south-east Queensland citrus-growing areas apparently impede successful biological control of P. citri by C perminutus, but possibilities are available for habitat manipulation (by providing suitable nectar sources for adult parasitoids) to conserve and enhance C perminutus activity in the field. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar os indicadores fisiológicos da interação entre deficit hídrico e acidez do solo em plantas jovens de cana-de-açúcar. As plantas foram submetidas a três tratamentos de disponibilidade hídrica, medidos em percentagem de capacidade de campo (CC) - sem estresse (70% CC), estresse moderado (55% CC) e estresse severo (40% CC); e três tratamentos de acidez no solo, medidos em termos de saturação por bases (V) - baixa acidez (V = 55%), média acidez (V = 33%) e alta acidez (V = 23%). O experimento foi realizado em casa de vegetação a 29,7±4,3ºC e 75±10% UR. O delineamento experimental utilizado foi o de blocos ao acaso, em esquema fatorial 3x3, com quatro repetições. Após 60 dias, foram determinados os teores de solutos compatíveis - trealose, glicina betaína e prolina - na folha diagnóstico e o crescimento inicial da parte aérea. Os solutos compatíveis trealose, glicina betaína e prolina são indicadores do efeito da interação dos estresses hídrico e ácido no solo. O acúmulo dos solutos compatíveis nos tecidos foliares das plantas não é capaz de impedir a redução na produção de matéria seca da cana-de-açúcar, resultante do agravamento nas condições de disponibilidade hídrica e de acidez no solo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study addressed why girls are less likely to be referred for mental health services for attention deficit/hyperactivity disorder (ADHD) than boys. Ninety-six parents of children with elevated ADHD symptoms and 140 elementary school teachers read vignettes about children with ADHD. Half of the participants read vignettes with boys' names, and half read the same vignettes but with girls' names. Participants then rated their likeliness to seek or recommend services for the child in each vignette. Parents and teachers were less likely to seek or recommend services for girls than boys with ADHD, but results did not support the hypothesis that this is because girls are less disruptive than boys. Rather, differences in service seeking were explained by the fact that parents and teachers believed that learning assistance is less effective for girls than boys with ADHD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, sustained, selective, divided, and switching attention, and reloading of working memory were investigated in schizophrenia by using a newly developed Visual Attention Battery (VAB). Twenty-four outpatients with schizophrenia and 24 control participants were studied using the VAB. Performance on VAB components was correlated with performance of standard tests. Patients with schizophrenia were significantly impaired on VAB tasks that required switching of attention and reloading of working memory but had normal performance on tasks involving sustained attention or attention to multiple stimulus features. Switching attention and reloading of working memory were highly correlated with Trails (B - A) score for patients. The decline in performance on the switching-attention task in patients with schizophrenia met criteria for a differential deficit in switching attention. Future research should examine the neurophysiological basis of the switching deficit and its sensitivity and specificity to schizophrenia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has long been recognised that government and public sector services suffer an innovation deficit compared to private or market-based services. This paper argues that this can be explained as an unintended consequence of the concerted public sector drive toward the elimination of waste through efficiency, accountability and transparency. Yet in an evolving economy this can be a false efficiency, as it also eliminates the 'good waste' that is a necessary cost of experimentation. This results in a systematic trade0off in the public sector between the static efficiency of minimizing the misuse of public resources and the dynamic efficiency of experimentation. this is inherently biased against risk and uncertainty and therein, explains why governments find service innovation so difficult. In the drive to eliminate static inefficiencies, many political systems have susequently overshot and stifled policy innovation. I propose the 'Red Queen' solution of adaptive economic policy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been established that mixed venous oxygen saturation (SvO2) reflects the balance between systemic oxygen deliver y and consumption. Literature indicates that it is a valuable clinical indicator and has good prognostic value early in patient course. This article aims to establish the usefulness of SvO2 as a clinical indicator. A secondary aim was to determine whether central venous oxygen saturation (ScvO2) and SvO2 are interchangeable. Of particular relevance to cardiac nurses is the link between decreased SvO2 and cardiac failure in patients with myocardial infarction, and with decline in myocardial function, clinical shock and arrhythmias. While absolute values ScvO2 and SvO2 are not interchangeable, ScvO2 and SvO2are equivalent in terms of clinical course. Additionally, ScvO2 monitoring is a safer and less costly alternative to SvO2 monitoring. It can be concluded that continuous ScvO2 monitoring should potentially be undertaken in patients at risk of haemodynamic instability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decisions made in the earliest stage of architectural design have the greatest impact on the construction, lifecycle cost and environmental footprint of buildings. Yet the building services, one of the largest contributors to cost, complexity, and environmental impact, are rarely considered as an influence on the design at this crucial stage. In order for efficient and environmentally sensitive built environment outcomes to be achieved, a closer collaboration between architects and services engineers is required at the outset of projects. However, in practice, there are a variety of obstacles impeding this transition towards an integrated design approach. This paper firstly presents a critical review of the existing barriers to multidisciplinary design. It then examines current examples of best practice in the building industry to highlight the collaborative strategies being employed and their benefits to the design process. Finally, it discusses a case study project to identify directions for further research.